• 제목/요약/키워드: Descending velocity

Search Result 57, Processing Time 0.02 seconds

Observation of Ground Subsidence in Bangkok, Thailand Using PSInSAR Technique (PSInSAR 기법을 이용한 태국 방콕 지반침하 관측)

  • Jeon, Woohyun;Yi, Jonghyuk
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1625-1630
    • /
    • 2021
  • In Bangkok, Thailand, there is an increasing concern for ground subsidence with the rapid urbanization. Given the presence of flood vulnerability due to the flat low-lying topography and proximity to the river delta, it is particularly significant to monitor deformation that can potentially augment flood hazards. In this paper, we have applied persistent scatterer interferometric synthetic aperture radar (PSInSAR) technique to investigate subsidence in Bangkok with the use of Sentinel-1 acquisitions spanning from June 2018 to October 2021. The vertical displacement velocity obtained from both ascending and descending orbits revealed regional-scale subsidence at rates up to 30 mm/yr. In addition, ongoing subsidence was observed in the suburb areas with the localized vertical subsidence exceeding 80 mm. The areas are primarily industrial and agricultural sectors, thus, the ground subsidence detected is probably caused by groundwater withdrawal. However, further work is needed to diagnose the trends of aquifer resources.

Model Tests on a Plastic Pipe Pile for the Analysis of Noise, Energy Transfer Effect and Bearing Capacity due to Hammer Cushion Materials (해머 쿠션 재질에 따른 모형말뚝의 소음, 에너지 전달효율 및 지지력 분석)

  • Lim, Yu-Jin;Hwang, Kwang-Ho;Park, Young-Ho;Lee, Jin-Gul
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.12
    • /
    • pp.33-43
    • /
    • 2006
  • Driving tests using model plastic piles with different hammer cushion materials were performed in order to evaluate the efficiency of energy transfer ratio from the hammer, degree of vibration of the surrounding ground and noise due to impacting. A small pile driving analyzer (PDA) was composed using straingages and Hopkinson bar which is measuring force signal and pile-head velocity. The hammer cushion (cap block) materials used for the model driving tests were commercial Micarta, plywood, polyurethane, rubber (SBR) and silicone rubber. The highest energy transfer ratio was obtained from Micarta in the same soil and driving conditions. Micarta was followed by polyurethane, plywood, rubber and silicone in descending order. The more efficient energy transfdr ratio of the hammer cushion materials became, the bigger average noisy (sound) level was found. In addition, Micarta and polyurethane provided bigger bearing capacities than other materials compared in the same soil and driving conditions in which the static loading tests were performed at the end of driving.

Evaluation of frictional forces between orthodontic brackets and archwires (교정용 브라켓과 교정선 사이의 마찰력)

  • Jeong, Tae-Jong;Choie, Mok-Kyun
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.613-623
    • /
    • 2000
  • The purpose of this study was to amount of the frictional forces with the brackets and wires, ligation methods, dry/wet, offsets, interbracket distances, velocity and to compare them each other by different conditions. This study tested 0.018'x0.025' slot sized 8 types of orthodontic bracket systems and 0.016', 0.016'x0.022' sized stainless steel, NiTi, Cu-NiTi orthodontic wires. One cuspid bracket were positioned on the slide glass and archwire was engaged into bracket and ligated with elastomeric modules. The values of frictional forces were measured with the instron universal testing machine. The results were as follows; 1. Polycrystalline ceramic bracket had the highest mean frictional forces and followed and by ceramic reinforced plastic bracket, metal bracket, plastic bracket with metal slot, monocrystalline ceramic bracket, single bracket, self-ligating bracket, friction free bracket in descending order. The self-ligating bracket showed low frictional forces in the round wires and high frictional forces in the rectangular wires. 2. Stainless steel wires had the least frictional forces and followed by NiTi, Cu-NiTi wires in descending order. Round wires had lower frictional forces then that of rectangular wires. 3. The stainless steel ligation method had significantly greater mean frictional forces them the elastomeric module ligation method. 4. Artificial saliva statistically increased the frictional forces in stainless steel wire, NiTi wire and Cu-NiTi wire. 5. There was a statistically significant difference with offset change 6. There was no statistically significant difference with interbracket distance in stainless steel wires but a significant difference in NiTi wires as the interbracket was decreased. 7 There was no statistically significant difference with velocity change. From the above findings, self-ligating bracket, stainless steel wires and the elastomeric module ligation method might be effective than any other materials to reduce the frictional forces in the orthodontic treatment and can be correlated to clinical situations seen in orthodontic patient care.

  • PDF

Characteristics of the Land and Sea Breeze on Cheju island , Korea (제주도 지방의 해륙풍의 특성)

  • 김유근
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.1
    • /
    • pp.41-55
    • /
    • 1991
  • A study was done to investigate characteristics of the land and sea breeze over Cheju island on the basis of surface meteorological data collected from 1977 to 1986. The results are summarized as follows: The frequency of the land and sea breze was highest in August followed by September, October, May and November in descending order. This indicates that the frequency of the land and sea breeze is higher in fall than in spring, and lowest in winter. The sea breeze began much earlier than any other regions of Korea all the year round, and it began about 30 minutes earlier and ended one hour later in the northern coast than in the southern coast of Cheju island. Meanwhile, the land breeze began about one hour earlier in the southern coast than in the northern coast and ended almost at the same time in both coasts. The annual mean duration of the sea breeze was about one hour longer in the northern coast than in the southern coast, but the land breeze showed an opposite trend. The duration of the sea breeze was longer in summer than in winter and again the land breeze was opposite. Transition period from the sea to the land breeze was relatively long in summer and shout in winter, but transition period from the land to the sea breeze was not different between seasons. The time for a maximum velocity of the sea breeze came earlier in the southern coast than in the northern coast, but that of the land breeze came almost at the same time in both coasts with no seasonal variations. Monthly mean maximum velocity of the sea breeze was greater than that of the land breeze.

  • PDF

Experimental Study on the Characteristics of Combustion in the Indirect Moxibustion with Ginger (격강구(隔薑灸)의 연소(燃燒) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Lee, Geon-mok;Lee, Geon-hui;Moon, Sung-jae;Hwang, Byung-chun;Guk, Uo-suk;Jang, Ji-yeon;Kim, Yang-jung;Jang, Jae-ho;Yun, Ju-young
    • Journal of Acupuncture Research
    • /
    • v.21 no.3
    • /
    • pp.193-214
    • /
    • 2004
  • Objective : The purpose of this study is to investigate the mechanism and effect of moxibustion with ginger objectively, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxibustion with ginger. Methods : We have selected the indirect moxibustion with ginger among many indirect moxibustions. We produced a slice of ginger to a thickness of 3, 4, 5mm and the moxa cone having a diameter of 8mm, a height of 10mm for making a comparative study of characteristics of moxa cone according to change the density. We have made a comparative study of the thermodynamic characteristics of moxibustion with ginger with or without holes. We measured combustion times and calculated temperatures, temperature gradients in each period during a combustion of moxa. Results : 1. We found out it was not significantly influenced by the existence of the punched holes in a slice of ginger because the punched holes grow smaller immediately. 2. The duration of the preheating period became longer according to thickness of a slice of ginger and was not directly proportional to the density of moxa cone. The duration of the preheating period was extremely short when it burned a 100mg moxa cone. That was influenced by the density of moxa cone. 3. The duration of the heating period became longer according to thickness of a slice of ginger likewise the preheating period bacause the density of moxa cone had effected on the combustion characteristics. The duration of the heating period was extremely long when it burned a 100mg moxa cone. On the other hand the maximum temperature in the heating period was appeared that the combustion with a thin slice of ginger was highest and measured that the large density of moxa cone was higher. But the maximum temperature in the heating period was about $37.8^{\circ}C{\sim}44.2^{\circ}C$respectively lower in others. 4. The duration of the retaining period was some doubling shorter than that of the heating period that is concerned the shape of moxa cone. The temperature measured the close of a retaining period was $36.6^{\circ}C{\sim}41.8^{\circ}C$, that was considerably lower temperature. 5. The mean ascending temperature velocity and the mean descending temperature velocity were $0.042{\sim}0.073^{\circ}C/sec$, $-0.027{\sim}-0.064^{\circ}C/sec$ respectively. Then, the ascending temperature velocity was some faster than the ascending temperature velocity. Conclusions : The quantitative standard for obtaining the effective heating stimulation is that if the slice of ginger made a hole in it, we had to use the needle above 1.5mm diameter. The recommended size of a slice ginger is the 14mm diameter and the 2~3mm thickness. The moxa cone is formed the conical shape that the base diameter was 8mm, the height was 10mm, the density was $600mg/cm^2$.

  • PDF

Case Studies of Geophysical Mapping of Hazard and Contaminated Zones in Abandoned Mine Lands (폐광 부지의 재해 및 오염대 조사관련 물리탐사자료의 고찰)

  • Sim, Min-Sub;Ju, Hyeon-Tae;Kim, Kwan-Soo;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.24 no.4
    • /
    • pp.525-534
    • /
    • 2014
  • Environmental problems typically occurring in abandoned mine lands (AML) include: contaminated and acidic surface water and groundwater; stockpiled waste rock and mill tailings; and ground subsidences due to mining operations. This study examines the effectiveness of various geophysical techniques for mapping potential hazard and contaminated zones. Four AML sites with sedimentation contamination problems, acid mine drainage (AMD) channels, ground subsidence, manmade liner leakage, and buried mine tailings, were selected to examine the applicability of various geophysical methods to the identification of the different types of mine hazards. Geophysical results were correlated to borehole data (core samples, well logs, tomographic profiles, etc.) and water sample data (pH, electrical conductivity (EC), and heavy metal contents). Zones of low electrical resistivity (ER) corresponded to areas contaminated by heavy metals, especially contamination by Cu, Pb, and Zn. The main pathways of AMD leachate were successfully mapped using ER methods (low anomaly peaks), self-potential (SP) curves (negative peaks), and ground penetrating radar (GPR) at shallow penetration depths. Mine cavities were well located based on composite interpretations of ER, seismic tomography, and well-log records; mine cavity locations were also observed in drill core data and using borehole image processing systems (BIPS). Damaged zones in buried manmade liners (used to block descending leachate) were precisely detected by ER mapping, and buried rock waste and tailings piles were characterized by low-velocity zones in seismic refraction data and high-resistivity zones in the ER data.

Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow (체외순환에서 박동 혈류와 비박동 혈류가 관상동맥 혈류양상에 미치는 영향에 대한 비교)

  • Son Ho Sung;Fang Yong Hu;Hwang Znuke;Min Byoung Ju;Cho Jong Ho;Park Sung Min;Lee Sung Ho;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.101-109
    • /
    • 2005
  • Background: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose of this study was to directly compare the effects of pulsatile and non-pulsatile circulation to coronary artery flow and myocardial preservation in cardiac arrest condition. Material and Method: A cardiopulmonary bypass circuit was constructed in a ventricular fibrillation model using fourteen Yorkshire swine weighing $25\~35$ kg each. The animals were randomly assigned to group I (n=7, non-pulsatile centrifugal pump) or group II (n=7, pulsatile T-PLS pump). Extra-corporeal circulation was maintained for two hours at a pump flow of 2 L/min. The left anterior descending coronary artery flow was measured with an ultrasonic coronary artery flow measurement system at baseline (before bypass) and at every 20 minutes after bypass. Serologic parameters were collected simultaneously at baseline, 1 hour, and 2 hours after bypass in the coronary sinus venous blood. The Mann-Whitney U test of STATISTICA 6.0 was used to determine intergroup significances using a p value of < 0.05. Result: The resistance index of the coronary artery was lower in group II and the difference was significant at 40 min, 80 min, 100 min and 120 min (p < 0.05). The mean velocity of the coronary artery was higher in group II throughout the study, and the difference was significant from 20 min after starting the pump (p < 0.05). The coronary artery blood flow was higher in group II throughout the study, and the difference was significant from 40 min to 120 min (p < 0.05) except at 80 min. Serologic parameters showed no differences between the groups at 1 hour and 2 hours after bypass in the coronary sinus blood. Conclusion: In cardiac arrest condition, pulsatile extracorporeal circulation provides more blood flow, higher flow velocity and less resistance to coronary artery than non-pulsatile circulation.