• 제목/요약/키워드: Development length

검색결과 5,033건 처리시간 0.026초

프리텐션공법의 프리스트레스트 콘크리트 부재의 정착길이 산정에 관한 실험 및 이론연구 (Derivation of Development Length in Pretensioned Prestressed Concrete Members)

  • 오병환;김의성;최영철
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.3-11
    • /
    • 2000
  • In pretensioned concrete structures, bond between prestressing steel and concrete is an essential component to ensure the integrity of a pretensioned member. The anchorage and development of the prestressing force depend exclusively on bond. The purpose of this study is to investigate the characteristics of bond and development length between pretensioned steel and concrete. To resolve the controversy over the adequacy of the current code provision on development length of prestressing strands, a comprehensive test program has been scheduled and twenty four rectangular prestressed concrete beams have been tested to determine development length. Major test variables include diameter of strands (12.7mm, 15.2mm) and concrete covers (3cm, 4cm, 5cm). The test results indicate that the development length based on the bond stress-slip relation. The proposed model can evaluate realistically the development length of pretensioned prestressed concrete members and can be the good basis for the future basis of code equations on development length of PSC members.

프리텐션 프리스트레스트 콘크리트 부재의 정착길이 정가 (Experimental Study on Development Length of Prestressing Strand in Pretensioned Prestressed Concrete Members)

  • 김의성
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.115-121
    • /
    • 2008
  • By bond mechanism between the prestressing strand and the concrete surrounding it, the effective force of prestressing must be transferred to the concrete entirely. The distance required to transfer the effective force of prestressing is called the transfer length, and the development length is the bond length required to anchor the strand as it resists external loads on the member. Transfer length was determined from the concrete strain profile at the level of the strands at transfer and development length was determined from various external loading lengths and compared with current code equation. Through the test results, bond failure is predicted based on the distress caused by cracks when they propagate within the transfer zone of prestressing strand. The current code equation was found to be conservative in comparison with the measured value.

프리텐션 프리스트레스트 콘크리트 부재의 정착길이 평가 (Experimental study on development length of prestressing strand in pretensioned prestressed concrete members)

  • 김의성
    • 건설안전기술
    • /
    • 통권49호
    • /
    • pp.84-91
    • /
    • 2009
  • By bond mechanism between the prestressing strand and the concrete surrounding it, the effective force of prestressing must be transferred to the concrete entirely. The distance required to transfer the effective force of prestressing is called the transfer length, and the development length is the bond length required to anchor the strand as it resists external loads on the member. Transfer length was determined from the concrete strain profile at the level of the strands at transfer and development length was determined from various external loading lengths and compared with current code equation. Through the test results, bond failure is predicted based on the distress caused by cracks when they propagate within the transfer zone of prestressing strand. The current code equation was found to be conservative in comparison with the measured value.

  • PDF

직접인발실험에 의한 FRP Tendon의 정착 길이 산정에 관한 연구 (A Study on the Development Length of Fiber Reinforced Polymer Tendon by Direct Pullout Test)

  • 이승주;정우태;박영환;황금식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.837-840
    • /
    • 2006
  • This paper presents the experimental results on the development length of FRP tendons by direct pullout test. Two types of FRP tendons, namely, CFCC tendon and KICT tendon, and PS tendon were investigated. The development length defined as the minimum embedment length required to develop the ultimate tensile strength was suggested using the test results. It was found that the development length from the direct pullout test was greater than those of various standards. This may result from the fact that the wedge effect does not exist because there is no prestressing force in the direct pullout test. Further study and experiment are necessary to derive the reasonable development length for FRP tendon.

  • PDF

고강도 콘크리트 휨부재의 정착 및 겹침이음길이에 관한 실험적 연구 (Experimental Research on Development and Splices Length in High-Strength Concrete Flexural Members)

  • 이기열;김우;정기오
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.865-871
    • /
    • 2003
  • This paper presents the test results of 24 beam-end specimens to investigate the effect of concrete strength and cover thickness on the development resistance capacity in tensile lap splice length regions. The results showed that as higher strength concrete was employed, nor only development resistance capacity was influenced by cover thickness, but also more sufficient safety factor reserved shorter than the lap splice length provision in current design code. From experimental research results, high-strength concrete development length was not inverse ratio of ($\sqrt{f_{ck}}$) but directly inverse of $f_{ck}$, and it is also said that there is a certain limit length of the embedded steel over which the assumption of uniform bond stress distribution is valid specially for high-strength concrete not having a same embed length such as normal-strength concrete in current design criteria hypothesis.

  • PDF

The Morphological Study of Wild and Farmed Olive Flounder (Paralichthys olivaceus): The Role of Indirect Selection within and between Populations

  • Park, Jong-Won;Lee, Young-Mee;Noh, Jae-Koo;Kim, Hyun-Chul;Park, Choul-Ji;Hwang, In-Joon;Kim, Sung-Yeon;Lee, Jeong-Ho
    • 한국발생생물학회지:발생과생식
    • /
    • 제16권4호
    • /
    • pp.309-314
    • /
    • 2012
  • This study was conducted to analyze the difference of body types within and between wild and farmed populations of olive flounder Paralichthys olivaceus using measured records of morphological traits. The results showed that surveyed traits and standard deviation were $1,355{\pm}742g$ of body weight, $48.01{\pm}7.79cm$ of total length, and $40.96{\pm}6.80cm$ of body length. Also body height, body shape index and condition factor were $17.19{\pm}3.43cm$, $9.99{\pm}0.74$ and $11.16{\pm}1.54$, respectively. As result of least squares mean and standard error for each trait assumed in this study, those of farmed population showed significantly higher than those of wild population in all traits, exclusively in total length and body length (p<0.01). Particularly, the values of the body height and the body weight of the farmed population were higher than those of the wild population in the same total length. And the phenotypic correlation coefficients of the body weight, the total length, the body length and the body height showed strong positive correlation in all populations. These result suggested that morphological differences exist in farmed and wild flounder. Therefore, introduction of wild flounder is essential for the future production to improve the body type of farmed flounder, and parental fish should be chosen by considering selection of commercially important traits in the production process.

20db 정착길이를 가지는 SD700 갈고리철근과 확대머리철근의 정착성능 실험 (Anchorage performance tests of SD700 hooked bar and headed bar with a anchorage length of 20db)

  • 김호영;심혜정
    • 도시과학
    • /
    • 제7권2호
    • /
    • pp.21-27
    • /
    • 2018
  • With the increase of the skyscraper center, the development of large-diameter and high-strength reinforcing bars is being carried out to solve the dense reinforcement. In case of the steel reinforced concrete with a small cross section such as beam-column joints, the development length becomes short when straight bars are used. Therefore, it is possible to solve the problem that the development length becomes short by using the bearing strength of the hooked bar and headed bar. In this study, the exterior beam-column joint test of SD700 hooked bar and headed bar with anchorage length of 20db was conducted to extend the development length limitation of hooked bar and headed bar. As a result of the evaluation of the anchorage strength using the design equation by KCI, the average of the [measured value]/[predicted value] ratio was 1.31 for the hooked reinforcing bars. In the case of headed bars, the average of the [measured value]/[predicted value] ratio was 1.12. In addition, in order to compare the anchorage performance of the hooked bar and the headed bar, the measured values were divided by the square root of the compressive strength of the concrete to compare the anchorage strength. Under the same conditions, the anchorage strength of headed bars was 8.5% higher than the hooked bars.

Bond mechanism of 18-mm prestressing strands: New insights and design applications

  • Dang, Canh N.;Marti-Vargas, Jose R.;Hale, W. Micah
    • Structural Engineering and Mechanics
    • /
    • 제76권1호
    • /
    • pp.67-81
    • /
    • 2020
  • Pretensioned concrete (PC) is widely used in contemporary construction. Bond of prestressing strand is significant for composite-action between the strand and concrete in the transfer and flexural-bond zones of PC members. This study develops a new methodology for quantifying the bond of 18-mm prestressing strand in PC members based on results of a pullout test, the Standard Test for Strand Bond (STSB). The experimental program includes: (a) twenty-four pretensioned concrete beams, using a wide range of concrete compressive strength; and (b) twelve untensioned pullout specimens. By testing beams, the transfer length, flexural-bond length, and development length were all measured. In the STSB, the pullout forces for the strands were measured. Experimental results indicate a significant relationship between the bond of prestressing strand to the code-established design parameters, such as transfer length and development length. However, the code-predictions can be unconservative for the prestressing strands having a low STSB pullout force. Three simplified bond equations are proposed for the design applications of PC members.

농촌지역주민 공동체의식의 지역사회참여 영향요인 - 거주기간의 조절효과 - (Factors Influencing Community Participation: Moderating Effects on Length of Residency)

  • 박덕병;임광명;안재문
    • 농촌지도와개발
    • /
    • 제25권3호
    • /
    • pp.135-148
    • /
    • 2018
  • Sense of community and length of residence are important variables influencing community participation. The study aims to identify the factors influencing community participation on sense of community. Particularly, the study examine the moderating effects on the length of residency between sense of community and community participation. Data were collected from 130 usable questionnaires among residents of rural villages. Results of a factor analysis yielded three dimensions of sense of community which are solidarity, belonging, and emotional intimacy. Results show that all of factors among three dimensions of sense of community have significance for community participation. And length of residency has a positive effects as a moderator between community capacity and community satisfaction. Results also indicated that length of residence has an negative interactional effects with moderator. It means that even though higher belonging, less community participation if people live in longer their community. It was suggested that sense of community and length of residency should be considered in rural community development policy.

인장을 받는 고강도철근콘크리트 부재의 정착성능 평가 (Development Properties of Rebar in Tension with High Strength Concrete)

  • 박수희;이범식;김상연;박성식;배기선;김성덕
    • 토지주택연구
    • /
    • 제2권1호
    • /
    • pp.53-60
    • /
    • 2011
  • 인장을 받는 고강도콘크리트 부재의 정착특성을 평가하고 KCI 2007 정착길이 산정기준의 적용가능성을 평가하기 위하여 콘크리트강도와 정착길이, 섬유혼입률을 변수로 한 정착실험을 수행하였다. 정착실험 수행 결과, 인장을 받는 80MPa의 고강도콘크리트 부재에서 KCI 2007의 최소정착길이의 적용이 가능할 것으로 기대된다. 고강도콘크리트의 내화성능을 확보하기 위하여 혼입되는 섬유(NY+PP)는 0.1%까지 혼입하여도 고강도콘크리트의 정착특성에 영향을 미치지 않는 것으로 나타났다.