• Title/Summary/Keyword: Desiccant

Search Result 141, Processing Time 0.027 seconds

Performance Analysis of Hybrid Desiccant Chiller Based on Field Test (실증 실험을 통한 하이브리드 제습냉방 시스템의 성능 분석)

  • Ahn, Joon;Yun, Changho;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.621-627
    • /
    • 2013
  • Field tests of hybrid desiccant cooling systems were conducted from July to August 2011. Data were monitored and transferred in real time over the Internet. The monitored variableswere analyzed to determine the performance characteristics under outdoor conditions. A series of system simulations has been conducted for outdoor conditions of the field tests. The results agree well with the experimental data in general. The system performance has been shown to deteriorate for wetter conditions, as predicted by the simulation.

Heat and Mass Transfer in Hygroscopic Rotor During Adsorption and Desorption Process (흡착과 탈착 과정 동안 제습 로터의 열/물질 전달)

  • Shin, Hyun-Geun;Park, Il Seouk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.977-984
    • /
    • 2013
  • A hygroscopic rotor comprises many microchannels with high adsorption characteristics. In this study, the iterative adsorption/desorption processes that were affected by the humid air flow in a channel were numerically simulated. In consideration of the accuracy and computational costs, in the desiccant layer, only surface diffusion was considered in this simulation. The results were compared with the previous numerical results and found to show good agreement. By conjugating the heat and mass transfer between the desiccant and the flow layers, temporal and spatial changes in the vapor mass fraction, adsorbed liquid water mass fraction, and temperature in the channel were presented.

Optimization Design of Liquid Desiccant Cooling System (액체 제습식 냉방 시스템의 최적 설계)

  • Jeon, Dong-Soon;Lee, Sang-Jae;Kim, Seon-Chang;Kim, Young-Lyoul;Lee, Chang-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.419-428
    • /
    • 2010
  • This paper presents the optimization process of liquid desiccant cooling system using LiCl aqueous solution as a working fluid. Operating conditions(mass flow rate, conditioner outlet concentration, difference concentration) and design factors for heat exchangers(difference temperature of the district heating water, leaving temperature difference of the conditioner, leaving temperature difference of the regenerator, air temperature difference of the conditioner, air temperature difference of the regenerator) were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of difference temperature of hot water on system performances was also examined. As difference temperature of the district heating water increases, the cooling capacity increases and COP decreases.

An Experimental Study on the Optimization of Performance Parameter for Membrane Based Dehumidification and Air Conditioning System (분리막 제습공조 시스템의 성능변수 최적화를 위한 실험적 연구)

  • Jang, Jeachul;Kang, Eun-Chul;Jeong, Siyoung;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.75-80
    • /
    • 2016
  • There are three types of dehumidification systems : refrigeration dehumidification method, desiccant dehumidification method and hybrid dehumidification method. The first method involves removing moisture by condensation below the dew point, the second method involves absorption by a desiccant material and the last is an integration method. However, the refrigeration dehumidification system consumes too much power and controlling the humidity ratio is difficult. The desiccant dehumidification system uses less power but it has problems of environmental pollution. The hybrid dehumidification system has the disadvantage of a high initial cost. On the other hand, the energy consumption of the membrane based dehumidification system is lower than for the refrigeration dehumidification system. Also, it is an environmentally friendly technology. In this study, the performance parameters are evaluated for the dehumidification system using a hollow fiber membrane. Available area, duct side dry-bulb temperature, sweep gas flux (flow rate) and LMPD (Log Mean Pressure Difference) were used as the performance parameters.

Comparison of the Dehumidification Performance Between LiCl and LiBr in a Liquid Desiccant Dehumidifying Element Having Criss-Cross Sinusoidal Channels (Celdek) (교차 적층된 파형 액체 제습 소자 (Celdek)에서 LiCl과 LiBr 수용액의 제습 성능 비교)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.27-34
    • /
    • 2018
  • Recently, liquid desiccant systems have received attention for the dehumidification of air. LiCl and LiBr are widely used in liquid desiccant systems due to their excellent thermo-physical properties. In this study, dehumidification tests were conducted with Celdek elements using LiCl and LiBr. During the tests, the dry and wet-bulb air temperatures were maintained at $35^{\circ}C$ and $28^{\circ}C$, respectively. The solution temperature was $20^{\circ}C$, the solution concentration was 50%, the solution circulation rate was 50 kg/h, and the frontal air velocity was varied from 2.0 to 4.0 m/s. The results show that the amount of dehumidification increased as the frontal velocity increased. On average, LiCl showed 27% higher dehumidification performance than LiBr, which was probably due to the lower saturation of the absolute humidity of LiCl compared with that of LiBr. On the other hand, LiBr yielded 12% larger pressure drop than LiCl. In general, the Sherwood numbers of LiCl and LiBr were approximately the same, showing that the effect of the desiccant on the Sherwood number was insignificant. Existing correlations highly overpredicted the present Sherwood numbers.

A Study on Cooling Performance and Exergy Analysis of Desiccant Cooling System in Various Regeneration Temperature and Outdoor Air Conditions (재생온도와 외기조건 변화에 따른 제습 냉방시스템의 냉방 성능 및 엑서지 해석에 관한 연구)

  • Lee, Jang Il;Hong, Seok Min;Byun, Jae Ki;Choi, Young Don;Lee, Dae Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.413-421
    • /
    • 2014
  • Desiccant cooling system is an air conditioning system that uses evaporative cooler to cool air and it can perform cooling by using heat energy only without electrically charged cooler. Thus, it can solve many problems of present cooling system including the destruction of ozone layer due to the use of CFC[chloro fluoro carbon] affiliated refrigerants and increase of peak power during summer season. In this study, cooling performance and exergy analysis was conducted in order to increase efficiency of desiccant cooling system. Especially, using exergy analysis based on the second law of thermodynamics can resolve the issue related to system efficiency in a more fundamental way by analyzing the cause of exergy destruction both in whole system and each component. The purpose of this study is to evaluate COP[coefficient of performance], cooling capacity and exergy performance of desiccant cooling system incorporating a regenerative evaporative cooler in various regeneration temperature and outdoor air conditions.

Possibility of Using Non-selective Herbicides as Desiccants for Improving Soybean Harvest Efficiency (콩 수확 효율 증진을 위한 건조제로서 비선택성 제초제의 활용 가능성)

  • Won, Ok Jae;Hong, Seo yeon;Suh, Eun Ji;Park, Jae-Sung;Lee, Hong Seok;Park, Jin-Ki;Ryu, Jong-Soo;Han, Won-Young;Han, Kil Su;Song, Duk Young
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.66 no.4
    • /
    • pp.358-364
    • /
    • 2021
  • This study was conducted to select a desiccant and determine its concentration for safe usage to improve the harvesting efficiency of soybeans. Soybeans were treated with a desiccant (non-selective herbicide) before and after the maturation stage. The drying effect of the desiccant was higher at earlier treatment times than at the maturation stage, but the difference was not statistically significant. The higher efficacy might be related to the drying process of the leaves and stems, with most of the leaves and stems having already been dried by the time of hand harvesting. Desiccant treatments had no adverse effects on soybean yield, weight of 100 grains, seed quality, or seed germination rate compared with the untreated control. Pesticide residue analysis showed minimum residue concentration to be lower than the tolerance level of pesticide residues. In conclusion, it was confirmed that the desiccant was effective in drying soybean, and that there was no damage to the quality of soybean seeds. In addition to the drying effect, the dessicant treatment also facilitates the removal of weeds that interfere with the mechanical harvest and improves harvesting efficiency through the drying of the growth imbalanced individual. The desiccant treatment is expected to shorten the mechanical harvesting time by 1-2 weeks. It is thought that the selection of the proper cultivation period for other crops after soybean cultivation will be more advantageous.

증발냉방 및 제습냉방 기술 및 동향

  • 송찬호
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.34 no.2
    • /
    • pp.18-22
    • /
    • 2005
  • 증발냉방 및 Desiccant를 적용한 냉방시스템의 기술 및 동향을 소개하고자 한다.

  • PDF