• 제목/요약/키워드: Detector characterization

검색결과 90건 처리시간 0.029초

이산화탄소 감지소자를 위한 마이크로볼로미터 구조 최적화 및 특성연구 (Structure optimization and characterization of a microbolometer for a CO2 detector)

  • 서호원;김태근;문성욱
    • 센서학회지
    • /
    • 제17권1호
    • /
    • pp.75-80
    • /
    • 2008
  • In this work, we optimized a microbolometer for application of a $CO_2$ detector by using MEMS technology. We fabricated a stable thermal isolation structure by varying the lengths of supporting legs which affect bolometer performance. We could fabricate more stable thermal isolation structure for the microbolometer through the results of ANSYS simulations, and minimize the fabrication processes by using bulk micromachining to use a $CO_2$ detector. The microbolometer shows a detectivity of $2.5{\times}109$ cmHz$^{1/2}$/W at a chopper frequency of 8 Hz and a bias current of $6.25\;{\mu}A$ with a vacuum package of about $3.0{\times}10.3$ torr. Therefore, we put to conclusion that the microbolometer optimized in this experiment could be useful for the application of a $CO_2$ detector.

소동물 전용 양전자방출단층시스템의 섬광체 배열에 따른 특성 평가: 몬테칼로 시뮬레이션 연구 (Characterization Study of Detector Module with Crystal Array for Small Animal PET: Monte Carlo Simulation)

  • 백철하
    • 한국콘텐츠학회논문지
    • /
    • 제15권4호
    • /
    • pp.350-356
    • /
    • 2015
  • 본 연구의 목적은 몬테칼로 모사방법을 이용하여 소동물 전용 양전자방출단층촬영 시스템의 모듈 내 섬광체 배열 수에 따른 특성평가를 하는 것이다. 이 연구에서 제안한 소 동물 전용 양전자방출단층촬영 시스템은 모듈 내 섬광체 수를 1 ~ 8개로 구성하였으며, 섬광체 크기는 $2.0{\times}2.0{\times}10.0mm^3$ 크기의 LSO섬광결정을 사용하였고 스캐너의 직경은 100 mm로 설계하였다. 몬테칼로 시뮬레이션 방법중에 하나인GATE 코드를 이용하여 선원은 511 keV 점선원을 이용하였으며 동시계수 측정된 좌표값을 이용하여 민감도 및 사이노그램을 획득하였다. 모듈 내 섬광체 수가 적을수록 모듈 별 틈새가 줄어들어 민감도가 향상되는 결과를 보였으며, 사이노그램 결과에서도 불완전한 데이터(missing data)가 발생하지 않는 것을 알 수 있었다. 이 연구 결과는 모듈 안 섬광체 수가 적을수록 민감도 향상 및 불완전한 데이터 획득이 줄어드는 것을 증명함으로써, 소동물 전용 양전자방출단층촬영 시스템의 성능 개선을 위한 새로운 접근법을 제시한다.

Array Type의 Single Photon Counting Digital X-ray Detector의 제작 및 특성 평가 (Fabrication and Characterization of Array Type of Single Photon Counting Digital X-ray Detector)

  • 서정호;임현우;박진구;허영;전성채;김봉회
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.32-32
    • /
    • 2008
  • X-ray detector는 의료용, 산업용 등 다양한 분야에서 사용되어지고 있으며 기존의 Analog X-ray 방식의 환경오염, 저장공간 부족, 실시간 분석의 어려움 등의 문제점들을 해결하기 위하여 Digital X-ray로의 전환과 연구가 활발하며 이에 따른 관심도 높아지고 있는 살점이다. Digital X-ray detector는 p-영역과 n-영역 사이에 아무런 불순물을 도핑하지 않은 진성반도체(intrinsic semiconductor) 층을 접합시킨 이종접합 PIN 구조의 photodiode 이다. 이 소자는 역바이어스를 가해주면 p영역과 n영역 사이에서 캐리어 (carrier)가 존재하지 않는 공핍 영역이 발생하게 된다. 이런 공핍 영역에서 광흡수가 일어나면, 전자-정공 쌍이 발생한다. 그리고, 발생한 전자-정공 쌍에 전압이 역방향으로 인가되는 경우, 전자는 양의 전극으로 이동하고, 정공은 음의 전극으로 이동한다. 이와 같이, 발생한 캐리어들을 검출하여 전기적인 신호로 변환 시킨다. 고해상도의 Digital X-ray detector를 만들기 위해서는 누설전류에 의한 noise 감소와 소자의 높은 안정성과 내구성을 위한 높은 breakdown voltage를 가져야 한다. 본 연구에서는 Digital X-ray detector의 leakage current 감소와 breakdown voltage를 높이기 위하여 guradring과 gettering technology를 사용하여 전기적 특성을 분석하였다. 기판으로는 $10k\Omega{\cdot}cm$ resistivity를 갖으며, n-type <111>인 1mm 두께의 4인치 Si wafer를 사용하였다. 그리고 pixel pitch는 $100{\mu}m$이며 active area는 $80{\mu}m{\times}80{\mu}m$$32\times32$ array를 형성하여 X-ray를 조사하여 소자의 특성을 평가 하였다.

  • PDF

SEC/Light Scattering Analysis of Multicomponent Polymer Systems

  • 이희정;장태현
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권7호
    • /
    • pp.648-653
    • /
    • 1996
  • We have shown several examples of characterization of multicomponent polymer systems by size exclusion chromatography coupled with a light scattering detector. Although SEC cannot provide a complete information for such systems due to its intrinsic limitation, one can extend its capability by combining multiple detection in order to get relevant information to some extent.

UHF 부분방전 감시 장치를 위한 초광대역 검출장치 개발 및 특성조사 (Development and characterization of a ultra-wide bandwidth video detector for the UHF partial discharge monitoring system)

  • 박기준;구선근;윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1649-1651
    • /
    • 2002
  • Ultra-wide bandwidth (UWB) detection method has been widely used as a front end detection scheme for the ultra-high frequency (UHF) partial discharge (PD) monitoring systems. A broad-band video detector module was developed and characterized for the UHF UWB PD detection systems. The useable bandwidth of the module is more than 2 GHz and it is optimized for 50-ohm systems. The detection sensitivity and dynamic range of the module were characterized by using a known ns-width RF pulses of GHz range. The dynamic range is more than 6-decades and the module can detect pulsed RF signals down to 1 nW. The detector module can eliminate expensive equipment such as high speed oscilloscopes and radio frequency (RF) spectrum analyzers. Therefore, it enables one to use slow speed data acquisition systems for the PD monitoring at the UHF range. The detector module was used to detect real PDs of about <3 pC. The module converts the UWB PD signals into a low-bandwidth video signal with a high signal-to-noise ratio.

  • PDF

Evaluation of the KASI Detector Performance Test System Using an Andor iKon M CCD Camera

  • Yu, Young Sam;Kim, Jinsol;Park, Chan;Jeong, Woong-Seob;Kim, Minjin;Choi, Seonghwan;Park, Sung-Joon
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권3호
    • /
    • pp.201-210
    • /
    • 2018
  • The characterization of detectors installed in space- and ground-based instruments is important to evaluate the system performance. We report the development of a detector performance test system for astronomical applications using the Andor iKon M CCD camera. The performance test system consists of a light source, monochromator, integrating sphere, and power meters. We adopted the Czerny-Tuner monochromator with three ruled gratings and one mirror, which covers a spectral range of 200-9,000 nm with a spectral resolution of ~1 nm in the visible region. Various detector characteristics, such as the quantum efficiency, sensitivity, and noise, can be measured in wide wavelength ranges from the visible to mid-infrared regions. We evaluated the Korea Astronomy and Space Science Institute (KASI) detector performance test system by using the performance verification of the Andor iKon-M CCD camera. The test procedure includes measurements of the conversion gain ($2.86e^-/ADU$), full well capacity ($130K\;e^-$), nonlinearity, and pixel defects. We also estimated the read noise, dark current, and quantum efficiency as a function of the temperature. The lowest measured read noise is $12e^-$. The dark current at 223 K was determined to be $7e^-/s/pix$ and its doubling temperature is $5.3^{\circ}C{\pm}0.2^{\circ}C$ at an activation energy of 0.6 eV. The maximum quantum efficiency at 223 K was estimated to be $93%{\pm}2%$. We proved that the quantum efficiency is sensitive to the operating temperature. It varies up to 5 % in the visible region, while the variation increases to 30 % in the near-infrared region. Based on the comparison of our results with the test report by the vendor, we conclude that our performance test results are consistent with those from the vendor considering the test environment. We also confirmed that the KASI detector performance test system is reliable and our measurement method and analysis are accurate.

Current Progress in Fabrication of Ta and Nb based STJs for an Astronomical Detector

  • Yoon, Ho-Seop;Park, Young-Sik;Park, Jang-Hyun;Yang, Min-Kyu;Lee, Jeon-Kook;Chong, Yon-Uk;Lee, Yong-Ho;Lee, Sang-Kil;Kim, Dong-Lak;Kim, Sug-Whan
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.37.3-37.3
    • /
    • 2008
  • STJ(Superconducting Tunnel Junction) technique offers next generation photon detectors exhibiting high energy resolution, high quantum efficiency and photon counting ability over the broad wavelength range from X-ray to NIR. We report the succcess in fabrication of Ta/Al-AlOx-Al/Ta and Nb/Al-AlOx-Al/Nb micro structure deposited on sapphire substrates using various techniques including UV photolithography, DC Sputtering, RIE, and PECVD technique. The characterization experiment was undertaken in an Adiabatic Demagnetization Refrigerator at an operating temperature below 50mK. The details of experimental investigations for electrical characterization of STJ of $20\sim80{\mu}m$ in side-lengths are discussed. The measured I-V curves were used to derive The detector performance indicators such as energy gap, energy resolution, normal resistance, normal resistivity, dynamic resistance, dynamic resistivity, and quality factor.

  • PDF

Characterization of Triterpenoids, Flavonoids and Phenolic Acids in Eclipta prostrata by High-performance Liquid Chromatography/diode-array Detector/electrospray Ionization with Multi-stage Tandem Mass Spectroscopy

  • Lee, Ki-Yong;Ha, Na-Ry;Kim, Tae-Bum;Kim, Young-Choong;Sung, Sang-Hyun
    • Natural Product Sciences
    • /
    • 제16권3호
    • /
    • pp.164-168
    • /
    • 2010
  • High-performance liquid chromatographic method with diode-array detector and electrospray ionization with multi-stage tandem mass spectroscopy (HPLC/DAD/ESI-$MS^n$) was used to identify the major constituents in a methanolic extract of Eclipta prostrata. The chromatographic separation was performed on a C18 column. Acetonitrile-water was used as a mobile phase. HPLC/DAD/ESI-$MS^n$ allowed the characterization of constituents of E. prostrata, mainly triterpenoids (eclalbasaponin I, II, III, IV, VI), flavonoids (luteolin 7-O-glucoside, demethylwedelolactone, wedelolactone, luteolin, demetylwedelolactone sulfate, luteolin sulfate, apigenin sulfate) and phenolic acids (5-O-caffeoylquinic acid, 3, 4-O-dicaffeoylquinic acid, 3, 5-O-dicaffeoylquinic acid, 4, 5-Odicaffeoylquinic acid).