• Title/Summary/Keyword: Design of Mix Proportion

Search Result 105, Processing Time 0.027 seconds

A Study on the Design Load of Artificial Soil Ground (인공지반의 설계하중 산정에 관한 연구)

  • Youn, Seong-Cheol;Kim, Tae-Gyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.2
    • /
    • pp.36-46
    • /
    • 2009
  • The objective of this study is to analyze the effect of artificial soil ground on a structure. When the artificial soil ground is planted, the technical factors to be considered will be the load for buildings and the growth of plants. There are no current studies of the effect of artificial soil ground on a structure and this study will analyze the load effects of artificial soil ground, which mixes both pearlite and natural soil on structures. The load affecting the structures due to artificial soil ground will be maximized when the artificial soil ground becomes saturated, and which would occur when the rainfall intensity exceeds the infiltration capacity of the artificial soil ground. In order to determine whether the artificial soil ground has reached saturation or not, a 10 years frequency and 10 minutes rainfall intensity which is used for in urban drain design, is utilized. The hydraulic conductivity of artificial soil and mixed soil has been changed depending on the proportion of the mix, It has a range of fluctuation in the degree of hardening, in particular, but does not exceed the 10 minutes rainfall intensity over 10 years frequency in the most cases. Therefore, it would be efficient to apply the saturated unit weight of artificial soil ground as the design load of a structure.

The Quality Characteristics of Curcuma longa L powder Sulgitteok (강황분말 설기떡의 품질 특성)

  • Lee, Myung-Ho;Jeon, Soon-Ju;Kim, Sun-Kyung;Park, Hyang-Suk;Choi, Young-Sim
    • Culinary science and hospitality research
    • /
    • v.17 no.5
    • /
    • pp.184-192
    • /
    • 2011
  • This study aims to provide preliminary data to popularize Sulgitteok with optimum mix proportion of Curcuma longa L. powder by conducting moisture content, color values, texture and quantitative descriptive evaluations on Sulgitteok with 0 to 2.4% of Curcuma longa L. powder. The chemical composition of Curcuma longa L. powder was $12.6{\pm}0.21%$ of moisture, $1.8{\pm}0.12%$ of protein, $1.0{\pm}0.00%$ of fat, $1.3{\pm}0.01%$ of ash, and that of rice flour was $11.7{\pm}0.17%$ of moisture, $7.6{\pm}0.32%$ of protein, $2.1{\pm}0.01%$ of fat, $1.6{\pm}0.01%$ of ash. As the content of Curcuma longa L. powder increased, L-values significantly decreased while a-value and b-value significantly increased. The hardness of the texture characteristics significantly increased with increasing the amount of Curcuma longa L. powder(p<0.05). As for gumminess, cohesiveness, and chewiness, there was no significant difference(p<0.05) depending on the amount of Curcuma longa L. powder. The quantitative descriptive analysis of the color, flavor, moistness and chewiness of Sulgitteok showed that one with 0.8% of Curcuma longa L. powder was evaluated the highest.

  • PDF

Effects of Feeding Extruded Soybean, Ground Canola Seed and Whole Cottonseed on Ruminal Fermentation, Performance and Milk Fatty Acid Profile in Early Lactation Dairy Cows

  • Chen, P.;Ji, P.;Li, Shengli
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.2
    • /
    • pp.204-213
    • /
    • 2008
  • Four ruminally cannulated Holstein cows averaging 43 days in milk (DIM) were used in a $4{\times}4$ Latin square to determine the effect of feeding extruded soybean, ground canola seed and whole cottonseed on ruminal fermentation and milk fatty acid profile. One hundred and twenty lactating Holstein cows, 58 (${\pm}31$) DIM, were assigned to four treatments in a completely randomized block design to study the effects of the three types of oilseeds on production parameters and milk fatty acid profile. The four diets were a control diet (CON) and three diets in which 10% extruded soybean (ESB), 5% ground canola seed (GCS) and 10% whole cottonseed (WCS) were included, respectively. Diets consisted of concentrate mix, corn silage and Chinese wild rye and were balanced to similar concentrations of CP, NDF and ADF. Ruminal fermentation results showed that ruminal fermentation parameters, dry matter intake and milk yield were not significantly affected by treatments. However, compared with the control, feeding cows with the three oilseed diets reduced C14:0 and C16:0 and elevated C18:0 and C18:1 concentrations in milk, and feeding ESB increased C18:2 and cis9, trans11 conjugated linoleic acid (CLA). Production results showed that feeding ESB tended to increase actual milk yield (30.85 kg/d vs. 29.29 kg/d) and significantly decreased milk fat percentage (3.53% vs. 4.06%) compared with CON. Milk protein (3.41%) and solid non-fat (13.27%) from cows fed WCS were significantly higher than from cows fed CON (3.24% and 12.63%, respectively). Milk urea N concentrations from cows fed the ESB (164.12 mg/L) and GCS (169.91 mg/L) were higher than cows fed CON (132.31 mg/L). However, intake of DM, 4% fat corrected milk, energy corrected milk, milk fat and protein yields, milk lactose percentage and yield, somatic cell count and body condition score were not affected by different treatments. The proportion of medium-chain fatty acid with 14 to 16 C units in milk was greatly decreased in cows fed ESB, GCS and WCS. Feeding ESB increased the concentration in milk of C18:1, C18:2, C18:3 and cis9, trans11-CLA content by 16.67%, 37.36%, 95.24%, 72.22%, respectively, feeding GCS improved C18:0 and C18:1 by 17.41% and 33.28%, respectively, and feeding WCS increased C18:0 by 31.01% compared with feeding CON. Both ruminal fermentation and production trial results indicated that supplementation of extruded soybean, ground canola seed and whole cottonseed could elevate the desirable poly- and monounsaturated fatty acid and decrease the medium chain fatty acid and saturated fatty acid content of milk fat without negative effects on ruminal fermentation and lactation performance.

Service Life Assessment and Restrain Methods of Carbonation Attack on PC Outer Wall of LNG Storage Tanks (탄산염해에 대한 LNG 저장탱크 PC 외부벽체의 수명평가 및 억제방안)

  • Lee, Seung-Rim;Song, Il-Hyun;Kim, Han Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.73-80
    • /
    • 2014
  • The objective of this paper is to assess the service life and retrain methods of specimens, which were subjected to carbonation attack, obtained from mix proportion of Sam-cheok LNG storage tank under construction. As the results, accelerated-carbonation penetration depths of 7, 28, 56 ages indicated 4.45, 9.19, 13.37mm, and even considering for cover depths of steel of LNG storage tank under real operation, it was enough. In addition, with carbonation velocity coefficient calculated by carbonation penetration depths, the service life to design cover depth(70, 80, 90, 100mm) of PC outer tank of LNG storage tank was 779, 1017, 1287, 1589 years and 466, 609, 771, 951 years, respectively, considering the $CO_2$ concentration in air which account for the 0.03% and 0.05%. Also, the restrain methods to carbonation attack were feasible through controlling the factors affecting the changes of hydration products such as $Ca(OH)_2$, ion composition in pore solution and matter mobility of organization structures within hardened concrete.

Comparison of Test Methods for Evaluation of Chloride Diffusion Coefficient in Concrete (콘크리트의 염소이온 확산계수 평가를 위한 시험방법 비교)

  • Lee, Chan-Young;Kim, Hong-Sam;Kim, Jin-Cheol;Cheong, Hai-Moon;Ahn, Tae-Song
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.581-584
    • /
    • 2008
  • Generally, durability of concrete structures under marine environment is grossly declined by detrimental ions such as chlorides, which penetrate concrete and was diffused to corrode reinforcing rod. Therefore, chloride diffusion properties in concrete are important for durability evaluation and design of concrete structure. For estimation of chloride diffusion coefficient in concrete, both evaluation methods are used for steady state and non-steady state derived from Fick's 1st and 2nd law, respectively. However, as it is very difficult to evaluate diffusion coefficient for non-steady state like service environment where concrete is actually exposed, indirect evaluation method by laboratory accelerated test is generally used. In this study, comparison of chloride diffusion behavior was investigated for fixed mix proportion and age of concrete using four accelerated test methods based on domestic and foreign standards. From test results, only relative comparison between concrete mixtures was possible using ASTM C 1202 test, and diffusion coefficient for steady state was estimated as low as 1/10 of that for non-steady state. In addition, diffusion coefficient estimated by immersion test was similar to result by NT build 492 test.

  • PDF