• 제목/요약/키워드: Detector Pixel

검색결과 215건 처리시간 0.031초

A Study of Edge Detection for Auto Focus of Infrared Camera

  • Park, Hee-Duk
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권1호
    • /
    • pp.25-32
    • /
    • 2018
  • In this paper, we propose an edge detection algorithm for auto focus of infrared camera. We designed and implemented the edge detection of infrared image by using a spatial filter on FPGA. The infrared camera should be designed to minimize the image processing time and usage of hardware resource because these days surveillance systems should have the fast response and be low size, weight and power. we applied the $3{\times}3$ mask filter which has an advantage of minimizing the usage of memory and the propagation delay to process filtering. When we applied Laplacian filter to extract contour data from an image, not only edge components but also noise components of the image were extracted by the filter. These noise components make it difficult to determine the focus state. Also a bad pixel of infrared detector causes a problem in detecting the edge components. So we propose an adaptive edge detection filter that is a method to extract only edge components except noise components of an image by analyzing a variance of pixel data in $3{\times}3$ memory area. And we can detect the bad pixel and replace it with neighboring normal pixel value when we store a pixel in $3{\times}3$ memory area for filtering calculation. The experimental result proves that the proposed method is effective to implement the edge detection for auto focus in infrared camera.

가중치 윤곽선 검출기를 이용한 저 복잡도 하이브리드 보간 알고리듬 (Low Complexity Hybrid Interpolation Algorithm using Weighted Edge Detector)

  • 권혁진;전광길;정제창
    • 한국통신학회논문지
    • /
    • 제32권3C호
    • /
    • pp.241-248
    • /
    • 2007
  • 예측(predictive) 이미지 코딩에서는 최소 자승법을 기반으로 하는 적응적인 예측기가 에지 주변에 있는 픽셀(pixel)의 예측 결과를 향상시키는데 효과적인 방법으로 알려져있다. 본 논문에서는 가중치 윤곽선 검출기 (weighted edge detector)를 이용한 하이브리드 보간 알고리듬(hybrid interpolation algorithm)을 제안한다 전체적인 계산의 복잡도를 감소시키기 위해서 2차원 선형 보긴(bilinear interpolation)과 에지 방향성을 이용한 보간(edge directed interpolation) 알고리듬을 선택적으로 적용시키는 하이브리드 접근방법을 이용한다. 이런 접근 방법을 2차원 선형 보간 알고리듬과 에지 방향성을 이용한 보간 알고리듬을 적용했을 경우와 비교하기 위해서 PSNR과 SSIM 측정값을 이용하여 객관적이고 주관적인 영상의 화질 비교는 제안한 알고리듬이 비슷한 성능을 나타냄을 보여준다. 또한 제안하는 가중치 윤곽선 검출기를 이용한 하이브리드 보간 알고리듬은 정규화된 CPU 수행 시간을 에지 방향성을 이용한 보간 알고리듬과 비교하면 최대 20배의 복잡도 감소 효과를 얻을 수 있다.

잡음영상에서 로버스트 순위-순서 검정을 이용한 효과적인 에지검출 (Efficient Edge Detection in Noisy Images using Robust Rank-Order Test)

  • 임동훈
    • 응용통계연구
    • /
    • 제20권1호
    • /
    • pp.147-157
    • /
    • 2007
  • 에지검출은 컴퓨터비전과 영상처리 시스템에서 널리 사용되는 단계이다. 본 논문에서는 잡음영상에서 효율적인 에지검출을 위해 이표본 위치 문제에서 월콕슨 검정의 대안인 로버스트 순위-순서 검정에 기초한 새로운 검출법을 제안하였다. 제안된 방법은 $\delta$-에지모형하에서 $5\times5$ 윈도우의 부분 픽셀만으로 구성된 근방영역 간에 통계적으로 유의한 차이가 있는지를 조사하였다. 제안된 에지 검출법의 성능을 평가하기 위해 실제영상과 인조영상을 가지고 영상실험을 통하여 얻은 에지맵과 객관적인 척도하에서 양적으로 비교 분석하였다.

Photon-Counting Detector CT: Key Points Radiologists Should Know

  • Andrea Esquivel;Andrea Ferrero;Achille Mileto;Francis Baffour;Kelly Horst;Prabhakar Shantha Rajiah;Akitoshi Inoue;Shuai Leng;Cynthia McCollough;Joel G. Fletcher
    • Korean Journal of Radiology
    • /
    • 제23권9호
    • /
    • pp.854-865
    • /
    • 2022
  • Photon-counting detector (PCD) CT is a new CT technology utilizing a direct conversion X-ray detector, where incident X-ray photon energies are directly recorded as electronical signals. The design of the photon-counting detector itself facilitates improvements in spatial resolution (via smaller detector pixel design) and iodine signal (via count weighting) while still permitting multi-energy imaging. PCD-CT can eliminate electronic noise and reduce artifacts due to the use of energy thresholds. Improved dose efficiency is important for low dose CT and pediatric imaging. The ultra-high spatial resolution of PCD-CT design permits lower dose scanning for all body regions and is particularly helpful in identifying important imaging findings in thoracic and musculoskeletal CT. Improved iodine signal may be helpful for low contrast tasks in abdominal imaging. Virtual monoenergetic images and material classification will assist with numerous diagnostic tasks in abdominal, musculoskeletal, and cardiovascular imaging. Dual-source PCD-CT permits multi-energy CT images of the heart and coronary arteries at high temporal resolution. In this special review article, we review the clinical benefits of this technology across a wide variety of radiological subspecialties.

비정질 셀레늄 기반 디지털 방사선 검출기의 성능 평가 (Performance Evaluation of a Selenium(a-Se) Based Prototype Digital Radiation Detector)

  • 박지군;강상식;조성호;신정욱;김소영;손대응;남상희
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.300-305
    • /
    • 2007
  • In this study, we have studied the fabrication and the performance evaluation of digital radiation detector of the based on selenium (a-Se) prototype which is widely researched about recently. The detector was fabricated using amorphous selenium in the specification of active area size $7{\times}8.5"$, pixel pitch $139{\mu}m$, and 12 bit ADC. In order for the performance evaluation of the fabricated detector, we used radiation quality RQA 5 that is suggested by the International Electrotechnical Commission (IEC), and evaluated modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Concerning MTF measurement, we used slit camera (Nuclear Associates, Model : 07-624-2222), and evaluated in the slit method. Also so as to compare the performance evaluation on the detector fabricated in this study, we used Hologic Direct-Ray (DR-1000) and GE Revolution XQ/I system, and evaluated and compared in the same method MTF, NPS, and DQE which are image quality factors. And as a result, the MTF of each detector In Nyquist frequency were evaluated to be 58% (at 3.5 lp/mm) in the case of DR-1000 and 65% (at 2.5 lp/mm) in the case of XQ/I, and that for the detector fabricated in this study was evaluated to be 36% (at 3.51 lp/mm). Also in the case of DQE(0), the detector fabricated in this study, DR-1000 of Hologic company, and XQ/I system of GE company respectively were evaluated as 36%, 32%, and 50%.

평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구 (Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance)

  • 박지군;최장용;강상식;이동길;석대우;남상희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권4호
    • /
    • pp.39-46
    • /
    • 2003
  • 의료영상 분야에서의 디지털화가 시도되면서부터 평판형 디지털 영상검출기가 일반촬영 및 투시영상을 비롯한 다양한 영상 획득 장치에의 적용을 위해 꾸준히 연구, 개발되어져 왔다. 본 연구는 비정질 셀레늄을 이용한 디지털 방사선 검출기를 통해 획득된 영상의 평가를 통해 순수 국내 기술로 개발중인 디지털 방사선 검출기의 임상 사용여부를 확인하고, 영상평가의 주요인자인 modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) 이용하여 정량적인 값을 도출함으로써 의료영상평가에 필요한 측정 방법 및 그 기초 자료의 제공을 그 목적으로 한다. 비정질 셀레늄을 이용한 디지털 방사선 검출기는 pixel pitch가 $139\;{\mu}m$이며, 전체 active area은 $14{\times}8.5\;inch^2$, 전체 pixel의 수는 3.9백만개이다. 디지털 X-선 검출기에서 광도전체로서 비정질 셀레늄은 TFT 평판 패널 위에 진공 증착된다. 비정질 셀레늄의 두께는 $500\;{\mu}m$이다. 디지털 방사선 검출기의 성능을 평가하기 위해 민감도, 선형성, MTF, NPS, 그리고 DQE가 측정되었다. 선형성 평가에서는 뛰어난 선형성[($r^2$)=0.9693]을 보였다. 측정된 민감도는 인가전압 $10\;V/{\mu}m$에서 $4.16{\times}10^6\;ehp/pixel{\cdot}mR$이며, MTF는 2.5\;lp/mm에서 52%이다. 그리고 DQE는 1.5\;lp/mm에서 75%이다. 본 연구를 통해 영상평가 측정 기술의 기본적 토대를 마련하고, 측정된 값은 국내 기술로 개발중인 비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기의 임상적 사용가치가 충분함을 뒷받침할 수 있는 기초 자료로서 제공될 수 있을 것으로 판단된다.

  • PDF

비정질 셀레늄을 이용한 평판 Digital X선 검출기 개발 (Development of flat panel digital x-ray detectorusing a-Se)

  • 박지군;최장용;강상식;차병열;장기원;최준영;남상희
    • 대한디지털의료영상학회논문지
    • /
    • 제6권1호
    • /
    • pp.24-30
    • /
    • 2003
  • 평판 digital x-선 검출기는 차세대 x-ray system으로 최근 연구와 개발이 활발하게 진행되고 있는 system이다. 본 연구는 환자의 피폭 및 작업 종사자의 피폭을 최소화 할 수 있고 의료장비의 디지털화에 발맞추어 PACS 등에 사용 가능한 a-Se을 이용한 직접방식의 digital x-선 검출기 구현에 관한 것이다. Prototype digital x-선 검출기는 TFT층과 a-Se층으로 이루어져 있다. Digital x-선 검출기센서 증착과 정의 최적화 수행 결과를 참고문헌1)-4)과 비교했을 때 매우 유사함을 확인하였다. 제작된 검출기의 pixel pitch는 $139{\mu}m$였고, fill factor는 86%, 전체 검출기의 검출면적은 14"${\times}$8.5"였다. Digital 영상의 해상력을 고려하기 위해 손과 test 패턴영상을 얻었고, 58%, 3.0lp/mm의 높은 MTF를 얻을 수가 있었다. 이러한 결과로 a-Se 기반의 Digital X선 검출기가 구현되었으며 본 연구결과를 토대로 향후 digital X선 검출기 개발기술의 발전과 성능향상을 가져올 것으로 기대된다.

  • PDF

다목적실용위성 3호 Overlap 영역의 특성분석 (Characterizing Overlap Area of KOMPSAT-3)

  • 서두천;김희섭
    • 항공우주기술
    • /
    • 제10권2호
    • /
    • pp.154-162
    • /
    • 2011
  • 다목적실용위성 3호는 고해상도 0.7m 흑백영상을 촬영할 수 있는 PAN 카메라와 2.8m 다중파장대의 칼라 영상을 수집할 수 있는 멀티스펙터럴 카메라를 탑재하고 있다. 이를 통하여 취득한 위성영상은 국토관리, 농업, 환경, 해양감시 및 GIS등의 광범위한 분야에 활용될 예정이다. 다목적실용위성3호의 15km의 관측폭을 가지는 영상을 생성하기 위해, 각 detector의 양 끝단의 20 pixel을 제외하고 24,020 픽셀로 구성된다. 이러한 크기의 CCD를 하나의 CCD로 구성하는 것은 매우 어렵기 때문에 다목적실용위성 3호는 12,080 픽셀로 구성된 두 detector로 구성되며, 따라서 두 detector의 기하학적 특성이 각기 다른 특징을 가지게 된다. 본 연구에서는 다목적실용위성3호의 한 밴드내의 기하학적 특성을 분석하기 위한 시뮬레이션 영상의 생성과정을 서술하고자 한다.

이미지 퍼지화 기반 Canny 에지 검출기 설계에 관한 연구 (A Study on Canny Edge Detector Design Based on Image Fuzzification)

  • 박미영;김철원;박종훈
    • 한국정보통신학회논문지
    • /
    • 제15권9호
    • /
    • pp.1925-1931
    • /
    • 2011
  • 본 논문에서는 Canny 에지 검출 알고리즘의 핵심이라 할 수 있는 언어적인 애매한 개념인 "좋은 검출"과 "좋은 지역화" 문제를 퍼지 추론 방식을 통해 처리하는 접근방식을 제안하고, 그레이 스케일 이미지에 관해 퍼지 규칙 기반의 Canny 에지 검출기를 설계한다. 설계의 핵심은 화소들의 그레이 레벨들을 몇 가지의 언어적인 변수들로 분할한 다음에 퍼지 추론 규칙에 따라 편미분 계수들을 근사시키는데 있다. 이러한 접근방식은 기울기 및 기울기 변화에 따른 퍼지 제어 기법과 유사한 측면을 가진다. 이러한 작업을 바탕으로 퍼지 규칙 기반 Canny 에지 검출기를 구현하고, 결과들을 기존 방법과 비교한다. 특히, 제안된 접근 방식은 좁은 동적 범위의 그레이 레벨 이미지의 에지 검출 및 선명화에 있어서 장점을 가진다.

대면적 X-ray 검출기를 위한 분할 구동 시스템 (Seperate Driving System For Large Area X-ray Detector In Radiology)

  • 이동길;박지군;김대환;남상희;안상호;박효덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.388-391
    • /
    • 2003
  • The properties of these detectors can be controlled by electronics and exposure conditions. Flat-panel detectors for digital diagnostic imaging convert incident x-ray images to charge images. Flat panel detectors gain more interest real time medical x-ray imaging. Active area of flat panel detector is $14{\times}17$ inch. Detector is based on a $2560{\times}3072$ away of photoconductor and TFT pixels. X-ray conversion layer is deposited upper TFT array flat panel with a 500m by thermal deposition technology. Thickness uniformity of this layer is made of thickness control technology(5%) of thermal deposition system. Each $139m{\times}139m$ pixel is made of thin film transistor technology, a storage capacitor and charge collection electrode having geometrical fill factor of 86%. Using the separate driving system of two dimensional mosaic modules for large area, that is able to 4.2 second per frame. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system..

  • PDF