• Title/Summary/Keyword: Deterioration Characteristics

Search Result 995, Processing Time 0.035 seconds

Diffusion Characteristics of Chloride ion under Single and Combined Attacks in Concrete Structures (콘크리트 구조물의 단일 및 복합열화 환경하에서의 염소이온 확산특성)

  • 오병환;강의영;인광진;이성규;서정문
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.708-717
    • /
    • 2002
  • Durability is a major concern in the design and construction of concrete structures which are located in the sea environments. In particular, the combined action of chlorides, sulfates, and carbonation nay influence greatly the deterioration behavior of concrete structures. The purpose of the present study is to explore the diffusion characteristics of chloride ions in concrete structures under combined deterioration conditions. The present test results indicate that the chloride penetration into concrete structures is more pronounced under combined attacks of chlorides, sulfates and carbonation. The diffusion coefficients and surface chloride contents were found to increase under combined multiple deterioration conditions. The present study provides quantitatively the penetration and diffusion characteristics of chloride ions in concrete structures under various deterioration conditions. The results of present study may be efficiently used for the realistic design of concrete structures under combined deterioration conditions.

Surface and Component Analysis of Deteriorated ACSR due to a Flame (화염에 열화된 강심알루미늄연선의 표면 및 성분분석)

  • Kim, Young-Dal;Shim, Jae-Myung;Park, Keun-Seok;Jeong, Yun-Mi;Kim, Jae-Kwang;Byun, Jeong-Seop;Lee, Dae-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1966-1971
    • /
    • 2011
  • Generally, the characteristics of the conductor that was affected by forest fire can be analyzed only when the forest fire is accurately modeled and its effect is identified. Few studies have been conducted with a forest fire model for transmission lines, and no results of the examination of the actual test specimens that were exposed to forest fire have been reported. As the deterioration characteristics of a forest fire are difficult to analyze in the actual field, an environment that was similar to that in the field was used in this study. Deterioration was deposited on a wire using an artificial flame experiment device, to analysis the temperature, surface and component characteristics. It seems that this analysis data in this study can be used as the basic data for the database that can be utilized to analyze wires exposed to forest fire and deterioration and to predict the ACSR wire refurnishment life.

Characterization of culturable yeast species associating with whole crop corn and total mixed ration silage

  • Wang, Huili;Hao, Wei;Ning, Tingting;Zheng, Mingli;Xu, Chuncheng
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.2
    • /
    • pp.198-207
    • /
    • 2018
  • Objective: This study investigated the association of yeast species with improved aerobic stability of total mixed ration (TMR) silages with prolonged ensiling, and clarified the characteristics of yeast species and their role during aerobic deterioration. Methods: Whole crop corn (WCC) silages and TMR silages formulated with WCC were ensiled for 7, 14, 28, and 56 d and used for an aerobic stability test. Predominant yeast species were isolated from different periods and identified by sequencing analyses of the 26S rRNA gene D1/D2 domain. Characteristics (assimilation and tolerance) of the yeast species and their role during aerobic deterioration were investigated. Results: In addition to species of Candida glabrata and Pichia kudriavzevii (P. kudriavzevii) previously isolated in WCC and TMR, Pichia manshurica (P. manshurica), Candida ethanolica (C. ethanolica), and Zygosaccharomyces bailii (Z. bailii) isolated at great frequency during deterioration, were capable of assimilating lactic or acetic acid and tolerant to acetic acid and might function more in deteriorating TMR silages at early fermentation (7 d and 14 d). With ensiling prolonged to 28 d, silages became more (p<0.01) stable when exposed to air, coinciding with the inhibition of yeast to below the detection limit. Species of P. manshurica that were predominant in deteriorating WCC silages were not detectable in TMR silages. In addition, the predominant yeast species of Z. bailii in deteriorating TMR silages at later fermentation (28 d and 56 d) were not observed in both WCC and WCC silages. Conclusion: The inhibition of yeasts, particularly P. kudriavzevii, probably account for the improved aerobic stability of TMR silages at later fermentation. Fewer species seemed to be involved in aerobic deterioration of silages at later fermentation and Z. bailii was most likely to initiate the aerobic deterioration of TMR silages at later fermentation. The use of WCC in TMR might not influence the predominant yeast species during aerobic deterioration of TMR silages.

A Study on Deterioration Measurement Sensor in the Automobile Engine Oil (자동차용 엔진오일의 열화도 측정 센서연구)

  • Kim, Won-Tae;Choi, Man-Yong;Park, Hae-Won;Park, Jung-Hak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.3 s.192
    • /
    • pp.61-66
    • /
    • 2007
  • This work is aimed to measure the deterioration in oil sensor. For the study, the circuit of a coil-type oil sensor packaged was developed and applied to the automobile engine for monitoring the deterioration of engine oil in driving conditions. From the principle which the deterioration of automobile engine oil can be expressed to the dielectric constant, the capacitance bridge circuit and the integrator circuit were designed. As results, the range of operating temperature of engine oil was experimentally recommended within $55^{\circ}C$ for the stability of a sensor designed. It was also concluded that the characteristics of output voltage converted from the dielectric constant were linearly distributed and predicted the optimized time for the exchange of engine oil.

A Study on the Deterioration Patterns of Building Components in the Rental Apartment Housing (임대공동주택 구성재의 열화도 패턴에 관한 연구)

  • Lee Kang-Hee
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.65-72
    • /
    • 2006
  • Most of buildings have been deteriorated with time-elapse by reflection of the building location, material, environmental circumstances and so on. The performance would go down and be demolished if anything could not be done after constructed. The maintenance should be required to preserve a decent living condition or improve a inferior condition by various plans and practices. The maintenance plan needs various data such as a repair scope, a repair time, a forecasted cost, a plan of management and so forth. Among the above required data for planning the maintenance, the deterioration characteristics of the building components would be first analyzed. The deterioration pattern would be a key role to affect and make a maintenance plan. In this paper, it aimed at classifying the deterioration patterns of building components. A deterioration pattern would be analyzed between the cumulative repair cost and time-elapse and modeled with these relations. A deterioration patterns are classified into 4 types-a accelerated type, a straight type, a temporary type and a slowly type. As a result of this research, a accelerated type includes window, window frame, general paintings, general water proofing in building components. A straight type includes the lacquer paintings, furnishings in building components and water supply pipe, boiler, sanitaries in mechanical facilities and lighting in electric facilities. Based on these research results, further study should be conducted to include any other components and an estimating model.

Clarification the Current Situation of Deterioration and Its Causes of Modernization Heritage Built with Bricks in Japan: A Case Study of Long-Term Monitoring Investigation at Sarushima Battery, Yokosuka, Japan

  • Fukami, Risako;Matsui, Toshiya;Kawamoto, Mayumi
    • Journal of Conservation Science
    • /
    • v.38 no.4
    • /
    • pp.265-276
    • /
    • 2022
  • A long-term monitoring investigation at Sarushima Battery (Kanagawa, Japan), which is one of the modernization heritages was conducted from 2017.06 to 2020.12. The investigation of the temperature and relative humidity (RH), measurement of the amount of brick decay, and X-ray diffraction analysis of the brick decay was conducted to understand in detail the environment in which the historical brick structure, the state of deterioration, identify the factors of deterioration. Furthermore, it was discussed whether the suitability of these investigation methods for assessing the status, identifying the level of deterioration and the factors that led to deterioration at the historical brick heritages. It was found that the brick deterioration at the site progressed especially in two periods: in April, and from June to August. These periods coincided with the period when the RH inside the structure decreased, and the Toyo-gumi bricks were in the process of absorbing moisture. Several different types of salts were detected in brick decay, especially thenardite, which is considered highly hazardous and destructive during periods when the amount of brick decay increased. Therefore, the RH in the structure and the salts present in the bricks were identified as one of the factors in the deterioration of the bricks at the site. The methods used in this study are appropriate as the initial survey methods for investigating the current conditions and identifying the causes of deterioration because it is possible to understand the environment within the modernization heritages, grasp the details of deterioration progression, and identify the characteristics of deterioration progression and its factors through long-term investigation using the simple methods.

Breakage Characteristics of Ballast (도상자갈의 마모/파쇄 특성)

  • 정근영;김현기;이종득
    • Journal of the Korean Society for Railway
    • /
    • v.2 no.3
    • /
    • pp.61-69
    • /
    • 1999
  • The durability of ballast plays an important role in track behaviour. To estimate the deterioration characteristics of ballast, several tests have been carried out by several scholars. The deterioration characteristics is very important factor in the behaviour of track and its life. In this paper, abrasion/breakage characteristics of ballast is studied to see the effect of physical ballast characteristics on ballast life. To reveal breakage characteristics of ballast, the ballast box test and the MTT field test were carried out. The breakage characteristics studied in this paper is applied to the ballast life prediction in various conditions, such as LA abrasion, annual tonnage, tamping number per year, etc

  • PDF

The discharge characteristics and ICP-AES analysis of insulators by surface deterioration (애자 표면열화에 의한 방전특성과 ICP-AES 분석)

  • Shong, Kil-Mok;Kim, Young-Seok;Jung, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1408_1409
    • /
    • 2009
  • It's described the discharge characteristics and ICP-AES analysis of insulators by surface deterioration in this paper. For the assessment of insulators, there are applied the conductivity of dusts, contact angle measurement of the insulator surfaces and the ingredient analysis in each area. Through the analysis of pollutants attached to insulators inside the tunnel, the cleaning cycle is discussed. As the results, it would be expected to the electrical safety.

  • PDF

Physical characteristics and evaluation of deteriorations class of a trail in Deogyusan National Park

  • Ju-Ung Yun;Myeong-Jun Kim;Hong-Seok Bang;Jin-Won Kim;Won-Ok Jeong
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.2
    • /
    • pp.367-377
    • /
    • 2022
  • The purpose of this study was to analyze the deterioration of trail conditions and to obtain information for desirable maintenance and restoration of a trail in Deogyusan National Park. The physical characteristics of a trail were surveyed at a total of 412 sites over 79.8 km length. The average trail degree and width were found to be 14.31° and 1.60 m, respectively, while the average bare trail width was 1.40 m and the average maxim trail depth was 5.66 cm. Major deterioration types of trail were trail deepening (36.6%), rock exposure (33.9%), and root exposure (12.5%) in order of frequency. Deterioration classes of the trail were 0.626 km (0.8%), 3.110 km (3.9%) and 8.935 km (11.2%) for heavily, moderately, and lightly deteriorated, respectively, with a deterioration rate of 12.671 km (15.9%). Compared to other national parks, the ratio damaged trail to the total trail was 15.9%, which is slightly higher than other, including Jirisan National Park 9.6% (2019), Bukhansan National Park 13.6% (2019), Sokrisan National Park 11.7% (2019), Chiaksan National Park 12.3% (2015), and Woraksan National Park 10.5% (2015). The section of trail in Deokyusan National Park where the damage grade is analyzed as "Heavy" should therefore be restored in consideration of the field conditions. In particular, the damage status of the trail is expected to be greatly improved when the trail surface maintenance level is restored.

Assessment of Insulation Deterioration in Stator Windings of High Voltage Motor (고압전동기 고정자 권선의 절연열화 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.711-716
    • /
    • 2012
  • To assess the insulation deterioration of stator windings, diagnostic and AC breakdown tests were performed on the eleven high voltage (HV) motors rated at 6kV. After completing the diagnostic tests, the AC overvoltage test was performed by gradually increasing the voltage applied to the stator windings until electrical insulation failure occurred, to obtain the breakdown voltage. Stator winding of motors 1, 3, and 8 failed at above rated voltage at 14 kV, 13.8kV, and 16.4kV, respectively. The breakdown voltage of three motors was higher than expected for good quality windings in 6kV motors. Based on deterioration evaluation criteria, the stator winding insulation of eleven HV motors are confirmed to be in good condition. The turning point of the current, $P_{i2}$, in the AC current vs. voltage characteristics occurred between 5kV and 6kV, and the breakdown voltage was low between 13.8kV and 16.4kV. There was a strong correlation between the breakdown voltage and various electrical characteristics in diagnostic tests including Pi2.