• Title/Summary/Keyword: Development factor

Search Result 10,324, Processing Time 0.037 seconds

Estimation of Contact Stress Distribution Factor in Bolt Joint with variable Fastening torque (체결력에 따른 볼트 결합부의 접촉응력분포계수 평가)

  • 김종규
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.2
    • /
    • pp.73-79
    • /
    • 1999
  • Most of mechanical structures are combined of substructures such as beams and/or plates. There are few systems with unibody structures but are many systems with united body structures. Generally the dynamic a nalysis of whole structures is performed under alternation load. In the structure design, the analysis of each bolted joint is more important than others for zero severity. This paper presents the analysis method of contact stress distribution factor in the bolted joint with variable fastening torque on joints in the structure. At first, a static vibration test was performed to find out a nominal stress of bolt jointed plates from the relationship between natural frequency and nominal stress. Then a contact stress was computed at contact point between bolt and plate in the structure. It is believed that the proposed method has promisiong implications for safer design with index of contact stress distribution factor and has merits for cost-down and saving time at the beginning of vehicle development.

  • PDF

A Study on the Development of the Charging-Discharging System with High Power Factor and High Efficiency (고역율, 고효율 충.방전기 개발에 관한 연구)

  • Kim, Eun-Soo;Joe, Kee-Yeon;Byun, Young-Bok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.568-572
    • /
    • 1994
  • This paper presents equipment for charging and discharging with high power factor aid high efficiency. This equipment is consisted of $3{\phi}$SPWM AC/DC converter for improving input current waveform and input power factor, and bidirectional DC/DC converter for electric isolation in the DC link Part. Therefore, Input power factor and the total efficiency in the proposed system can be increased more than in the conventional phase-controlled thyristor Charging - Discharging System.

  • PDF

Recommended Practice for Demand Factor and Maximum Utilization Factor by Feature Parameters and Regression Analysis depending on Power Consumption Characteristics in Office Buildings (사무소용빌딩의 전력소비특성을 고려한 특징파라메터 및 회귀분석을 통한 수용률과 변압기최대이용률 비교 분석)

  • Kim, Se-Dong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.241-244
    • /
    • 2007
  • It is increased electrical energy consumption with the development of intelligence society in office buildings and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 132 office buildings. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried linear and nonlinear regression analysis.

  • PDF

A study on the piezoelectric characteristics of PMB-PZT ceramics for piezoelectric transformer material development (압전트랜스용 재료 개발을 위한 PMB-PZT계 세라믹의 압전특성에 관한 연구)

  • Kim, Hyun-Chul;Kim, Seung-Cheol;Bae, Seon-Gi;Kim, Jean-Shop;Yoon, Hyun-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.578-580
    • /
    • 2002
  • In this thesis, specimens was manufactured in general method annexing PMB-PZT system ceramic, and the following conclusion has been deduced. In XRD, the crystal structure of ceramic has the tetragonal structure which is close to rombohedral structure, and consequently the specimen characterized by MPB was manufactured. According to dopping with xPMB, electromechanical factor(kp) little is changed. kp was maximum value 23.37[%] at xPMB 0.03[mol%]. mechanical quality factor(Qm) was maximum value 237,04 at xPMB 0.03[mol%].

  • PDF

Development of Health Behavior Assessment Tool of the Korean Adults (성인의 건강행위 측정도구 개발연구)

  • 김애경
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.3
    • /
    • pp.540-549
    • /
    • 1998
  • This study has been designed to develop a health behavior scale. Data were collected through a survey over a period of two month period. Subjects who participated in the study were 298 Korean adults. The author used a convenience sampling method. The analysis of the data was done with SPSS PC for descriptive statistics and factor analysis. Initially 34 items were generated from the interview data of twenty one adults and from literature review and survey. This preliminary scale was analyzed for a reliability and validity. The results are as follow : 1. Crombach Coefficient alpha for the 30 items was .7907. 2. Factor analysis was done in order to confirm construct validity and nine factor were extracted from the results. These contributed 54.4% of the variance in the total score. 3. Nine factor label were 'exercise' 'stress management' 'energy conservation' 'limit in liking' 'selection of food' 'ingestion of natural food' 'health examination' 'relaxation' and 'nutrition'. The author suggests that this scale could be adequately applied in assessing the health behavior of Korean adults. The results of using this scale in a study can contribute to designing an appropriate health promotion strategy.

  • PDF

EXPERIMENTAL STUDY ON THE HEAVY-DUTY GAS TURBINE COMBUSTOR (산업용 가스터빈 연소기에 대한 실험적 연구)

  • Antonovsky, V.;Ahn, Kook-Young
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.142-149
    • /
    • 2000
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed in the scale 1:1. The model experiments were executed at a pressure smaller than in the real gas turbine. The combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure, and NOx emission were measured at partial and full load for both model and on-site testing. The comparison of these items of information, received on similar modes in the stand and field tests, has allowed the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

The Effects of Residents' Perceptions of Tourism Impact and Conflicts on Residents' Participation in Rural Tourism Village (농촌관광마을사업에 대한 관광영향 지각 및 갈등이 주민참여에 미치는 영향)

  • Joo, Young-Min;Park, Duk-Byeong
    • Journal of Agricultural Extension & Community Development
    • /
    • v.15 no.4
    • /
    • pp.577-597
    • /
    • 2008
  • The purpose of this study is to examine the effects of residents' perceptions of tourism impact and conflicts on residents' participation in rural tourism village. Method of analysis involves factor analysis and regression analysis in this study. In order to measure the level of perception, three factors(economic benefits, social benefits, social and environmental cost) are derived from the factor analysis. And also in order to measure the level of conflict, two factor(openness of information, leading of operation) are derive from the factor analysis. The result of regression analysis indicate that perceived economic benefits and social benefits are rather greater impacts on residents' participation than social and environmental cost, and also openness of information is rather greater impacts on residents' participation than leading of operation.

  • PDF

Development and Validation of the Resilience Scale for Children in Grade 4 Trough 6(RSC) (아동용 탄력성 척도 개발 및 타당화 : 초등학교 4-6학년용)

  • Ju, Soyoung;Lee, Yanghee
    • Korean Journal of Child Studies
    • /
    • v.28 no.2
    • /
    • pp.91-113
    • /
    • 2007
  • The purpose of this study was to develop the Resilience Scale for Children(RSC) and to evaluate its reliability and validity. The RSC was administered to 482 children in grades 4 through 6. Factor analysis of the 30 item scale demonstrated Cronbach's ${\alpha}=.89$ for internal consistency of total items. The results of the confirmatory factor analysis supported a five-factor structure. Retest stability was acceptable for the five-factors. Tests of the present scale for criterion-related validity compared favorably with Self-Perception Profile for Children (Lee, et al., 1992) and the Stress Coping Behavior Scale for Children (Kim and Kang, 2003) confirming its applicability to elementary school students for assessment of resilience.

  • PDF

Model and Field Testing of a Heavy-Duty Gas Turbine Combustor

  • Ahn, Kook-Young;Kim, Han-Seok;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.9
    • /
    • pp.1319-1327
    • /
    • 2001
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed 1:1 scale. The model experiments were executed at a lower pressure than that in a real gas turbine. Combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure and NOx emission were measured at partial and full loads for both model and on-site testing. The comparison of these items in the stand and field test results led to has the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

Development of the Boated Length to Diameter Correction Factor on Critical Heat Flux Using the Artificial Neural Networks

  • Lee, Yong-Ho;Chun, Tae-Hyun;Beak, Won-Pil;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.443-448
    • /
    • 1998
  • With using artificial neural networks (ANNs), an analytical study related to the heated length effect on critical heat flux(CHF) has been carried out to make an improvement of the CHF prediction accuracy based on local condition correlations or table. It has been carried out to suggest a feasible criterion of the threshold length-to-diameter (L/D) value in which heated length could affect CHF. And within the criterion, a L/D correction factor has been developed through conventional regression. In order to validate the developed L/D correction factor, CHF experiment for various heated lengths have been carried out under low and intermediate pressure conditions. The developed threshold L/D correlation provides a new feasible criterion of L/D threshold value. The developed correction factor gives a reasonable accuracy fur the original database, showing the error of -2.18% for average and 27.75% for RMS, and promising results for new experimental data.

  • PDF