• Title/Summary/Keyword: Design Test Evaluation

Search Result 2,818, Processing Time 0.035 seconds

Research on the Design and Evaluation of a Control Loading System for Flight Simulator (비행 시뮬레이터용 조종력 재현 장치 설계 및 시험연구)

  • Lee, Chan-Seok;Kim, Byoung-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.95-100
    • /
    • 2004
  • This paper represents the development of a CLS(Control Loading System) for a target a airplane (KT-1) with mechanical linkage reversible flight control system. The system is composed of mechanical frame, controller, sensing part to measure the force from the stick, driving system generating the reaction forces. The DS1103 DSP(Digital Signal Processor) of the dSpace Corp. was used as the controller. The control algorithm of the CLS and the operational environment including monitoring software and evaluation tools are described. The evaluation of the system was conducted according to the requirement specification. The results of the test were analyzed by comparing with the actual data of the target airplane.

Children with Disabilities on the Basis of Characteristics and Ease Usability Testing of the Stroller (장애아동 특성과 편리성을 바탕으로 디자인된 유모차의 사용성 평가)

  • Oh, D.Y.;An, N.Y.;Kong, J.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.4
    • /
    • pp.267-273
    • /
    • 2014
  • The purpose of this study is to figure out the stroller for baby with physical disability and to suggest improvement by using the usability test. Usability evaluation is separated by the user and the expert evaluation was conducted. Strollers for disabled users to analyze the evaluation of this experience using a guardian of a child with a disability was conducted targeting 30 people. The function and structure of the stroller easy to evaluate whether the five-point scale. Professional 10 strollers for disabled users with the problems of the design and structure were looking to make a suggestion. In this study, to obtain foreign products and differentiation, functionality, and ease of analyzing the conditions of satisfaction and competitiveness of domestic products will be able to contribute.

  • PDF

Multi-Domain Security Management Framework and Its Performance Evaluation for Protecting BcN Infrastructure (BcN 인프라 보호를 위한 다중 도메인 보안 관리 프레임워크와 성능평가)

  • Jang Jung-Sook;Jeon Yong-Hee;Jang Jong-Soo
    • The KIPS Transactions:PartC
    • /
    • v.12C no.6 s.102
    • /
    • pp.817-826
    • /
    • 2005
  • BcN(Broadband convergence Network) is being developed in order to support a variety of network applications, with enhanced capabilities of QoS(Quality of Service) provisioning and security, and IPv6. In a high-speed network environment such as BcN, it if more likely for the network resources to be exposed to various intrusion activities. The propagation speed of intrusion is alto expected to be much faster than in the existing Internet In this paper, we present a multi-domain security management framework which my be used for a global intrusion detection at multiple domains of BcN and describe its characteristics. For the performance evaluation, we first present test results for the security node and compare with other products. Then we design and Implement an OPNET simulator for the proposed framework, and present some simulation results. In the simulation model, we focus on the performance of alert information in the security overlay network.

A Study on the Evaluation of Clothing Pattern Image by the Personality Type (성격유형에 따른 복식문양 이미지 평가에 관한 연구)

  • 남기선;한명숙
    • The Research Journal of the Costume Culture
    • /
    • v.12 no.1
    • /
    • pp.59-72
    • /
    • 2004
  • The objectives of this study were to investigate the perceptions of Korean female university students for clothing pattern tendency and structural element of clothing pattern image dimension and to find how individual personality type influence the preferred clothing pattern characteristics. For this study, a questionnaire was designed and sent to 600 female university students of Daejeon, Seoul and metropolitan area. The tool used in this study was MBTI(The Myers-Briggs Type Indicator) Form G Korean version and for the analysis of data SPSS 10.0 package were used. 10 representative patterns for this study were floral, dot, stripe, check, animal, abstract & artistic, geometric, vegetable & leaf, paisely, patchwork pattern. The data were analyzed by factor analysis, arithmetic mean, One-Way ANOVA, x²-test. The major findings were as follows: Clothing pattern image dimension perceived by Korean female university students for 10 representative patterns were basic form, deluxe, specialty, and cultural dimension. Among them, basic form and deluxe dimension were major dimensions. In basic form dimension, dot pattern score was high indicating female students perceive it as light, comfortable, clean, cool and simple pattern image. In deluxe dimension, floral pattern scored high and in specialty dimension, abstract and artistic pattern scored high among other pattern image. In cultural dimension, geometric pattern and check pattern scored high. Based on other detailed analysis results, It is concluded that the personality type greatly influence clothing pattern evaluation. For example, in case of color combination of patchwork pattern, there was a difference in color preference depend on a personality type such as sensing(S) or intuition(N). Therefore, sensing personality type preferred adjacent color combination than contrast color combination. Detailed marketing strategy is necessary in planning textile design of merchandise plan.

  • PDF

Design and Evaluation of Osseointegration Analysis System for Dental Implant (치과 임플란트용 골융합 측정기의 설계 및 평가)

  • Lee, Joo-Hee;Kim, Chang-Il;Paik, Jong-Hoo;Cho, Jeong-Ho;Chun, Myoung-Pyo;Jeong, Young-Hun;Lee, Young-Jin;Lee, Jeong-Bae;Lee, Seung-Dae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.3
    • /
    • pp.188-193
    • /
    • 2011
  • The osseointegration of dental implant is influenced by many factors such as surface geometry, loading and the amount of bone. Thus, stability of the dental implant should be checked periodically. In order to test the stability of dental implant by using resonance frequency analysis, we designed a structure of transducers and fabricated a piezoelectric devices. Using finite element analysis, the thickness and length of piezoelectric device and transducers were tailorized and the optimized frequency of 10 kHz was obtained. The resonance frequency from simulation analysis and evaluation was estimated to be similar as 10 kHz. The osseointegration was further enhanced with increasing frequency from the evaluation result of the finite element analysis.

Current Research Trend on the Acupuncture and Moxibustion Treatment for Pancreatitis (국내외 췌장염 관련 침구치료 연구 현황)

  • Kang, Ha Ra;Lee, Yeon Sun;Kim, Hye Ryeon;Kim, Eun Jung;Kim, Kyung Ho;Kim, Kap Sung;Jung, Chan Yung;Lee, Jun Kyu
    • Korean Journal of Acupuncture
    • /
    • v.35 no.2
    • /
    • pp.56-69
    • /
    • 2018
  • Objectives : The aim of this study is to review the current research trend on the acupuncture and moxibustion treatment for pancreatitis. Methods : Through nine search engines, articles were collected, which had involved the use of acupuncture and moxibustion treatment for pancreatitis. Data were extracted from the selected articles regarding the year, country, type of pancreatitis, study design, evaluation variable, intervention, point for acupuncture and moxibustion, and effectiveness of treatment. Results : Total 56 articles were reviewed. The number of studies increased gradually every ten years. Fifty-one studies(91%) were conducted in China. Most of clinical studies and animal experimentations reported on acute pancreatitis. Thirty-nine studies were randomized controlled trials(RCTs), but most of them were assessed as uncertain in the risk of bias evaluation. The degree of overall improvement(79%) was used mainly as evaluation variable of clinical studies. In animal experimentations, the examination of pancreatitis tissue(77%) and blood test(77%) were used the most. Most of studies were conducted with the acupuncture, one with moxibustion. Among them, electroacupuncture was the most common intervention of treatment group. ST36 was the most frequently used acupuncture point in the included studies. Effective rate increased and serum amylase, clinical symptoms, recovery time of gastrointestinal function decreased statistically significantly in the treatment group of clinical studies. Conclusions : The result of this study could be used for the future practice and research about the acupuncture and moxibustion treatment for pancreatitis.

Study on Ultrasonic Transducer for Non-Destructive Evaluation of Highly Attenuative Material Using PMN-PT Single Crystal (PMN-PT 압전 단결정을 이용한 고감쇠 재료 비파괴 평가용 초음파 탐촉자 연구)

  • Kim, Ki-Bok;Ahn, Bong-Young;Kim, Young-Gil;Park, Sang-Ki;Ha, Jeong-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.313-320
    • /
    • 2007
  • Recently, a new class of single-crystal piezoelectric materials such as lead metanibobate doped with lead titanate (PMN-PT) has been synthesized and were found to further enhance the electro-mechanical coupling factor compared to piezo-ceramic materials. This paper describes fabrication and evaluation of PMN-PT single crystal ultrasonic transducers for contact measurement of stainless steel that is one of the highly attenuative materials. The design conditions for ultrasonic transducer such as front matching layer between test materials and piezo-material and backing materials were investigated based on the simulation results by KLM model. The PMN-PT single crystal ultrasonic transducers with centre frequencies at 1 and 2.25 MHz were fabricated and their performances were evaluated.

A Study on Contribution Analysis using Operational Transfer Path Analysis based on the Correlation between Subjective Evaluation and Zwicker's Sound Quality Index for Sound Quality of Forklifts (지게차의 주관적 음질평가와 Zwicker 음질지수의 상관관계 및 전달경로분석법(OTPA)을 활용한 음질 기여도 분석)

  • Kim, Beom Soo;Yang, Soon Yong
    • Journal of Drive and Control
    • /
    • v.13 no.2
    • /
    • pp.19-25
    • /
    • 2016
  • Recently, drivers have begun to regard comfort in the cabin as one of the most important factors in construction equipment like forklifts. Accordingly, it has become more important to design a forklift cabin with a better sound quality as well as lower sound level, which can make a driver more comfortable. In this paper, the correlation between subjective evaluation and Zwicker's sound quality index was analyzed through a blind test by a few workers in forklifts and other construction equipment in several countries. Correlation analysis showed that Loudness and Sharpness were ranked in sequence, and tendencies were different from country to country. Also, contribution analysis for Loudness and Sharpness using operational transfer path analysis (OTPA), which is widely used in the field of noise, vibration, and harshness (NVH), was performed. However, Loudness and Sharpness cannot be used with OTPA directly because there are no linear relationships between the sources and receivers. In this paper, both are calculated by applying the DIN 45631 method with a contribution rate (%) of 1/3 Octave Sound Pressure Level by OTPA method in addition to considering spectral masking.

Evaluation of Sound Quality for Ergonomic Design of Movable Parts in a Refrigerator (냉장고 동작부품의 소음특성 분석을 통한 감성품질 개선)

  • Kang, Seong Yeop;So, Sae Rom;Kim, Gun Ou;Kim, Ji Hoon;Park, Sang Hu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.7-15
    • /
    • 2018
  • We propose a method for evaluating sound quality quantitatively to develop high-level home appliances (HA). Generally, a refrigerator has diverse movable parts such as slider, drawer, and folding shelf. Therefore, an engineering treatment to control the noise quality is considered as one of key technologies for a higher level refrigerator. Among the movable parts, we have selected a folding shelf as an example, which is commonly setup inside of a home refrigerator for increasing space convenience, to control the noise quality. However, it is known that its noise level is very high comparing to other movable parts when folding or unfolding actions. In order to evaluate and compare the noise quality, we have tested different eighteen models, and have suggested an impact sound quality index (ISQI) based on subjective evaluation data obtained experimentally by thirty two evaluators. The ISQI was formulated using three sound quality elements (noise peak, raising time, impact duration) to determine psycho-acoustic properties. Through this work, we developed an evaluating process and ISQI that was verified the usefulness by comparing the test results of personal perceptions given by evaluators with the prediction value of ISQI. We showed a good relations between them, so we believe that the proposed method and ISQI can be utilized to control of the noise quality of HA effectively.

Evaluation of Water Quality Change by Membrane Damage to Pretreatment Process on SDI in Wastewater Reuse (하수재이용에서 전처리 막 손상에 의한 수질변화가 SDI에 미치는 영향평가)

  • Lee, Min Soo;Seo, Dongjoo;Lee, Yong-Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.32 no.4
    • /
    • pp.253-263
    • /
    • 2022
  • This study suggests a guideline for designing unit process of wastewater reuse in terms of a maintenance of the process based on critical parameters to draw a high quality performance of RO unit. Defining the parameters was done by applying membrane integrity test (MIT) in pretreatment process utilizing lab-scale MF. SDI is utilized for judging whether permeate is suitable to RO unit. However, result said TOC concentration matching with particle count analysis is better for judging the permeate condition. When membrane test pressure (Ptest) was measured to derive log removal value in PDT, virgin state of membrane fiber was used to measure dynamic contact angle utilizing surface tension of the membrane fiber. Actually, foulant affects to the state of membrane surface, and it decreases the Ptest value along with time elapsed. Consequently, LRVDIT is also affected by Ptest value. Thus, sensitivity of direct integrity test descends with result of Ptest value change, so Ptest value should be considered not the virgin state of the membrane but its current state. Overall, this study focuses on defining design parameters suitable to MF pretreatment for RO process in wastewater reuse by assessing its impact. Therefore, utilities can acknowledge that the membrane surface condition must be considered when users conduct the direct integrity test so that Ptest and other relative parameter used to calculate LRVDIT are adequately measured.