• Title/Summary/Keyword: Descending control

Search Result 156, Processing Time 0.02 seconds

One-touch Descending Lifeline with Sliding Linkage Structure (슬라이드 링크 구조를 이용한 원터치 완강기)

  • Kim, Wonchan;Na, Dayul;Moon, Hyein;Kim, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.9
    • /
    • pp.42-47
    • /
    • 2021
  • A one-touch descending lifeline that can easily be installed and rapidly evacuated in the event of a fire accident in high-rise buildings was proposed to overcome difficulties of conventional descending lifeline such as complex installation methods and procedures. However, this lifeline exhibits limitations such as restrictions in installation location and large apparatus size. Therefore, this paper proposes a sliding-type descending lifeline, which has a similar operation to that of current one-touch descending lifeline and solves the aforementioned limitations. A double square link mechanism including a sliding four-bar linkage is proposed and the descending lifeline support is redesigned to unfold in two different planes, allowing 3D movement. Additionally, the shape of the support frame is designed to obtain two attachment surfaces that can be attached to a wall, irrespective of the angle between the window and the inner wall. FEA analysis using ABAQUS is performed to ensure that the robustness of the presented support complies with the Fire Control Act Enforcement Decree. Finally, the feasibility of the proposed sliding one-touch descending lifeline is verified through fabrication.

Modulation of the aqueous extract of Bupleuri radix on glycine-induced current in the acutely dissociated rat periaqueductal gray neurons

  • Sung, Yun-Hee;Shin, Mal-Soon;Kim, Tae-Soo;Lee, Sang-Won;Kim, Youn-Jung;Shin, Hye-Sook;Kim, Hong;Kim, Chang-Ju
    • Advances in Traditional Medicine
    • /
    • v.7 no.5
    • /
    • pp.549-555
    • /
    • 2008
  • Bupleuri radix (Umbelliferae), the dried root of Bupleurum Chinense DC, has been clinically used to mitigate pain sensation. The descending pain control system consists of three major components, and modulation of pain in the periaqueductal gray is the most extensively studied descending pain control system. However, the relation of Bupleuri radix on the descending pain control system has not been clarified. In the present study, modulation of the aqueous extract of Bupleuri radix on glycine-induced ion current in the acutely dissociated periaqueductal gray neurons was investigated by using nystatin-perforated patch-clamp technique under voltage-clamp condition. In the present results, the glycine-induced ion current was significantly suppressed by 0.1 mg/ml Bupleuri radix, while treatment with $10^{-5}\;M$ naltrexone, opioid receptor antagonist, alleviated Bupleuri radix-induced inhibition on glycine-induced ion current. The present study showed that the aqueous extract of Bupleuri radix may activate descending pain control system through inhibition on glycine-induced ion current in the periaqueductal gray neurons and this effect is mediated by opioid receptors.

Determination of PID Coefficients for the Ascending and Descending System Using Proportional Valve of a Rice Transplanter

  • Siddique, Md. Abu Ayub;Kim, Wan-Soo;Baek, Seung-Yun;Kim, Yeon-Soo;Choi, Chang-Hyun;Kim, Yong-Joo;Park, Jin-Kam
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.331-341
    • /
    • 2018
  • Purpose: This study was conducted to develop a linear Proportional-Integral-Derivative (PID) control algorithm for the ascending and descending system of a rice transplanter and to analyze its response characteristics. Methods: A hydraulic model using a single-acting actuator, proportional valve and a PID control algorithm were developed for the ascending and descending system. The PID coefficients are tuned using the Ziegler-Nichols (Z-N) method and the characteristics of unit step response are analyzed to select the PID coefficients at various pump speeds. Results: Results showed that the performance of the PID controller was superior in any condition. It was found that the highest settling time and maximum overshoot were less than 0.210 s and 5%, respectively at all pump speed. It was determined that the steady state errors were 0% in all the cases. The lowest overshoot and settling time were calculated to be nearly 2.56% and 0.205 s, respectively at the pump rated speed (2650 rpm). Conclusions: The results indicated that the developed PID control algorithm would be feasible for the ascending and descending system of a rice transplanter. Finally, it would be helpful to plant the seedlings uniformly and improve the performance of the rice transplanter.

Descending Controls: The Self-Regulation of Chronic Pain (하행성 조절계 : 만성 통증에 대한 제어 작용)

  • Kim, Min-Jae;Kang, Soo-Kyung;Chun, Yang-Hyun;Hong, Jung-Pyo;Auh, Q-Schick
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.2
    • /
    • pp.215-219
    • /
    • 2013
  • The descending control system is composed of a group of structures in the midbrain, medulla oblongata and pons that form a network of descending inhibitory projections. In the clinical setting, it has been shown that the application of a electrical counterirritant to these structures and diminishes the pain in patients. Thus, depression and anxiety have been shown to predict the development of chronic neuropathic pain state. These factors could influence pain might also involve descending controls. Interestingly, reduced descending controls are seen in patients with irritable bowel syndrome and theses patients had greater anxiety, depression compared to controls. And, the influence of anxiety on the chronicity of pain and on the descending control pathways should be tested in animal models, using modern techniques. Given this Knowledge, it is no wonder that pain is a highly personal experience that is susceptible to a variety of biologic, pharmacologic, and environmental influences.

Design of All-in-One Descending Lifeline with Reduced Usage Time (사용시간이 단축된 일체형 완강기 설계)

  • Yun, Seul-Gi;Park, Jung-Woo;Jung, Geun-Hak;Jung, Min-Hee;Kang, Sangwook;Kim, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.5
    • /
    • pp.21-26
    • /
    • 2020
  • A descending lifeline is the only self-escape fire apparatus for fire in high-rise buildings and is installed in most buildings according to fire-fighting law. However, it is difficult to properly use and quickly evacuate during an emergency due to its complex installation methods and procedures, even if users are pre-educated. In this paper, a new one-touch descending lifeline, which simplifies usage procedures and can be used regardless of whether users are educated, is proposed to solve the drawbacks of the conventional descending lifeline. All separate parts that require additional installation are initially assembled in a box, and the concept of a double square linkage is proposed to enable escape in a single motion of pushing the handle attached to the box. Three steps of kinematic design are explored to determine an appropriate configuration of double square linkage, and its dimensions are determined using Matlab and NX CAD software. The proposed all-in-one descending lifeline also follows the enforcement decree of the Fire Control Act, and its feasibility is verified through fabrication.

Development of Artificial Neural Network Model for the Prediction of Descending Time of Room Air Temperature (실온하강신간 예측을 위한 신경망 모델의 개발)

  • 양인호;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.1038-1047
    • /
    • 2000
  • The objective of this study is to develop an optimized Artificial Neural Network(ANN) model to predict the descending time of room air temperature. For this, program for predicting room air temperature and ANN program using generalized delta rule were collected through simulation for predicting room air temperature. ANN was trained and the ANN model having the optimized values-learning rate, moment, bias, number of hidden layer, and number of neuron of hidden layer was presented.

  • PDF

A Study on the Development of an Energy Saving Unit for a Hydraulic Elevator (유압식 엘리베이터용 에너지 저감장치의 개발에 관한 연구)

  • Cho, Ihn-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2106-2112
    • /
    • 2013
  • In a traditional hydraulic elevator, elevator car is descended by down control valve, and the oil hydraulic energy must be lost during the descending stroke. In this paper, hybrid type energy saving unit for a hydraulic elevator is researched to save the hydraulic energy which is lost during the descending stroke. The energy is stored as converted electrical energy, and the saved energy is reused as the auxiliary power for the ascending stroke of elevator car or the main power of other parts. The results show that the output characteristics are stable and good and the research is successful and useful to reuse the saved energy during the descending stroke of elevator car.

Surgical Treatment of Ruptured Dissecting Aneurysm of the Descending Thoracic Aorta: 1 Case Report (박리성 흉부대동맥류 파열증의 수술치험 1예)

  • 이두연
    • Journal of Chest Surgery
    • /
    • v.10 no.1
    • /
    • pp.82-89
    • /
    • 1977
  • A rupture of a dissecting aneurysm of the aorta is life threatening disease and calls for emergency surgical treatment. The author recently experienced one case of ruptured dissecting aneurysm of the descending thoracic aorta complicated with left hemothorax who was recovered after emergency operation of Aug. 11, 1976. The patient was a 43 years old farmer with known hypertension [260/120] for 20 years but without any venereal disease and had experienced sudden throbbing chest pain. Chest film and aortogram revealed this case ruptured aneurysm of descending thoracic aorta complicated with left hemothorax. In this case, large dissecting aneurysm extend from proximal part of left subclavian artery below diaphragm and involved with 3.0 and 4.0cm sized elliptical rupture in proximal part of descending thoracic aorta. And so, neither fenestration procedure nor replacement of dacron artificial vessel was suitable for this case. Finally, only the rupture site of aneurysm was treated by covering with fibrous pleura and teflon patch. The post-operative management of this case was planned to control hypertension with antihypertensive drugs. The follow-up was possible up to date about 2months. The patient has been doing well with ordinary activities except mild chest discomfort.

  • PDF

Muscle Activation of Soleus and Tibialis Anterior according to Landing Strategy of Initial Contact during Descending Stairs: Comparison of Forefoot and Whole Foot

  • Choi, Suwoong;Lee, Yunbin;Park, Taeyang;Hwang, Sujin
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.1
    • /
    • pp.16-21
    • /
    • 2021
  • Objective: To control the rate at which body weight drops, forefoot initiates floor contact with the limb relatively extended at each joint. However, when the knee joints could not extend enough with going down the stairs, the forefoot cannot be contact initially. The purpose of this study was to investigate the differences between forefoot and whole foot in initial contract on soleus and tibialis anterior for health young adults when descending stairs. Design: A cross-sectional observational study design. Methods: Fifteen healthy young adults participated in this study. To compare between forefoot and whole foot in initial contact when going down the stairs, this study measured muscle activation on soleus and tibialis anterior. This study used the paired t-test to analyze the collected data and compare the supporting conditions. Results: After analyzing, the muscle activation of soleus was not statistically significant difference as 25.16% at forefoot initial contact and 24.37% at whole foot initial contact when descending stairs (p>0.05). However, the muscle activation of tibialis anterior muscle was significantly difference was 49.19% at forefoot contact and 71.55% at whole foot contact. Conclusions: The results of this study was that the muscle activation of the tibialis anterior was a higher at whole foot contact than that at fore foot contact when descending stairs. This study suggests that the landing strategy of the initial contact is a beneficial effect at the forefoot contact to maintain the postural balance and the muscle performance effectively when descending stairs in individuals with healthy young adults.

A Study on the Prediction of Descending Smoke Time according to the Design Method of Domestic and Foreign Smoke Facilities for the Improvement of Smoke Facilities Standards in Logistics Warehouse (물류창고의 배연설비 기준 개선을 위한 국내·외 배연설비의 설계 방법에 따른 연기하강시간 예측에 관한 연구)

  • Hun, Ye-Rim;Kim, Yun-Seong;Jin, Seung-Hyun;Koo, In-Hyuk;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.141-142
    • /
    • 2022
  • Recently, fires in logistics warehouses in Korea are continuously increasing. In addition, the need for fire safety in logistics warehouses is emerging. So, it is believed that it is necessary to establish standards for vent facilities under effective smoke control for the evacuation safety of residents in logistics warehouses. Therefore, this paper compares the standards related to combustion facilities in Korea, the United States, and Japan, and applies the design method to logistics warehouses of domestic materials to predict smoke drop time and use it as a basic data for improving domestic smoke facilities standards.

  • PDF