• Title/Summary/Keyword: Determination technology

Search Result 3,546, Processing Time 0.028 seconds

Determination of Vitamin C in Chewing Gum Using Extraction by Tetrahydrofuran (테트라하이드로퓨란에 의한 추출방법을 이용한 츄잉검의 비타민 C 정량)

  • Roh, Hoe-Jin;Kim, Pil;Park, Cheon-Ho;Lee, Kee-Jung;Noh, Bong-Soo;Choi, Jin-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.1484-1487
    • /
    • 1999
  • Extraction is the most important and tedious step to determine water-soluble vitamin C in water-insoluble chewing gum. For the rapid determination of vitamin C in chewing gum, a new method of dispersion in tetrahydrofuran(THF) was performed. Vitamin C was easily extracted from gum base using THF The content of vitamin C in chewing gum was rapidly quantified with high reliability by an enzymatic method using a chewing gum sample dispersed in tetrahydrofuran.

  • PDF

Investigation and Testing of Location Systems Using WiFi in Indoor Environments

  • Retscher, Guenther;Mok, Esmond
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.83-88
    • /
    • 2006
  • Many applications in the area of location-based services and personal navigation require nowadays the location determination of a user not only in outdoor environment but also indoor. To locate a person or object in a building, systems that use either infrared, ultrasonic or radio signals, and visible light for optical tracking have been developed. The use of WiFi for location determination has the advantage that no transmitters or receivers have to be installed in the building like in the case of infrared and ultrasonic based location systems. WiFi positioning technology adopts IEEE802.11x standard, by observing the radio signals from access points installed inside a building. These access points can be found nowadays in our daily environment, e.g. in many office buildings, public spaces and in urban areas. The principle of operation of location determination using WiFi signals is based on the measurement of the signal strengths to the surrounding available access points at a mobile terminal (e.g. PDA, notebook PC). An estimate of the location of the terminal is then obtained on the basis of these measurements and a signal propagation model inside the building. The signal propagation model can be obtained using simulations or with prior calibration measurements at known locations in an offline phase. The most common location determination approach is based on signal propagation patterns, namely WiFi fingerprinting. In this paper the underlying technology is briefly reviewed followed by an investigation of two WiFi positioning systems. Testing of the system is performed in two localization test beds, one at the Vienna University of Technology and the second at the Hong Kong Polytechnic University. First test showed that the trajectory of a moving user could be obtained with a standard deviation of about ${\pm}$ 3 m.

  • PDF

Simultaneous Determination of Synthetic Phosphodiesterase-5 Inhibitors in Dietary Supplements by Liquid Chromatography-High Resolution/Mass Spectrometry

  • Kim, So-Hee;Kim, Ho-Jun;Son, Jung-Hyun;Jeon, Byoung-Wook;Jeong, Eun-Sook;Cha, Eun-Ju;Lee, Jae-Ick
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.50-53
    • /
    • 2012
  • After success of sildenafil for the treatment of erectile dysfunction, a large number of its analogues have been approved from FDA. Recently, the illegal dietary supplements which include sildenafil, vardenafil, tadalafil, or analogues of these drugs as ingredient have been widely distributed. Therefore, the determination of the residue of synthetic phosphodiesterase- 5 (PDE-5) inhibitors in dietary supplements is highly required due to indiscriminate and unintentional overdose caused nausea, chest pains, fainting and irregular heartbeat. In this paper, we report a rapid and sensitive analytical method for the simultaneous determination of nine phosphodiesterase-5 inhibitors by liquid chromatography-high resolution mass spectrometry. The present method was found to be accurate and reproducible with 40 ${\mu}g$/g of the limit of quantification for the nine PDE-5 inhibitors. The developed method can be successfully applied to the analysis of the seven illegal dietary supplements.

DEVELOPMENT OF ANODIC STRIPPING VOLTAMMETRY FOR THE DETERMINATION OF PALLADIUM IN HIGH LEVEL NUCLEAR WASTE

  • Bhardwaj, T.K.;Sharma, H.S.;Jain, P.C.;Aggarwal, S.K.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.8
    • /
    • pp.939-944
    • /
    • 2012
  • Deposition potential, deposition time, square wave frequency, rotation speed of the rotating disc electrode, and palladium concentration were studied on a Glassy Carbon Electrode (GCE) in 0.01M HCl for the determination of palladium in High Level Nuclear Waste (HLNW) by anodic stripping voltammetry. Experimental conditions were optimized for the determination of palladium at two different, $10^{-8}$ and $10^{-7}M$, levels. Error and standard deviation of this method were under 1% for all palladium standard solutions. The developed technique was successfully applied as a subsidiary method for the determination of palladium in simulated high level nuclear waste with very good precision and high accuracy (under 1 % error and standard deviation).

Determination of Methyl Bromide Used for the Preservation of Cultural Materials from Insects

  • Lee, Gil-Seung;Shin, Ueon-Sang;Shin, Ho-Sang
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.4
    • /
    • pp.27-30
    • /
    • 2002
  • A thermal desorption-gas chromatography/mass spectrometric method was developed for the determination of methyl bromide in fumes formed during preservation of cultural materials from insects. Methyl bromide in lunes was collected by drawing 10ι of air through the adsorbent tube filled with a solid adsorbent (Chromosorb). The air samples were analyzed by using a special thermal desorption device and GC/MS determination. The recovery of methyl bromide by air sampling was 88% and the detection limit of the assay was 0.1 pptv based upon assayed air of 10ι. The method was applied to the determination of fumed methyl bromide used for the preservation of papers in a library. The mean concentration of methyl bromide determined in a library was 280.2 $\pm$ 25.4 pptv.

Simultaneous Determination of Salicylic Acid and Aspirin in Commercial Aspirin Tablets

  • Kim, Chong-Kook;Hwang, Sung-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.12 no.4
    • /
    • pp.126-131
    • /
    • 1982
  • A quantitative fluorometric method was developed to determine aspirin and salicylic acid in bulk aspirin and commercial aspirin tablets. The excitation maximum for aspirin was observed at 280 nm and the emission maximum was at 335nm. The lowest energy excitation band for salicylic acid was at 308nm and the fluorescence emission band was at 450nm. Excipients, binders, lubricants and impurities did not interfere. Excellent recoveries were obtained for aspirin and salicylic acid. Results obtained by the KP III procedure and the proposed method were compared.

  • PDF

Shape determination of 3-D reinforcement corrosion in concrete based on observed temperature on concrete surface

  • Kurahashi, Takahiko;Oshita, Hideki
    • Computers and Concrete
    • /
    • v.7 no.1
    • /
    • pp.63-81
    • /
    • 2010
  • We present the shape determination method of 3-D reinforcement corrosion based on observed temperature on concrete surface. The non-destructive testing for reinforcement corrosion in concrete using a heat image on concrete surface have been proposed by Oshita. The position of the reinforcement of corrosion or the cavity can be found using that method. However, the size of those defects can not be precisely measured based on the heat image. We therefore proposed the numerical determination system of the shape for the reinforcement corrosion using the observed temperature on the concrete surface. The adjoint variable method is introduced to formulate the shape determination problem, and the finite element method is employed to simulate the heat transfer problem. Some numerical experiments and the examination for the number of the observation points are shown in this paper.

A Study on the Improvement of Scaling Factor Determination Using Artificial Neural Network (인공신경망 이론을 이용한 척도인자 결정방법의 향상방안에 관한 연구)

  • Sang-Chul Lee;Ki-Ha Hwang;Sang-Hee Kang;Kun-Jai Lee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.35-40
    • /
    • 2004
  • Final disposal of radioactive waste generated from Nuclear Power Plant (NPP) requires the detailed information about the characteristics and the quantities of radionuclides in waste package. Most of these radionuclides are difficult to measure and expensive to assay. Thus it is suggested to the indirect method by which the concentration of the Difficult-to-Measure (DTM) nuclide is estimated using the correlations of concentration - it is called the scaling factor - between Easy-to-Measure (Key) nuclides and DTM nuclides with the measured concentration of the Key nuclide. In general, the scaling factor is determined by the log mean average (LMA) method and the regression method. However, these methods are inadequate to apply to fission product nuclides and some activation product nuclides such as 14$^{C}$ and 90$^{Sr}$ . In this study, the artificial neural network (ANN) method is suggested to improve the conventional SF determination methods - the LMA method and the regression method. The root mean squared errors (RMSE) of the ANN models are compared with those of the conventional SF determination models for 14$^{C}$ and 90$^{Sr}$ in two parts divided by a training part and a validation part. The SF determination models are arranged in the order of RMSEs as the following order: ANN model

  • PDF

Simultaneous Determination of Glucose and Ethanol of Takju by Biosensor using Dual Cathode Electrode (Dual Cathode Electrode를 이용한 바이오센서로 탁주 중의 포도당 및 에탄올의 동시 측정)

  • Park, In-Seon;Kim, Jung-Ho;Kim, Tae-Jin;Kim, Nam-Soo;Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.974-980
    • /
    • 1996
  • A biosensor was prepared with dual cathode electrode and immobilized enzyme membrane. A nylon net was used for the immobilization of glucose oxidase and alcohol oxidase. The immobilized enzymes were placed on the surface of the electrode which was prepared with one anode and two cathodes as an oxygen electrode. The determination of components by the biosensor was based on the consumption of dissolved oxygen. The optimum condition of this system was 0.1 M potassium phosphate buffer solution, pH 7.5 at $35^{\circ}C$. Glucose and ethanol in takju were simultaneously determined by the biosensor. Comparing with UV-spectrophotometer and gas chromatograph for cross checking, there was a good correlation between the biosensor and the conventional methods. Biosensor with dual cathode electrode required no clarification or pretreatments. It was used for simultaneous determination of glucose and ethanol during the fermentation of takju.

  • PDF

The Tool Path Determination for Machining the Plane Curve by an Adaptive Mesh Generation Technique - Comparision among the Adaptive Linear Interpolation, Parabolic Interpolation & Linear-Parabolic Interpolation Method - (적응요소분할법에 의한 평면곡선가공의 공구경로 결정 - 적응요소직선보간과 적응요소포물선보간 및 혼합보간법의 비교 -)

  • Hyun, Chang-Heon
    • Journal of Industrial Technology
    • /
    • v.12
    • /
    • pp.69-76
    • /
    • 1992
  • An attempt has been made to determination the NC milling machine's tool-path through the adaptive parabolic interpolation method & the adaptive linear-parabolic interpolation method in consideration of the economical machining time. The algorithms for the above-mentioned interpolation methods have been designed and the numerical experiments for these methods have been conducted with the existing adaptive linear interpolation methods for comparision.

  • PDF