Study on Performance and An Exhaust Emission by Bio-Diesel Deterioration and Engine Load Rate at Heavy-Duty Diesel Engine (대형디젤기관에서 바이오디젤 열화와 엔진부하에 따른 배출가스특성 및 성능에 관한 연구)

  • Park, Man-Jae;Kim, Mi-Soo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.3
    • /
    • pp.56-63
    • /
    • 2007
  • Modern diesel vehicle has to comply with the EURO IV, V regulation with low level of particulate matter and smoke emission Moreover, emission standards of each countries are becoming stringent in advanced countries such as USA and Europe. Because Bio-diesel is similar to diesel fuel, it is essential to judge the environmental and health effects deriving from the use of Bio-diesel in diesel engine. The deterioration characteristics of emission in accordance with aging vehicles must be regulated for Bio-diesel. Therefore, under 1200 driving hours, 220,000km driving distance condition and full load, the deterioration characteristics of emission were estimated. We could reduce sulfur contents of fuel, particulate matter and smoke emission by using Bio-diesel and conform the influence of engine performance, emission, and fuel consumption by Bio-diesel deterioration

Analysis of Electrical Characteristics Due to Deterioration of Electromagnetic Contactor (전자접촉기 열화에 따른 전기적 특성 분석)

  • Choi, Sun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.5
    • /
    • pp.407-412
    • /
    • 2019
  • In this paper, the changes in the electrical characteristics (arc energy, contact resistance, and bouncing phenomenon) due to the deterioration of the contact are analyzed. The results are generally consistent and can be analyzed for contact deterioration. The results of the experiment demonstrate that the arc energy is linearly related to the current when the contact samples and the voltage conditions are the same. The contact resistance varies due to multiple factors, but is generally within a certain range, and the contact deterioration can be determined. Contact stabilization can be detected by the decrease in the bouncing phenomenon due to deterioration (the change of the shape of the contact).

A Study on the Evaluation of Stability due to Ground Deterioration of Slope (사면의 지반 열화로 인한 안정성 평가에 관한 연구)

  • Han, Young-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.12
    • /
    • pp.83-92
    • /
    • 2018
  • The lapse of time may cause in the slope structure various deterioration phenomenon progresses in the ground of slope, and collapse due to deterioration of strength, resulting in a decrease in the service life. The approach to slope stability due to the ground deterioration is a different concept from the existing limit equilibrium analysis, which is limited to the physical characteristics and geometrical structure of ground. In this study, we conducted a comparative analysis of various literature studies related to the slope failure characteristics and behaviors to presented the optimal formulas for shear strength reduction, such as the exponential function, the logarithmic function and the inverse hyperbolic function. And then a case study was performed on cut slope of Gyeongbu High Speed Rail construction site along the Yangsan fault zone, where the slope failure of shale layer vulnerable to deterioration occurred. As a result, it was confirmed that landslide occurred due to reduction of shear strength by deterioration, as safety factor is approx. 1.0 at the time when the slope failure occurred. Based on the comprehensive case study, as a quantitative approach to the evaluation of slope stability due to deterioration of ground, finally we propose a method for evaluating slope stability with optimal strength reduction curves.

Relative Effects of Health and Family Factors on Geriatric Depression (노인 우울에 영향을 미치는 요인: 건강요인과 가족요인의 상대적 영향력을 중심으로)

  • Lee, Mee-Ae
    • The Korean Journal of Community Living Science
    • /
    • v.22 no.4
    • /
    • pp.623-635
    • /
    • 2011
  • Over the past few decades, the proportion of elderly people with depression in Korea has been rapidly increasing. The purpose of this study is to explore relative effects of health and family factors on geriatric depression. The data sources are from Korean Longitudinal Study of Aging(2008). The Analysis sample consists of 4,040 cases. Analysis results show that there is a significant variability in geriatric depression according to sociodemographic characteristics, health characteristics, and family characteristics. Hierarchical logistic regression analyses are employed to assess the causal relationship between health characteristics and geriatric depression. Model II showed that ADL(exp(B)=1.732), having difficulties due to sight deterioration(exp(B)=1.398), having difficulties due to masticatory force deterioration(exp(B)=1.414), having difficulties due to pain(exp(B)=2.435), and subjective health status(exp(B)=2.010) are reported as predictors of geriatric depression. Namely, the probability of having geriatric depression of the above predictors has been 1.7 times, 1.4 times, 1.4 times, 2.4 times. 2.0 times higher than normal figures. Among health characteristics, pain is the most prevalent factor. Model III showed that as for family characteristics, coresiding with children(exp(B)=1.312) and frequency of contacting with children by phones, letters, or emails(exp(B)=1.477) are reported as predictors of geriatric depression. Key findings are that health factors have larger effects than family factors on geriatric depression.

Manufacture Technology Development of Paper Mending Tape for Conservation of Archive Document (종이 기록물 보수용 안전 테이프 시제품 제조 기술 연구)

  • Shin, Joung-Soon;Yoo, Sun-Kyun
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.29 no.3
    • /
    • pp.41-53
    • /
    • 2011
  • For manufacturing the tape for repairing archival documents, we tested ten carrier candidates for selecting best material. The tensile strength, transmissivity, stability of deterioration, and processability were determined. Physical-chemical characteristics and stability of deterioration was best to the Hanji. Tensile strength and transmissivity was best in tracing paper, but was low in oil paper, white sketch paper, lyon coat paper. Synthetic carrier to tensile strength showed higher than paper carrier and to the transmissivity showed 2-8 times higher than paper carriers. The tracing paper to the transmissivity was 10 times higher than others. To determine characteristic of conservation to the selected carriers, stability of deterioration was examined at conditions of $90^{\circ}C$ for 15 days. Oil paper and white sketch paper turned strongly yellowish. Cellulopane, Felt, and Cpp film showed stable stability of deterioration, but deformation like wrinkles. PET film and Syntheletic film showed excellent conservation characteristics without any change of exterior. Test of adhesive uniform between carriers and adhesive processability was performed. PET film > Syntheletic film > Tracing Paper in order were determined. Ununiformal adhesive characteristics appeared to Hangi. Accordingly, we thought that Hanji as carrier material might be unsuitable because of low adhesive processability.

Analysis of Deterioration Characteristics by Filtering Processes at 6.6kV Power Cable Systems in Operation (운전 중인 6.6kV 전력 케이블 시스템의 필터링 과정에 의한 열화 특성 해석)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.205-211
    • /
    • 2014
  • With a development of modern industry, demand for electric power is rapidly increasing and the capacity of power transfer is required to become bigger and bigger. At power station, the high-voltage power cable is used as the only method in order to transfer electric power. In this paper, we have analyzed the deterioration characteristics of 6.6kV power cable systems in operation. For the time duration of 2000 days, we have measured the cable in operation in order to extract the data for the deterioration characteristics. By analyzing the data by means of several steps of filtering processes, we could obtain the linear relations of insulation resistances as a function of time. Furthermore, we can verify that the progress characteristics in deterioration process of 6.6kV power cable systems follows the process of heat deterioration.

Surface Deterioration Phenomena in Polyethylene under Corona Discharge (Corona 방전에 의한 Polyethylene의 표면열화현상)

  • 성영권;송진수;민남기
    • 전기의세계
    • /
    • v.24 no.5
    • /
    • pp.82-90
    • /
    • 1975
  • This study investigated the deterioration phenomena of the Polyethylene surface contaminated with organic(Saccharose) or inorganic(NaCl) matters through electrical and optical experiments. And also these experimental results relatively well coincided with which was treated by theoretical process. On the electrical experiment, relation between electric field intensity in corona discharge and time reached to the breakdown, and relation between total amount of charges discharged and increment of applied voltage were investigated. On the optical experiment, discharge time dependence of surface deterioration rate and process of surface deterioration in the X-ray diffraction pattern were investigated. It was concluded that chemical effects by the corona discharge deteriorated insulation characteristics of Polyethylene surface.

  • PDF

Mechanical deterioration and thermal deformations of high-temperature-treated coal with evaluations by EMR

  • Biao Kong;Sixiang Zhu;Wenrui Zhang;Xiaolei Sun;Wei Lu;Yankun Ma
    • Geomechanics and Engineering
    • /
    • v.32 no.2
    • /
    • pp.233-244
    • /
    • 2023
  • With the increasing amount of resources required by the society development, mining operations go deeper, which raises the requirements of studying the effects of temperature on the physical and mechanical properties of coal and adjacent rock. For now, these effects are yet to be fully revealed. In this paper, a mechanical-electromagnetic radiation (EMR) test system was established to understand the mechanical deterioration characteristics of coal by the effect of thermal treatment and its deformation and fracture characteristics under thermo-mechanical coupling conditions. The mechanical properties of high-temperature-treated coal were analyzed and recorded, based on which, reasons of coal mechanical deterioration as well as the damage parameters were obtained. Changes of the EMR time series under unconstrained conditions were further analyzed before characteristics of EMR signals under different damage conditions were obtained. The evolution process of thermal damage and deformation of coal was then analyzed through the frequency spectrum of EMR. In the end, based on the time-frequency variation characteristics of EMR, a method of determining combustion zones within the underground gasification area and combustion zones' stability level was proposed.

Analysis of Physical Characteristics and Deterioration Type of Trail in National Parks (국립공원 탐방로의 물리적 특성 및 훼손유형 분석 - 6개 국립공원을 대상으로 -)

  • Jeong, Won-Ok;Ma, Ho-Seop;Kang, Won-Seok
    • Journal of agriculture & life science
    • /
    • v.46 no.1
    • /
    • pp.17-27
    • /
    • 2012
  • The purpose of this study is to analyze the trail deterioration condition and to obtain the information for the desirable maintenance and restoration of trail in national parks. The results obtained from this study were summarized as follows; The physical characteristics of trail were surveyed at the total 778 point for 204.5 km in length. As a result, the average degree of trail was $14.6^{\circ}$, average trail width was 1.5m and average bared trail width was 1.1 m. Major deterioration types of trail were trail deepen (37%), root exposed, widen, diverged, rock exposed and slope erosion in order of frequency. Deterioration class of trail were that non-deterioration was 165.34 km (80.9%), heavy class was 9.08 km, middle class was 12.69 km and light class was 17.39 km and the deterioration rate was 19.1%.