• Title/Summary/Keyword: Detection potential

검색결과 1,631건 처리시간 0.027초

반주기 변조된 송신파형과 대지전위 측정을 이용한 지중 케이블 누전 고장점 탐지 시스템 (Electric Leakage Point Detection System of Underground Power Cable Using Half-period Modulated Transmission Waveform and Earth Electric Potential Measurement)

  • 전정채;유재근
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2113-2118
    • /
    • 2016
  • The precise detection of electric leakage point of underground power cable is very important to reduce cost and time of maintenance and prevent electric shock accident through expedite repair of electric leakage point. This paper proposes a electric leakage point detection system underground power cable using of half-period modulated transmission waveform and earth electric potential measurement. The developed system is composed of transmitter to generate the wanted pulse waveform, receiver to measure and display earth electric potential by the transmitted pulse in electric leakage point and PC Software program to display of GPS coordinate on detection cable line. The performance of the electric leakage point detection system was tested in the constructed underground cable leakage detection test bed. The test results on signal generation voltage precision of signal transmitter, mean detection earth voltage, mean detection leakage current and electric leakage point detection error showed the developed system can be used in electric leakage point detection underground power cable.

가스절연개폐장치의 전위감지 시스템에 대한 연구 (A study on the Potential Detection System of Gas Insulated Switchgear)

  • 최승길;백승국;김광호;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2284-2286
    • /
    • 1999
  • This paper describes the development of potential detection system in 22.9kV gas insulated switchgear. This system composed with main system and LPS can detect the source voltage by capacitive potential division which is accomplished by inserting signal electrode between main electrode and earthed metal enclosure of the switchgear. The appropriate position of signal electrode is achieved by numerical analysis using finite element method. The developed potential detection system is verified by several tests such as voltage test, swc test and others and by applicaion at site. From the results, it is concluded that potential detection system is very reliable and available to operate the switchgear safely.

  • PDF

브리지 회로 개념이 적용된 전기 전위법을 이용한 탄소섬유복합재료의 균열검출 (Crack Detection of Carbon Fiber Reinforced Composites by Electric Potential Method with Bridge Circuit Concept)

  • 황희윤
    • Composites Research
    • /
    • 제22권1호
    • /
    • pp.9-14
    • /
    • 2009
  • 본 논문에서는 탄소섬유 복합재료의 균열의 위치 및 성장을 감지하기 위하여 브리지 회로 개념이 적용된 전기 전위법을 제안하였다. 중앙 관통 균열을 가진 복합재료 박판 시험편에 두 쌍의 전극을 생성하였으며, 브리지 회로 개념을 적용하여 한 쌍의 전극에 외부 전압을 인가하고 다른 한 쌍의 전극으로부터 출력 전압 변화를 관찰하였다. 실험과 유한요소해석을 통하여 전극의 크기와 간격, 균열의 위치와 크기 및 성장 방향의 영향을 고찰하였다. 검출 가능한 균열의 크기는 전극의 크기 보다는 전극의 간격에 의한 영향이 더 컸으며, 전극의 크기와 간격이 작을수록 균열의 검출 능력이 우수하였다. 또한, 균열 크기가 증가할 수록, 입력 전극과 가까울수록 출력 전압의 변화가 큼을 관찰할 수 있었다.

Optimization of Wave Forms for Pulsed Amperometric Detection of Cyanide and Sulfide with Silver-Working Electrode

  • 박성우;홍성욱;유재훈
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권2호
    • /
    • pp.143-146
    • /
    • 1996
  • A continuous potential pulse is applied to a silver-working electrode on a pulsed amperometric detector (PAD) for detection of free cyanide and sulfide. The moving phase is 0.1 M sodium hydroxide, 0.5 M sodium acetate and 5% (v/v) ethylenediamine mixture, and the flow rate is 0.7 mL/min. Optimized pulse conditions include a -200 mV (vs. Ag/AgCl reference electrode) detection potential(Ed) for 60 msec and 50 mV cleaning potential (Ec) for 120 msec. The silver working electrode surface is not poisoned by cyanide or sulfide, and the PAD maintains long-term stability without loss of sensitivity and reproducibility at these pulse conditions. The detection limit of cyanide and sulfide separated by ion chromatography using an anion exchange column is 0.1 ppm and 0.05 ppm, respectively.

Detection of Delamination Crack for Polymer Matrix Composites with Carbon Fiber by Electric Potential Method

  • Shin, Soon-Gi
    • 한국재료학회지
    • /
    • 제23권2호
    • /
    • pp.149-153
    • /
    • 2013
  • Delamination crack detection is very important for improving the structural reliability of laminated composite structures. This requires real-time delamination detection technologies. For composite laminates that are reinforced with carbon fiber, an electrical potential method uses carbon fiber for reinforcements and sensors at the same time. The use of carbon fiber for sensors does not need to consider the strength reduction of smart structures induced by imbedding sensors into the structures. With carbon fiber reinforced (CF/) epoxy matrix composites, it had been proved that the delamination crack was detected experimentally. In the present study, therefore, similar experiments were conducted to prove the applicability of the method for delamination crack detection of CF/polyetherethereketone matrix composite laminates. Mode I and mode II delamination tests with artificial cracks were conducted, and three point bending tests without artificial cracks were conducted. This study experimentally proves the applicability of the method for detection of delamination cracks. CF/polyetherethereketone material has strong electric resistance anisotropy. For CF/polyetherethereketone matrix composites, a carbon fiber network is constructed, and the network is broken by propagation of delamination cracks. This causes a change in the electric resistance of CF/polyetherethereketone matrix composites. Using three point bending specimens, delamination cracks generated without artificial initial cracks is proved to be detectable using the electric potential method: This method successfully detected delamination cracks.

A dynamic procedure for defection detection and prevention based on SOM and a Markov chain

  • Kim, Young-ae;Song, Hee-seok;Kim, Soung-hie
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2003년도 Proceeding
    • /
    • pp.141-148
    • /
    • 2003
  • Customer retention is a common concern for many industries and a critical issue for the survival in today's greatly compressed marketplace. Current customer retention models only focus on detection of potential defectors based on the likelihood of defection by using demographic and customer profile information. In this paper, we propose a dynamic procedure for defection detection and prevention using past and current customer behavior by utilizing SOM and Markov chain. The basic idea originates from the observation that a customer has a tendency to change his behavior (i.e. trim-out his usage volumes) before his eventual withdrawal. This gradual pulling out process offers the company the opportunity to detect the defection signals. With this approach, we have two significant benefits compared with existing defection detection studies. First, our procedure can predict when the potential defectors could withdraw and this feature helps to give marketing managers ample lead-time for preparing defection prevention plans. The second benefit is that our approach can provide a procedure for not only defection detection but also defection prevention, which could suggest the desirable behavior state for the next period so as to lower the likelihood of defection. We applied our dynamic procedure for defection detection and prevention to the online gaming industry. Our suggested procedure could predict potential defectors without deterioration of prediction accuracy compared to that of the MLP neural network and DT.

  • PDF

역삼각형 모양을 갖는 마이크로 채널에서의 전기역학적 흐름전위 검출 (Electrokinetic streaming potential detection in a triangular-shaped microchannel)

  • 조성식;박제균
    • 센서학회지
    • /
    • 제16권2호
    • /
    • pp.115-119
    • /
    • 2007
  • We report electrokinetic streaming potential detection in a microchannel. Streaming potential, one of the representative electrokinetic phenomena, becomes noticeable either when the channel size reduces or when the concentration of electrolyte reduces. We suggest a triangular-shaped microchannel to enhance streaming potential. The triangular-shaped microchannel shows better performance than the straight one in terms of streaming potential. Couple of possible methods to enhance streaming potential is also discussed. Moreover, this type of channel and phenomenon can be applied to biological sensor application and energy transduction.

콘크리트 수변구조물의 누수 탐지를 위한 변형된 전기비저항 탐사 연구 (Modified Electrical Resistivity Survey for Leakage Detection of a Waterside Concrete Barrage)

  • 이보미;오석훈;임은상
    • 지구물리와물리탐사
    • /
    • 제18권3호
    • /
    • pp.115-124
    • /
    • 2015
  • 수변 콘크리트 구조물의 누수 탐지를 위해 변형된 배열을 이용하여 전기비저항 탐사를 실시하였다. 전극을 수면에 설치하여 콘크리트 구조물에 대한 새로운 전기비저항 탐사 방식을 제안하였으며, 해석의 단순화를 위해 선형 전류 송신원을 전류전극으로 사용하였다. 마지막으로 전위차를 얻는 방법에 따라 변형된 3가지 전극 배열을 제안하였고, 동일열전위 배열(direct potential array), 평행열 전위 배열(parallel potential array), 횡단 전위 배열(cross potential array)로 명명하였다. 변형된 전기비저항 탐사법을 수치해석, 실내 모형실험, 현장탐사에 적용한 후 그 결과를 비교 분석하여 수변 콘크리트 구조물의 누수 탐지 기술로서의 적합성을 알아보았다. 비교 분석 결과 동일열 전위 배열, 평행열 전위 배열, 횡단전위 배열 모두 누수가 일어날 때, 누수지점에서 뚜렷한 전위차의 변화 양상을 보여 수변 콘크리트 구조물의 누수 탐지에 유용한 방법임을 확인하였다.

수변구조물의 누수 경로 탐지를 위한 변형된 전기비저항 탐사 및 자료 해석 (Modified Electrical Resistivity Survey and its Interpretation for Leakage Path Detection of Water Facilities)

  • 이보미;오석훈
    • 지구물리와물리탐사
    • /
    • 제19권4호
    • /
    • pp.200-211
    • /
    • 2016
  • 횡단 전위 배열(cross potential array)과 동일열 전위배열(direct potential array) 자료를 뒷받침하여 다양한 수변 구조물의 누수 경로 예측을 가능하게 하는 배열을 제시하고 이를 D-Lux array 라고 명명하였다. 또한 D-Lux array 자료를 색으로 가시화한 하나의 행렬로 정리하여 D-Lux view라고 제시하고 D-Lux view에서 관찰되는 저 전위차 이상대의 위치로 누수 구역의 위치를 해석하였다. D-Lux view의 보다 직관적인 해석을 위해서 D-Lux array 자료와 동일열 전위 배열 자료를 함께 사용하여 각 지점들 사이의 전위차 자료를 각 지점의 전위값으로 역산하고 이를 이용하여 등전위 분포도를 작성하였다. 등전위 분포도는 그래프나 D-Lux view에서 알 수 없었던 누수의 유입구, 유출구 뿐만 아니라 경로까지 예측 가능하게 하였다. 수조 실험과 수치 해석으로 예비 탐사를 실시한 후 현장 탐사로 콘크리트 보와 필 댐에 대한 적용이 이루어졌다. 그 결과, 콘크리트 보와 필 댐에 대해 누수 경로 탐지가 가능함을 확인하였다.

초고주파수 진동 감지를 위한 이온 질량기반 진동센서 (Ion-Based Micro Vibration Sensor for Ultra-High Frequency Vibration Detection)

  • 김광호;서영호
    • 대한기계학회논문집A
    • /
    • 제32권9호
    • /
    • pp.728-732
    • /
    • 2008
  • This paper presents ion-based micro vibration sensor for the ultra-high frequency vibration detection. Presented sensor uses the motion of anion and cation in an electrolyte. Electrolyte vibration sensors have the high shock survival characteristics and a simple read-out circuit because of the small mass and own charges of ions. Presented sensor measures the induced electric potential by the mechanical-electrical coupling. It consist of electrolyte chamber and detection electrode. Electrolyte chamber was fabricated by PDMS molding. Detection electrode was made of gold evaporation on pyrex glass. Size of electrolyte chamber was designed as $600{\times}600{\times}100um$. Detection electrode had 200nm-thick and 42um-gap. In the experimental study, 5.8M sodium Chloride (NaCl) solution was used as electrolyte in 36nl-chamber. Mechanical vibration was measured from 2kHz to 4MHz.