• Title/Summary/Keyword: Detection sensitivity

Search Result 2,474, Processing Time 0.029 seconds

Sensitive and Selective Electrochemical Glucose Biosensor Based on a Carbon Nanotube Electronic Film (탄소나노튜브 전자 필름을 이용한 고감도-고선택성 전기화학 글루코스 센서)

  • Lee, Seung-Woo;Lee, Dongwook;Seo, Byeong-Gwuan
    • Applied Chemistry for Engineering
    • /
    • v.33 no.2
    • /
    • pp.188-194
    • /
    • 2022
  • This work presents a non-destructive and straightforward approach to assemble a large-scale conductive electronic film made of a pre-treated single-walled carbon nanotube (SWCNT) solution. For effective electron transfer between the immobilized enzyme and SWCNT electronic film, we optimized the pre-treatment step of SWCNT with p-terphenyl-4,4"-dithiol and dithiothreitol. Glucose oxidase (GOx, a model enzyme in this study) was immobilized on the SWCNT electronic film following the positively charged polyelectrolyte layer deposition. The glucose detection was realized through effective electron transfer between the immobilized GOx and SWCNT electronic film at the negative potential value (-0.45 V vs. Ag/AgCl). The SWCNT electronic film-based glucose biosensor exhibited a sensitivity of 98 ㎂/mM·cm2. In addition, the SWCNT electronic film biosensor showed the excellent selectivity (less than 4 % change) against a variety of redox-active interfering substances, such as ascorbic acid, uric acid, dopamine, and acetaminophen, by avoiding co-oxidation of the interfering substances at the negative potential value.

Development of Korean Adult Patients Delirium Screening Tool (한국형 성인 환자 섬망 선별 도구 개발)

  • Jeong, Hye Won;Moon, Sun Hee;Choi, Myoung Lee;Lee, Jung A;Ahn, Shin Hye;Jeon, Ji Hye;You, Ji Na;Kim, Hee Jin;Byeon, Ji Eun;Kim, Sook Young;Sung, In Suk
    • Journal of Korean Clinical Nursing Research
    • /
    • v.29 no.2
    • /
    • pp.198-209
    • /
    • 2023
  • Purpose: The purpose of this study was to develop a Korean Adult Patients Delirium Screening Tool (K-APDS) for those admitted to general wards, and to verify its reliability and validity. Methods: For the development of the tool, 12 items were derived through the results of literature review and focus group interviews with general ward nurses, and the content validity was confirmed by experts. To verify the reliability and validity of the developed tool, 317 adult patients who were admitted to general wards of three tertiary general hospitals from October to November 2022 were evaluated by the attending nurse and data were collected. Results: After factor analysis for construct validity verification, two factors were extracted, which explained 60.1% of the total variance. After the validation of the control group, the difference in the delirium incidence scores calculated using the K-APDS between the delirium group and non-delirium group was very significant (Z=-10.82, p<.001). To verify the criterion validity, K-APDS, Delirium Observation Screening, and Pearson's correlation coefficient were checked and found to be .94 (p<.001). The predictive validity test reported that the sensitivity was 91.1%, specificity was 82.4%, positive predictive value was 52.6%, and negative predictive value was 97.8%. The reliability of K-APDS was found to be high with Cronbach's ⍺=.91. Conclusion: K-APDS can screen for delirium with 2 or more points, excellent validity and reliability have been verified. Therefore, this tool could be applied immediately in the clinical field, and will contribute to the early detection of delirium, enabling rapid interventions.

The Efficacy of Detecting a Sentinel Lymph Node through Positron Emission Tomography/Computed Tomography (근골격계 악성 종양 환자의 림프절 전이 발견을 위한 양전자 방출 컴퓨터 단층 촬영기(Positron Emission Tomography/Computed Tomography)의 유용성)

  • Shin, Duk-Seop;Na, Ho Dong;Park, Jae Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.509-518
    • /
    • 2019
  • Purpose: Lymph node metastasis is a very important prognostic factor for all skin cancers and some sarcomas. A sentinel lymph node (SLN) biopsy is the most useful technique for identifying SLNs. Recently, a new generation of diagnostic tools, such as single photon emission computed tomography/computed tomography (SPECT/CT) and positron emission tomography/CT (PET/CT) enabled the detection of SLNs. This study compared the efficacy of PET/CT for detecting lymph node metastases with a SLN biopsy in a single medical center. Materials and Methods: From 2008 to 2018, 72 skin cancers of sarcoma patients diagnosed with some lymph node involvement in a whole body PET/CT reading were assessed. Patients suspected of lymph node metastasis were sent to biopsy and those suspected to be reactive lesions were observed. The analysis was performed retrospectively using the medical records, clinical information, PET/CT readings, and pathology results. Results: The age of patients ranged from 14 to 88 years and the mean follow-up period was 2.4 years. Twenty-two patients were suspected of a lymph node metastasis and confirmed. The sensitivity, specificity, positive predictive value and negative predictive value of PET/CT images in sarcoma and non-sarcoma tumors were increased significantly when the expert's findings were considered together. Conclusion: PET/CT is effective in detecting lymph node metastases.

Simultaneous GC/MS Analyses of Organic acids and Amino acids in Urine using TMS-TFA derivative (TMS-TFA 유도체화를 이용한 소변여지 중 유기산과 아미노산의 GC/MS 동시분석)

  • Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.107-114
    • /
    • 2006
  • Early diagnosis and medical intervention are critical for the treatment of patients with metabolic disorders. A rapid analytical method was developed for simultaneous quantification of organic acids and amino acids in urine without labor-intensive pre-extraction procedure showing high sensitivity and specificity. A new method consisted of simple two-step trimethylsilyl (TMS)-trifluoroacetyl (TFA) derivatization using GC/MS-selective ion monitoring (SIM). Filter paper urine specimens were dried under nitrogen after being fortified with internal standard (tropate) in a mixture of distilled water and methanol. Methyl orange was added to the residue as indicator reagent. Silyl derivative of carboxylic functional group was followed by trifluoroacetyl derivative for amino functional group. N-methyl-N-(trimethylsilyl-trifluoroacetamide) and N-methyl-bistrifluoroacetamide were consecutively added and heated for 15-20 min at $65^{\circ}C-70^{\circ}C$, for TMS-TFA derivative, respectively. This reactant was analyzed by GC/MS-SIM. Linear dynamic range showed 0.001-50 mg with the detection limit of (S/N=3) 10-200 ng, and the quantification limit of 80-900 ng in urine. Correlation coefficient of regression line was 0.994-0.998. When the method was applied to the patients 'urine, it clearly differentiated the normal from the patient with metabolic disorder. The study showed that the developed method could be the method of choices in rapid and sensitive screening for organic aciduria and amino acidopathy.

Development of Temperature Compensated Micro Cone by using Fiber Optic Sensor (광섬유를 이용한 온도 보상형 마이크로콘의 개발)

  • Kim, Raehyun;Lee, Woojin;Yoon, Hyung-Koo;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4C
    • /
    • pp.163-174
    • /
    • 2009
  • Mechanical device using the load cell or strain gage sensor can be influenced by tempearute changes because temperature change can cause a shift in the load cell or straing gage output at zero loading. In this paper, micro cone penetrometers with 1~7mm in diameter, are developed by using an optical fiber sensor (FBG: Fiber Bragg Grating) to compensate the continous temperature change during cone penetration test. Note the temperature compensated method using optical fiber sensor which has hair-size in diameter, and is not affected by environmental conditions because the measured data is the wavelength shifting of the light instead of the intensity of the electric voltage. Temperature effect test shows that the output voltage of strain gage changes and increases with an increase in the temperature. A developed FBG cone penetrometer, however, achieves excellent temperature compensation during penetration, and produces continuous change of underground temperature. In addition, the temperature compensated FBG cone shows the excellent sensitivity and detects the interface of the layered soils with higher resolution. This study demonstrates that the fiber optic sensor renders the possibility of the ultra small size cone and the new fiber optic cone may produce more reliable temperature compensated tip resistance.

Species-specific Marker Development for Environmental DNA Assay of Endangered Bull-head Torrent Catfish, Liobagrus obesus (멸종위기어류 퉁사리의 환경 DNA 분석을 위한 종 특이 마커 개발)

  • Yun, Bong Han;Kim, Yong Hwi;Sung, Mu Sung;Han, Ho-Seop;Han, Jeong-Ho;Bang, In-Chul
    • Korean Journal of Ichthyology
    • /
    • v.34 no.3
    • /
    • pp.208-217
    • /
    • 2022
  • We wanted to develop a real-time PCR assay capable of detecting Liobagrus obesus in environmental DNA (eDNA) extracted from freshwater samples using a pair of species-specific primers and probe for the endangered fish, L. obesus. The species-specific primers and probe were designed in consideration of single nucleotide polymorphisms between 65 species of freshwater fish living in the Republic of Korea within the cytochrome b (cytb) gene of mitochondrial DNA. The species-specific primers and probe, in the real-time PCR assay, showed high specificity as only the L. obesus genomic DNA (gDNA) was found to be positive in the specificity verification using 65 species gDNA of freshwater fish in the Republic of Korea. In addition, in the detection limit analysis using the serial dilution concentrations of L. obesus gDNA, it was found that it was possible to detect up to 0.2 pg, showing high sensitivity. Afterwards, using the species-specific primers and probe, real-time PCR assay was performed on freshwater samples obtained from 8 stations in the mid-upper basin of Geum River. As a result, the cytb gene of L. obesus was detected in total 5 stations including all 3 stations where this species was collected at the time of field survey. Therefore, the species-specific primers and probe developed in present study, and the real-time PCR assay using them, can accurately detect the cytb gene of L. obesus from eDNA samples, which can be utilized to monitor the existing habitats of this species and to discover potential new habitats.

Neurobiological Factors of Suicide (자살의 신경생물학적 요인)

  • Song, Hoo Rim;Woo, Young Sup;Jun, Tae Youn
    • Mood & Emotion
    • /
    • v.10 no.1
    • /
    • pp.13-21
    • /
    • 2012
  • Suicide is a complex behavior associated with various neurobiological and psychosocial factors. It is considered that genetic polymorphism combined with environmental stress such as child-adolescent trauma make differences in neurobiological systems, which cause psychiatric disorders or pessimistic personality, impulse-aggressive behaviors, lack of judgment, and finally result in suicidal behavior. Much progress in the neurobiology of suicide has been made over the several decades. There seems to be a hereditary disposition to suicide independent of psychiatric disorder. The changes in neurotransmitters, neurohormones, neurotrophic factors, cytokines, lipid metabolisms related with their genetic polymorphism can contribute to disturbance of signal transductions and neuronal circuits vulnerable to suicide. It is likely that the main factors are dysfunctions of serotonin (5-HT) and hypothalamus-pituitary-adrenal (HPA) axis. Our understanding about the neurobiology of suicide is still limited. However, clinical practice could be assisted by neurobiological findings capable of making the detection of risk populations with higher sensitivity and the development of new treatment interventions. The settlement of biological markers in suicidal behaviors and their relationships is required.

Monitoring of Crop Water Stress with Temperature Conditions Using MTCI and CCI (가뭄과 폭염 조건에서 MTCI와 CCI를 이용한 수분 스트레스 평가)

  • Kyeong-Min Kim;Hyun-Dong Moon;Euni Jo;Bo-Kyeong Kim;Subin Choi;Yuhyeon Lee;Yuna Lee;Hoejeong Jeong;Jae-Hyun Ryu;Hoyong Ahn;Seongtae Lee;Jaeil Cho
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1225-1234
    • /
    • 2023
  • The intensity of crop water stress caused by moisture deficit is affected by growth and heat conditions. For more accurate detection of crop water stress state using remote sensing techniques, it is necessary to select vegetation indices sensitive to crop response and to understand their changes considering not only soil moisture deficit but also heat conditions. In this study, we measured the MERIS terrestrial chlorophyll index (MTCI) and chlorophyll/carotenoid index (CCI) under drought and heat wave conditions. The MTCI, sensitive to chlorophyll concentration, sensitively decreased on non-irrigation conditions and the degree was larger with heat waves. On the other hand, the CCI, correlated with photosynthesis efficiency, showed less sensitivity to water deficit but had decreased significantly with heat waves. After re-irrigation, the MTCI was increased than before damage and CCI became more sensitive to heat stress. These results are expected to contribute to evaluating the intensity of crop water stress through remote sensing techniques.

Heterostructures of SnO2-Decorated Cr2O3 Nanorods for Highly Sensitive H2S Detection (고감도 H2S 감지를 위한 SnO2 장식된 Cr2O3 nanorods 이종구조)

  • Jae Han Chung;Yun-Haeng Cho;Junho Hwang;Su hyeong Lee;Seunggi Lee;See-Hyung Park;Sungwoo Sohn;Donghwi Cho;Kwangjae Lee;Young-Seok Shim
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.40-47
    • /
    • 2024
  • The creation of vertically aligned one-dimensional (1D) nanostructures through the decoration of n-type tin oxide (SnO2) on p-type chromium oxide (Cr2O3) constitutes an effective strategy for enhancing gas sensing performance. These heterostructures are deposited in multiple stages using a glancing angle deposition technique with an electron beam evaporator, resulting in a reduction in the surface porosity of the nanorods as SnO2 is incorporated. In comparison to Cr2O3 films, the bare Cr2O3 nanorods exhibits a response 3.3 times greater to 50 ppm H2S at 300℃, while the SnO2-decorated Cr2O3 nanorods demonstrate an eleven-fold increase in response. Furthermore, when subjected to various gases (CH4, H2S, CO2, H2), a notable selectivity toward H2S is observed. This study paves the way for the development of p-type semiconductor sensors with heightened selectivity and sensitivity towards H2S, thus advancing the prospects of gas sensor technology.

Usefulness of Silent MRA for Evaluation of Aneurysm after Stent-Assisted Coil Embolization

  • You Na Kim;Jin Wook Choi;Yong Cheol Lim;Jihye Song;Ji Hyun Park;Woo Sang Jung
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.246-255
    • /
    • 2022
  • Objective: To determine the usefulness of Silent MR angiography (MRA) for evaluating intracranial aneurysms treated with stent-assisted coil embolization. Materials and Methods: Ninety-nine patients (101 aneurysms) treated with stent-assisted coil embolization (Neuroform atlas, 71 cases; Enterprise, 17; LVIS Jr, 9; and Solitaire AB, 4 cases) underwent time-of-flight (TOF) MRA and Silent MRA in the same session using a 3T MRI system within 24 hours of embolization. Two radiologists independently interpreted both MRA images retrospectively and rated the image quality using a 5-point Likert scale. The image quality and diagnostic accuracy of the two modalities in the detection of aneurysm occlusion were further compared based on the stent design and the site of aneurysm. Results: The average image quality scores of the Silent MRA and TOF MRA were 4.38 ± 0.83 and 2.78 ± 1.04, respectively (p < 0.001), with an almost perfect interobserver agreement. Silent MRA had a significantly higher image quality score than TOF MRA at the distal internal carotid artery (n = 57, 4.25 ± 0.91 vs. 3.05 ± 1.16, p < 0.001), middle cerebral artery (n = 21, 4.57 ± 0.75 vs. 2.19 ± 0.68, p < 0.001), anterior cerebral artery (n = 13, 4.54 ± 0.66 vs. 2.46 ± 0.66, p < 0.001), and posterior circulation artery (n = 10, 4.50 ± 0.71 vs. 2.90 ± 0.74, p = 0.013). Silent MRA had superior image quality score to TOF MRA in the stented arteries when using Neuroform atlas (4.66 ± 0.53 vs. 3.21 ± 0.84, p < 0.001), Enterprise (3.29 ± 1.59 vs. 1.59 ± 0.51, p = 0.003), LVIS Jr (4.33 ± 1.89 vs. 1.89 ± 0.78, p = 0.033), and Solitaire AB stents (4.00 ± 2.25 vs. 2.25 ± 0.96, p = 0.356). The interpretation of the status of aneurysm occlusion exhibited significantly higher sensitivity with Silent MRA than with TOF MRA when using the Neuroform Atlas stent (96.4% vs. 14.3%, respectively, p < 0.001) and LVIS Jr stent (100% vs. 20%, respectively, p = 0.046). Conclusion: Silent MRA can be useful to evaluate aneurysms treated with stent-assisted coil embolization, regardless of the aneurysm location and type of stent used.