• 제목/요약/키워드: Detail Components

검색결과 383건 처리시간 0.033초

Design and Implementation of a Low-Code/No-Code System

  • Hyun, Chang Young
    • International journal of advanced smart convergence
    • /
    • 제8권4호
    • /
    • pp.188-193
    • /
    • 2019
  • This paper is about environment-based low-code and no-code execution platform and execution method that combines hybrid and native apps. In detail, this paper describes the Low-Code/No-Code execution structure that combines the advantages of hybrid and native apps. It supports the iPhone and Android phones simultaneously, supports various templates, and avoids developer-oriented development methods based on the production process of coding-free apps and the produced apps play the role of Java virtual machine (VM). The Low-Code /No-Code (LCNC) development platform is a visual integrated development environment that allows non-technical developers to drag and drop application components to develop mobile or web applications. It provides the functions to manage dependencies that are packaged into small modules such as widgets and dynamically loads when needed, to apply model-view-controller (MVC) pattern, and to handle document object model (DOM). In the Low-Code/No-Code system, the widget calls the AppOS API provided by the UCMS platform to deliver the necessary requests to AppOS. The AppOS API provides authentication/authorization, online to offline (O2O), commerce, messaging, social publishing, and vision. It includes providing the functionality of vision.

인발공정에 의해 강소성 가공된 AA1070선재의 미세조직 및 기계적 특성 (Microstructure and Mechanical Properties of an AA1070 Wire Severely Deformed by Drawing Process)

  • 정대한;이성희
    • 한국재료학회지
    • /
    • 제30권6호
    • /
    • pp.308-314
    • /
    • 2020
  • A commercial AA1070 alloy for electrical wire is severely deformed by drawing process in which a rod with an initial diameter of 9mm into is reduced to a wire of 2mm diameter. The drawn AA1070 wire is then annealed at various temperatures from 200 to 450 ℃ for 2h. Changes in microstructure, mechanical properties and electrical properties of the specimens with annealing temperature are investigated in detail. The specimen begins partially to recrystallize at 250 ℃; above 300 ℃ it is covered with equiaxed recrystallized grains over all regions. Fiber textures of {110}<111> and {112}<111> components are mainly developed, and {110}<001> texture is partially developed as well. The tensile strength tends to decrease with annealing temperature due to the occurrence of recovery or/and recrystallization. On the other hand, the elongation of the annealed wire increases with the annealing temperature, and reaches a maximum value of 33.3 % at 300 ℃. Electric conductivity of the specimens increases with annealing temperature, and reaches a maximum value of 62.6 %IACS after annealing at 450 ℃. These results are discussed in comparison with those for the other aluminum alloy.

A Modified Single-Phase Transformerless Z-Source Photovoltaic Grid-Connected Inverter

  • Liu, Hongpeng;Liu, Guihua;Ran, Yan;Wang, Gaolin;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1217-1226
    • /
    • 2015
  • In a grid-connected photovoltaic (PV) system, the traditional Z-source inverter uses a low frequency transformer to ensure galvanic isolation between the grid and the PV system. In order to combine the advantages of both Z-source inverters and transformerless PV inverters, this paper presents a modified single-phase transformerless Z-source PV grid-connected inverter and a corresponding PWM strategy to eliminate the ground leakage current. By utilizing two reversed-biased diodes, the path for the leakage current is blocked during the shoot-through state. Meanwhile, by turning off an additional switch, the PV array is decoupled from the grid during the freewheeling state. In this paper, the operation principle, PWM strategy and common-mode (CM) characteristic of the modified transformerless Z-source inverter are illustrated. Furthermore, the influence of the junction capacitances of the power switches is analyzed in detail. The total losses of the main electrical components are evaluated and compared. Finally, a theoretical analysis is presented and corroborated by experimental results from a 1-kW laboratory prototype.

The effect of arch geometry on the structural behavior of masonry bridges

  • Altunisik, Ahmet C.;Kanbur, Burcu;Genc, Ali F.
    • Smart Structures and Systems
    • /
    • 제16권6호
    • /
    • pp.1069-1089
    • /
    • 2015
  • Arch bridges consist of some important components for structural behavior such as arches, sidewalls, filling materials and foundations. But, arches are the most important part for this type of bridges. For this reason, investigation of arch is come into prominence. In this paper, it is aimed to investigate the arch thickness effect on the structural behavior of masonry arch bridges. For this purpose, Goderni historical arch bridge which was located in Kulp town, Diyarbakir, Turkey and the bridge restoration process has still continued is selected as an application. The construction year of the bridge is not fully known, but the date is estimated to be the second half of the 19th century. The bridge has two arches with the 0.52 cm and 0.69 cm arch thickness, respectively. Finite element model of the bridge is constructed with ANSYS software to reflect the current situation using relievo drawings. Then the arch thickness is changed by increasing and decreasing respectively and finite element models are reconstructed. The structural responses of the bridge are obtained for all arch thickness under dead load and live load. Maximum displacements, maximum-minimum principal stresses and maximum-minimum elastic strains are given with detail using contours diagrams and compared with each other to determine the arch thickness effect. At the end of the study, it is seen that the maximum displacements, tensile stresses and strains have a decreasing trend, but compressive stress and strain have an increasing trend by the increasing of arch thickness.

소형 공정열교환기 시제품에 대한 탄소성 고온구조해석 (Elastic/Plastic High-temperature Structural Analysis on the Small Scale PHE Prototype)

  • 송기남;이형연;홍성덕;박홍윤
    • 한국압력기기공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.1-6
    • /
    • 2011
  • PHE(Process Heat Exchanger) is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR(Very High Temperature Reactor) to the chemical reaction that yields a large quantity of hydrogen. Korea Atomic Energy Research Institute established a small-scale gas loop for the performance test of components, which are used in the VHTR, and they manufactured a PHE prototype made of Hastelloy-X to be tested in the small-scale gas loop. Results from the elastic structural analysis on the PHE prototype were reported in the previous article. In order to investigate the macroscopic structural characteristics and behavior of the PHE prototype under the test condition of the small-scale gas loop far more in detail, elastic-plastic high-temperature structural-analysis of the PHE prototype was carried out in this study.

Mobile 제품 도장의 내한성(耐汗性) 가속 평가법 개발 (The study of accelerating method for Mobile Product with sweat resistance)

  • 박광영;임성균;차승규
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제6권3호
    • /
    • pp.205-212
    • /
    • 2006
  • The purpose of this article is about the accelerated product-reliability-test method of the changing colors of mobile products, which are majorly from the frequent touching of sweating fingers. Such problems of changing colors of mobile products have found mostly In metallic paint containing aluminum paste pigments. Also we found that the color of Al Paste is changed by human sweat. Therefore, the accelerated experimental method has been tested as follow: applying the various concentration of lactic acid, which is the changing color components from human sweat, and deeping the testing sample under temperature of $60^{\circ}C$ in dilutelactic acid with water. From the series of tests, the most optimum concentration of lacticacid has been obtained in 10wt% and the sample is observed to be almost same effect as natural changing of colors by human touching after the test. It has been also confirmed from the cross-sectional analysis. In detail, the testing sample has changed its color in 48hr by changing color effect of Alpaste with 10 wt% of lactic acid, and the digit of $\Delta$ E has measured 10.9 after the test.

  • PDF

FLUENT를 활용한 콘크리트 건식 저장용기 공기유로 내부 유동장 해석 (ANALYSIS ON FLOW FIELDS IN AIRFLOW PATH OF CONCRETE DRY STORAGE CASK USING FLUENT CODE)

  • 강경욱;김형진;조천형
    • 한국전산유체공학회지
    • /
    • 제21권2호
    • /
    • pp.47-53
    • /
    • 2016
  • This study investigated natural convection flow behavior in airflow path designed in concrete dry storage cask to remove the decay heat from spent nuclear fuels. Using FLUENT 16.1 code, thermal analysis for natural convection was carried out for three dimensional, 1/4 symmetry model under the normal condition that inlet ducts are 100% open. The maximum temperatures on other components except the fuel regions were satisfied with allowable values suggested in nuclear regulation-1536. From velocity and temperature distributions along the flow direction, the flow behavior in horizontal duct of air inlet and outlet duct, annular flow-path and bent pipe was delineated in detail. Theses results will be used as the theoretical background for the composing of airflow path for the designing of passive heat removal system by understanding the flow phenomena in airflow path.

조화상수를 이용한 조위 발생확률분포 분석 (Analysis on the Occurrence Probability Distribution of Tidal Levels using Harmonic Constants)

  • 정신택;조홍연;김정대;조범준
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1053-1057
    • /
    • 2005
  • The occurrence probability (OP) distributions of tide levels using harmonic constants of six tidal gauging stations in Korean coastal zone were estimated and analysed in detail. OP analysis using harmonic constants data of Incheon(Youldo), Mokpo, Yeosu, Pusan, Pohang and Sokcho was carried out and compared with the OP using hourly tidal elevation data which were served through the Internet Homepage by the National Ocean Research Institute. The tidal elevation data were divided by the AHHW (ALLW) value referenced to MSL in order to compare the OP patterns in a relative scale. The OP of the tidal elevation calculated using 38 harmonic tidal constituents relatively well agreed with those of hourly observed tidal elevation data. However, the OP results using four harmonic tidal constituents overestimate the occurrence probability at the peak points and underestimate at the tail-regions of the OP. Especially, the OP patterns of the Sokcho and Pohang tidal gauging stations on the East Sea show totally different patterns and the estimation method using four harmonic constants should be modified and application should be strictly limited on the East Sea areas. The OP patterns are considerably well generated in case of the OP generation using the additional two or three dominant tidal constituents,

  • PDF

Requirements Study of a High-Resolution Satellite Image Receiving, Processing and Archiving System

  • Hong, Min-Nyo;Kim, Tae-Jung;Kim, Tag-Gon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.19-24
    • /
    • 1999
  • This paper addresses a new project being carried out at Satellite Technology Research Center. The purpose of the project is to implement a system which receives, processes and stores 1m resolution satellite image transmitted at over 300Mbps down link data rates. In order to develop such a system, a system operational concept design and a requirements study were being carried out As a result of the operational concept design, system objectives, system context and system functions were defined. The system shall be operated according to the philosophy of maximum automation. rapid processing, reliability, integrity, cost effectiveness, and expandability. The system is divided into twelve independent processes and its behavior is modeled by operational scenario, which are combinations of independent processes. Process information and logs generated by the system shall be stored in databases and data received and generated be automatically archived and managed in a hierarchical storage device. The system shall have redundant components in order to be ready for recovering from sudden system failures. This paper will describe in detail the system operational concept design and the system requirements derived from the operational concept design.

  • PDF

다우비시 웨이브릿 변환의 상세계수 비율을 이용한 교류발전기의 내부고장 검출 및 고장종류 판별 (Internal Fault Detection and Fault Type Discrimination for AC Generator Using Detail Coefficient Ratio of Daubechies Wavelet Transform)

  • 박철원;신광철;신명철
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.136-141
    • /
    • 2009
  • An AC generator is an important components in producing a electric power and so it requires highly reliable protection relays to minimize the possibility of demage occurring under fault conditions. Conventionally, a DFT based RDR has been used for protecting the generator stator winding. However, when DFTs based on Fourier analysis are used, it has been pointed out that defects can occur during the process of transforming a time domain signal into a frequency domain one which can lead to loss of time domain information. This paper proposes the internal fault detection and fault type discrimination for the stator winding by applying the detailed coefficients by Daubechies Wavelet Transform to overcome the defects in the DFT process. For the case studies reported in the paper, a model system was established for the simulations utilizing the ATP, and this verified the effectiveness of the proposed technique through various off-line tests carried out on the collected data. The propose method is shown to be able to rapidly identify internal fault and did not operate a miss-operation for all the external fault tested.