• 제목/요약/키워드: Detecting Material

검색결과 356건 처리시간 0.026초

박 센서 배열에 따른 154kV XLPE 케이블의 부분방전 검출 특성 연구 (Partial Discharge Quality Measurement improvement of XLPE Cable of 154kV by new method of FSA)

  • 신동훈;양종석;;임종천;황두현;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.158-159
    • /
    • 2006
  • The system measuring the Partial discharge(PD) is very essential to investigate the hazard defects in the insulation systems of the high voltage engineering. We included two parts in this discussion; The proposed method of Foil Sensor Array and the normally used method m the practice. Firstly, it will be shown the improved sensitivity of our proposed FSA sensor compare with the existing normal foil sensor. And then, the linearity of detecting sensitivities of various kinds of FSA sensors such as $2{\times}2$, $2{\times}4$, $3{\times}3$ etc. using in our experiments, was shown. From the obtained results, we can see that FSA sensor is more sensitivity than normal foil sensor and the linear increment property of FSA sensitivities.

  • PDF

고전압회전기 고정자권선 운전중 부분방전진단시스템의 현장적용사례 연구 (A Case Study of On-line PD Measuring System on the Stator Winding for High Voltage Rotating Machine)

  • 오봉근;강동식;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.109-109
    • /
    • 2010
  • On-line partial discharge(PD) diagnostic system is the most prominent systems to diagnose insulation condition for the high voltage rotating machines. Partial discharge measuring system(PDMS) series with ceramic coupler(PD detecting sensor) installed hydro generator and high voltage motor have been measured the PD data for many years. The trend of PD magnitude in the on-line PD system increased for some machines. These machines showed a same result in the conventional off-line PD test and PD magnitude decreased after stator winding insulation cleaning. This case study show that PDMS has been proved to be good results by comparing PD magnitude with on-line and off-line PD test and it is important to plan the maintenance project for the hydro generator stator winding because PD value was decreased after insulation cleaning.

  • PDF

PRAM을 위한 Si-doped Ge2Sb2Te5 박막의 상변화 특성 연구 (A Study on the Phase Change Characteristics of Si-doped Ge2Sb2Te5 Thin Films for PRAM)

  • 백승철;송기호;이현용
    • 한국전기전자재료학회논문지
    • /
    • 제23권4호
    • /
    • pp.261-266
    • /
    • 2010
  • In this paper, we report the changes of electrical, structural and optical characteristics in $Ge_2Sb_2Te_5$ thin films according to an increase of Si content. The Si-doped $Ge_2Sb_2Te_5$ thin films were prepared by rf-magnetron co-sputtering method. Isothermal annealing was carried out at $N_2$ atmosphere. The crystallization speed (v) of amorphous thin films was evaluated by detecting the reflection response signals using a nano-pulse scanner (wavelength = 658 nm) with illumination power of 1~17 mW and pulse duration of 10~460 ns. Structural phase changes were evaluated by XRD, and the optical transmittance was measured in the wavelength range of 300~3000 nm using UV-vis-NIR spectrophotometer. The sheet resistance (RS) of the thin films was measured using 4 point probe. Conclusivlely, the v-value decreased with an increase of Si content, while the RS-values of both crystalline and amorphous phases were increased. In particular, fcc-to-hexagonal transition was suppressed by the added Si atoms.

에피성장된 Fe/GaAs (001) 적층구조에서의 스핀 주입 및 검출 (Electrical spin injection and detection in epitaxially grown Fe/GaAs (001) hybrid structure)

  • 이태환;구현철;김경호;김형준;한석희;임상호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.357-357
    • /
    • 2008
  • 에피성장된 Fe/GaAs 적층구조에서의 스핀 주입 실험을 하였다. Fe와 GaAs 사이에 Schottky tunnel barrier를 형성시키기 위하여 높게 도핑된 GaAs 층을 channel 층 위에 성장하였다. 스핀전달에 의한 chemical potential 차이만을 검출하기 위해서 전압 측정 단자 사이에 전류 흐름이 포함되지 않는 non-local 측정방법을 사용하였다. 그 결과 두 강자성 전극이 반평행한 구간에서 dip이 나타나는 것을 확인할 수 있었다.

  • PDF

154 kV XLPE 전력케이블의 부분방전 측정을 위한 FSA의 적용 및 표준화 연구 (A Study on FSA Application and Standardization for Partial Discharge Measurement of 154 kV XLPE Cable)

  • 신동훈;;양종석;황두현;임종천;박노준;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제20권5호
    • /
    • pp.462-466
    • /
    • 2007
  • The measuring system of the Partial discharge(PD) is very essential to investigate the hazard defects in the insulation systems of the high voltage engineering. We will discussed this research which has included two parts. The proposed method of Foil Sensor Array(FSA) and the normally used method in the practice. Firstly, it will be shown the improved sensitivity of a FSA sensor, which is our aim, compare with the existing normal foil sensor. And then, the linearity of detecting sensitivities of various kinds of FSA sensors was shown. According to our experiments, we can see that FSA sensor is more sensitivity than normal foil sensor and the linear increment property of FSA sensitivities.

차량 내 탑승자 상태 인식용 적외선 센서의 제조 및 특성 (Fabrications and Characteristics of Infrared Sensor for Passenger Conditional Detection in Vehicle)

  • 이성현;남태운
    • 한국전기전자재료학회논문지
    • /
    • 제22권3호
    • /
    • pp.222-229
    • /
    • 2009
  • A noble infrared sensor was studied for passenger conditional detection in vehicle, This research relates to uncooled infrared sensors for detecting the presence, type and temperature of occupants in vehicle. It sense that the occupants purpose to control the smart airbag for safety in the case of adult or child and to control the automatic air conditioning for convenience. This paper described the design and the fabrication of microbolometers which were composed of 2 by 8 elements using the surface micromachining technology. The characteristics of the array were investigated in the spectral region of $8{\sim}12{\mu}m$. The fabricated detectors exhibited the thermal mass of $7.05{\times}10^{-9}\;J/K$, the thermal conductance of $1.03{\times}10^{-6}\;W/K$, the thermal time constant of 6.8 ms, the responsivity of $2.96{\times}10^4\;V/W$ and the detectivity of $1.01{\times}10^9\;cmHz^{1/2}/W$, at the chopper frequency of 10 Hz and the bias current of $4.4{\mu}A$. We could successfully detect the human body condition in the divided zone. As a results, we concluded that microbolometer optimized in this research could be useful for the application of passenger conditional detection in vehicle.

Pt/MoO$_3$가스센서의 수소 감지 특성 (H$_2$ Gas Sensing Properties of Pt/MoO$_3$ Gas Sensor)

  • 최용일;김창교;김진걸;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.118-122
    • /
    • 1996
  • 1wt% Pt/MoO$_3$ gas sensors for detecting H$_2$ gas were fabricated by the pressed pellet method and surface structures of Pt/MoO$_2$ were investigated by TEM and XRD. It was observed that as the calcination temperature is increased, the overlayers of MoO$_3$ on Pt are produced, but the Cl content in PtCl$\_$x/ are decreased. H$_2$ gas sensing properties in N$_2$ ambient and in air ambient were investigated, respectively, and Pt/MoO$_3$ had high sensitivity at low working temp ; 7.8% at 50$^{\circ}C$, 97.7% at 100$^{\circ}C$, 97.1% at 150$^{\circ}C$ when the specimens are treated at 400$^{\circ}C$, and 99.6% at 150$^{\circ}C$ when they are treated at 200$^{\circ}C$. It shows the development of a low-power type sensor is possible by using Pt/MoO$_3$.

  • PDF

초고압 전력케이블용 중간 접속부 내의 부분방전신호 검출을 위한 박전극 응용 (The Application of Al-foil Electrode for Detecting Partial Discharge Signal in Middle Joint Box of EHV Power Cable)

  • 이용성;양종경;양종석;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.142-144
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the Al-foil electrode sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied wi th both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we had used Al-Foi1 sensor on middle joint box of 154[kV] underground transmission power cable, and then analyzed reliability of calibration signal by using the Al-Foi1 electrode sensor of NJB. From above results, decrement properties measured highly. But incase of injecting calibration signal of 500[pC] after measuring signals in IJB, the S/N ratio had about 25[dB] acquisition.

  • PDF

Bethe's Small Hole Coupling을 이용한 유전체의 밀리미터파대 유전특성 평가방법에 관한연구 (A Study of the Estimation Method for the Dielectric Properties of Dielectrics in Millimeter Wave Range using Bethe's Small Hole Coupling)

  • 이홍열;전동석;한진우;이상석
    • 한국전기전자재료학회논문지
    • /
    • 제15권12호
    • /
    • pp.1085-1089
    • /
    • 2002
  • The circular cavity resonator which can measure the dielectric properties of dielectrics in the Ka-band(26.5GHz∼400Hz) frequency range was designed and fabricated. A structure of the resonator is divided into two equal parts of the length and the dielectric plate sample is placed between two halves. Exciting and detecting of the resonator is Performed by WR28 rectangular waveguides using Bethe's small hole coupling. The GaAs plate sample, whose performance is known to be 13 in millimeter wave range, was used for the verification of the performance of the fabricated circular cavity resonator In the measurement of GaAs single crystal using that resonator, the resonant frequency of the dominant TE$\sub$011/ mode, the permittivity and Q${\times}$f$\sub$0/ were measured as 26.69GHz, 12.9 and 124,000GHz, respectively.

포켈스센서를 이용한 코로나방전 발생시의 전계변화 측정에 관한 연구 (A possible non-contact measuring technique for the variation of the electric field due to corona discharge by use of Pockels sensor)

  • 마지훈;강원종;임윤석;최재옥;장용무;구자윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.189-192
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. This system is constructed by He-Ne laser, Mach-Zehnder interferometer with Pockels sensor, balanced photo receiver, data acquisition board and PC. The response characteristics of the developed proto type sensor are examined for AC and corona discharge.

  • PDF