• 제목/요약/키워드: Design Unit

검색결과 5,081건 처리시간 0.036초

성능선도에 의한 다통로 판형열교환기의 간이설계법 (An easy-to-use design procedure for multipass plate heat exchangers based on the performance plots)

  • 유호선;이근휘;방보청
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.250-261
    • /
    • 1999
  • Based on a set of performance plots relating the design variables to the imposed conditions, an easy-to-use and versatile design procedure for chevron-type multipass plate heat exchangers is developed. In order for the present procedure to cover multipass with unequal passes and non-unity ratio of heat capacity rate, each stream number of transfer unit is adopted as the basic design variable instead of the exchanger number of transfer unit. It is found that there exists a unique relation between the stream and exchanger number of transfer units regardless of the chevron angle and the plate length. In addition, for a given value of the pressure drop the heat transfer area per unit mass flow rate can be expressed in terms of the stream number of transfer unit only. These two relationships in the form of simple plots constitute the framework of design. The sample results in comparison with the available data indicate that the present procedure includes the previous ones as a subset, and that every design method is affected essentially by the selection of specific correlations for the heat transfer coefficient and the friction factor.

  • PDF

지역성을 반영한 공동주거 평면디자인 개발을 위한 연구 -POE를 이용한 거주자 평가를 기초로 - (A Study on the Design of Apartment Housing Units Based on the Regional Characteristics)

  • 오찬옥
    • 한국실내디자인학회논문집
    • /
    • 제40호
    • /
    • pp.76-85
    • /
    • 2003
  • This study was intended to suggest the design alternatives of housing units which were developed on the basis of POE. The POE of the New Apartment Complex in Gimhae was carried out and on the basis of the results of this POE, the design alternatives of housing units were developed. The subjects were 372 housewives who live in the apartment houses sized 60m2 to 85m2 in Gimhae. They answered about the living characteristics related to house, the degree of saisfaction with their housing unit plans, and the needs for housing unit plan. The major problems in current housing unit were the lack of storage space and the small size of living room and children's bedrooms. Many residents wanted to live in the housing unit which have three bedrooms and some of them wanted two bedrooms. Also, they wanted to enlarge living room and instead of that, to reduce master bedroom. In addition to these, the residents had diverse housing needs. On the basis of these results, housing alternatives which are flexible and optionable were suggested.

AutoCAD를 이용한 자동차용 헤밍 유닛의 자동작도 프로그램 개발 (Development of Automatic Drawing Program for Hemming Unit by AutoCAD)

  • 김동직;송윤준;정훈;김영빈;한영호
    • 소성∙가공
    • /
    • 제16권3호
    • /
    • pp.163-171
    • /
    • 2007
  • Due to the complicated character of the hemming process for automobile panels, it is very difficult to setup a consistent and reliable die design guide rule that require subtle decision of experienced experts and multiple trials during hemming die design and making. In this paper an automatic die design system of hemming units is pursued by presenting some algorithms, in which geometric data and constraints of the hemming units were converted to formula. The geometries and kinematics of all part for two kinds of hemming units, 2-link type and 4-link type were analysed kinematically to build the design algorithm. The algorithms were verified by automatic drawing used AutoCAD VBA program in example for the hemming unit design of a bonnet.

열해석을 이용한 위성 광학탑재체 냉각 장치의 히터설계 (Heater Design of a Cooling Unit for a Satellite Electro-Optical Payload using a Thermal Analysis)

  • 김희경;장수영;최석원
    • 항공우주기술
    • /
    • 제10권2호
    • /
    • pp.20-28
    • /
    • 2011
  • 저궤도 관측위성의 광학탑재체는 궤도에서 임무수행을 뒷받침하는 위성 본체와 열적으로 분리되어 각각 독립된 열제어를 할 수 있도록 개발된다. 광학탑재체는 내부에 작동하는 동안에 높은 발열량으로 순간적으로 온도가 상승하는 부품 박스인 FPA(Focal Plane Assembly)의 열을 외부로 방출하기 위한 히트파이프, 방열판으로 구성된 냉각 장치(Cooling Unit)를 가지고 있다. 이러한 냉각 장치는 고온 조건에서 내부 발열을 빠르게 외부로 방출할 수 있는 히트파이프의 성능과 충분한 면적의 방열판 면적을 확보하도록 설계되어야 하고, 동시에 저온 조건에서 최저 온도 이상을 유지하는 위한 히터설계도 포함해야 한다. 본 연구에서는 먼저 FPA 냉각 장치의 열제어 요구조건과 현재 열설계 기준의 열해석 결과를 통하여 히터설계에 대한 검토와 설계 제한 조건을 분석을 하였다. 또한 열해석을 이용한 효율적이고 경제적인 위성 히터설계 방식을 제시하고, 이것을 FPA 냉각 장치의 히터설계에 적용하여 개선된 히터설계 요소를 찾았다.

유닛모듈러 건축물의 설계 초기 단계에서의 고려 사항 (Considerations in the early stage of Designing the Unit Modular Building)

  • 이영호;이두헌;김균태
    • 한국건설관리학회논문집
    • /
    • 제13권6호
    • /
    • pp.133-142
    • /
    • 2012
  • 최근 저탄소 녹색성장 등 건설 환경의 변화에 따라 친환경적이고 시공 효율성을 극대화할 수 있는 유닛모듈러 공법 등과 같은 새로운 건축시스템에 대한 요구가 증대되고 있다. 유닛모듈러 공법은 전체 공정의 80%이상을 공장에서 제작하고 현장에서는 유닛모듈 조립과 마감작업 위주로 작업이 진행되므로 설계 및 공장 제작 등 현장시공 이전 단계의 품질이 건축물 전체의 품질을 좌우하는 특성을 가진다. 국내 유닛모듈러 공법은 2003년 학교 건축물의 적용을 시작으로 점차 확대되고 있지만, 적용 사례와 관련 자료의 부족, 모듈러 생산업체의 영세성 등으로 유닛모듈러 공법의 특성을 충분히 반영한 설계, 공장제작 및 현장시공은 아직 이루어지지 못하고 있는 실정이다. 본 연구는 국내 유닛모듈러 건축물의 설계품질 향상의 일환으로 공장제작 및 현장시공 단계에서의 문제점을 도출하고, 그 원인을 비교 분석함으로써 유닛모듈러 건축물의 설계 초기 단계에서 고려해야 할 주요 검토 항목을 제시하였다.

환자중심의료를 위한 병동디자인이 환자가족 및 의료진에 미치는 효과에 대한 연구 - 미국의 환자중심의료를 위한 중환자병동 사례를 중심으로 (A Study on the Effect of Unit Design for Patient-Centered Care on Family Members and Caregivers - A Case Study of the Intensive Care Unit (ICU) for Patient-Centered Care in the United States)

  • 최영선
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제21권3호
    • /
    • pp.37-45
    • /
    • 2015
  • Purpose: The main objective of this paper is, to evaluate the unit design for patient-centered care and to draw lessons-learned for further improvement. Methods: This study conducted a case study of the intensive care unit, designed to fulfill patient-centered care in the US. It evaluated the effectiveness of the unit by incorporating several study methods such as plan analyses, direct observations through nursing tracking and behavior mapping, and focus group interviews. Results: The major design decision made in this patient-centered unit was the use of patient rooms with designated family areas and distributed nursing stations. Both design features appeared to be a success on a variety of research metrics and outcomes. The study identified that the patient rooms ultimately help family members to spent more time with their loved ones, which leads to increased satisfaction of family members and nurses also report that they generally enjoy the distributed nurses' stations, which provide a comfortable environment to complete their regular lines of work such as charting, monitoring patients, and collaborating with their colleagues. Implications: Certain design features in intensive care units such as patient rooms with designated family areas and distributed nursing stations could appropriately support hospitals to fulfill patient-centered care.

감염 예방을 위한 인공신장실 의료 환경에 대한 고찰 - 근거 기반의 디자인 중심으로 (A Review of Renal Dialysis Unit Environment for Infection Prevention - Focused on Evidence Based Design)

  • 한수하;윤형진
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권3호
    • /
    • pp.49-57
    • /
    • 2018
  • Purpose: The increase in patients requiring hemodialysis has resulted in an increase dialysis-associated infections risk. but there are no Renal Dialysis unit design standard meet specified safety and quality standards. Therefore, appropriate Establish standards and legal regulation is important for the provision of initial certification and maintenance of facility, equipment, and human resource quality. Methods: Literature survey on the design guideline and standards of Renal Dialysis unit design in Korea, U.S, Germany, Singapore, Hongkong, Dubai. Results: There are no established standards for facilities in dialysis units in Korea. To prevent infections in dialysis patients, necessary establish standards. Considering the domestic and overseas Health-care facilities standards, the major factors to be considered in the medical environment for Renal Dialysis Unit are as follows. First, planning to separate Clean areas(treatment area) from contaminated areas(medical waste storage area). Second, ensure sufficient space and minimum separation distance. Although there may be differences depending on the circumstances of individual institutions, renal dialysis unit consider the space to prevent droplet transmission. Third, secure infrastructure of infection prevention such as sufficient amount of hand hygiene sinks. Hand washing facilities for staff within the Unit should be readily available. Hand hygiene sinks should be located to prevent water from splashing into the treatment area. Fourth, Heating, ventilation and air conditioning (HVAC) system for Renal Dialysis Unit is all about providing a safer environment for patients and staff. Implications: The results of this paper can be the basic data for the design of the Renal Dialysis Units and relevant regulations.

설계의 안전성 검토를 위한 건설공사의단위작업 분석: OO공사의 발주공사를 중심으로 (Analysis of Unit-works for Design for Safety in Construction Work : Focus on Construction Projects of OO Corporation)

  • 김진원;조건희;송상훈;방종대;손정락
    • 토지주택연구
    • /
    • 제7권4호
    • /
    • pp.315-322
    • /
    • 2016
  • 최근 국토교통부는 실시설계 단계에서 설계의 안전성 검토를 실시할 수 있도록 건설기술진흥법을 일부 개정하였다. 설계의 안전성 검토에서 위험성을 판단하기 위해서는 단위작업별 재해의 발생빈도수와 심각성을 파악해야 한다. 따라서 본 연구에서는 ${\bigcirc}{\bigcirc}$ 공사의 건설재해자료(471건)를 24개 단위작업으로 분류하고, 각 단위작업별 재해발생 빈도수 및 심각성을 분석하였다. 그 결과를 토대로 단위작업별 안전관리 수준을 3개 그룹(특별관리, 중점관리, 상시 관리)으로 제안하였다. 본 연구결과는 건설공사에서 설계의 안전성 검토를 하는데 있어 기초정보로 활용될 수 있을 것이다. 또한 이 정보를 활용하여 재해발생률을 저감시킬 수 있을 것으로 판단된다.

다중 프로세서 칩을 위한 시스템 제어 장치의 구조설계 및 FPGA 구현 (Architecture design and FPGA implementation of a system control unit for a multiprocessor chip)

  • 박성모;정갑천
    • 전자공학회논문지C
    • /
    • 제34C권12호
    • /
    • pp.9-19
    • /
    • 1997
  • This paper describes the design and FPGA implementation of a system control unit within a multiprocessor chip which can be used as a node processor ina massively parallel processing (MPP) caches, memory management units, a bus unit and a system control unit. Major functions of the system control unit are locking/unlocking of the shared variables of protected access, synchronization of instruction execution among four integer untis, control of interrupts, generation control of processor's status, etc. The system control unit was modeled in very high level using verilog HDL. Then, it was simulated and verified in an environment where trap handler and external interrupt controller were added. Functional blocks of the system control unit were changed into RTL(register transfer level) model and synthesized using xilinx FPGA cell library in synopsys tool. The synthesized system control unit was implemented by Xilinx FPGA chip (XC4025EPG299) after timing verification.

  • PDF

플랜트 구조물의 모듈화 공법 (Modularization of plant structures)

  • 서한설;장상수
    • 플랜트 저널
    • /
    • 제13권3호
    • /
    • pp.30-35
    • /
    • 2017
  • Module은 세부적으로 PAS(Pre-Assembled Steel structure), PAR(Pre-Assembled pipe Rack), PAU(Pre-Assembled Unit), VAU(Vendor Assembled Unit) 그리고 VPU(Vendor Package Unit)로 분류될 수 있다. 이러한 Module의 설계 및 제작 시에는 Stick built type 구조물과는 달리 육상 또는 해상 운송 조건이 고려되어야 하며, 운송 조건에 따른 Module division design이 수반되어야 한다. 육상 운송 및 설치를 위해서는 무게중심(Center of gravity) 관리가 중요하며, 해상 운송을 위해서는 구조물이 Sea acceleration force에 대해 안전성을 확보할 수 있도록 설계되어야 한다. 운송 조건 및 설치 방법은 구조물의 규모와 무게를 제한하게 되며, 이는 Module 대상 구조물 선정 시, 그리고 선정된 Module의 분할 계획 시 요구조건으로 작용하게 된다.

  • PDF