• Title/Summary/Keyword: Detection sensitivity

Search Result 2,447, Processing Time 0.031 seconds

Determination of Six Sweeteners in Children's Favorite Foods by HPLC-MS/MS (HPLC-MS/MS를 이용한 어린이 기호식품중의 감미료 분석)

  • Kim, Il-Young;Du, Ok-Ju;Lee, Sung-Dck;Park, Young-He;Kim, Mi-Sun;Bea, Chung-Ho;Chae, Young-Zoo
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.2
    • /
    • pp.118-121
    • /
    • 2010
  • A HPLC-MS/MS method was developed for simultaneous determination of six sweeteners (acesulfame-K, cyclamate, saccharin, sucralose, stevioside, aspartame) in children's favorite foods. The procedure involves an extraction of the six sweeteners with 50% methanol solution, sample clean-up using the Carrez clearing reagent and filtering with cartridge filter. The HPLC separation was performed on a Hypersil Gold (150 mm ${\times}$ 2.1 mm 5 um) column using the water/acetonitrile mobile phase (95:5). Mass spectrometric analysis was carried out using the TSQ Quantum Ultra operated in negative and positive ESI/SRM. With this method, good linear relationship, sensitivity and reproducibility were obtained. The spike recoveries of six sweeteners for 2 kinds of foods spiked into 0.4 mg/ kg ranged from 87.4 to 114.7%. The detection limits were above 0.02 mg/kg. The method has been applied to determination of six sweeteners in children's favorite foods.

The Determination of Perfluorooctane sulfonate in Food Packing Materials by HPLC-MS/MS (식품 포장재 중의 퍼플루오르옥탄설포네이트 분석)

  • Kim, Il-Young;Kim, Au-Kyoung;Jung, Bo-Kyoung;Shin, Young;Kim, Ji-Young;Kim, Jung-Han;Chae, Young-Zoo
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.4
    • /
    • pp.376-380
    • /
    • 2013
  • Determination of PFOS in instant food packing materials by LC-MS/MS was developed. The procedure involves an extraction of the Food Packing Materials with 100% methanol soxcelet extraction method. The LC separation was performed by Hypersil Gold ($150mm{\times}2.1mm$ 5 um) with mobile phases of 2 mM amoniumacetate solution and acetonitrile. The Mass spectral acquisition was done in negative ESI/SRM using the TSQ Quantum Ultra. With this method, good linear relationship, sensitivity and reproducibility were obtained. The rate of recoveries of PFOS from paper material spiked with 1.0 ug/L were 99.84%, respectively. The limit of quantitation and limit of detection were below 0.03 ug/L and 0.009 ug/L. The method had been applied to determination of PFOS in instant food packing materials.

Improved Vapor Recognition in Electronic Nose (E-Nose) System by Using the Time-Profile of Sensor Array Response (센서 응답의 Time-Profile 을 이용한 전자 후각 (E-Nose) 시스템의 Vapor 인식 성능 향상)

  • Yoon Seok, Yang
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.329-334
    • /
    • 2004
  • The electronic nose (E-nose) recently finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. The odor recognition performance of E-nose can be improved by manipulating the sensor array responses of vapors in time-profile forms. The different chemical interactions between the sensor materials and the volatile organic compounds (VOC's) leave unique marks in the signal profiles giving more information than collection of the conventional piecemal features, i.e., maximum sensitivity, signal slopes, rising time. In this study, to use them in vapor recognition task conveniently, a novel time-profile method was proposed, which is adopted from digital image pattern matching. The degrees of matching between 8 different vapors were evaluated by using the proposed method. The test vapors are measured by the silicon-based gas sensor array with 16 CB-polymer composites installed in membrane structure. The results by the proposed method showed clear discrimination of vapor species than by the conventional method.

Detection and Typing of Human Papillomavirus in Cutaneous Common Warts by Multiplex Polymerase Chain Reaction (Multiplex PCR 기법을 이용한 보통사마귀 내 인유두종바이러스 검출 및 분류)

  • Choi, Soon-Yong;Lim, Jong-Ho;Kim, Eun-Jung;Kim, Hei-Sung;Kim, Beom-Joon;Kang, Hoon;Park, Young-Min
    • Journal of Life Science
    • /
    • v.21 no.7
    • /
    • pp.947-952
    • /
    • 2011
  • A number of epidemiological studies have identified human papillomavirus (HPV) types 1, 2, 3, 4, 7, 10, 27, 57, and 65 in cutaneous common warts. However, identification of the HPV subtype by conventional polymerase chain reaction (PCR) is time consuming with its multi-step laboratory process. In this study, we aim to develop a specific one-step multiplex polymerase chain reaction method which capably identifies six different HPV genotypes related to common warts. By HPV DNA sequence analysis, 6 pairs of specific primers were designed from the intergenic regions of genes L1 to E6, and from genes E2 to L2. DNA sequence analysis with the L1 gene sequence of the sample was performed to measure the specificity of multiplex PCR. HPV-1, -2, -3, -4, -27, and -57 were identified without cross amplification in 109 out of 129 samples. The sensitivity and specificity of our set of primers in detecting HPV were 85% and 99.5%, respectively. For the 20 samples where HPV type was not identifiable by our batch of primer sets, multiplex PCR with an additional set of HPV primers was done, where 7 were found positive for HPV-7 or -65. Our results demonstrate that the newly designed multiplex PCR can rapidly detect the specific HPV subtype involved in common warts with high accuracy.

ACCURACY OF PREOPERATIVE ASSESSMENTS FOR CERVICAL LYMPH NODE METASTASIS IN ORAL CANCER (구강암 경부임파절 전이에 대한 술전 평가의 정확성)

  • Lee, Jae-Jun;Nam, Woong;Cha, In-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.2
    • /
    • pp.151-156
    • /
    • 2006
  • Purpose : The aim of this study was to determine the accuracy of clinical and radiologic assessments in detecting positive cervical lymph nodes in oral cancer. Materials and Methods : We had reviewed the preoperative clinical, radiologic and postoperative histopathologic reports of 46 patients who had been diagnosed as oral cancer and underwent surgical excision combined with neck dissection (52 sides of neck) in the Department of Oral and Maxillofacial Surgery, College of Dentistry, Yonsei University from the July 1, 1992 to the April 30, 1999. Results : The results were as follows 1. The male to female ratio was 4.38 : 1 and the mean age was 57. 2. Sensitivity values for the preoperative assessment of cervical lymph node metastasis in oral cancer were 62.5 % in clinical examination and 50.0 % in radiologic assessments. Specificity values were 77.8 % in clinical examination and 94.4 % in radiologic assessments. 3. False positive values were 44.4 % in clinical examination and 20.0 % in radiologic assessments. False negative values were 17.6 % in clinical and 19.0% in radiologic assessments. 4. Overall efficiency values were 73.1 % in clinical examination and 80.8 % in radiologic assessments. Summary : There were some limits on the accuracy of clinical and radiologic assessments in the preoperative detection of the cervical lymph nodes in oral cancer. To improve the accuracy, it is important to communicate between clinician and radiologist, and adjunctive diagnostic measures, ultrasound and fine needle aspiration cytology, were helpful increasing the overall efficiency. In the high risk sites (oral tongue and floor of the mouth) the false negative value is higher and the overall efficiency in radiologic evaluation is lower than those of the low risk sites (gingiva and alveolar ridge, retromolar trigone and buccal mucosa ). The elective neck dissection should be considered in the high risk sites.

Procalcitonin in 2009 H1N1 Influenza Pneumonia: Role in Differentiating from Bacterial Pneumonia (2009 H1N1 인플루엔자 폐렴에서 Procalcitonin의 유용성: 세균성 폐렴과의 감별 역할)

  • Ahn, Shin;Kim, Won-Young;Yoon, Ji-Young;Sohn, Chang-Hwan;Seo, Dong-Woo;Kim, Sung-Han;Hong, Sang-Bum;Lim, Chae-Man;Koh, Youn-Suck;Kim, Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.4
    • /
    • pp.205-211
    • /
    • 2010
  • Background: Procalcitonin is a well known marker in infection that plays a role in distinguishing between bacterial and viral infections in screening. The aim of the present study was to evaluate the role of procalcitonin in differentiating between 2009 H1N1 influenza pneumonia and community acquired pneumonia of bacterial origin, or mixed bacterial origin and 2009 H1N1 influenza infection. Methods: A retrospective observational study was performed over the 6-month winter period during the 2009 H1N1 influenza pandemic. Ninety-six patient-subjects were enrolled, all of whom had been diagnosed with community acquired pneumonia in emergency department during the study period. On admission, laboratory studies were performed, which included 2009 H1N1 influenza real-time polymerase chain reaction of nasal secretions and procalcitonin on serum; the laboratory values were compared between the study groups. Receiver operating characteristic curve analyses were performed on the resulting data. Results: Compared to those with bacterial or mixed infections (n=62) and bacterial pneumonia with confirmed organisms (n=30), patients with 2009 H1N1 pneumonia (n=34) were significantly more likely to have low procalcitonin levels (p=0.008, 0.001). Using cutoff of value >0.3 ng/mL, the sensitivity and specificity of procalcitonin for detection of patients with confirmed bacterial pneumonia were 76.2% and 60.6%, respectively. A significant difference in procalcitonin was found between 2009 H1N1 pneumonia and pneumonia caused by mixed influenza viral and bacterial infections (0.15 [0.05~0.84] vs. 10.3 [0.05~22.87] ng/mL, p=0.045). Conclusion: Serum procalcitonin measurement may assist in the discrimination between pneumonia of bacterial and of 2009 H1N1 influenza origin. High values of procalcitonin suggest that bacterial infection or mixed infection of bacteria and 2009 H1N1 influenza is more likely.

Meat Species Identification using Loop-mediated Isothermal Amplification Assay Targeting Species-specific Mitochondrial DNA

  • Cho, Ae-Ri;Dong, Hee-Jin;Cho, Seongbeom
    • Food Science of Animal Resources
    • /
    • v.34 no.6
    • /
    • pp.799-807
    • /
    • 2014
  • Meat source fraud and adulteration scandals have led to consumer demands for accurate meat identification methods. Nucleotide amplification assays have been proposed as an alternative method to protein-based assays for meat identification. In this study, we designed Loop-mediated isothermal amplification (LAMP) assays targeting species-specific mitochondrial DNA to identify and discriminate eight meat species; cattle, pig, horse, goat, sheep, chicken, duck, and turkey. The LAMP primer sets were designed and the target genes were discriminated according to their unique annealing temperature generated by annealing curve analysis. Their unique annealing temperatures were found to be $85.56{\pm}0.07^{\circ}C$ for cattle, $84.96{\pm}0.08^{\circ}C$ for pig, and $85.99{\pm}0.05^{\circ}C$ for horse in the BSE-LAMP set (Bos taurus, Sus scrofa domesticus and Equus caballus); $84.91{\pm}0.11^{\circ}C$ for goat and $83.90{\pm}0.11^{\circ}C$ for sheep in the CO-LAMP set (Capra hircus and Ovis aries); and $86.31{\pm}0.23^{\circ}C$ for chicken, $88.66{\pm}0.12^{\circ}C$ for duck, and $84.49{\pm}0.08^{\circ}C$ for turkey in the GAM-LAMP set (Gallus gallus, Anas platyrhynchos and Meleagris gallopavo). No cross-reactivity was observed in each set. The limits of detection (LODs) of the LAMP assays in raw and cooked meat were determined from $10pg/{\mu}L$ to $100fg/{\mu}L$ levels, and LODs in raw and cooked meat admixtures were determined from 0.01% to 0.0001% levels. The assays were performed within 30 min and showed greater sensitivity than that of the PCR assays. These novel LAMP assays provide a simple, rapid, accurate, and sensitive technology for discrimination of eight meat species.

Development and comparison of convenient residue analysis for avermectin B1 in apple and soil (사과 및 토양중 avermectin B1의 간편한 잔류 분석법 개발과 비교)

  • Lee, Kang-Bong;Kim, Yong-Du;Shim, Jae-Han;Suh, Yong-Tack
    • Applied Biological Chemistry
    • /
    • v.35 no.2
    • /
    • pp.115-121
    • /
    • 1992
  • Avermectin B1(abamectin) is an very effective acaricide/insecticide. Because it is applied at low rates, the resultant residue level would be quite low and this requires highly sensitive analytical method. In this study, three analytical methods for avermectin $B1_a$, were compared in view of detectability and sensitivity. The first analytical method was an HPLC method employing the fluorescence detection of avermectin. The second analytical technique to quantitate avermectin $B1_a$, and its photodegradative delta 8,9-isomer employed trifluoroacetic anhydride and 1-methylimidazole in DMF. The new method was the modification of trifluorescence method. The average recoveries of avermectin $B1_a$ for the concentration range from 1 and 10 ng/g in whole apple fruit by fluorescence method were 90.3% and 88.2% respectively. In trifluorescence method, the recoveries of the avermectin $B1_a$ and delta 8,9-isomer were 100.7% and 94.7% in concentration from 5 ng/g and 25 ng/g. The average recoveries of 5 ng and 25 ng/g in the newly modified method were 95.0, 99.0. 96.0, 92.8% in whole apple and soil respectively.

  • PDF

Simultaneous Determination of Pesticides in Water Using a GC/MS Coupled with Micro Extraction by Packed Sorbent (MEPS-GC/MS를 이용한 농약류 동시 수질분석)

  • Lee, Ki-chang;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.5
    • /
    • pp.262-268
    • /
    • 2015
  • This study established an analytical method to simultaneously determine six organophosphorous pesticides [methyldemetone-S, diazinon, fenitrothion, parathion, phentoate, and O-ethyl O-(4-nitrophenyl) phenylphosphonothioate (EPN)] and carbaryl in water using a gas chromatography/mass spectrometry (GC/MS) system coupled with on-line micro extraction by packed sorbent (MEPS) and programmed temperature vaporizer (PTV) injector. Polystyrene divinylbenzene (PDVB) was used as a sorbent of MEPS. The effects of elution solvents, pH, elution volume and draw-eject cycles of samples on sample pretreatment process were investigated. Also, quality assurance and quality control (QA/QC) and the recovery of the pesticides in environmental samples were evaluated. The elution was performed using $30{\mu}L$ of a mixed solvent (acetone : dichloromethane = 80 : 20 (v/v)). Sample pretreatment processes were optimized with seven cycles of draw-eject of sample (1 mL) spiking an internal standard and sulfuric acid. At lower pH, the analytical sensitivity of diazinon decreased, but that of carbaryl increased. The method detection limit and the limit of quantification for this method were 0.02~0.18 and $0.08{\sim}0.59{\mu}g/L$, respectively. The method precision and accuracy were 1.5~11.5% and 83.3~129.8%, respectively, at concentrations of $0.5{\sim}5.0{\mu}g/L$. The recovery rates for all the pesticides except carbaryl in various environmental samples ranged 75.7~129.3%. The recovery rate of carbaryl in effluent sample was over 200% whereas carbaryl in drinking water, groundwater, and river water were in the acceptable range.

Predictors of Protective Factors for Depression in Adolescent using Decision Making Tree Analysis (의사결정나무분석을 이용한 청소년 우울의 보호요인 예측모형)

  • Kim, Bo-Young
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.5
    • /
    • pp.375-385
    • /
    • 2015
  • The study is to develop specific strategies to prevent adolescents' depression, early detection and intervention services. This study was a descriptive research study with the purpose of predictors of protective factors for depression in adolescent using decision making tree analysis. The subjects for the study were 485 student in G city. This study collected data between September 23, 2013 and September 26, 2013 and analyzed them with frequency analysis, percentage, the mean and standard deviation, ${\chi}^2$-test, t-test, and a decision-making tree by using SPSS 20.0 program. From the data analysis, the predictive model for protective factors related to depression in adolescent with 4 pathways, 12 nodes. The common predicting variables of depression in adolescent were characteristics, family cohesion, parent adolescent communication, peer communication. The specialty of training data and test data was 76.0% and 65.4%. The sensitivity of training data was 78.2% and 63.7%. As for the classification accuracy, training data and test data explained 70.1% and 69.7%. Parent adolescent communication and peer communication to decrease depression of Korean middle and high school students are necessary. This study should contribute as baseline data for intervention strategies and planning ability of depression prevention in adolescents.