• Title/Summary/Keyword: Design Force

Search Result 5,703, Processing Time 0.044 seconds

A Experimental Study on Exclusion Ability of Riprap into Bypass Pipe (저층수 배사관 내 유입된 사석 배출능력에 대한 연구)

  • Jeong, Seok Il;Lee, Seung Oh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.239-246
    • /
    • 2017
  • There are various transversal structures (small dams or drop structures) in median and small streams in Korea. Most of them are concrete structures and it is so hard to exclude low-level water. Unless drainage valves and/or gates would not be installed near bottom of bed, sediment from upstream should be deposited and also contaminants attached to the sediments would devastatingly threaten the water quality and ecosystem. One of countermeasures for such problem is the bypass pipe installed underneath the transversal structure. However, there is still issued whether it would be workable if the gravels and/or stones would roll into and be not excluded. Therefore, in this study, the conditions to exclude the rip stone which enter into the bypass pipe was reviewed. Based on sediment transport phenomenon, the behavior of stones was investigated with the concepts from the critical shear stress of sediment and d'Alembert principle. As final results, the basis condition (${\tau}_c{^*}$) was derived using the Lagrangian description since the stones are in the moving state, not in the stationary state. From hydraulic experiments the relative velocity could be obtained. In order to minimize the scale effect, the extra wide channel of 5.0 m wide and 1.0 m high was constructed and the experimental stones were fully spherical ones. Experimental results showed that the ratio of flow velocity to spherical particle velocity was measured between 0.5 and 0.7, and this result was substituted into the suggested equation to identify the critical condition wether the stones were excluded. Regimes about the exclusion of stone in bypass pipe were divided into three types according to particle Reynolds number ($Re_p$) and dimensionless critical shear force (${\tau}_c{^*}$) - exclusion section, probabilistic exclusion section, no exclusion section. Results from this study would be useful and essential information for bypass pipe design in transveral structures.

Study of Disclusion Time during Mandibular Eccentric Movement in Myofascial Pain Syndrome Patients by T-Scan II, Computerized Occlusal Analysis System (컴퓨터 교학분석기인 T-Scan II를 이용한 측방운동시 구치부 이개시간에 관한 연구)

  • Shin, Jun-Han;Kwon, Jeong-Seung;Kim, Seong-Taek;Park, Hyung-Uk;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.3
    • /
    • pp.187-197
    • /
    • 2011
  • Temporomandibular disorders(TMD) is a collective term which is embracing a number of clinical problems that involve the masticatory musculature, the TMJ and associated structures, or both. Myofascial pain, which is a kind of masticatory muscle disorder of TMD, is the sensory, motor, and autonomic symptoms caused by myofascial trigger points. There has been some controversies regarding etiologies of TMD and MFP. Especially the issue of occlusal conditions has been a critical issue for long time. Despite much efforts, the results of studies regarding occlusal conditions were contradictory. These controversies might be mostly due to various factors resulting from the complex nature of TMD, however, inaccurate and inappropriate study design, selection criteria, methodologies also play significant roles. Recently, a computerized occlusal analysis system, T-Scan II which made it possible to reveal quantifiable time data and relative force data for analyzing occlusion, was introduced. Some authorities suggested that the concept of disclusion time and prolonged disclusion time of posterior tooth and MFP are related using T-Scan II. But the previous studies which used T-SCAN II are not reliable for they did not provide accurate diagnostic criteria of MFP. Morever they did not compare with controls, and had many other problems. The purpose of this study was to evaluate the relationship between MFP and prolonged disclusion time of posterior tooth, which is one of the occlusal factors of TMD, by selecting 30 subjects as the study group through strict criteria and comparing them with 38 controls using T-SCAN II, computerized occlusal analysis system. The results, statistically analyzed, are summarized as follows: 1. Cronbach ${\alpha}$ coefficient of repeated measurements of disclusion time was 0.92. 2. There were no statistically significant differences at repeated measured disclusion time of both side between control and study group. 3. There was no statistically significant diffefence in the disclusion time between right and left side. From the results above, we can suggest that there was no relationship between MFP and disclusion time, so irreversible treatments leading to the reduction of disclusion time for treating MFP would not be appropriate. However more controlled, large scaled study, which consider various occlusal factors, and quantification of symptoms using Helkimo index would be necessary in the future.

Total Polyphenol Contents and Antioxidant Activities of Methanol Extracts from Vegetables produced in Ullung Island (울릉도산 산채류 추출물의 총 폴리페놀 함량 및 항산화 활성)

  • Lee, Syng-Ook;Lee, Hyo-Jung;Yu, Mi-Hee;Im, Hyo-Gwon;Lee, In-Seon
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.233-240
    • /
    • 2005
  • To discover new functional materials using edible plants, antioxidant activities of methanol extracts from various parts of seven wild vegetables were investigated in vitro. Total polyphenol contents, determined by Folin-Denis method, varied from 16.74 to $130.22{\mu}g/mg$. Radical-scavenging activities of methanol extracts were examined using ${\alpha},\;{\alpha}-diphenyl-{\beta}-pirrylhydrazyl$ (DPPH) radicals and 2,2'-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid) (ABTS) assay. Inhibition effects on peroxidation of linoleic acid determined by ferric thiocyanate (FTC) method and on oxidative degradation of 2-deoxy-D-ribose in Fenton-type reaction system were dose-dependent. Athyrium acutipinulum Kodama (leaf and rood), Achyranthes japonica (Miq.) Nakai (seed), and Solidago virga-aurea var. gigantea Nakai (root) showed relatively high antioxidant activities in various systems.

Extraction Characteristics of Flavonoids from Lonicera flos by Supercritical Fluid Carbon Dioxide ($SF-CO_2$) with Co-solvent (초임계유체 $CO_2$ 및 Co-solvent 첨가에 따른 금은화(Lonicera fles)의 Flavonoid류 추출특성)

  • Suh, Sang-Chul;Cho, Sung-Gill;Hong, Joo-Heon;Choi, Yong-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.183-188
    • /
    • 2005
  • Effects of co-solvent polarity, citric acid, pressure, temperature, run time, and co-solvent ratio on extraction of major flavonoids from Lonicera Flos were investigated using supercritical fluid $CO_{2}(SF-CO_{2})$. HPLC analysis revealed addition of pure methanol resulted in low extraction yield of major flavonoids, luteoloin (Lu), Quercetin (Qu), Apigenin (Ap). Under same condition, as co-solvent polarity increased, yields of major flavonoids increased gradually, At optimum co-solvent extraction condirion of 60% aqueous methanol (10%, v/v), yields of Lu, Qu, and Ap were 42.09, 28.18, and 3.49 mg/100 g, respectively. Addition of citric acid to 60% aqueous methanol gave higher, with addition of 1% citrie acid resulting in highest yields of 63.2 (Lu), 39.35 (Qu), and 5.79 (Ap) mg/100 g. Optimum extraction conditions of major flavonoids were 200 bar, $50^{\circ}C$, 60 min, and $CO_{2}$-methanol-water(20: 1.8: 1.2).

Effects of Different Grazing Types of Hilly Pasture on Growth and Meat Quality in Organic Korean Black Goats (산지초지를 이용한 방목유형별이 유기흑염소의 발육과 육질에 미치는 영향)

  • HwangBo, S.;Choi, S.H.;Kim, S.W.;Son, D.S.;Jeon, B.S.;Lee, S.H.;Jo, I.H.
    • Korean Journal of Organic Agriculture
    • /
    • v.16 no.3
    • /
    • pp.309-320
    • /
    • 2008
  • This study was conducted to determine the effects of different types of hilly pasture grazing on growth and meat quality in organic Korean black goats, and to obtain basic data for the production of organic goats. A total of 40 goats with similar age and BW were equally allocated to four dietary treatments in a randomized complete block design. Dietary treatments included grazing types of four different hilly pastures; T1: forages types, T2: organic forages types, T3: native plants types, and T4: browse types, respectively. The trial lasted for 174 days from 15th of May to 5th of November, 2007 in Livestock Genetic Resources Experiment Station, National Institute of Animal Sciences. At the end of trial, all animals were slaughtered to analyze carcass characteristics and meat quality. Average daily gain was significantly (p<0.05) higher for T1 treatments than for others. Dressing percentage was significantly (p<0.05) higher for T1 and T2 than for T3 and T4 treatments. Meat percentage of T1 treatments was significantly (p<0.05) higher than those of other treatments. For meat properties, crude fat content was highest in T3 treatments. Linoleate (18:2n6) and linolenate (18:3n3) contents tended to be higher in T1 than those of other treatments, while arachidonate (20:4n6) content tended to be higher in T3 and T4 than that of other treatments. Shear force was lower (p<0.05) for T3 than other treatments. For sensory results, juiciness and tenderness tended to be greater (p<0.05) in T2 and T3, and flavour tended to be greater (p<0.05) in T3 and T4. The results indicated that grazing in hilly pastures for organic Korean black goats was somewhat less in their performances and carcass characteristics, but not behind in the meat quality and physical characteristics as compared with the conventional regimen. Therefore, it would be expected that goats grazing in hilly pastures made it possible to produce organic animal products with a high safety and also might lead to increase of breeders income and consumers satisfaction.

  • PDF

Fabrication of Portable Self-Powered Wireless Data Transmitting and Receiving System for User Environment Monitoring (사용자 환경 모니터링을 위한 소형 자가발전 무선 데이터 송수신 시스템 개발)

  • Jang, Sunmin;Cho, Sumin;Joung, Yoonsu;Kim, Jaehyoung;Kim, Hyeonsu;Jang, Dayeon;Ra, Yoonsang;Lee, Donghan;La, Moonwoo;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.249-254
    • /
    • 2022
  • With the rapid advance of the semiconductor and Information and communication technologies, remote environment monitoring technology, which can detect and analyze surrounding environmental conditions with various types of sensors and wireless communication technologies, is also drawing attention. However, since the conventional remote environmental monitoring systems require external power supplies, it causes time and space limitations on comfortable usage. In this study, we proposed the concept of the self-powered remote environmental monitoring system by supplying the power with the levitation-electromagnetic generator (L-EMG), which is rationally designed to effectively harvest biomechanical energy in consideration of the mechanical characteristics of biomechanical energy. In this regard, the proposed L-EMG is designed to effectively respond to the external vibration with the movable center magnet considering the mechanical characteristics of the biomechanical energy, such as relatively low-frequency and high amplitude of vibration. Hence the L-EMG based on the fragile force equilibrium can generate high-quality electrical energy to supply power. Additionally, the environmental detective sensor and wireless transmission module are composed of the micro control unit (MCU) to minimize the required power for electronic device operation by applying the sleep mode, resulting in the extension of operation time. Finally, in order to maximize user convenience, a mobile phone application was built to enable easy monitoring of the surrounding environment. Thus, the proposed concept not only verifies the possibility of establishing the self-powered remote environmental monitoring system using biomechanical energy but further suggests a design guideline.

Effect of Perch Type and Height on the Growth Performance, Behavioral Characteristics, and Meat Quality of Broilers (홰 종류 및 높이 설정에 따른 육계 생산성, 행동특성, 계육품질에 미치는 영향)

  • Kim, Hyunsoo;Kim, Hee-Jin;Jeon, Jin-Joo;Son, Jiseon;You, Are-Sun;Kang, Bo-Seok;Hong, Eui-Chul;Kang, Hwan-Ku
    • Korean Journal of Poultry Science
    • /
    • v.48 no.4
    • /
    • pp.227-238
    • /
    • 2021
  • This study investigates the effect of perch type and height on the growth performance, footpad dermatitis (FPD), blood parameters, behavioral characteristics, and meat quality of broilers. A total of 912 one-day-old male Ross 308 broilers (48.23±0.264 g) were subjected to a three x two factorial design of three types of perch (wood, steel, plastic) and two levels of perch height (10→30 cm change, 10 cm fixed) over a five-week experiment. Growth performance, perch availability, litter quality, FPD incidence, serum biochemical parameters, and meat quality of the broilers were evaluated. There were no significant differences in the body weight, feed conversion ratio, and biochemical parameters (except for aspartate aminotransferase), pH, color, and water holding capacity. The incidence of FPD was significantly higher in the plastic perch group than in the wood and steel perch groups (P<0.05) at five weeks of age. Perch use was high in the order of wood, steel, and plastic groups in the daytime and nighttime at one, three, and five weeks of age (P<0.05). Perch use was higher in the 10 cm fixed group than the 10→30 cm group (P<0.05). The shear force of the breast significantly increased in the order of wood, steel, and plastic groups (P<0.05). In conclusion, the group with a fixed perch height of 10 cm had high perch usage. Additionally, the use of wooden perches was higher than that of other materials, and it lowered the incidence of FPD in broilers.

A Study of Accelerator Investment Determinants Based on Business Model Innovation Framework (비즈니스 모델 혁신 프레임워크 기반의 액셀러레이터 투자결정요인 연구)

  • Jung, Mun-Su;Kim, Eun-Hee
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.17 no.2
    • /
    • pp.65-80
    • /
    • 2022
  • Despite the uncertainty and risky factors of startups, the special and critical role of accelerators in carrying out professional nurturing and investment for them is becoming increasingly significant in the startup social-system. However, academic research on investment determinants that have a profound impact on the survival of accelerators is lacking, and there are only a few empirical studies on the classification and importance of factors, and they do not enjoy the benefits of theoretical studies. This study proposes a business model innovation framework based on the business model innovation theory that reflects the nature and properties of startups that are investment targets of accelerators and derives 12 investment decision factors. The framework defines that the target, direction, and performable force of startup innovation are a business model, strategy, and dynamic capability. Besides, the framework analyzes the investment decision factors of the existing accelerators based on the business model innovation framework to verify the suitability and sufficiency of the composition. As a result of the analysis, first, most of the items were faithfully composed from a static point of view of business model innovation, but it was found that the factors related to the core activities to evaluate the activity and customer relationship were insufficient. Second, from the strategic point of view, the necessity of developing factors that can encompass the definition and content of core resources, which are internal strategic factors, was raised. Third, from the dynamic point of view, it was found that many of the investment determinants of accelerators were concentrated on the lower level of dynamic competencies. This can be judged as a result of reflecting the characteristics of a startup that needs to develop a solution with few resources and a small number of team members. In addition, the roles and interrelationships between each factor are not clear, thus it was found as a limiting point for startups to view and evaluate the direction and process in which startups dynamically innovate their business models. This study is considerably differentiated in that it provides a business model innovation framework and offers a theoretical basis for investment determinants by deriving the investment determinants of accelerators based on the framework and design the foundation for subsequent research. The business model innovation framework presented in this study has great implications in that it contributes to the achievement of startups, accelerators, and startup support organizations.

Characteristic on the Layout and Semantic Interpretation of Chungryu-Gugok, Dongaksan Mountain, Gokseong (곡성 동악산 청류구곡(淸流九曲)의 형태 및 의미론적 특성)

  • Rho, Jae-Hyun;Shin, Sang-Sup;Huh, Joon;Lee, Jung-Han;Han, Sang-Yub
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.4
    • /
    • pp.24-36
    • /
    • 2014
  • The result of the research conducted for the purpose of investigating the semantic value and the layout of the Cheongryu Gugok of Dorimsa Valley, which exhibits a high level of completeness and scenic preservation value among the three gugoks distributed in the area around Mt. Dongak of Gogseong is as follows.4) The area around Cheongryu Gugok shows a case where the gugok culture, which has been enjoyed as a model of the Neo-Confucianism culture and bedrock scenery, such as waterfall, riverside, pond, and flatland, following the beautiful valley, has been actually substituted, and is an outstanding scenery site as stated in a local map of Gokseong-hyeon in 1872 as "Samnam Jeil Amban Gyeryu Cheongryu-dong(三南第一巖盤溪流 淸流洞: Cheongryu-dong, the best rock mooring in the Samnam area)." Cheongryu Gugok, which is differentiated through the seasonal scenery and epigrams established on both land route and waterway, was probably established by the lead of Sun-tae Jeong(丁舜泰, ?~1916) and Byeong-sun Cho(曺秉順, 1876~1921) before 1916 during the Japanese colonization period. However, based on the fact that a number of Janggugiso of ancient sages, such as political activists, Buddhist leaders, and Neo-Confucian scholars, have been established, it is presumed to have been utilized as a hermit site and scenery site visited by masters from long ago. Cheongryu Gugok, which is formed on the rock floor of the bed rock of Dorimsa Valley, is formed in a total length of 1.2km and average gok(曲) length of 149m on a mountain type stream, which appears to be shorter compared to other gugoks in Korea. The rock writings of the three gugoks in Mt. Dongak, such as Cheongryu Gugok, which was the only one verified in the Jeonnam area, total 165 in number, which is determined to be the assembly place for the highest number of rock writings in the nation. In particular, a result of analyzing the rock writings in Cheongryu Gugok totaling 112 places showed 49pieces(43.8%) with the meaning of 'moral training' in epigram, 21pieces (18.8%) of human life, 16pieces(14.2%) of seasonal scenery, and 12pieces(10.6%) of Janggugiso such as Jangguchur, and the ratio occupied by poem verses appeared to be six cases(3.6%). Sweyeonmun(鎖烟門), which was the first gok of land route, and Jesiinganbyeolyucheon(除是人間別有天) which was the ninth gok of the waterway, corresponds to the Hongdanyeonse(虹斷烟鎖) of the first gok and Jesiinganbyeolyucheon of the ninth gok established in Jaecheon, Chungbuk by Se-hwa Park(朴世和, 1834~1910), which is inferred to be the name of Gugok having the same origin. In addition, the Daeeunbyeong(大隱屛) of the sixth gok. of land route corresponds to the Chu Hsi's Wuyi-Gugok of the seventh gok, which is acknowledged as the basis for Gugok Wollim, and the rock writings and stonework of 'Amseojae(巖棲齋)' and 'Pogyeongjae(抱經齋)' between the seventh gok and eighth gok is a trace comparable with Wuyi Jeongsa(武夷精舍) placed below Wuyi Gugok Eunbyeon-bong, which is understood to be the activity base of Cheongryu-dong of the Giho Sarim(畿湖士林). The rock writings in the Mt. Dongak area, including famous sayings by masters such as Sunsaeuhje(鮮史御帝, Emperor Gojong), Bogahyowoo(保家孝友, Emperor Gojong), Manchunmungywol(萬川明月, King Joengjo), Biryeobudong(非禮不動, Chongzhen Emperor of the Ming Dynasty)', Samusa(思無邪, Euijong of the Ming Dynasty), Baksechungpwoong(百世淸風, Chu Hsi), and Chungryususuk-Dongakpungkyung(淸流水石 動樂風景, Heungseon Daewongun) can be said to be a repository of semantic symbolic cultural scenery, instead of only expressing Confucian aesthetics. In addition, Cheongryu Gugok is noticeable with its feature as a cluster of cultural scenery of the three religions of Confucian-Buddhism-Taoism, where the Confucianism value system, Buddhist concept, and Taoist concept co-exists for mind training and cultivation. Cheongryu Gugok has a semantic feature and spatial character as a basis for history and cultural struggle for the Anti-Japan spirit that has been conceived during the process of establishing and utilizing the spirit of the learning, loyalty for the Emperor and expulsion of barbarians, and inspiration of Anti-Japan force, by inheriting the sense of Dotong(道統) of Neo-Confucianism by the Confucian scholar class at the end of the Joseon era that is represented by Ik-hyun Choi(崔益鉉, 1833~1906), Woo Jeon(田愚, 1841~1922), Woo-man Gi(奇宇萬, 1846~1916), Byung-sun Song(宋秉璿, 1836~1905), and Hyeon Hwang(黃玹, 1855~1910).

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF