• Title/Summary/Keyword: Detection sensitivity

Search Result 2,447, Processing Time 0.029 seconds

A Study for Co-channel Interference Cancelation Algorithm with Channel Estimation for WBAN System Application (WBAN 환경에서 채널 추정 기반의 공용 채널 간섭 제거 기술)

  • Choi, Won-Seok;Kim, Jeong-Gon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.476-482
    • /
    • 2012
  • In this paper, we analyze and compare several co-channel interference mitigation algorithms for WBAN application in 2.4 GHz ISM frequency bands. ML (Maximum Likelihood), OC (Optimal Combining) and MMSE (Minimum Mean Square Error) has been considered for the possible techniques for interference cancellation in view of the trade off between the performance and the complexity of implementation. Based on the channel model of IEEE 802.15.6 standard, simulation results show that ML and OC attains the lower BER performance than that of MMSE if we assume the perfect channel estimation. But, ML and OC have the additional requirement of implementation for his own and other users's channel estimation process, hence, besides the BER performance, the complexity of implementation and the sensitivity to channel estimation error should be considered since it requires the simple and small sized equipment for WBAN system application. In addition, the gap of detection BER performance between ML, OC and MMSE is much decreased under the imperfect channel estimation if we adopt real channel estimation process, therefore, in order to apply to WBAN system, the trade off between the BER performance and complexity of implemetation should be seriously considered to decide the best co-channel interference cancellation for WBAN system application.

Monitoring of pH and dissolved oxygen in microorganism fermentation processes using a 24-well microplate (24-웰 마이크로 플레이트를 이용한 미생물 발효공정에서 pH 및 용존산소의 모니터링)

  • Kim, Sun-Yong;Kim, Chun-Kwang;Sohn, Ok-Jae;Rhee, Jong-Il
    • KSBB Journal
    • /
    • v.24 no.2
    • /
    • pp.207-211
    • /
    • 2009
  • In this study, the sensing membranes for detection of pH and dissolved oxygen(DO) were prepared by immobilizing 6-aminofluorescein or ruthenium complex onto the sol-gel matrixes of GPTMS, MTMS, and TEOS and then recoated with the mixture of hydrophobic sol-gel and graphite for light insulation. The pH and DO sensing membranes recoated with the light insulation layer showed a higher sensitivity than those without light insulation layer. The sensing membranes were immobilized on the wells of 24-well microplate and used to monitor the fluorescence intensity for pH and DO in E.coli JM109 and P.pastoris X-33 fermentation processes. The change of the fluorescence intensity in the DO sensing membrane agreed with the growth patterns of microorganisms, that the membranes are valuable to monitor the DO in fermentation processes. In the case of pH monitoring, the fluorescence intensity has showed good correlation to the off-line pH data, that the pH membranes are valuable to monitor pH values in fermentations.

Matrix Modification for Atomic Absorption Spectrophotometric Determination of Volatile Elements (Ⅱ). Determination of Trace Germanium by Electrothermal Atomization (휘발성 원소들의 원자흡수 분광분석을 위한 매트릭스 개선에 관한 연구(제2보). 전열 원자화에 의한 흔적량 게르마늄의 정량)

  • Choi, Ho Sung;Choi, Jong Moon;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.2
    • /
    • pp.109-116
    • /
    • 1996
  • A matrix modification was studied for the determination of trace germanium in mineral waters by electrothermal atomic absorption spectrophotometry (ET-AAS). For this, the type and quantity of modifier as well as the use of auxiliary modifier were investigated to realize the efficient modification. Germanium suffers from low sensitivity and poor reproducibility in ET-AAS determination because of the premature loss of germanium via volatile germanium monoxide formation when heated in the presence of carbon. Therefore, the addition of a matrix modifier is necessary to stablize the germanium, thermally and chemically. By the addition of palladium (10 ${\mu}g/mL)$ as a single modifier to the sample containing 500 ng/mL germanium, the charring temperature could be raised from 800 to $1000^{\circ}C$, and its absorbance was also increased, but the atomization temperature was not raised. In this case, the absorbance of germanium was not changed in the range of 10∼70 ${\mu}g/mL$ of palladium added. On the other hand, it was considered that the use of a mixed modifier could modifiy the matrix more effectively than with a single modifier. The best results were obtained by using 1% ammonium hydroxide as an auxiliary modifier together with 10 ${\mu}g/mL$ palladium. The charring temperature could be raised from 800 to $1100^{\circ}C$, without any change of the atomization temperature. With above optimum conditions, the trace amount of germanium in several mineral waters were determined by a calibration curve method, and good recoveries of more than 95% were also obtained in the samples in which a given amount of germanium was spiked. The detection limit of this method was about 6.9 ng/mL.

  • PDF

Detection of Long Period Seismic Events by Using a Portable Gravity Meter, gPhone (이동식 중력계(gPhone)를 활용한 장주기 지진 이벤트 관측)

  • Lee, Won Sang;Seo, Ki-Weon;Eom, Jooyoung;Sheen, Dong-Hoon;Lee, Choon-Ki;Park, Yongcheol;Yun, Sukyoung;Yoo, Hyun Jae
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.1
    • /
    • pp.31-34
    • /
    • 2015
  • A gravity meter has been used for exploring subsurface mineral resources and monitoring long-period events such as Earth tides. Recently, researchers found several other intriguing features that we could even detect large teleseismic earthquakes and monitor seismic ambient noise using gravimeters. The zero-length spring suspension technology gives the gPhone (Micro-g LaCoste) excellent low frequency sensitivity, which may have implications for investigating much longer-period natural events (e.g., Earth's hum, tsunami waves, etc.). In this study, we present preliminary results through temporary operation of the gPhone at Geumsan in South Korea for 9 months (Nov. 2008-Jul. 2009). The gPhone successfully recorded large teleseismic events and showed a clear seasonal variation of the Double frequency microseisms during its operation period.

Evaluation or potency or panoramic radiography for estimating the position of maxillary impacted canines using 3D CT (3D CT를 이용한 파노라마 방사선 사진상 상악 매복 견치 위치 정보의 유용성 평가)

  • Kim, Hye-Jung;Park, Hyo-Sang;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.265-274
    • /
    • 2008
  • Objective: The aim of this study was to evaluate the potency of panoramic radiography for the detection of maxillary impacted canines. Methods: Twenty-five patients were selected, comprised of 7 males (mean age: 10.9 years, range: 8.5 - 14.5 years) and 18 females (mean age: 10.9 years, range: 8.2 - 15.7 years). In total, thirty-five maxillary impacted canines were estimated. The position of the canine and root resorption of adjacent teeth were evaluated on panoramic radiography and 3D CT. Results: Except for angulation to the occlusal plane, the other parameters, such as tooth length, crown width, vertical distance and lateral shift showed larger values on panoramic radiography compared to 3D CT. In palatally impacted cases, the angulation of canine was smaller, and the vertical distance to the occlusal place was larger on panoramic radiography than 3D CT. For labially impacted canines, tooth length, crown width, and angulation to the occlusal plane were similar for the two methods. The sensitivity for detecting root resorption on panoramic radiography was calculated as being 33.3% of 3D CT. Conclusions: The position of labially impacted canines can be effectively estimated using panoramic radiography, but palatally impacted canines need further investigation such as 3D CT for proper diagnosis.

Chest CT Parameters to Predict the Major Adverse Events in Acute Submassive Pulmonary Embolism (신종인플루엔자 폐렴환자에서 임상적 악화와 연관된 초기 전산화 단층촬영 소견)

  • Ryoo, Seung-Mok;Kim, Won-Young;Lee, Choong-Wook;Sohn, Chang-Hwan;Seo, Dong-Woo;Lee, Yoon-Seon;Lee, Jae-Ho;Oh, Bum-Jin;Kim, Won;Lim, Kyoung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.2
    • /
    • pp.103-107
    • /
    • 2010
  • Background: The aim of the present study was to evaluate whether findings on initial chest computed tomography (CT) of influenza pneumonia can help predict clinical outcome. Methods: We reviewed all adult patients admitted to the Emergency Department (ED) with a confirmed diagnosis of novel influenza A H1N1 virus (2009 H1N1) pneumonia, who underwent chest CT upon admission between Aug 26, 2009 and Jan 31, 2010. Radiologic findings were characterized by type and pattern of opacities and zonal distribution. Clinical outcome measures were intensive care unit (ICU) admission, mechanical ventilation, and inhospital death. Results: Of 59 patients diagnosed with 2009 H1N1 pneumonia, 41 (69.5%) underwent chest CT on admission into ED. Nine (22%) of these patients developed adverse clinical outcomes requiring the following treatments: 9 (22.0%) ICU admissions, 5 (12.2%) mechanical ventilation, and 3 (7.3%) inhospital deaths. Counting the number of patients with more than 4 involved lobes, the sensitivity, specificity, positive predictive value, and negative predictive value for detection of adverse clinical outcome were 67%, 84%, 55% and 80%, respectively. Conclusion: Extensive involvement of both lungs (over 4 lobes) is related to ICU admission, mechanical ventilation, and inhospital death. Initial chest CT may help predict an adverse clinical outcome of patients with 2009 H1N1 influenza pneumonia.

Studies on the Use of Carboxymethylcellulose Sodium Salt Matrix for the Immobilization of Photobacterium phosphoreum (Photobacterium phosphoreum을 고정화하기 위한 Carboxymethylcellulose Sodium Salt [CMC] 담체의 이용성 연구)

  • 이용제;정성제;허문석;전억한
    • KSBB Journal
    • /
    • v.15 no.1
    • /
    • pp.49-54
    • /
    • 2000
  • Bioluminescence of Photobacterium phosphoreum has been used for the detection of pollutants in the environment. Immobilization method was used to maintain the stability of bioluminescence of P. phosphoreum. The carboxymethylcellulose was investigated to find out whether it was suitable for the immobilization of P. phosphoreum as a matrix without disturbing the bioluminescence emission. A maintenance of bioluminescence was determined from the P. phosphoreum immobilized on the various concentrations of carboxymethylcellulose. A relatively high bioluminescence intensity was shown with immobilized cells on 1%(w/v) carboxymethylcellulose. The effect of carboxymethylcellulose concentrations on the sensitivity of Crcompounds including $Na_{2}CrO_{4}$, $K_{2}CrO_{4}$, $CrO_{3}$, CrK$(SO_4)_{2}$ and $CrCl_{3}$ to the bioluminescence intensity. The calculated $EC_{50}$ showed that the linear relations between such substances and bioluminesence intensity were established.

  • PDF

The Application of Octa-Substituted Metallophthalocyanine Langmuir-Blodgett films for $NO_2$ Measurement (수정진동자를 이용한 프탈로시아닌 LB박막의 $NO_2$ 감지 특성)

  • Kwon, H.J.;Lee, Y.J.;Chang, Y.K.;Kim, J.D.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.254-262
    • /
    • 1998
  • Multilayer Langmuir-Blodgett (LB) films coated on quartz crystal microbalance (QCM) of octa-substituted metallophhtalocyanines ($MPc(OEH)_8$, M = Cu, Co, and Sn) and dihydrogen phthalocyanines ($H_2Pc(OEH)_8$) were used to quantify $NO_2$ concentrations. They were exposed to various concentrations of $NO_2$ in dry $N_2$. Among the four phthalocyanines we tested, the metal-free $H_2Pc(OEH)_8$ was observed to be most sensitive to $NO_2$. However, its LB film showed a partially irreversible behavior, that is part of the frequency change due to $NO_2$ adsorption could not be recovered even after purging with pure $N_2$ gas for an extended period. Examining the spectra of NMR and FTIR revealed fact that the irreversible portion of frequency change was due to ether groups in the linkage between side chains and the Pc unit. In order to remove the effect of such initial deactivation, on $NO_2$ quantification experiment, a freshly fabricated LB film was treated at a high concentration of $NO_2$ so that the ether sites were saturated. A pretreated LB film showed a reproducible performance for repeated uses. The $CuPc(OEH)_8$ LB film showed a satisfactory sensing performance down to as low as 4 ppm. For the $H_2Pc(OEH)_8$ LB film, the lower detection limit was found to be 35ppb of $NO_2$. In order to make the experimental condition more realistic, the carrier gas, dry nitrogen, was replaced by air. It was observed that the presence of oxygen, a weak electron acceptor, reduced the sensitivity and thus increased the sensing limit to hundreds of ppb. Results of experiments with moisture added showed that the interference of moisture was quite severe.

  • PDF

Characteristics of Constructed SPR (Surface Plasmon Resonance) Sensor System for the Detection of Salmonella and hIgG Antigen-Antibody Reaction. (살모넬라와 면역글로블린(hIgG)의 항원-항체반응 감지를 위한 표면 플라즈몬 공명형 센서시스템의 특성)

  • Um, N.S.;Koh, K.N.;Hahm, S.H.;Kim, J.H.;Lee, S.H.;Kang, S.W.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.263-270
    • /
    • 1998
  • Surface Plasmon Resonance (SPR) sensor system, has rapid response and high sensitivity, can be applicable for detecting reaction times of many biospecific interactions. A SPR sensor system was constructed to detect the antigen-antibody reactions of salmonella and hIgG (human immunoglobulin G). Sensor chips made of gold thin film were used for detecting biological bindings of antigen and antibody reactions. The antigen and antibody reactions for salmonella and hIgG were carried out with various time intervals to observed characteristics of these reactions using SPR sensor system. The resonance angle shift changes were clearly observed at the time of salmonella or hIgG antibody injection into sample cell since each antibody was self-assembled on gold chip surface of the sensor. It was found that the antibodies of salmonella and hIgG reacted with its sensor chip surface in 10 minutes and 60 minutes respectively. And the antigens of both salmonella and hIgG were bound to its antibody within 1 minute.

  • PDF

Sensing Characteristics of $SnO_{2}$ type CO sensors for combustion exhaust gases monitoring (연소배가스 모니터링을 위한 $SnO_{2}$계 CO센서의 검지특성)

  • Kim, I.J.;Han, S.D.;Lim, H.J.;Son, Y.M.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.369-375
    • /
    • 1997
  • $V_{2}O_{5}/ThO_{2}/Pd$-doped $SnO_{2}$ sensor has a good selectivity and stability to CO at high sensor temperature of about $500^{\circ}C$, and shows rapid response. In particular, many kinds of interference gases, such as $NO_{x}$, $C_{3}H_{8}$, $CH_{4}$ and $SO_{2}$ have been found to give only a slight influence on the sensor selectivity to CO gas sensitivity by doped $V_{2}O_{5}$ (3.0 wt.%). For the sensor we used well-known thick film technological route with $V_{2}O_{5}$(3.0 wt.%), Pd(1.0 wt.%) and $ThO_{2}$(l.5 wt.%) as catalytic materials. In the case of mixed $NO_{x}$-CO gases, as combustion exhaust gas, only CO detection by $SnO_{2}$ type semiconductor sensor is generally very difficult because of $NO_{x}$ interference. The developed sensors can use to measure the exhausting gas of the automobile or the boiler for the Air-to-Fuel ratio control.

  • PDF