A Comparison of Analytical Methods for the Content and Purity of Cefradine

  • Hyun, Myung-Ho;Jeong, Euh-Duck;Shin, Min-Seob;Jin, Jong-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.1185-1189
    • /
    • 2008
  • Two HPLC methods such as cefadroxil and cefalexin methods were compared in their performance for the quantitative analysis of the content and purity of $\beta$ -lactamic antibiotic, cefradine, for six bulk drug samples. Between the two methods, the cefadroxil method prescribed by the European Pharmacopoeia (EP) for the determination of impurities in cefradoxil was superior to the cefalexin method prescribed by the EP and by the United States Pharmacopeia (USP) for the determination of cefalexin impurity in cefradine in terms of the greater stability of the chromatogram baselines and the higher precision, i.e., the lower % relative standard deviation (RSD). Based on the comparison of the two HPLC methods, the cefadroxil method was recommended to replace the TLC method, which has been prescribed by the EP as the official method for determination of extraneous impurities in cefradine.

Determination of hey Fuel Ratio According to Fuel Composition (IV) - Overall Estimation of Methods- (연료 조성에 따른 공연비 산정 (IV) - 공연비 계산방식의 평가-)

  • Park Chanjun;Ohm Inyong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1155-1162
    • /
    • 2004
  • This paper is the forth paper of several companion papers which compare the method of Air-Fuel ratio determination. In the previous work, various AFR calculations were performed for various fuels and the results were compared with each other. The comparison, however, were limited to numerical value and estimation of each equation or method was insufficient. In this paper, the overall estimation of the methods was attempted. Also, the method of trouble shooting of instrumentation was presented. Through the estimation of methods, it is concluded that the Eltinge method contains inherently the most perfect thermal dissociation model as far as the exhaust composition is concerned; therefore, this might be regarded as the most general equation of AFR determination among the existing ones. The others might be considered as approximate form. In addition, the mal-distribution factor in Eltinge method is qualitatively equivalent to thermal dissociation chemical equilibrium constant K. Lastly, it is illustrated that all instrumentation error, including the sampling line leakage, can be easily detected through the analyzing the exhaust component on the Eltinge chart.

Development of the Seepage flow Monitoring Method by the Hydraulic Head Loss Rate on Sea Dike (수두손실률에 의한 방조제 침투류 감시기법 개발)

  • Eam, Sung-Hoon;Yoon, Chang-Jin;Kim, Seong-Pil;Heo, Jun;Kang, Byung-Yoon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.60-68
    • /
    • 2010
  • In this study, the seepage flow monitoring method by hydaulic head loss rate graph was developed for the purpose of monitoring the seepage flow from the see side or from the lake on sea dike in which seepage force was varied periodically. The hydraulic head loss rate was defined in this method. The value of the rate is in the range from 0 to 1. the value of 0 means perfectly free flow of seepage. the value of 1 means perfect waterproofing. The value of coefficient of determination in the hydraulic head loss rate graph closer to 1 means that the seepage flow way is stable. The value of coefficient of determination in the hydraulic head loss rate graph closer to 0 means that the hole may exist or the piping may be in the progress. The pore water pressure data measured in Saemangeum sea dike was analyzed with the developed method The result showed that the variation of seepage flow state was detected sensitively by this method and the interception effect of sea dike could be estimated quantitatively.

  • PDF

A Study on the Determination of 3-D Object's Position Based on Computer Vision Method (컴퓨터 비젼 방법을 이용한 3차원 물체 위치 결정에 관한 연구)

  • 김경석
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.6
    • /
    • pp.26-34
    • /
    • 1999
  • This study shows an alternative method for the determination of object's position, based on a computer vision method. This approach develops the vision system model to define the reciprocal relationship between the 3-D real space and 2-D image plane. The developed model involves the bilinear six-view parameters, which is estimated using the relationship between the camera space location and real coordinates of known position. Based on estimated parameters in independent cameras, the position of unknown object is accomplished using a sequential estimation scheme that permits data of unknown points in each of the 2-D image plane of cameras. This vision control methods the robust and reliable, which overcomes the difficulties of the conventional research such as precise calibration of the vision sensor, exact kinematic modeling of the robot, and correct knowledge of the relative positions and orientation of the robot and CCD camera. Finally, the developed vision control method is tested experimentally by performing determination of object position in the space using computer vision system. These results show the presented method is precise and compatible.

  • PDF

A Novel Linearization Method of Sin/Cos Sensor Signals Used for Angular Position Determination

  • Zivanovi, Dragan;Lukic, Jelena;Denic, Dragan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1437-1445
    • /
    • 2014
  • In this paper a novel method for angular position determination using sensors with sin/cos output and without an excitation signal, is presented. The linearization of the sensor transfer characteristic and digitalization of the measurement results are performed simultaneously with a goal to increase the measurement resolution. This improvement is particularly important for low angular velocities, and can be used to increase the resolution of incremental Hall, magnetic and optical sensors. This method includes two phases of sin/cos signal linearization. In the first linearization phase the pseudo-linear signal is generated. The second linearization phase, executed by the two-stage piecewise linear ADC, is an additional linearization of the pseudo-linear signal. Based on the LabVIEW software simulations of the proposed method, the contribution of each processing phase to a final measurement error is examined. After the proposed method is applied within $2{\pi}$ [rad] range, the maximal nonlinearity is reduced from 0.3307 [rad] ($18.9447^{\circ}$) to $3{\cdot}10^{-4}$ [rad] ($0.0172^{\circ}$).

Comparison of the Total Nitrogen Determination Methods (총질소 분석방법의 비교)

  • Joung, Kwang-Wook;Yoon, Chun-Gyeong;Ham, Jong-Hwa
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.421-425
    • /
    • 2001
  • Among the many parameters describing water quality, total nitrogen content(TN) is regarded as important one in relation to water quality management of the waterbodies for its role in eutrophication process. This study evaluated for accuracy, convenience and promptness of nitrogen analysis methods : (1)UV spectrophotometric method, (2)summation method, (3)cadmium reduction method. And, the detection limit of each method was calculated using EPA method. The UV spectrophotometric method after oxidation appears to be more convenient and accurate in determination of the TN contents than the summation method and cadmium reduction method. The summation method is necessary to separate determinations of the organic nitrogen, ammonia, nitrite, and nitrate. And, because summation method has many other methods for each contents, it can be detected for wide range of concentration.

  • PDF

Direct and Derivative Spectrophotometric Determination of Cobalt (II) in Microgram Quantities with 2-Hydroxy-3-methoxy Benzaldehyde Thiosemicarbazone (2-Hydroxy-3-methoxy Benzaldehyde Thiosemicarbazone를 사용하여 마이크로 그램 코발트(II)의 직접 및 유도 분광광도법에 의한 정량)

  • Kumar, A.Praveen;Reddy, P.Raveendra;Reddy, V.Krishna
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.4
    • /
    • pp.331-338
    • /
    • 2007
  • A rapid, simple and sensitive spectrophotometric method was developed for the determination of cobalt(II) using 2-hydroxy-3-methoxy benzaldehyde thiosemicarbazone (HMBATSC) as a analytical reagent. The metal ion in aqueous medium forms a brown coloured complex with HMBATSC at pH 6.0. The complex has two absorption maxima at 375 nm and 390 nm. At 375 nm, the reagent shows considerable absorbance, while at 390 nm the reagent does not shows appreciable absorbance. Hence, analytical studies were carried out at 390 nm. Beer's law is obeyed in the range of 0.059-2.357 μg ml-1 of Co(II). The molar absorptivity and Sandall's sensitivity of the method are 2.74×104 l mol-1 cm-1 and 0.0024 μg cm-2 respectively. The interference of various diverse ions has been studied. The complex has 1:2 [Co(II)- HMBATSC] stoichiometry. A method for the determination of cobalt(II) by second order derivative spectrophotometry has also been proposed. The proposed methods were applied for the determination of cobalt(II) in alloy steels, vitamin B12 and in some biological samples.

A Comparison of Orbit Determination Performance for the KOMPSAT-2 using Batch Filter and Sequential Filter (아리랑위성 2호 데이터를 이용한 연속추정필터와 배치필터 처리 결과 비교)

  • Cho, Dong-Hyun;Kim, Hae-Dong
    • Aerospace Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.149-157
    • /
    • 2012
  • In this paper, the performance of the sequential filter for a space debris collision management system is analyzed by using the flight data of KOMPSAT-2. To analyze the performance of the sequential filter, the results of batch filter used in the orbit determination system of the KOMPSAT-2 ground station is used as reference data. The overlap method is also used to evaluate the orbit accuracy. This paper shows that the orbit determination accuracy of the sequential filter is similar to that of the KOMPSAT-2 ground station, but dissimilar characteristics exist due to the filter difference. In addition, it is also shown that the orbit determination accuracy is order of 1m root mean square by using 30 hour GPS navigation solutions and 6 hour comparison period for the overlap method.

Modified Offset Method for Determination of Stable Crack Onset Point on R Curve (R 곡선상의 안정균열개시점 결정을 위한 수정옾셋방법)

  • 안광주;최재강;박준수
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.18-24
    • /
    • 1999
  • This paper were performed to evaluate the elastic-plastic fracture toughness $J_IC$ by the unloading compliance method for 1/2 CT specimen of A5083-H112 aluminum alloy. A modified offset method for negative crack growth effect is presented and compared with Voss offset method. We found that the modified offset method presented can be used efficiently for a determination of the stable crack onset. The $J_IC$ by Voss offset method can be overestimated, but the suggested offset method showed a high reliability within 5% of tolerence from the results by the multi-specimen method.

  • PDF

Determination of the Formation Constants of Metal Complexes with Organic Acids by Adsorption Method (흡착법에 의한 금속이온과 유기산간의 착염 생성계수의 측정법)

  • Jae, Won-Mok
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.4
    • /
    • pp.199-203
    • /
    • 1971
  • The adsorption method for the determination of the formation constants of the metal complexes with organic acids was developed by using membrane filters. The adsorption method involved the measurements of radioactivities of the adsorbed metal on membrane filters and the filtrate solution after the radioactive metal ion were filtered through membrane filters in the presence of organic ions of varying concentration. Comparing the adsorption method with the ion exchange method, it was seen that the adsorption method was simpler and faster than the ion exchange method. As an example of the metal complex with organic acid yttrium citrate complex was chosen, and the formation constant of the complex obtained by the adsorption method showed $K_f=2.0{\times}10^{-4}(l. mole^{-1})$ at a pH of 7. Also the present study revealed that the carrierfree state of yttrium in aqueous solution was present in the completely ionized state.

  • PDF