• 제목/요약/키워드: Deterioration Diagnosis

검색결과 345건 처리시간 0.043초

Application of a Silicone Sheet in Negative-Pressure Wound Therapy to Treat an Abdominal Wall Defect after Necrotizing Fasciitis

  • Shin, Jin Su;Choi, Hwan Jun
    • Archives of Plastic Surgery
    • /
    • 제44권1호
    • /
    • pp.76-79
    • /
    • 2017
  • Necrotizing fasciitis (NF) is an aggressive soft-tissue infection involving the deep fascia and is characterized by extensive deterioration of the surrounding tissue. Immediate diagnosis and intensive treatment, including debridement and systemic antibiotics, represent the most important factors influencing the survival of NF patients. In this report, we present a case of NF in the abdomen due to an infection caused by a perforated small bowel after abdominal liposuction. It was successfully treated using negative-pressure wound therapy, in which a silicone sheet functioned as a barrier between the sponge and internal organs to protect the small bowel.

오염된 QMS의 원인 분석과 세정 및 기능 복원 (Analysis of contaminated QMS, cleaning and restoration of functions)

  • 김동훈;주정훈
    • 한국표면공학회지
    • /
    • 제48권4호
    • /
    • pp.179-184
    • /
    • 2015
  • Quadrupole Mass Spectrometers (QMS) is a very useful tool in vacuum process diagnosis. Tungsten filament based ion sources are vulnerable to contamination from process gas monitoring. Common symptoms of quadrupole mass spectrometer malfunction is appearance of unwanted contaminant mass peaks or no detection of any ion peaks. We disassembled used quadrupole mass spectrometer and found out black insulating deposits on inside of ion source parts. Five steps of cleaning procedure were applied and almost full restoration of functions were confirmed in two types of closed ion source quadrupole mass spectrometer. By using a numerical modeling (CFD-ACE+) technique, the electric potential profile of ion source with/without insulating deposit was calculated and showed the possibility of quadrupole mass spectrometer malfunction by the deterioration of designed potential profile inside the ion source.

Intracranial Dissemination from Spinal Cord Anaplastic Astrocytoma

  • Jeong, Seong-Man;Chung, Yong-Gu;Lee, Jang-Bo;Shin, Il-Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권1호
    • /
    • pp.68-70
    • /
    • 2010
  • We report a case of intracranial dissemination developing approximately 4 months after partial removal of a spinal cord anplastic astrocytoma in a 22-year-old male. He presented with paraplegia on initial admission at a local hospital. Spinal magnetic resonance (MR) images disclosed multiple intramedullary lesions at the T3-11. The tumor was partially removed. The final histologic diagnosis was anaplastic astrocytoma. Four months after the operation, he was admitted with the symptoms of headache and deterioration of consciousness. MR images showed enhanced lesions in the anterior horn of the left lateral ventricle, and septum pellucidum. He underwent computed tomography-guided stereotactic biopsy and histological appearance was consistent with anaplastic astrocytoma. The clinical course indicates that the tumor originated in the spinal cord and extended into the subarachnoid space, first the spinal canal and later intracranial.

RF 감지 방식 on-line 케이블 접속재 진단 (On-line Test Equipment for Cable Joint by RF Sensing)

  • 이왕하;이성희;정희돈;김덕규;이동영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권11호
    • /
    • pp.661-667
    • /
    • 2003
  • It has little possibility that a cable causes any problem in electric power facilities. But when a trouble occurs in cable or cable joint, the damage is very severe. The main causes of the cable defections are bad cable making procedure, poor cable operation and deterioration according to the years. There are some cases to have potential problems due to many cable connection points, because of short length of cable, especially in 154㎸ system. In this study, novel method to measure partial discharge in cable joints is proposed and the effectiveness and the reliability of the proposed method is shown through experiment results of field.

고초파 장해기기의 저감 대책의 변화에 관한 연구 (A Study on Variation of Counterplan in Harmonics Interference Equipment)

  • 성은하;오무송;이은학;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.414-417
    • /
    • 1999
  • According to development of power electric technology from industrial field to electronic home appliances, recent SMPS using semiconductor is spread widely. Electric converting instrument uses a sine wave voltage source, namely an usual power source, and it gets a non-sines power source from power source because current flows through one part in waveform of one cycle. This injects higher harmonic source in source part, absorb pollution source. And this cause quality deterioration, durability shortage of electric power instrument, spreading accident of electric solver system, and so on. It can't supply an electric source of good quality in industry, so become an impedimental element in improving productivity and reliance. This study can be used in prediction of hindrance and diagnosis material and intends to suggest a countermeasure about measurement data.

  • PDF

배전용 피뢰기의 인공오손에 의한 누설전류의 고조파 분석 (Harmonics Analysis of Leakage Current due to Artificial Contamination of Distribution Arresters)

  • 박재준
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1306-1313
    • /
    • 2012
  • This paper reports the contamination performance of two distribution arresters (new and used ones) tested under three different contaminant conditions - clean fog, ESDD (equivalent salt deposit density) level (A, B, C, and D), and kaolin contamination conditions, and their leakage current, total leakage current, and component of the resistive leakage current were measured in order to diagnose arrester deterioration. The 3rd harmonics was larger than 5th and 7th ones for the arrester under the clean fog, and as the ESDD contamination level was applied, 5th one became relatively larger than 3rd one. Therefore, these results indicated that the resistive leakage current could be used for the diagnosis of the arresters.

수력발전기의 절연보강 전${\cdot}$후 절연상태 비교평가 (Assessment of Insulation Condition between Diagnosis and Impregnation for Hydro-Generator)

  • 변일환;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1124-1126
    • /
    • 2004
  • The measurements were performed to assess the insulation deterioration condition of the stator winding of Dae-Cheong hydro-generator ${\sharp}2$ which had been in service after being constructed 1980. After repair of the stator winding insulation. we conducted insulation diagnostic tests which include resistance, polarization index(P. I). AC current, dissipation factor($Tan{\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to the previous records. On the basis of these test results. this paper tried to present the importance of insulation repair for the generator stator winding.

  • PDF

대용량 수차발전기의 절연진단과 절연보수 상관관계 평가 (Assessment of Insulation Condition between Diagnosis and Impregnation for Hydro-Generator)

  • 오봉근;정진달;이광호;김현일;곽희진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.39-41
    • /
    • 2004
  • The measurements were performed to assess the insulation deterioration condition of the stator winding of Dae-Cheong hydro-generator #2 which had been in service after being constructed 1980. After repair of the stator winding insulation, we conducted insulation diagnostic tests which include resistance, polarization index(P.I), AC current, dissipation factor($Tan\delta$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to the previous records. On the basis of these test results, this paper tried to present the importance of insulation repair for the generator stator winding.

  • PDF

Development of a Diagnostic Technique of the Historic Structures Using a Thermal Infrared Camera

  • Nakabeppu, Jiro;Maeda, Atsushi;Gotoh, Keinosuke
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.493-495
    • /
    • 2003
  • The establishment of the investigation and the maintenance technique is required for preservation of old structures in Japan. This study attempts to diagnose the deterioration status of the historic structures using the thermal infrared camera. In some structures, the difference of the spatio-temporal change was observed in the surface temperature. For example, the cold joint of concrete was examined using this method effectively. As a result of this study, we have found useful guidelines in developing methodology to conduct diagnosis of historic buildings by using thermal infrared camera.

  • PDF

전력케이블용 절연재료의 열화특성 및 수명진단에 관한 연구 (A Study on the Aging Characteristics and Life Diagnosis of Insulating Materials for Power Cable)

  • 박홍태;김경석;남창우;이규철
    • 한국전기전자재료학회논문지
    • /
    • 제12권1호
    • /
    • pp.11-17
    • /
    • 1999
  • Aging characteristics of the crosslinked polyethylene have been measured after applying electrical, thermal and combined stresses. ICP and FT-IR measurements confirmed diffusion of low molecular weight components such as antioxidant and presence of carbonyl group. Carbonyl group of aged crosslinked polyethylene under combined stress was detected by FT-IR. As deterioration of the crosslinked polyethylene progresses, crystallinity degree and density decrease. Also, dielectric properties have been measured by tan $\delta$ and $\varepsilon$$_{r}$ measurements. The three-parameter Weibull distribution was found to be the best suited among other probabilistic distribution representing the dielectric breakdown strength of aged crosslinked polyethylene. The scale parameter and location parameter decreases as the applied stress increases. The shape parameter increases as the stress increases.s.

  • PDF