• Title/Summary/Keyword: Design water level

Search Result 854, Processing Time 0.034 seconds

Numerical Analysis in Hydrograph Determination for Sluice Gate installed Levee (배수통문이 설치된 제방의 설계수위파형결정에 관한 수치해석)

  • Kim, Jin-Man;Choi, Bong-Hyuck;Oh, Eun-Ho;Cho, Won-Beom
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.4
    • /
    • pp.1-9
    • /
    • 2015
  • According to national regulations and its commentary, such as Rivers Design Criteria & Commentary (KWRA, 2009), Foundation Structure Guideline and its Commentary(MLTM, 2014 and KGS, 2009), the integrity evaluation of river levee includes slope stability evaluation of both riverside/protected low-land and piping stability evaluation with respect to foundation and levee body along with water level conditions. In this case the design hydro-graph can be the most important input factor for the integrity evaluation, however it is fact that the national regulations do not provide any proper determination methods regarding hydro-graph. The authors thus executed an integrity evaluation of sluice gate in levee by changing each hydro-graph factor, including rising ordinary water level, lasting flood water level, falling water level, and flood frequency, in order to suggest a determination method of reasonable hydro-graph. As a result, the authors suggested that at least over 57 hours of rising ordinary water level and over 53 hours of lasting flood water level should be considered for the design hydro-graph of sluice gate in levee at Mun-san-jae.

Design of Model Predictive Controller for Water Level control in the Steam Generator of a nuclear Power Plants (증기 발생기 수위제어를 위한 모델예측제어기 설계)

  • 손덕현;이창구
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.8
    • /
    • pp.376-383
    • /
    • 2001
  • Factors leading to poor control of the steam generator in a nuclear power plant are nonminimum phase characteristics, unreliable of flow measurements and nonlinear characteristics, which increase more at low power(below 20%) operation. And the study of problems for water level control in the steam generator is that design water level controller only power renge, not entire. This paper introduces a model predictive control(MPC) algorithm for solving poor control factors and quadratic programming(QP) for solving input constraints. Also presents the design method of stable model predictive controller in the entire power range. The simulation results show the efficiency of proposed MPC controller by comparing with PI controller, and effect of the design parameters.

  • PDF

An Experimental Study of Ground Water Source Two Well Type Geothermal Heat Pump System (지하수 열원 복수정 지열 열펌프 시스템의 성능에 관한 실험적 연구)

  • Lim, Hyo-Jae;Kwon, Jeong-Tae;Kim, Chang-Eob;Kong, Hyoung-Jin;Park, Seong-Koo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.8
    • /
    • pp.468-474
    • /
    • 2009
  • Ground water source heat pump system is the oldest one of the ground source heat pump systems. Despite of this, little formal design information has been available until recently. The important design parameters for open system are the identification of optimum ground water flow, heat exchanger selection and well pump. In this study, the capacity of 50 RT system of two well type ground water heat pump system was used. As a result, static water level was -7 m and the level during the heating operation was -32 m, cooling operation was -40 m. The initial static water level recovered within 48 hrs. The temperature of ground water is $15.6^{\circ}C$ for heating season and $16.2^{\circ}C$ for cooling season and does not depend on the outdoor temperature. Operation efficiency of the system shows that, COP 3.1 for heating and COP 4.2 for cooling.

Economical Design of Water Level Monitoring Network for Agricultural Water Quantification (농업용수 정량화를 위한 경제적 수위계측망 설계)

  • Kim, Sun Joo;Kwon, Hyung Joong;Kim, Il Jung;Kim, Phil Shik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.5
    • /
    • pp.19-28
    • /
    • 2016
  • This study was to design the optimal locations of the water level monitoring to quantify the agricultural water use in irrigation area supplied from an agricultural reservoir. In most of agricultural areas without TM/TC (Tele-Monitoring and Tele-Control) or monitoring network, irrigation water have been supplied on conventional experience and agricultural reservoir have been operated based on the operating simulation results by HOMWRS (Hydrological Operation Model for Water Resources System). Therefore, this study quantified the amount of agricultural water use in an irrigation area (Musu Reservoir, Jincheon-gun) by establishing water level monitoring network and analyzed the agricultural water saving effect. According to the evaluation of the economic values for water saving effect, the saving agricultural water of 1.7 million ton was analyzed to have economic values of 0.85 million won as water for living, and 1.78 million won as water for industrial use. It is identified to secure economic feasibility of the new water monitoring network by establishing one monitoring point in the entrance, irrigation area and endpoint through the economic analysis.

Reconsideration of evaluating design flood level at Imjin River estuary (임진강 하류 감조구간에서 홍수위 산정 재고)

  • Park, Chang Geun;Baek, Kyong Oh
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.9
    • /
    • pp.617-625
    • /
    • 2017
  • In this study, it was examined that a methodology for evaluating the design flood level reasonably at Imjin River estuary affected by the tide periodically. First of all, the change of the flood level was observed by performing unsteady simulation which can take into account the characteristics of the tidal rivers. And the variations of the flood level was analyzed by change of the Manning's roughness coefficient which is sensitive to the water level calculation. The results were compared with the design flood level at Imjin River estuary announced in the 2011 Imjin River Basic Plan Report. For reference, the design flood level reported in 2011 has been calculated by using a section of a huge riverbed dredging section as input data. From the simulation results, it was found that the flood level evaluated by this study was able to satisfy the freeboard of the levee without the riverbed dredging when the roughness coefficient was assigned to the same value as that of the Han river estuary in the calculation of the flood level, and the unsteady flow simulation was carried out to reflect on the tidal river.

Design of Fuzzy Logic System for the Steam Generator Water Level Control of Nuclear Power Plants (원전 증기발생기 수위제어를 위한 퍼지 논리 시스템 설계)

  • Song, Un-Ji;Kwan, Dae-Hwan;Zheng, Bin;Yoo, Seog-Hwan;Choi, Byung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.328-330
    • /
    • 2005
  • Most of the water level controllers of the actual plant are PID controllers. But they have limitations in appling for tracking the set point and getting rid of disturbances, so there are some defects to apply in the actual ground even though many research works represented the resolution to solve it. In this paper, we design a fuzzy logic system (FLS) for controlling the steam generator water level in nuclear power plants. Some computer simulations reveal similar performance with the conventional PID controller.

  • PDF

Studies on the flow stabilization around the turbine suction with utilizing the surface water overflow at small-hydraulic power plant (표층수의 월류를 통한 소수력빌전소 수차터빈측의 유동안정화 연구)

  • Lee, Sungmyung;Kim, Cheolhan;Yoo, Gunjong;Kim, Wonseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.165.2-165.2
    • /
    • 2011
  • Flow with suction to water turbine must be in stable state at small hydraulic power plant. But because of water level fluctuation and water gate effect according to irregular supply of cooling water, it would happen to produce bubble and vortex and finally lead to problems in power-plant system. With utilizing the concept design of double size gate, surface water overflowed the overhead of gate for stable flow at suction. We developed the overflow condition and analyzed the design factor with existed one such as water level(overflow amount) and overhead of water gate(overflow figure). Flow test and CFD simulation say that flow have stable state around suction and 20% of wave reduction effect at surface layer after surface water overflow.

  • PDF

A Study on the Amount of Supply Water Consumption by Entropy in APT (엔트로피에 의한 공동주택의 급수사용량에 관한 연구)

  • 안창환;공성훈;김종영
    • Journal of the Korean housing association
    • /
    • v.11 no.3
    • /
    • pp.125-136
    • /
    • 2000
  • The purpose of this study was to analyze water consumption in each apartment buildings influenced by several factors that are the income level of inhabitants, life style, the area apartments and climate. The automation of sanitary machines or facilities in recently built apartments has caused largely increases in amount of water consumption. Therefore, the design for water supply is very important for the maintenance of the optimum level or pressure of water supply. This study is based on the offer of basic data for improving the quality of water supply and employing the sanitary machines or sanitary facilities by analysis of amount increased of water consumption rapidly. Amount of water consumption data, the change in quality of entropy to the supply water pipe was analyzed and presented to indicate the necessary to basic materials for the design of an optimal water pipe.

  • PDF

Design of FMCW radar waveform for flow measurement (유량 측정을 위한 FMCW 레이다 파형 설계)

  • Lee, Changki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.1
    • /
    • pp.83-90
    • /
    • 2020
  • A commercial flow measurement radar sensor estimates a quantity of flowed water using surface flow rate. In this way, the amount of water flowing per unit time cannot be measured accurately because of using an estimation result and it can't response environmental changes. For more accurate flow measurements we need width of waterway, water level and distance that water moved per unit time. Commonly two sensors are used to measure water level and flow rate. In this paper, we propose a method to simultaneously measure the water level and surface flow velocity using a single FMCW radar sensor and design the transmission waveform. In order to verify the waveform design, received signal is modelled based on transmission waveform. In addition, we consider phenomenons and problems that may occur in signal processing.

Water Level Intelligent Controller Design of Power Plant Drum (발전기 드럼의 수위 지능 제어기 설계)

  • Hong, Hyun-Mun;Jeon, B.S.;Kim, J.G.;Kang, G.B.;Lee, B.S.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.415-417
    • /
    • 2005
  • In this paper, we propose a intelligent controller design method for the water level control of the power plant drum in the form of nonminimum phase system. The proposed method is based on T. Takagi and M. Sugeno's fuzzy model. And we illustrate the improved characteristics as the simulation results, comparing with the conventional the PID and LQ controller design method

  • PDF