• Title/Summary/Keyword: Deterioration Diagnosis

Search Result 345, Processing Time 0.023 seconds

Retethering : A Neurosurgical Viewpoint

  • Lee, Ji Yeoun;Kim, Kyung Hyun;Park, Kwanjin;Wang, Kyu-Chang
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.3
    • /
    • pp.346-357
    • /
    • 2020
  • During the follow-up period after surgery for spinal dysraphism, a certain portion of patients show neurological deterioration and its secondary phenomena, such as motor, sensory or sphincter changes, foot and spinal deformities, pain, and spasticity. These clinical manifestations are caused by tethering effects on the neural structures at the site of previous operation. The widespread recognition of retethering drew the attention of medical professionals of various specialties because of its incidence, which is not low when surveillance is adequate, and its progressive nature. This article reviews the literature on the incidence and timing of deterioration, predisposing factors for retethering, clinical manifestations, diagnosis, surgical treatment and its complications, clinical outcomes, prognostic factors after retethering surgery and preventive measures of retethering. Current practice and opinions of Seoul National University Children's Hospital team were added in some parts. The literature shows a wide range of data regarding the incidence, rate and degree of surgical complications and long-term outcomes. The method of prevention is still one of the main topics of this entity. Although alternatives such as spinal column shortening were introduced, re-untethering by conventional surgical methods remains the current main management tool. Re-untethering surgery is a much more difficult task than primary untethering surgery. Updated publications include strong skepticism on re-untethering surgery in a certain group of patients, though it is from a minority of research groups. For all of the abovementioned reasons, new information and ideas on the early diagnosis, treatment and prevention of retethering are critically necessary in this era.

A Study on Defect Diagnostics of Gas-Turbine Engine on Off-Design Condition Using Genetic Algorithms (유전 알고리즘을 이용한 탈 설계 영역에서의 항공기용 가스터빈 엔진 결함 진단)

  • Yong, Min-Chul;Seo, Dong-Hyuck;Choi, Don-Whan;Roh, Tae-Seong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.350-353
    • /
    • 2007
  • In this study, the genetic algorithm has been used for the real-time defect diagnosis on the operation of the aircraft gas-turbine engine. The component elements of the gas-turbine engine for consideriation of the performance deterioration is consist of the compressor, the gas generation turbine and the power turbine, repectively. Compared to the on-design point on the sea-level condition, the learning data has been increased 200 times in case of the off-design conditions for the altitude, the flight mach number and the fuel consumption. Therefore, enormous learning time has been required for the satisfied convergence. The optimum division has been proposed to decrease learning time as well as to obtain high accuracy. As results, the RMS errors of the defect diagnosis using the genetic algorithm have been estimated under 5 %.

  • PDF

A Study on the Durability Evaluation Criteria for the Vertical Extension Remodeling of Apartment (수직 중축형 리모델링 안전진단 내구성 평가기준 합리화에 관한 연구)

  • Yoon, Sang-Chun;Shin, Dong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.197-205
    • /
    • 2020
  • In 2014, The Housing Act amended to allows vertical extension and increases the units of housing (or total floor area) to site. Currently, the feasibility of performing vertical extension is evaluated based on safety diagnosis provisions and manuals with 1st investigation stage on slope, uneven settlement, load-bearing capacity, and durability. However, a need for more reasonable evaluation criteria for the investigation is still required because there had not been any other case study on the diagnosis for the vertical extension, and the engineering basis on evaluation criteria were not suggested. Accordingly, this study is intended to suggest feasible evaluation criteria on the carbonation, chloride ion contents, corrosion of reinforcements, crack and surface deterioration of concrete for durability assessment by codes and standards of domestic and foreign countries. The results of this study are expected to be beneficial for establishing more reasonable durability evaluation criteria, and in turn, more reliable assessment protocol for vertical extension.

A Study of the Diagnosis of Downtown Deterioration in Busan (부산시 도심 노후화 진단에 관한 연구)

  • Kwon, Il-Hwa;Nam, Kwang-Woo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.16 no.4
    • /
    • pp.39-53
    • /
    • 2013
  • Although the efficient formation of urban space structure is a key factor in energy saving and environmentally-friendly aspect, the maintenance of the center and sub-center of the city that are key factors has been becoming increasingly difficult due to the variability and complexity of urban activities. In the case of Busan, amid the expansion of urban scale due to rapid economic development and overpopulation, systematic approaches to professional diagnosis and maintenance have been significantly insufficient - other than the city basic plan which has been conducted at an interval of 20 years. For the effective management of urban central area, systematic monitoring of the CBD through demand forecast and blight forecast at a city level must first be implemented. In order to fulfill this goal, this study is to figure out the current state of the CBD through the diagnosis on blight of the urban central area in the viewpoint of rehabilitation of the CBD and to propose the measures for practical utilization of the information about space for the further management of the central area of the city. For analysis, the study looks into the present state in terms of physical index, economic index, and social index. And then as a micro-approach by utilizing economic index, the study has thoroughly examined the economic blight of the Seomyun urban central area of Busan. The outcome of the analysis shows that in terms of population distribution and land utilization the area is in the stage of inefficient dispersion after having gone through the stage of suburbanization. It is expected that this study, as the material that proves the necessity of enhancing the function of the CBD, can propose the direction for the management of the urban center of Busan through blight prediction and management of the urban center and can provide the basic data for the long-term urban development that aims at the efficient strengthening of functions of the CBD.

One Case on Diagnosis and Treatment Based on an Overall Analysis of Signs and Symtoms of Stomach Cancer Stage IV (4기 위암환자의 증치에 관한 보고 1례)

  • Ha, Jang;Baek, Tae-Hyeon;Kong, Kyung-Hwan
    • The Journal of Internal Korean Medicine
    • /
    • v.21 no.5
    • /
    • pp.897-902
    • /
    • 2000
  • Objective : The study was to investigate Diagnosis and Treatment Based on an Overall Analysis of Signs and Symtoms(證治) of a patient on stomach cancer stage IV by means of the clinical symptoms. Methods : The observation of the clinical progress was carried out by conducting Diagnosis and Treatment Based on an Overall Analysis of Signs and Symtoms(證治) with the patient diagnosed stomach cancer stage IV. Results : Treatments such as the invigoration of qi(補氣), the flow of qi(行氣), and the relieving pain(止痛) was given because the patient showed the qi deficiency of the spleen and stomach(脾胃氣虛). There were moderate effects for anorexia, indigestion, nausea, and general weakness, but there was not any clear effect for alleviation of abdominal pain except the first period. Specially, compared with two hospitalization treatments in 1998, the third hospitalization treatment did not show any apparent improvement. It was believed that this caused by the patients bodily weakness because of deterioration of anemia from bleeding in the progress of cancer. Conclusion : Diagnosis and treatment based on an overall analysis of signs and symtoms(證治) of a patient on stomach cancer stage IV had moderate effects on the improvement of the patients condition, but in this case we had difficulty in long-term observation because of short hospitalizations or insufficient examination by an oriental-western combined medicine group.

  • PDF

A Study on the Development of PD Simulation Pulse Generator for Evaluation of GIS Diagnosis System (GIS 진단시스템의 평가를 위한 PD 모의 펄스발생기 개발에 관한 연구)

  • Kim, Sungju;Chang, Sughun;Cho, Kook-hee
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.21-27
    • /
    • 2018
  • The expansion and stable operation of electric power facilities are important factors with development of industrial facilities in modern society. In high-voltage equipment such as GIS, the insulation characteristics may be deterioated by environment-friendly gas adaption and miniaturization. There is also the possibility of accidents due to insulation breakdown due to the deterioration of power facilities. Therefore, it is necessary to extend the diagnosis system to continuously monitor the danger signals of these power equipment and to prevent accidents. Most of the internal defects in the GIS system are conductive particles, floating electrode defects, protrusion defects, and the like. In this case, a partial discharge phenomenon is accompanied. These partial discharge signals occur irregularly and various noise signals are included in the field, so it is difficult to evaluate the reliability in the development of the diagnostic system. In this paper, a study was made on equipment capable of generating a partial discharge simulated signal that can be adjusted in size and frequency to be applied to a diagnostic device by electromagnetic wave detection method. The PD simulated pulse generator consists of a user interface module, a high-voltage charging module, a pulse forming circuit, a voltage sensor and an embedded controller. In order to simulate the partial discharge phenomenon similar to the actual GIS, a discharge cell was designed and fabricated. The application of the prototype pulse generator to the commercialized PD diagnosis module confirmed that it can be used to evaluate the performance of the diagnostic device. It can be used for the development of GIS diagnosis system and performance verification for reliability evaluation.

The Development of Integrated Power Quality Diagnosis System for Power System (전력계통 전력품질 통합진단시스템 개발)

  • Kwak, N.H.;Jeon, Y.S.;Park, S.H.;Lee, I.M.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

Study of Performance Diagnostics of Turbo-Shaft Engine for SUAV Using Thermodynamic Sensitivity (열역학적 민감도를 이용한 스마트 무인기용 터보축 엔진의 성능진단 연구)

  • Lee Daewon;Roh Taeseong;Choi Dongwhan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.252-255
    • /
    • 2005
  • The operation of a gas-turbine engine gradually deteriorates the performance of its main components and often generates the defects of its components. The GPA method has been usually used for the diagnosis of the deterioration. In this study, the diagnostic code of the engine performance using the thermodynamic sensitivity between the sensed parameters and the health parameters has been developed without an application of the commercial program. The single performance deterioration of the turbo-shaft engine for SUAV has been estimated with this code.

  • PDF

Electrical Characteristic Changes of ZnO Varistors by Energy Absorption

  • Kim, Woo-Hyun;Hwang, Seong-Cheol;Wang, Guoming;Kil, Gyung-Suk;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.12
    • /
    • pp.817-821
    • /
    • 2017
  • As a ZnO varistor is subjected to electrical and environmental stresses, it degrades gradually, which may result in power interruption by short circuit. This study investigates changes in the electrical characteristics of ZnO varistors due to deterioration owing to energy absorption, and determines the optimal parameters for on-line diagnosis of the varistor. Two types of varistors were used for an accelerated aging experiment involving the application of the $8/20{\mu}s$ standard lightning impulse current. The electrical characteristics in terms of the reference voltage, total leakage current, resistive leakage current, and third-harmonic component of the total leakage current were measured, and their change rates were analyzed. The results revealed that the total leakage current increased slightly with an increase in the varistor absorbed energy, while the resistive leakage current and the third-harmonic component increased apparently. Therefore, the third-harmonic component of the total leakage current was proposed as the optimal parameter for on-line monitoring of ZnO varistor conditions.

Load current and Temperature measurement system for Measuring the Degradation of Power cable (전력케이블의 열화측정을 위한 부하전류 및 온도측정 시스템)

  • Park, Yong-Kyu;Cho, Young-Seek;Lee, Kwan-Woo;Um, Kee-Hong;Park, Dae-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.69-74
    • /
    • 2015
  • Recently, there has been a surge in interest in equipment diagnosis and monitoring technology from the perspective of providing quality electricity in terms of reliability and safety. In order to meet the electrical demands of consumers, reliability of power supply needs to be maintained. For this purpose, a monitoring system for power cable is very important. Since real-time measuring equipment has many advantages, it is highly applicable. By measuring the load current and the surface temperature of power cables, we have monitored and identified the deterioration phenomena of power cables in operation. Since direct measurement of the cable conductor temperature is not easy, we have measured the surface temperature instead, and converted that temperature to obtain the conductor temperature of the cables. In addition, we have designed a system to detect the deterioration processes of the power cables in operation.