• Title/Summary/Keyword: Determination of cobalt

Search Result 46, Processing Time 0.022 seconds

Use of High Molecular Alkylamines in the Simultaneous Determination of Copper and Cobalt by Spectrophotometry (구리와 코발트의 분광광도법에 의한 정량에 있어서 고분자량 알킬아민의 이용)

  • Chon Han Kim;Chan Ho Jee;Ki Tae Sung;Chang Ung Joung
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.208-214
    • /
    • 1989
  • A method for the simultaneous determination of copper and cobalt by spectrophotometry has been described. The procedure involves the co-extraction of Cu(Ⅱ) and Co(Ⅱ) from 0.3M HCl into methyl isobutyl ketone as the ion-pairs formed between their thiocyanate complexes and high molecular alkylamines such as Amberlite LA1, Alamine 336, and Aliquat 336. The extract shows the color development to have the maximum absorbances at two different wavelengths i.e., 480 nm for copper and 625 nm for cobalt. Since the spectra of the ion-pairs overlap each other, two simultaneous equations are used to obtain the concentrations from absorbances. Even small amount of Fe(Ⅲ) and Ni(Ⅱ) interferes with the determination of copper. The results of the analysis of samples are in good agreement with the results determined by separate methods within RSD 5.9%.

  • PDF

Column Preconcentration and Determination of Cobalt(II)Using Silica Gel Loaded with 1-Nitroso-2-naphthol

  • Shin, Eun-Mi;Choi, Hee-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.7
    • /
    • pp.1516-1520
    • /
    • 2009
  • A sensitive technique for the determination of trace Co(II) in various samples after column preconcentration by adsorbing onto silica gel loaded with 1-nitroso-2-naphthol was developed. Several experimental conditions, such as pH of sample solution, the amount of silica gel loaded with 1-nitroso-2-naphthol, the flow rate for adsorption and so forth, were optimized. The interfering effects of diverse concomitant ions were investigated. Fe(III) interfered with more than any other ions, but the interference by Fe(III) was completely eliminated by adjusting the amount of silica gel loaded with 1-nitroso-2-naphthol to 0.30 g. The dynamic range, the correlation coefficient ($R^2$), and the detection limit obtained by the proposed technique were 3.0-140.0 ng m$L^{-1}$, 0.9942, and 1.81 ng m$L^{-1}$, respectively. For validating the technique, the aqueous samples (tap water, reservoir water, stream water, and wastewater) and the plastic samples were used as real samples. Recovery yields of 93.0-107.0% were obtained. These measured data were not different from ICP-MS data at the 95% confidence level by F test. Based on the results of the experiment, it has been found that the proposed technique can be applied to the determination of Co(II) in various real samples.

Determination of Inorganic Phosphate in Paprika Hydroponic Solution using a Laboratory-made Automated Test Stand with Cobalt-based Electrodes (코발트전극과 자동시험장치를 이용한 파프리카 양액 내 무기인산 측정)

  • Kim, Hak-Jin;Son, Dong-Wook;Kwon, Soon-Goo;Roh, Mi-Young;Kang, Chang-Ik;Jung, Ho-Seop
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.326-333
    • /
    • 2011
  • The need for rapid on-site monitoring of hydroponic macronutrients has led to the use of ion-selective electrodes, because of their advantages over spectrophotometric methods, including simple methodology, direct measurement of analyte, sensitivity over a wide concentration range, and low cost. Stability and repeatability of response can be a concern when using multiple ion-selective electrodes to measure concentrations in a series of samples because accuracy might be limited by drifts in electrode potential. A computer-based measurement system could improve accuracy and precision because of both consistent control of sample preparation and easy calibration of sensors. Our goal was to investigate the applicability of a cobalt-based electrode used in conjunction with a laboratory-made automated test stand for quantitative determination of ${PO_4}^-$ in hydroponic solution. Six hydroponic solutions were prepared by diluting highly concentrated paprika hydroponicsolution to provide a concentration range of 1 to 300 ppm $PO_4$-P. A calibration curve relating electrode response to phosphate in paprika hydroponic solution titrated to pH 4 with 0.025M KHP was developed based on the Nikolskii-Eisenman equation with a coefficient of determination ($R^2$) of 0.94. The laboratory-made test stand consisting of three cobalt-based electrodes measured phosphate concentrations similar to those obtained with standard laboratory methods (a regression slope of 0.98 with $R^2$ = 0.80). However, the y intercept was relatively high, 30 ppm, probably due to the relatively large amount of variation present among multiple measurements of the same sample. Further studies on the high variation in EMFs obtained with cobalt electrodes during replicate measurements were required for P estimations comparable to those obtained with standard laboratory instruments.

CYP1A1 GENE EXPRESSION IS DOWN REGULATED BY HYPOXIC AGENTS

  • Joung, Ki-Eun;Kim, Yeo-Woon;Syrie Pang;Sheen, Yhun-Yhong
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2001.11a
    • /
    • pp.114-114
    • /
    • 2001
  • Since hypoxia-inducible factor-lalpha (HIF-lalpha) and the arylhydrocarbon receptor (AhR) shared the AhR nuclear translocator (Arnt) for hypoxia- and AhR-mediated signaling, respectively, it was possible to establish the hypothesis that hypoxia could regulate Cyplal expression. In order to understand the mechanism of Cyplal gene expression, we demonstrated here that hypoxic agents such as cobalt chloride, desferrioxarnine, and picolinic acid reduced the TCDD induced Cyplal promoter activity based on the determination of luciferase activity in Hepa I cells transfected with pmCypla1-Luc. Also cobalt chloride inhibited the TCDD stimulated Cyplal mRNA level as well as EROD activities in both Hepa I and MCF-7 cells. Hypoxic agents such as cobalt chloride, picolinic acid, and desferrioxamine showed inhibition of luciferase activity that was induced by lnM TCDD treatment with dose dependent manner. Concomitant treatment of 150${\mu}$M ferrous sulfate with 1∼100${\mu}$M desferrioxarnine or 1∼100${\mu}$M picolinic acid recovered from the hypoxic agents-inhibited luciferase activity that was stimulated by TCDD. Reciprocally, the hypoxic agents down regulated TCDD induced Cyplal mRNA level and CYP1A1 enzyme activity in Hepa I cells.

  • PDF

Study on Determination of Seven Transition Metal Ions in Water and Food by Microcolumn High-Performance Liquid Chromatography

  • Hu, Qiufen;Yang, Guangyu;Li, Haitao;Tai, Xi;Yin, Jiayuan
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.694-698
    • /
    • 2004
  • A new method for the simultaneous determination of seven transition metal ions in water and food by microcolumn high-performance liquid chromatography has been developed. The lead, cadmium, mercury, nickel, cobalt, silver and tin ions were pre-column derivatized with tetra-(4-aminophenyl)-porphyrin ($T_4$-APP) to form the colored chelates which were then enriched by solid phase extraction with $C_{18}$ cartridge. The enrichment factor of 50 was achieved by eluted the retained chelates from the cartridge with tetrahydrofuran (THF). The chelates were separated on a ZORBAX Stable Bound microcolumn ($2.0{\times}50\;mm,\;1.8\;{\mu}m$)with methanol-tetrahydrofuran (95 : 5, v/v, containing 0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0) as mobile phase at a flow rate of 0.5 mL/min and detected with a photodiode array detector from 350-600 nm. The seven chelates were separated completely within 2.0 min. The detection limits of lead, cadmium, mercury, nickel, cobalt, silver and tin are 4 ng/L, 3 ng/L, 6 ng/L, 5 ng/L, 5 ng/L, 6 ng/L, 4 ng/L respectively in the original samples. This method was applied to the determination of the seven transition metal in water and food samples with good results.

Spectrophotometric Determination of Platinum (IV) with 2-Oximino-1-indanone (2-Oximino-1-indanone을 이용한 Pt(IV) ion의 정량에 관한 연구)

  • 김정균;유미경;원미숙;심윤보;고영심
    • YAKHAK HOEJI
    • /
    • v.28 no.2
    • /
    • pp.61-67
    • /
    • 1984
  • A method is described for the spectrophotometric determination of platinum (IV) with 2-oximino-1-indanone based on solvent extraction of Pt:2-oximino-1-indanone complex. The 2-oximino-1-indanone reacted with Pt(IV) to form a dark-orange complex which shows a characterisic maximum absorption at 342nm. The optimum PH for the platinum extraction lies between 5.4~8.0. Beer's law obeys up to 0.98-16.3ppm of platinum (IV) and the molar absorption coefficient is $1.06{\times}10^{-4}L.mol^{-1}.cm^{-1}$. The relative standard deviation of the method was $\times2.1%$. The composition of the complex is estimated to be Pt : In= 1 : 1, by the mole ratio method and ion exchange resin experiment. The optimum condition for the determination of platinum has been studied in detail. The 2-oximin-1-indanone is found to be a selectivereagent for the determination of platinum, since the synthesixed 2-oximino-1-indanone did not react with other metals such as cobalt, cadmium, copper, manganese nickel, iron, lead and zinc, to form the complex. In this studies, we have also clarified Sindhwani and Singh's spectrophotometric determination data of various metals with acenaphthenequinone monooxime (Talanta 20,248, 1973), whose results were not correct.

  • PDF

Development of Electro-Biosensor for the Residual Pesticides using Organic Carbon and Cobalt Phthalocyanine (Cobalt Phthalocyanine 탄소유기 전극을 이용한 농약 잔류량 측정 센서개발)

  • Yu, Young-Hun;Cho, Hyung-Jun;Park, Won-Pyo;Hyun, Hae-Nam
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.1
    • /
    • pp.72-76
    • /
    • 2010
  • We have developed the bio-electrode measuring the variance of the amount of acetylcholine affected by residual pesticide. The working electrode of the biosensor was made by combination of cobalt phthalocyanine and carbon organic compounds. The biosensors were constructed by screen-printing method. The principle of working electrode is similar to thiocholine sensor. We have fabricated the biosensor using standard screen printing method. Generally, the biosensor made by printing method formed thick film biosensor. When the electrodes were made by electrochemical cells, the generation of current by the addition of enzyme substrate was inhibited by standard solutions of organo-phosphate pesticides. The detection limit of sensor is about 0.5 $\mu{g}/L$ for carbofuran. We could improve the responsibility of the sensor by controlling the cobalt phthalocyanine and thiocholine concentration ratio. Also we have tested the EPN and Chlorpyrifos pesticides and found that the biosensor is applicable to fast determination of residual pesticides.

Quantitative Analysis of Cobalt with Continuous Flow Preconcentration Using 1-Nitroso-2-naphthol as an Organic Precipitant (1-Nitroso-2-naphthol 침전제를 사용한 연속흐름 선농축법에 의한 코발트의 정량분석)

  • Im, Kab Soo;Pak, Yong Nam
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.6
    • /
    • pp.644-650
    • /
    • 1999
  • Trace amount of cobalt in water samples was preconcentrated continuously with an organic precipitant and determined by flame atomic absorption spectrometry. The flow injection technique was used to preconcentrate cobalt by on-line direct precipitation with 1-nitroso-2-naphthol. The precipitation was dissolved with methyl isobutyl ketone (MlBK) and was sent to the flame. The optimum conditions for cobalt determination were determined and used to analyze Co samples. For 1.0 mL of sample, the enrichment factor was 13 and the sample throughput was about lO per hour for 0.5 ppm Co solution. The enrichment factor was increased to 68 fold for 10.0 mL. A semi-reference biologicaI sample was prepared and analyzed. The result was in good agreement with the expected value with RSD of 4%.

  • PDF

Highly Selective Derivative Spectrophotometry for Determination of Nickel Using 1-(2-Pyridylazo)-2-naphthol in Tween 80 Micellar Solutions

  • Eskandari, Habibollah
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.8
    • /
    • pp.1137-1142
    • /
    • 2004
  • A spectrophotometric and first derivative spectrophotometric method was developed in aquatic Tween 80 micellar solutions for selective determination of nickel without using any pre-separation step. 1-(2-Pyridylazo)-2-naphthol (PAN), as a sensitive chromogenic complexing agent formed a red-colored Ni(II)-PAN complex in Tween 80 media with satisfactory solubility and stability. Conditions such as pH, PAN concentration, type and concentration of micellizing agent were optimized. Molar absorptivity of Ni-PAN complex was found $4.62\;{\times}\;10^4L\;cm^{?1}\;mol^{?1}$ at 569 nm, under the optimum condition. Calibration graphs were derived by zero, first and second derivative spectrophotometry at maximum wavelengths of 569, 578 and 571 nm with linear ranges of 30-1800, 20-2500 and 30-2000 ng $mL^{?1}$ , respectively. Precision as standard deviation as well as accuracy as recovery percent were in the range of 1-20 ng $mL^{?1}$, and 93.3-103.3%, respectively, for the entire of the linear ranges. Spectrophotometric detection limit was 3 ng $mL^{?1}$ and effects of diverse ions on the first derivative determination of nickel were studied to investigate selectivity of the method. Interferences of cobalt and copper on the nickel determination were prevented using o-phenanthroline as masking agent. The recommended procedures were applied to the various synthetic and stainless steel alloys, tea leaves and human hair, with satisfactory results.

Determination of Surface Diffusivities of Oxides by the Combined Sintering (소결에 의한 산화물촉매의 표면확산계수의 측정)

  • 문세기;유경옥;김형진
    • Journal of the Korean Ceramic Society
    • /
    • v.14 no.2
    • /
    • pp.73-77
    • /
    • 1977
  • The surface diffusion coefficients for nickel, nickel oxide, cuppric oxide, cobalt oxide, alumina and ferric oxide have been determined at various temperatures using the sintering technique. This investigation is based on the model accounting for the sum of the contribution of volume and surface diffusion to the overall shrinkage rate during the initial stage of sintering. Simultaneous measurements of shrinkages and shrinkage rates of the materials compacts were conducted for various annealing times, the results of which were then correlated to the diffusion coefficient.

  • PDF