• 제목/요약/키워드: Detector

검색결과 6,223건 처리시간 0.039초

a-Se을 이용한 디지털 X-선 검출기의 Discharge Erasing Method에 관한 연구 (Study of Discharge Erasing Method of a-Se based Digital X-ray Detector)

  • 이동길;박지군;최장용;강상식;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.395-398
    • /
    • 2002
  • Many research group started study to develope x-ray detector using thin film transistor from 1970. But realization of TFT based x-ray detector development was caused by progress of thin film transistor liquid crystal display(TFTLCD) device technology in 1990. The main current of TFT technology is display device. Research results expend TFT technology field from display device to sensor manufacture technology. These days many research group in the world realize various digital x-ray detector. In this study, We compare discharge erasing method to visible light erasing method in a-Se based digital x-ray detector. Visible light erasing method is known reset process in direct conversion x-ray detector. Digital x-ray detector using visible light erasing method is not adaptive for conventional x-ray device, because of its thickness. And it is not avaliable for real-time imaging for digital fluoroscopy, because of its long reset time. In this study we overcome these limitations and show new idea for real-time imaging method.

  • PDF

화생방 보호의 성능평가를 위한 무선 실시간 가스 검출기 개발 (Development of Wireless Real-Time Gas Detector System for Chemical Protection Performance Test of Personal Protective Equipment)

  • 가동하
    • 한국군사과학기술학회지
    • /
    • 제23권3호
    • /
    • pp.294-301
    • /
    • 2020
  • Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.

천장제트기류에 대한 국내 정온식 열감지기의 작동온도 및 반응시간지수(RTI)에 관한 DB 구축 (DB Construction of Activation Temperature and Response Time Index for Domestic Fixed-temperature Heat Detectors in Ceiling Jet Flow)

  • 윤가영;한호식;문선여;박충화;황철홍
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.35-42
    • /
    • 2020
  • 성능위주 소방설계(PBD)의 안전성 평가 과정에서 화재모델링의 신뢰성 확보를 위해서는 화재감지기 작동시간의 정확한 예측성능이 요구된다. 본 연구는 대표적 화재모델인 FDS에 적용되는 정온식 열감지기의 주요 입력인자인 감지기 작동온도와 RTI의 측정을 목표로 한다. 이를 위해 화재감지기 실험 장치인 Fire detector evaluator (FDE)가 적용되었으며, 제품 인지도 조사를 통해 선정된 국내 10종의 정온식 감지기가 고려되었다. 결과적으로 감지기의 제조사별로 작동온도와 RTI는 상당한 차이가 있는 것으로 확인되었으며, 측정된 DB가 적용된 FDS의 감지기 작동시간은 보다 정확한 예측이 가능함을 확인하였다. 최종적으로 신뢰성이 확보된 정온식 열감지기의 작동온도와 RTI의 DB가 제공되었다.

Reference based simulation study of detector comparison for BNCT-SPECT imaging

  • Kim, Moo-Sub;Shin, Han-Back;Choi, Min-Geon;Monzen, Hajime;Shim, Jae Goo;Suh, Tae Suk;Yoon, Do-Kun
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.155-163
    • /
    • 2020
  • To investigate the optimal detector material for prompt gamma imaging during boron neutron capture therapy, in this study, we evaluated the characteristic regarding radiation reaction of available detector materials using a Monte Carlo simulation. Sixteen detector materials used for radiation detection were investigated to assess their advantages and drawbacks. The estimations used previous experimental data to build the simulation codes. The energy resolution and detection efficiency of each material was investigated, and prompt gamma images during BNCT simulation were acquired using only the detectors that showed good performance in our preliminary data. From the simulation, we could evaluate the majority of detector materials in BNCT and also could acquire a prompt gamma image using the six high ranked-detector materials and lutetium yttrium oxyorthosilicate. We provide a strategy to select an optimal detector material for the prompt gamma imaging during BNCT with three conclusions.

휴대형 고순도 게르마늄검출기에 대한 스펙트럼-조사선량율 변환연산자의 결정 (Determination of Spectrum-Exposure Rate Conversion Factor for a Portable High Purity Germanium Detector)

  • 곽상수;박종묵;노성기
    • Journal of Radiation Protection and Research
    • /
    • 제13권2호
    • /
    • pp.29-40
    • /
    • 1988
  • 환경방사선 측정에 이용되는 휴대형 고순도 게르마늄검출기에 대한 스펙트럼-조사선량율 변환연산자를 원판형선원의 공간분포함수와 검출기의 평면에 대한 측정효율식을 적용하여 이론적으로 유도했다. 이와 같이 구한 변환연산자와 휴대형 고순도 게르마늄검출기를 이용해 한국에너지연구소내에서 방사선 조사선량율을 측정했다. 측정한 조사선량율을 이미 알려진 3'${\phi}\;{\times}$3'NaI(Tl) 섬광검출기에 대한 변환연산자를 적용해 NaI(Tl)검출기로 측정한 조사선량율과 가압형 이온전리함으로 측정한 값과 비교했다. 고순도 게르마늄 검출기로 얻은 결과는 NaI(Tl) 검출기와 가압형 이온전리함으로 얻은 값보다 약 17-29% 낮음을 보여주었다. 이 차이는 다른 문헌에서 보인 차이와 거의 같았다. 본 논문에서 제시한 스펙트럼-조사선량율 변환연산자는 탁상용 계산기로 쉽게 계산할 수 있으며 환경방사선의 측정에 사용되는 여러 검출기에 대해서도 쉽게 적용할 수 있는 장점이 있고 지각에서 방출되는 각 핵종별로 조사선량율을 구할 수 있는 장점이 있다.

  • PDF

몬테카를로 시뮬레이션 기반 밀도에 따른 다양한 검출기 물질을 적용한 획득 영상 평가 (Evaluation of Image Quality by Using Various Detector Materials according to Density : Monte Carlo Simulation Study)

  • 이나눔;최다솜;이지수;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.459-464
    • /
    • 2021
  • The detector performance is important role in acquiring the gamma rays from patients. Among parameters of detector performances, there is density, which relates to respond to gamma rays. Therefore, we confirm the detection efficiency according to various detector materials based on the density parameter using GATE (geant4 application for emission tomography) simulation tool. The NaI (density: 3.67 g/cm3), CZT (Cadimium Zinc Telluride) (density: 5.80 g/cm3), CdTe (Cadmium Telluride) (5.85 g/cm3), and GAGG (Gadoinium Aluminum Gallium Garnet) (density g/cm3) were used as detector materials. In addition, the point source and quadrant bar phantom, which is modeled for 0.5, 1.0, 1.5, and 2.0 mm thicknesses, were modeled to confirm the quatitative analysis using sensitivity (cps/MBq) and the full width at half maximum (FWHM, mm) at the 2.0 mm bar thickness containing visual evaluation. Based on the results, the sensitivity for NaI, CZT, CdTe, and GAGG detector materials were 0.12, 0.15, 0.16, and 0.18 cps/MBq. In addition, the FWHM for quadrant bar phantom in the 2.0 mm bar thickness is 3.72, 3.69, 3.70, and 3.73 mm for NaI, CZT, CdTe, and GAGG materials, respectively. Compared with performance of detector materials according to density, the high density can improve detection efficiency in terms of sensitivity and mean count. Among these detector materials, the GAGG material is efficient for detection of gamma rays.

풍향풍속 검출기 마스트 설계 개선에 관한 연구 (A Study on the Improvement of the Mast Design for Wind Detector)

  • 김동영;박해진
    • 한국산학기술학회논문지
    • /
    • 제22권5호
    • /
    • pp.98-107
    • /
    • 2021
  • 차기군수지원함(AOE-II) 풍향풍속계 장비에 대해서 항해시운전평가 결과, 함의 우현에서는 40~90도 부근, 좌현에서는 270~320도 부근에서 풍향풍속 검출기 움직임 오작동 현상이 발생되었다. 위의 현상에 대한 원인을 분석하고 개선하는 것이 본 연구의 목적이었다. 원인 추정으로 풍향풍속 검출기가 마스트 구조물에 가려져서 불어오는 바람의 직접적인 영향을 받지 않게 되고, 마스트 구조물 뒤쪽으로 와류 기류가 형성되어 움직임 오작동 현상을 발생시켰다고 추정하였다. 위의 문제를 해결하기 위해서 신규 설치되는 마스트 야드에 풍향풍속 검출기를 이동 설치하는 방안을 검토하였다. 진동 해석을 실시하여 진동 영향성을 검토 후 신규 마스트 야드에 풍향풍속 검출기를 설치하여 항해시운전평가로 검증하였다. 개선 방안이 일부 유효하여, 신규 마스트 야드에서 풍향풍속 검출기 위치를 마스트와 이격하여 이동 설치 후 항해시운전평가로 다시 검증하였다. 풍향풍속 검출기 움직임 오작동 현상이 더 이상 발생하지 않아서 적절한 개선방안으로 확인되었다.

Development of an efficient method of radiation characteristic analysis using a portable simultaneous measurement system for neutron and gamma-ray

  • Jin, Dong-Sik;Hong, Yong-Ho;Kim, Hui-Gyeong;Kwak, Sang-Soo;Lee, Jae-Geun;Jung, Young-Suk
    • 분석과학
    • /
    • 제35권2호
    • /
    • pp.69-81
    • /
    • 2022
  • The method of measuring and classifying the energy category of neutrons directly using raw data acquired through a CZT detector is not satisfactory, in terms of accuracy and efficiency, because of its poor energy resolution and low measurement efficiency. Moreover, this method of measuring and analyzing the characteristics of low-energy or low-activity gamma-ray sources might be not accurate and efficient in the case of neutrons because of various factors, such as the noise of the CZT detector itself and the influence of environmental radiation. We have therefore developed an efficient method of analyzing radiation characteristics using a neutron and gamma-ray analysis algorithm for the rapid and clear identification of the type, energy, and radioactivity of gamma-ray sources as well as the detection and classification of the energy category (fast or thermal neutrons) of neutron sources, employing raw data acquired through a CZT detector. The neutron analysis algorithm is based on the fact that in the energy-spectrum channel of 558.6 keV emitted in the nuclear reaction 113Cd + 1n → 114Cd + in the CZT detector, there is a notable difference in detection information between a CZT detector without a PE modulator and a CZT detector with a PE modulator, but there is no significant difference between the two detectors in other energy-spectrum channels. In addition, the gamma-ray analysis algorithm uses the difference in the detection information of the CZT detector between the unique characteristic energy-spectrum channel of a gamma-ray source and other channels. This efficient method of analyzing radiation characteristics is expected to be useful for the rapid radiation detection and accurate information collection on radiation sources, which are required to minimize radiation damage and manage accidents in national disaster situations, such as large-scale radioactivity leak accidents at nuclear power plants or nuclear material handling facilities.

자외선 경화 하이드로겔을 사용한 일회용 빛 노출 검출 키트의 제조와 특성분석 (Fabrication of Disposable Light Exposure Detector Kit using UV Curable Hydrogels)

  • 김영호;김규만;;최진호;김환곤;박상주;이상학
    • 응용화학
    • /
    • 제15권1호
    • /
    • pp.17-20
    • /
    • 2011
  • A disposable light exposure detector kit has been developed by UV curing of a hydrogel material. The devised light exposure detector kit consisted of light sensitive structures, bottom plate, character sheet and sticky back plate. A light exposure detector kit has a serial light sensitive structures that contain various light sensitive dyes such as rhodamine and fluorescein. The light sensitive structure composed of UV curable hydrogel polymer material as a supporing material and photosensitive dye in a certain concentration. The fabrication procedure of the ligh exposure detector kit is very simple and fast due to UV curing procedure of a photopolymerizable hydrogel material such as poly(ethylene glycol) methyl ether acrylate (PEGMEA) and poly(ethylene glycol) diacrylate (PEGDA) with a photosensitive dye. By the proposed fabrication method, various size and shape of a light exposure detector kit could be fabricated using a flexible elastomer mold. Due to a fast and inexpensive fabrication method, the light exposure detector kit could be use a single use for various industrial applications. According to light irradation, the light sensitive structure on a light exposure detector kit could be lose its color by decomposition of a photosensitive dye chemical in the structure. Thus the amount of the exposed light on a substrate could easily be recognised by changing color or transparency of the structure.

A SCANNING CCD DETECTOR FOR SOLAR ECLIPSE OBSERVATIONS

  • YERSHOV V. N.
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.385-386
    • /
    • 1996
  • A wide-field CCD detector for solar eclipse observations is discussed. The CCD is supposed to be of a moderate size, and the image of the corona is obtained by scanning the field of view. Results of the 1995 solar eclipse observation are shown which have been made with a prototype of the scanning CCD detector.

  • PDF