• Title/Summary/Keyword: Deterioration factors

Search Result 650, Processing Time 0.026 seconds

Characteristics of Cerebral Microbleeds

  • Lee, Juyoun;Sohn, Eun Hee;Oh, Eungseok;Lee, Ae Young
    • Dementia and Neurocognitive Disorders
    • /
    • v.17 no.3
    • /
    • pp.73-82
    • /
    • 2018
  • Cerebral microbleeds (CMBs) are increasingly recognized neuroimaging findings, occurring with cerebrovascular disease, dementia, and aging. CMBs are associated with subsequent hemorrhagic and ischemic stroke, and also with an increased risk of cognitive deterioration and dementia. They occur in the setting of impaired small vessel integrity due to hypertension or cerebral amyloid angiopathy. This review summarizes the concepts, cause or risk factors, histopathological mechanisms, and clinical consequences of CMBs.

Proposed Development and Evaluation System for Existing Standardized Waterproof Technology Assessment Methods(Production technology, maintenance evaluation) (표준화된 방수기술 평가기법 개발 및 평가체계 구축 (생산기술, 유지관리 평가 중심))

  • Song, Je-Young;Seo, Hyun-Jae;Choi, Eun-Kyu;Lee, Jung-Hun;Kim, Byoungil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.235-236
    • /
    • 2019
  • Waterproofing materials and construction methods have been developed and applied to various construction sites since the past. However, there many cases where the waterproofing performance is not satisfactory, leading to continuous water leakage. It has been observed that a key reason for this is because waterproofing method and material selection is not optimized in terms of the appropriate application area and environmental degradation factors. This paper proposes that future selection of waterproofing methods should consider the following evaluation criteria; 1) waterproof performance evaluation according to site conditions, 2) evaluation of construction method, 3) manufacturing and maintenance of waterproofing systems.

  • PDF

A study on the application of TALK-BACK system in a radio communication environment (토크백 시스템 무선통신 적용방안 연구)

  • Yeo, Yong-Joo;Yoon, In-Young;Nam, Joung-In;Choi, Yoon-Seog
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1294-1302
    • /
    • 2008
  • Talk-Back systems comprised of master-equipment at the control room and slave-equipment at turnouts refer to the intercommunication facilities that optimize mutual communication between maintenance staff on trackside and the control room to facilitate quickness and accuracy of train operation control and its maintenance within depot and on mainlines with turnouts for direction switching of the trains in operation. The weakness lies in additional maintenance costs of cables since the Talk-Back system installed on line 1 along with line 2-4 has a profound effect on the voice quality leading to the attenuation and crosstalk of the system due to the deterioration of cables and environmental factors. This paper discusses the Talk-Back system in a radio communication environment with the application of RF(Radio Frequency) communication system from the wire communication system by cables to ameliorate these problems, and deals with the energy saving environmentally friendly facilities in consideration of replacing power section at salve-equipment with solar batteries benefitting the system in light of energy consumption.

  • PDF

Neuro-fuzzy model of concrete exposed to various regimes combined with De-icing salts

  • Ghazy, Ahmed;Bassuoni, Mohamed. T.
    • Computers and Concrete
    • /
    • v.21 no.6
    • /
    • pp.649-659
    • /
    • 2018
  • Adaptive neuro-fuzzy inference systems (ANFIS) can be efficient in modelling non-linear, complex and ambiguous behavior of cement-based materials undergoing combined damage factors of different forms (physical and chemical). The current work investigates the use of ANFIS to model the behavior (time of failure (TF)) of a wide range of concrete mixtures made with different types of cement (ordinary and portland limestone cement (PLC)) without or with supplementary cementitious materials (SCMs: fly ash and nanosilica) under various exposure regimes with the most widely used chloride-based de-icing salts (individual and combined). The results show that predictions of the ANFIS model were rational and accurate, with marginal errors not exceeding 3%. In addition, sensitivity analyses of physical penetrability (magnitude of intruding chloride) of concrete, amount of aluminate and interground limestone in cement and content of portlandite in the binder showed that the predictive trends of the model had good agreement with experimental results. Thus, this model may be reliably used to project the deterioration of customized concrete mixtures exposed to such aggressive conditions.

Application of High Performance Coatings for Service Life Extension of Steel Bridge Coatings

  • Lee, Chan-Young
    • Corrosion Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.169-174
    • /
    • 2021
  • In this study, performance tests, a field evaluation, and a life cycle cost (LCC) analysis for high performance coating systems were conducted to prepare a plan to reduce the cost of maintenance coating and contribute to the service life extension of steel bridges by applying high performance coatings to steel bridges that will be constructed in the future. From the deterioration models based on the field evaluation for chlorinated rubber and urethane topcoat systems, which have been applied often, the mean service lives were derived as 20.8 and 26.6 years, respectively. For the other coating systems that have not been applied in practice, the coordination factors were differentially applied with evaluation items. The most durable coating system was predicted to be thermal spray coating (TSC) primer/epoxy intermediate coat/fluoride resin topcoat, with a predicted value as long as 42.2 years. The LCC analysis indicates that partial application of high performance coating, such as TSC and fluoride resin, to specific parts vulnerable to corrosion and ultraviolet ray (UV) is more advantageous than the use of general coating systems.

Sulfuric Acid Resistance Evaluation of Repair Mortar Substituted Blast Furnace (고로슬래그를 치환한 보수 모르타르의 내 황산성 평가)

  • Kim, Wan-Su;Jang, Jong-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.25-26
    • /
    • 2019
  • The Reinforced concrete structure is deteriorated in durability due to various deterioration factors such as acid, salt, etc., and thus requires repair and reinforcement. In this study, compressive strength and weight change were measured by substituting blast furnace slag with excellent chemical resistance. As a result, the decrease in compressive strength decreased in proportion to the blast furnace slag substitution rate, and in the case of BFS40, the strength increased after sulfuric acid immersion. The weight change also decreased in proportion to the replacement amount.

  • PDF

CHECKLIST FOR ENVIRONMENTAL FRIENDLY CONSTRUCTION MANAGEMENT IN DESIGN PHASE

  • In-Su Jung;Hyun-Su Park;Chan-Sik Lee
    • International conference on construction engineering and project management
    • /
    • 2007.03a
    • /
    • pp.376-385
    • /
    • 2007
  • Construction project is necessary element for human life to upgrade the quality and convenience. However, due to its contradictory nature to the environment preservation, environmental pollution and damage, deterioration of natural scenery, noise/vibration, water quality pollution, etc. caused in the process of construction greatly affect the environment. For the building or construction project, its possible impact on environment during construction work and after completion must be predicted at its design phase, which will result in the completion of the architecture convenient for human being with its environmental pollution reduced to minimum level. In this study, the checklist of environmental factors was suggested, which should be taken into account at its design phase in conducting the construction work. Proposed checklist was linked with the developed web-based system for the convenience of users like designer and construction manager, etc. It is expected that the checklist suggested by this study will help the designer and construction manager to continue the steady development from the environmental viewpoint during the design phase.

  • PDF

A Study on the Development of Crack Diagnosis Robot for Reinforced Concrete Structures Based on Image Processing (이미지 프로세싱 기반 철근콘크리트 구조물의 균열진단 로봇 개발에 관한 연구)

  • Kim, Han-Sol;Jang, Jong-Min;Kim, Yeung-Kwan;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.103-104
    • /
    • 2022
  • Cracks may occur in reinforced concrete (RC) structures due to various physical and chemical factors, and the growth of cracks causes deterioration of the structure's performance. It is important to prevent the expansion of cracks through periodic diagnosis of cracks in structures. In order to enable free crack exploration even in a narrow space, a construction robot using a Mecanum wheel that can move up, down, left and right and rotate in place was designed. High-quality crack images were periodically collected through the camera, and the image fragments stored during the exploration were combined into a single photo after the exploration was completed. The robot detected cracks with a width of 0.2 mm or more on the concrete probe surface with an accuracy of about 90% or more.

  • PDF

Mechanical Properties of Self-Healing Mortar Using Cementitious Material-Based Capsule (시멘트계 재료 기반 캡슐을 사용한 자기치유 모르타르의 역학 특성)

  • Lee, Jae-In;Im, Soo-Bin;Na, Bum-Su;Kim, Chae-Young;Yoon, Joo-Hoo;Choi, Se-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.149-150
    • /
    • 2023
  • Although concrete is a material widely used in the construction industry, it is very vulnerable to cracking and has a disadvantage in that durability deteriorates when cracks occur. When cracks occur, harmful factors are introduced through the micro-cracks of the structure, reducing durability. Therefore, in this study, as part of a study to alleviate the problems of maintenance and durability deterioration due to cracks in concrete structures, the mechanical properties of self-healing mortar according to the size of the capsule made of cement material were reviewed.

  • PDF

OPTIMIZATION OF STOCK MANAGEMENT SYSTEM WITH DEFICIENCIES THROUGH FUZZY RATIONALE WITH SIGNED DISTANCE METHOD IN SEABORN PROGRAMING TOOL

  • K. KALAIARASI;N. SINDHUJA
    • Journal of applied mathematics & informatics
    • /
    • v.42 no.2
    • /
    • pp.379-390
    • /
    • 2024
  • This study proposes a fuzzy inventory model for managing large-scale production, incorporating cost considerations. The model accounts for two types of expenditure scenarios-parametric and exponential. Uncertainty surrounds holding costs, setup costs, and demand rates. The approach considers a supply chain system with a complex manufacturing process, factoring in transportation costs based on the quantity of goods and distance between the supplier and retailer. The initial crisp model is then transformed into a fuzzy simulation, incorporating specific fuzzy variables affecting inventory costs. The proposed method significantly reduces overall inventory costs for the entire supply chain. Retailer demand is linked to inventory levels, and vendor/distributor storage deteriorates over time. The fuzzy condition assumes hexagonal variables for all associated factors. The study employs the signed distance method for defuzzification to determine the optimal order quantity with hexagonal fuzzy numbers. Mathematical examples are provided to illustrate the practicality of the proposed approach.