• Title/Summary/Keyword: Deterioration Factor

Search Result 397, Processing Time 0.026 seconds

A Study on the Environment Planning of Exhibition Space for Conservation of Collection in a Museum (박물관자료의 보존을 위한 전시공간 환경계획에 관한 연구)

  • Jung, Sung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.2
    • /
    • pp.91-101
    • /
    • 2008
  • The purpose of this study is to suggest the design guidelines of exhibition space for conservation of collection in a museum. With the purpose of this study, examined the concept and a condition of conservation which is focused on deterioration in a exhibition space, investigated the actual condition of total 42 facilities and analyzed the specific instance which is excellent by factor of environment plan. Hereupon, the results of this study are as follows. First, exhibition space should be equipped with sufficient 'Filtering Space' before the outdoor and located central territory in a museum facility. Second, exhibition space should be partition off an area into the quality of collection, and then controlled by each of them. Third, in consideration of the annual air fluctuation of our country, the database which is adaptable for setting up the standard of temperature and RH must be prepared. Fourth, it is necessary to establish a 'Reference Exhibition Room' which is formed cellular type and a 'Garnering Exhibition Center'. Fifth, for the prevention of deterioration which is generated in exhibition space, the showcase must be high air-tight. Sixth, it is necessary to reduce a inside space of high air-tight showcase. Seventh, art-sorb is suitable for control the organic matter of collection and a except of fiber optics is not suitable for lighting of showcase. Eighth, wall-type showcase should be have air-chamber which is formed like museum storage and run over 8 hours a day.

An experimental study on the durability evaluation of concrete applied functional nano composite inorganic activated carbon based coatings (기능성 나노복합 무기질 활성탄계 표면 처리제를 적용한 콘크리트의 내구성능 평가에 관한 실험적 연구)

  • Yang, Gi-Young;Jang, Seog-Jae;Baek, Jong-Myeong
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1385-1390
    • /
    • 2006
  • Concrete structure can be deteriorated by ingress of moisture and aggressive agents. To maintain the sound performance of concrete structure during the service life, it needs to protect concrete from ingress of moisture and aggressive agents before arising deterioration of concrete. Protection of concrete is possible by surface treatment. In this study, durability of the functional nano composite inorganic activated carbon based coatings which can provide a barrier against the ingress of moisture or aggressive ions to concrete is discussed. For the durability evaluation of the coatings, fine void structure evaluation test, chloride penetration acceleration test, accelerated carbonation test, freezing and thawing test, and the accelerated test of chemical erosion are conducted. As the result of this study, the functional nano composite inorganic activated carbon based coatings which became one formed complex compound with adsorption and porosity on concrete surface, had an effect on the function of far infrared radiation, antimicrobial action, air cleaning, airing assurance, and the interception of moisture of deterioration factor, chloride ion, carbon dioxide, sulfate, and so on.

  • PDF

A Study on Evaluation of Complex Deterioration evaluation and Prediction of Residual Life through Concrete Core (콘크리트 코어 분석을 통한 복합열화 평가와 잔존수명 예측 연구)

  • Shim, Jaeyoung
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.332-339
    • /
    • 2017
  • In the case of aged structures, the information of the structure is often lost after the completion of construction, and there is a great difficulty in predicting the durability life of the structure due to the lack of information on concrete formulations. In this study, the durability of concrete specimens was evaluated by various field and indoor test methods based on the core specimens collected from the field, and the durability life of the concrete structures was predicted by using the FEM analysis technique.As a result, the neutralization rate coefficient was $5.38E-6(cm^2/day)$ and the rate of progress was low. And the possibility of complex deterioration due to carbonation and salting was found to be very low.

A Study on Impedance Change Trend and Battery Life Analysis through Battery Performance Deterioration Factors

  • Mi-Jin Choi;Young-Jun Kim;Sang-Bum Kim
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.129-134
    • /
    • 2023
  • Although the use of batteries is rapidly increasing worldwide to improve carbon neutrality and energy efficiency, performance degradation due to the increase in the number of uses is inevitable as it is a finite resource that can be applied according to capacity and specifications. Deterioration and failure of batteries are recognized as important problems in various applications using batteries, including electric vehicles. In order to solve these problems, a diagnostic technology capable of accurately predicting battery life and grasping state information is required, but it is difficult in a non-linear form due to internal structure or chemical change. In this paper, the factors that generally cause battery performance change are directly applied to check whether there are external changes and impedance changes in the battery, and to analyze whether they affect battery life. Impedance change trends and result values were confirmed using a universal impedance spectroscopy method and a self-developed internal impedance measurement method. The results did not significantly affect the impedance change trend. It was confirmed that the increase in the number of times of battery use was prominent in the impedance change trend.

Degradation of Ascorbic acid in Limited Dissolved Oxygen Environment (제한된 산소 존재중의 Ascorbin 산의 분해에 대하여)

  • Rhee, Sook-Hee
    • Journal of Nutrition and Health
    • /
    • v.9 no.4
    • /
    • pp.54-58
    • /
    • 1976
  • Deterioration of ascorbic acid content is the important factor in the food quality. The degradation of ascorbic acid undergoes as a first-order of reaction in the presence of excess oxygen content. However, under the limited oxygen content, ascorbic acid decomposes as a psudo-first order of reaction. The ascorbic acid, in this study, under the limited dissolved oxygen content in the presesce of iron(III) and copper(II) decomposed as first-order reaction with a little influence in rate constant and the light was an accelerating factor on the ascorbic acid degradation.

  • PDF

Study on the Accelerated Test Condition of Pneumatic Cylinder (공기압 실린더 가속시험 조건에 대한 연구)

  • Kang, Bo-Sik;Kim, Hyoung-Eui;Gobin, Remi
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1648-1651
    • /
    • 2007
  • The goal of this paper is to introduce two methods to determine a model for the accelerated factor equation for pneumatic cylinder according to the Black equation shape. The loads consist of working pressure and temperature and we adjust these two parameters to reduce the test time but keeping the true behavior of deterioration. The first part will introduce a method using accelerated factor coming from experimental results to determine the coefficient of the Black equation by the method of the least square theory. The second part will introduce another method based on various conditions of test with the assumption that the effect of temperature and the effect of pressure on the life of pneumatic cylinder are independent. In these two cases, the results are the unknown coefficients of the Black equation.

  • PDF

Analysis of Insulation Characteristics for Stator Winding after Insulation Reinforcement (수력발전기 고정자권선의 절연보강 후 절연특성 분석)

  • Oh, Bong-Keun;Choi, Kyo-Nam;Choi, Hyung-Cheol;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.71-73
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish Painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF

Effect of Stiffness and Strength Degrading Model on Evaluating the Response Modification Factor (강성 및 강도저하 모델이 반응수정계수 산정에 미치는 영향 평가)

  • 오영훈;한상환;이리형
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.25-32
    • /
    • 1998
  • Most recent seismic design codes include Response Modification Factor(RMF) for determining equivalent lateral forces. The RMF is used to reduce the linear elastic design spectrum to account for the energy dissipation capacity, overstrength and damping of the structure. In this study the RMF is defined as the ratio of the absolute maximum linear elastic base shear to the absolute maximum nonlinear base shear of a structure subject to the same earthquake accelerogram. This study investigates the effect of hysteretic model, as well as target ductility ratio and natural period on duct based RMF using nonlinear dynamic analyses of the SDOF systems. Special emphasis is given to the effects of the hysteretic characteristics such as strength deterioration and stiffness degradation. Results indicate that RMFs are dependent on ductility, period and hysteretic model.

  • PDF

A study on the development of diagnosis device for pole transformer deterior (주상변압기 열화진단장치 개발에 관한 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Kim, Young-Chun;Kim, Hun;Min, Kyung-Rae;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1079-1081
    • /
    • 1998
  • This paper describes the dissipation factor measuring device for insulating oil in operating pole transformer by DSP(digital signal processor). After applying voltage to the sensor which is installed in a transformer, acquire source voltage and current of sensor using FFT techniques, then we could evaluate the dissipation factor of insulating oil. To improve measuring accuracy and processing speed, we use TMS320C31 DSP, FFT and data analysis techniques. Also we suggest deterioration criterion of insulating oil and compared the developed diagnosis device with schering bridge on deteriorated insulating oil. The result of this paper show that the developed measuring device can be used as diagnosis device for the pole transformers.

  • PDF

The best accelerated method and lifetime prediction of electrolytic capacitors (전해 캐패시터의 최적 가속시험방법과 수명예측)

  • Kim, Ha-Na;Sim, Chan-Ho;Kim, Sung-Jun;Yoon, Jung-Rag;Lee, Hun-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1945-1947
    • /
    • 2005
  • This study considers find out best accelerated life testing and lifetime prediction of electrolytic capacitors. We proved about relation between failure and deterioration mechanism from last thesis. Beside we performed test that temperature and voltage press higher than allowance specification. Failure distribution acquired from those test. And wiebull function and Minitab program applied to accelerated constant and lifetime by means of calculation. At the result, goodness of fit affect to weibull function and acceleration factor therefore fitting is important factor in reliability testing.

  • PDF