• 제목/요약/키워드: Design Response Spectrum

검색결과 462건 처리시간 0.031초

플랜트 설계 시 배관진동을 유발하는 가진 함수의 수학적 모델링 (A Study on Mathematical Modeling of Forcing Function for the Piping Vibration of Petrochemical Plant Design)

  • 민선규;최명진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.591-595
    • /
    • 1997
  • In analysis of piping vibration of petrochemical plant, the forcing functions mainly depend upon the equipment working mechanism and vibration resources in the piping systems. In general, harmonic function is used for the system with rotary equipments. Mechanical driving frequencies, wave functions, and response spectrum are used for reciprocating compressors, surge vibration of long transfer piping, and seismic/wind vibration, respectively. In this study, for the spray injection case inside the pipe, forcing function was modeled, in which two different fluids are distributed uniformly. To confirm the results, the scheme used for the forcing function was applied for real piping system. The vibration mode of the real system was consistent with the 4th mode obtained by simulation using the forcing function formulated in this study.

  • PDF

ESW형 해수여과장치의 구동 기어감속기에 대한 내진해석 (A Seismic Analysis for Driving Gear Reducer of ESW Traveling Sea Water Screen)

  • 김창원;이영신;김흥태;김지원
    • 한국소음진동공학회논문집
    • /
    • 제22권7호
    • /
    • pp.599-604
    • /
    • 2012
  • In this study, the safety of the driving gear reducer of ESW(essential service water) traveling sea water screen was evaluated through seismic analysis. Mode analysis of gear reducer was performed for reliability of analysis. Seismic analysis was performed in operating basis earthquake(OBE) and safe shutdown earthquake(SSE), which were applied as design condition using floor response spectrum( FRS). The maximum strain of gear reducer under OBE and SSE were 20.4 ${\mu}$ and 33.6 ${\mu}$, respectively. The maximum stresses were 2.42 MPa under OBE condition and 4.36 MPa under SSE condition, which were smaller than the allowable strength of material.

상용 유한요소해석 프로그램을 이용한 축류송풍기의 내진해석 (Seismic Analysis of an Axial Blower Using a Commercial FEM Code)

  • 정진태;임형빈;김강성;허진욱
    • 한국소음진동공학회논문집
    • /
    • 제12권3호
    • /
    • pp.181-186
    • /
    • 2002
  • A seismic analysis is one of crucial design procedures of an axial blower used in nuclear power Plants. The blower should be operated even in ar emergency such as an earthquake. The blower should be designed in order to stand against an earthquake. For the seismic analysis, Ive perform the modal analysis and then evaluate the required response spectrum (PRS) from the given floor response spectrum (FRS). A finite element model of the blower is established by using a commercial FEM code of ANSYS. After the finite element modeling. the natural frequencies. the mode shapes and the participation factors are obtained from the modal analysis. The PRS is acquired by a numerical approach on the basis of the principle of mode superposition. We verify the structura safety of the axial blower and confirm the validity of the present seismic analysis results.

하나로 원자로 수조내 사각보의 동특성 평가 (Evaluation of Dynamic Characteristics of the Box Beam of HANARO Reactor Pool)

  • 김성호;단호진;류정수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.525-525
    • /
    • 2005
  • This study is for the seismic analysis and the structural integrity evaluation of the box beam for supporting nuclear fuel-transfer-basket of the HANARO reactor pool. For performing the seismic analysis and evaluating the structural integrity in air or submerged condition, the finite element model of the fuel-transfer-basket and its supporting box beam(the coupled model) was developed. The hydrodynamic effect is also considered by using added mass concept. The seismic response spectrum analyses of the coupled model under the design floor response spectrum loads of Safe Shutdown Earthquake(SSE) were performed. Through the numerical experiments, the analysis results show that the stress values of the coupled model lot the structural integrity are within the ASME Code limits.

  • PDF

사회기반시설물의 내진설계기준 개선방향에 대한 고찰 (A Discussion on the Improvement of Seismic Design Criteria of Infrastructures)

  • 서형열;박광순;김익현;김동수
    • 한국지진공학회논문집
    • /
    • 제18권5호
    • /
    • pp.231-240
    • /
    • 2014
  • This study reviews the status and validity of seismic design criteria (SDC) for major facilities in Korea, which are composed of performance criteria and technical standard. Various facilities with different seismic design response spectra are analyzed to identify their seismic performance and necessity of eventual retrofit. The results are used to derive improvement directions of SDC. It is also concluded that the technical standard should be improved after the revision of the performance criteria.

지반-구조물 상호작용 효과를 고려한 확률론적 역량스펙트럼법 (Probabilistic capacity spectrum method considering soil-structure interaction effects)

  • 채리토노세테;김두기;김동현;조성국
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.65-70
    • /
    • 2008
  • The capacity spectrum method (CSM) is a deterministic seismic analysis approach wherein the expected seismic response of a structure is established as the intersection of the demand and capacity curves. Recently, there are a few studies about a probabilistic CSM where uncertainties in design factors such as material properties, loads, and ground motion are being considered. However, researches show that soil-structure interaction also affects the seismic responses of structures. Thus, their uncertainties should also be taken into account. Therefore, this paper presents a probabilistic approach of using the CSM for seismic analysis considering uncertainties in soil properties. For application, a reinforced concrete bridge column structure is employed as a test model. Considering the randomness of the various design parameters, the structure's probability of failure is obtained. Monte Carlo importance sampling is used as the tool to assess the structure's reliability when subjected to earthquakes. In this study, probabilistic CSM with and without consideration of soil uncertainties are compared and analyzed. Results show that the analysis considering soil structure interaction yields to a greater probability of failure, and thus can lead to a more conservative structural design.

  • PDF

KBC 2005 내진설계 주요 개정사항 (Significant Changes in the Seismic Design Provisions of the 2005 KBC)

  • 정광량;유병억
    • 기술사
    • /
    • 제38권5호
    • /
    • pp.5-9
    • /
    • 2005
  • The seismic design provisions of the 2005 KBC has been based on the 2000 IBC and has considered the building code situations in Korea. There are site ground motion, soil class, seismic design category in the significant changes of the 2005 KBC. In the case of soft soil condition, the response spectrum acceleration of the 2005 KBC is larger than that of previous code. To reduce the seismic force of the 2005 KBC, it need to introduce the eqrthauke force resisting system with high ductility.

  • PDF

원전기자재 설계와 관련된 내진해석 (Seismic Analysis of Nuclear Power Equipment Related to Design)

  • 이우형;조종래;노민식;류정형
    • 대한기계학회논문집A
    • /
    • 제35권3호
    • /
    • pp.317-323
    • /
    • 2011
  • 본 논문에서는 원자력 발전소 폴라 크레인(polar crane)의 설계를 위해 유한요소법을 통한 내진해석을 수행하였다. 모드 해석(modal analysis)을 통하여 폴라 크레인의 고유진동수와 진동형상을 파악하고 응답스펙트럼(response spectrum)을 통해 폴라 크레인의 내진 안전성을 평가하였다. 그리고 액체저장탱크에 대한 내진해석을 유한요소법을 이용하여 수행하였는데, 탱크가 요동시에 액체가 탱크 외벽에 가하는 힘을 고려한 슬로싱해석과 안전정지지진 하중 조건에서의 해석을 수행하였다. 본 논문에서 유한요소해석 상용코드인 ANSYS를 이용하여 내진해석에 필요한 해석기법과 과정 등을 설계 시에 활용할 수 있도록 제안하였다.

철근콘크리트 보통전단벽의 전단력 증폭효과 근사해석 (Approximate Analysis for Shear Force Amplification Effect in Ordinary RC Shear Walls)

  • 전성하;박지훈
    • 한국지진공학회논문집
    • /
    • 제24권3호
    • /
    • pp.129-139
    • /
    • 2020
  • An approximate analysis method is proposed to predict the dynamic amplification of shear forces in ordinary reinforced concrete shear walls as a preliminary study. First, a seismic design for three groups of ordinary reinforced concrete shear walls higher than 60 m was created on the basis of nonlinear dynamic analysis. Causes for the dynamic amplification effect of shear forces were investigated through a detailed evaluation of the nonlinear dynamic analysis result. A new modal combination rule was proposed on the basis of that observation, in which fundamental mode response and combined higher mode response were summed directly. The fundamental mode response was approximated by nonlinear static analysis result, while higher mode response was computed using response spectrum analysis for equivalent linear structural models with the effective stiffness based on the nonlinear dynamic analysis result. The proposed approximate analysis generally predicted vertical distribution of story shear and shear forces of individual walls from the nonlinear dynamic analysis with comparable accuracy.

Post-earthquake warning for Vrancea seismic source based on code spectral acceleration exceedance

  • Balan, Stefan F.;Tiganescu, Alexandru;Apostol, Bogdan F.;Danet, Anton
    • Earthquakes and Structures
    • /
    • 제17권4호
    • /
    • pp.365-372
    • /
    • 2019
  • Post-earthquake crisis management is a key capability for a country to be able to recover after a major seismic event. Instrumental seismic data transmitted and processed in a very short time can contribute to better management of the emergency and can give insights on the earthquake's impact on a specific area. Romania is a country with a high seismic hazard, mostly due to the Vrancea intermediate-depth earthquakes. The elastic acceleration response spectrum of a seismic motion provides important information on the level of maximum acceleration the buildings were subjected to. Based on new data analysis and knowledge advancements, the acceleration elastic response spectrum for horizontal ground components recommended by the Romanian seismic codes has been evolving over the last six decades. This study aims to propose a framework for post-earthquake warning based on code spectrum exceedances. A comprehensive background analysis was undertaken using strong motion data from previous earthquakes corroborated with observational damage, to prove the method's applicability. Moreover, a case-study for two densely populated Romanian cities (Focsani and Bucharest) is presented, using data from a $5.5M_W$ earthquake (October 28, 2018) and considering the evolution of the three generations of code-based spectral levels for the two cities. Data recorded in free-field and in buildings were analyzed and has confirmed that no structural damage occurred within the two cities. For future strong seismic events, this tool can provide useful information on the effect of the earthquake on structures in the most exposed areas.