• Title/Summary/Keyword: Detector

Search Result 6,190, Processing Time 0.037 seconds

A K-Ray Image Reconstruction by the Direct Detection Method (직접검출방식(直接檢出方式)에 의한 X선영상(X線影像)의 재구성(再構成)에 관(關)한 연구(硏究))

  • Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.14 no.1
    • /
    • pp.61-72
    • /
    • 1991
  • In this paper, the rotating plate method extracting signal and reconstructing original image was proposed. The rotating methode has cell detector array each of which has used in the medical diagnosis X-ray photography. The major problem using the simple horizontal moving or non-moving methode is the size and number of detector cells which have the considerable affection on the sharpness and resolution of the reconstructed image. Secondary, the estimated pixel values of non-detected real points which are placed between detector cells will be the distorted pixels in the reconstructed image. Therefore, the proposed rotating plate method has the exact distribution on the uncertain pixels which were reconstructed by conventional methods to solve there problems. And then, the image using the rotated plate's cell out put signal was reconstructed on the computer simulation. The method will rotated the detector array plate to solve the reconstruction from the detector size and number of conventional methods. The result of simulation has estimated the original pixel position and 81 pixel/mm resolution which the reconsiderlation of the detector's moving orientation, the proposed method has 25 pixel/mm resolution. These results have been represented by 3-D computer graphics.

  • PDF

A Study on Microwave-FM-CW Detection System for the Sutomatic Optimal Point Traffic Control (교통신호의 자동최적점제어를 위한 마이크로파 FM-CW 검지계통에 관한 연구)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 1973
  • An automatic point traffic control method is recommended for more idealistic traffic flow over coarse road netowrks. The automatic control apparatus recommended, consists of a transceiver, amplifier, digital-to-analog converter, signal light controller for emergency and steady state, and digital counter as monitor. The transmitter sends a signal to the target vy means of Microwave-FM-CW and a diode detector picks up the echo signal. Thus the operation of the entire system will be carried out through an open loop state. Some factors necessary for an ideal detector system are rapid response, longevity and stability. An analytical method of the Doppler effect substitutes the conventional frequency deviation into the amplitude of detector output. The changing rate of amplitude is proportional to the voltage of the detector output. Some induced formula from Maxwell's radiation field theory ensures this new method, and, new method, and proves the fact with an experimental data presentation. Stability depends upon Klystron as an oscillator and a diode as a detector. the transceiver installation affects on the response and sensitivity of the system. In accordance with the detector output, several targets are easily classified by amplitudes on the scope. The traffic flow, i.e., target movement which is analyzed by the amplitude method, is shown through the scope and indicates it on the digital counter. The best efficiency for the amplitude analysis can be attained through use of an antenna having the highest sensitivity.

  • PDF

RF Power Detector for Location Sensing

  • Kim, Myung-Sik;Kubo, Takashi;Chong, Nak-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1771-1774
    • /
    • 2005
  • Recently, RFID has become popular in the field of remote sensing applications. Location awareness is one of the most important keys to deploying RFID for advanced object tracking. Generally, multiple reference RF stations or additional sensors are used for the location sensing with RFID, but, particularly in indoor environments, spatial layout and cost problems limit the applicability of those approaches. In this paper, we propose a novel method for location sensing with active RFID systems not requiring the need for reference stations or additional sensors. The system triangulates the position of RF signal source using the signal pattern of the loop antenna connected to the power detector. The power detector consists of a signal strength detector and a signal analysis unit. The signal analysis unit indicates the signal strength and serial number using the signal from the strength detector, and provides the direction of the signal to the application target. We designed three different signal analysis units depending on the threshold type. The developed system can sense the direction to the transponder located over 10 m away within the maximum error of $5^{\circ}$. It falls within a reasonable range in our normal office environment.

  • PDF

Optimization of airborne alpha beta detection system modeling using MCNP simulation

  • Sung, Si Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.841-845
    • /
    • 2020
  • An airborne alpha beta detection system using passivated implanted planar silicon (PIPS) detector was modeled with the MCNP6 code and its resolution and detection efficiency were analyzed. Simulation of the resolution performed using the Gaussian energy broadening (GEB) function showed that the full width at half maximum (FWHM) of 35.214 keV for alpha particles was within 34-38 KeV, which is the FWHM range of the actual detector, and the FWHM of 15.1 keV for beta particles was constructed with a similar model to 17 keV, which is the FWHM range of an actual detector. In addition, the detection efficiency and the resolution were simulated according to the distance between the detector and the air filter. When the distance was decreased to 0.2 cm from 0.8 cm, the efficiency of the alpha and beta particles detection decreased from 5.33% to 4.89% and from 5.64% to 4.27%, respectively, and the FWHM of the alpha and beta particles improved from 40.9 KeV to 29.84 keV and 25.76 keV-13.27 keV, respectively.

Hue-based Noise-tolerant Corner Detector Robust to Shadows (그림자에 강건한 색상 기반 내잡음성 코너 검출자)

  • 박기현;박은진;최흥문
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.6
    • /
    • pp.239-245
    • /
    • 2004
  • A hue-based noise-tolerant corner detector is proposed for the exact detection of the real corners in spite of the shadows and random noise. Based on the fact that the hue gradient at the border of the opaque objects' shadow is smaller than the intensity gradient in HSI (hue-saturation-intensity) color space, the effects of shadow are eliminated by introducing the hue-weighted combination of vector gradient to the proposed corner detector. Furthermore, the proposed corner detector is robust to random noise by offsetting the contribution to the corner candidate when the polarities of the color gradients of the pixel pairs are out of phase each other. Results of the experiment show that the proposed corner detector can effectively detect the real corners.

Novel control scheme for the absence of the thermoelectric(TEC) of infrared detector in an Uncooled thermal system (비냉각 열상시스템에서의 적외선 검출기의 열전소자(TEC) 부재에 대한 효율적인 제어기법)

  • Kim, Yong-Jin;Seo, Jae-Gil;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2335-2340
    • /
    • 2012
  • The detector is an uncooled detector system that functions inside the thermoelectric cooler (TEC) equipped with features instead of the cooler. The function of the thermoelectric device to control the temperature of the detector based on a function of temperature to prevent degradation of image quality to perform the role, the latest technology trend by removing the thermoelectric device size, cost a lot of effort to reduce has been studied. In this paper, It would be proposed of the actual test result using real chamber environment of for the best TECless algorithm as to minimize the degradation of image quality and obtain the low price of the uncooled detector.

The Test Statistic of the Two Sample Locally Optimum Rank Detector for Random Signals in Weakly Dependent Noise Models (약의존성 잡음에서 두 표본을 쓰는 국소 최적 확률 신호 검파기의 검정 통계량)

  • Bae, Jin-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.8C
    • /
    • pp.709-712
    • /
    • 2010
  • In this paper, the two sample locally optimum rank detector is obtained in the weakly dependent noise with non-zero temporal correlation between noise observations. The test statistic of the locally optimum rank detector is derived from the Neyman-Pearson lemma suitable for the two sample observation models, where it is assumed that reference observations are available in addition to regular observations. Two-sample locally optimum rank detecter shows the same performance with the one-sample locally optimum rank detector asymptotically. The structure of the two-sample rank detector is simpler than that of the one-sample rank detector because the sign statistic is not processed separately.

Mixed LMSF Blind Multiuser Detector for DS-CDMA Systems (DS-CDMA 시스템을 위한 혼합 LMSF 블라인드 다중 사용자 검출)

  • Park, Sung-Wook;Park, Jong-Wook
    • 전자공학회논문지 IE
    • /
    • v.43 no.2
    • /
    • pp.75-79
    • /
    • 2006
  • Blind techniques without the help of training sequences are able to detect the information signal which has the minimal information of desired user. In this paper, we proposed the blind multiuser detector using the hybrid cost function to cancel the multiple user interference in direct sequence code division multiple access systems. The cost function of proposed blind multiuser detector is the hybrid type which joints both least mean square(LMS) algorithm and least mean fourth(LMF) algorithm. We evaluate the bit error rate(BER) performance of proposed blind multiuser detector under additive white Gaussian noise channel. Simulation results show that the proposed blind detector has an about 3dB of signal to noise ratio more than blind minimum output energy(MOE) multiuser detector under existing active user 20.

Combined X-ray CT-SPECT System with a CZT Detector

  • Kwon, Soo-Il;Koji Iwata;Hasegawa, B-H
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.379-381
    • /
    • 2002
  • A single CdZnTe detector is tested for suitability in a prototype CT/ SPECT system designed to acquire both emission and transmission data. The detector has the size of 1${\times}$l-cm$^2$ with 4${\times}$4 1.5${\times}$l.5mm$^2$ pixellated anodes. Since the detector is smaller than imaged object, we translated it in an arc centered at the x-ray tube to image larger objects. Pulse counting electronics with very short shaping time (50 ns) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3${\times}$10$\^$5/ counts per second per detector element is achieved. The energy resolution of 122-keV gamma-ray is measured to be 14%. We have characterized the system performance by scanning a radiographic resolution phantom .and the Hoffman brain phantom. The spatial resolution of CT and SPECT are about 1 mm and 7 mm, respectively.

  • PDF

A Study on the Response Characteristics Depending on Service Life of Ionization Smoke Detector (이온화식연기감지기의 사용기간에 따른 응답특성 연구)

  • Baek, Won-Don;Kim, Shi-Kuk;Ok, Kyung-Jea;Lee, Chun-Ha;Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.61-64
    • /
    • 2008
  • This paper studied on the response characteristics depending on service life of ionization smoke detector. The experimental samples used ionization smoke detectors (360 EA) for over 5 years which were influenced by environment set up with fire objects. The experimental method performed operate and non-operate test according to 'Type Approval and Technical Regulation of Detector (KOFEIS 0301)', for estimate the response characteristics of ionization smoke detector depending on service life. The results showed that their response characteristics were rapidly decreasing when the longer their using period. Accordingly, it is desirable that ionization smoke detector has to be changed for early fire detection when passed their service life.