• Title/Summary/Keyword: Dept. of Optometry

Search Result 271, Processing Time 0.023 seconds

Change of Contrast Sensitivity in Peripheral Vision Following Eccentric Viewing Training (중심외주시 훈련 후 주변시야에서의 대비감도 변화)

  • Seo, Jae-Myoung;Lee, Ki-Young;Lim, Yong-Moo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.99-104
    • /
    • 2014
  • Purpose: This study was to investigate the functional improvement in peripheral vision following eccentric viewing training. Methods: 14 subjects with normal vision took a part with their right eye, peripheral retinal which is $20^{\circ}$ lateral area from the fovea was examined for contrast sensitivity(CS). Eccentric viewing training was performed for 21days with an hour image viewing and examination was repeated. Results: The critical durations for 0.7 cpd were increased 2.67(467 ms) for pre-eccentric viewing training to 2.79(616 ms) for post-eccentric viewing training (p>0.05). The critical durations for 3.0 cpd were also increased 2.53(341 ms) for pre-eccentric viewing training to 3.04(1102 ms) for post-eccentric viewing training (p>0.05). Conclusions: It is recommended to use higher spatial frequency with higher CS for eccentric viewing training and to train more frequently for a short time. Moreover, the study on Korean standardizing of the visual rehabilitation for low vision based on the etiology is sorely required.

Binocular Visual Functions Effect of Vision Therapy Programs : A Meta-Analysis (Vision Therapy 프로그램의 양안시기능 개선 효과에 대한 메타분석)

  • Lee, Jeong-Yun;Park, Chun Man
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.201-210
    • /
    • 2015
  • Purpose: In order to aggregate effect of the improvement of binocular vision function by vision therapy, total mean effect size, mean effect size by dependent variables, and effect size by characteristics of the subjects and characteristics of treatment were analyzed by meta-analysis. Methods: We analyzed data from 14 Korean National primary studies, which reported effects of vision therapy programs, using meta-analysis. Results: The effect size of total mean was 1.207, which showed high effect. The mean effect size according to the subcategory of the binocular dysfunctions was the highest for vergence dysfunctions group (2.989), followed by accommodative dysfunctions group (0.868) and group with both vergence dysfunctions and accommodative dysfunctions (0.692). The effect size according to the characteristics of the subjects was the highest in the vision therapy conducted in the binocular dysfunctions group (2.509) that had no other dysfunctions. The mean effect size according to the number of programs was the highest (2.310) for 7 times a week. Vision therapy for improving the binocular functions was the most effective (2.019) in 8 weeks later from vision therapy start. Conclusions: It can prove that the therapy for the improvement of binocular vision function is effective through that each result of the vision therapy effect is converted to mean effect size, and being objectifying the mean effect size.

Optical Properties of Cdlnsub 2Ssub 4 and Cdlnsub 2Ssub 4 : $CdIn_2S_4$$CdIn_2S_4 : Co^{2+}$Single Crystals ($CdIn_2S_4$$CdIn_2S_4 : Co^{2+}$ 단결정의 광학적 특성)

  • Choe, Seong-Hyu;Bang, Tae-Hwan;Kim, Hyeong-Gon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.296-302
    • /
    • 1999
  • $CdIn_2S_4 and CdIn_2S_4 : Co^{2+}$ singlecrystals of thenormal spinel structure were grown by the C.T.R. method. The optical energy band structure of these compounds had a indirect band gap at the fundamental optical absorption band edge. The direct and the indirect energy gaps are found to be 2.325 and2.179eV for $Cdln_2S_4$ , and 2.303 and 2.169eV for $CdIn_2S_4 and CdIn_2S_4 : Co^{2+}$ at 5K, respectivly. The fundamental absorption band edge of these single crystals shift to a shorter wavelength region with decreasing temperature, and the temperature dependence of the optical energy gaps in these compounds satisfy Varshni equation. The Varshni constants$\alpha and \beta$ of the direct energy gap are given by $13.39{\times}10_{-4}eV/K$ and 509 K for $Cdln_2S_4$ and $29.73{\times}10_{-4} eV/K$ and 1398K for $CdIn_2S_4 and CdIn_2S_4 : Co^{2+}$. The Varshni constants ${\alpha}and {\beta}$ of the indirect energy gap are given by 9.68${\times}10^{-4}$ eV/K 308K for $Cdln_2S_4$ and $13.33{\times}10_{-4}eV/K$ and 440K for $CdIn_2S_4 : Co^{2+}$ respectivly. The impurity optical absorption peaks due to cobalt dopant are observed in $CdIn_2S_4 : Co^{2+}$ single crystal. These impurity optical absorption peaks can be attributed to the electronic transitions between the split energy levels of $Co_{2+}$ ions located at $T_d$ symmetry site of $Cdln_2S_4$ host lattece.

  • PDF

The Design of Wide Angle Mobile Camera Corrected Optical Distortion for Peripheral Area (주변부 상의 왜곡을 보정한 모바일 광각 카메라의 광학적 설계)

  • Kim, Se-Jin;Jeong, Hye-Jung;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.503-507
    • /
    • 2013
  • Purpose: This study was to design wide angle mobile camera corrected optical distortion for peripheral area, which were reduced optical distortion and TV distortion by using 4 aspherical lenses. Methods: The optical design was satisfied with ${\pm}1%$ optical distortion in viewing angle of $95^{\circ}$ and total length of optical system was less than 4.5 mm which was considering a thickness of mobile camera. 1/3.2 inch (5M) CCD sensor was used in the optical system and set design condition to satisfy MTF which was over than 20% in 140 lp/mm. Results: Optimized wide angle mobile camera showed ${\pm}1%$ optical distortion in full field of $95^{\circ}$ viewing angle and TV distortion was 0.46% so that distortion of peripheral area was reduce. MTF showed over than 20% in every field. Ray aberration and astigmatism were small amount so that it showed stable performance. Conclusions: Obtain wider and clearer view which is reduced image distortion of surrounding area via optical method in wide angle mobile camera which has wider view angle than current mobile camera. And it was able to fix a demerit when it occurred via software correction. It is able to apply to study of camera which is related to spectacles.

Analysis of Refractive Errors of the before and after Cataract Surgery by Auto-refractor (안굴절계를 이용한 백내장 수술전후의 굴절이상 분석)

  • Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.3
    • /
    • pp.65-69
    • /
    • 2016
  • We investigated refractive errors and corneal power with 3 factors such as M, $J_0$, and $J_{45}$ as power vector to find out the changes of refractive errors of the before and after cataract surgery in 119 adults aged 45~85 years with cataract. After the surgery, the 3 factors were changed as $-0.29{\pm}2.38D$ to $-0.18{\pm}0.69D$ in spherical equivalent power which is the M factor, $-0.34{\pm}0.68D$ to $-0.05{\pm}0.42D$ in the $J_0$ factor, and $0.11{\pm}0.45$ to $0.02{\pm}0.17$ in the $J_{45}$ factor. Before and after the surgery, corneal mean refractive power, $J_0$, and $J_{45}$ were changed from $44.11{\pm}1.61D$ to $44.20{\pm}1.58D$, $0.01{\pm}0.50D$ to $0.08{\pm}0.49D$, and $0.02{\pm}0.29$ to $0.08{\pm}0.49$, respectively. The results showed that $J_0$ was the highest relativeness in correlation of the pre- and post-surgery for refractive errors, mean corneal power was the highest correlation for corneal power factor, and corneal power factor was the higher correlation much more than refractive error factor.

A Study on the Factors Affect on Opticians' Customer Orientation (안경사의 고객지향성에 영향을 미치는 요인에 관한 연구)

  • Choi, Youngro;Park, Inn-Jee
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.403-411
    • /
    • 2018
  • Purpose : The purpose of this study is to analyze how the certain efforts of the optical shops affect on opticians' job satisfaction and organizational commitment, and to analyze how opticians' job satisfaction and organizational commitment affect on the customer orientation and to suggest the method of maintaining competitiveness. Methods : Two hundred opticians took participations on the surveys via the Internet survey method and social network system (SNS), and SPSS 18.0 statistics program was used for data analysis; frequency analysis, T-test, factor analysis, reliability analysis, and multiple linear regression analysis were conducted. Results : It is analyzed the differences on the job satisfaction and organizational commitment in accordance with type of optical shops, conducting 5 working days/week and flexible time. As a result, higher job satisfaction is presented with 5 working days/week. Relationships with co-workers statistically affect on job satisfaction positively and emotional labor and work overload statistically affect on job satisfaction negatively. In addition, relationships with co-workers and reward statistically affect on organizational commitment positively and emotional labor and work overload statistically affect on organizational commitment negatively. And opticians' job satisfaction and organizational commitment statistically affect on customer satisfaction positively. Conclusion : It is necessary for the optical shops to make an effort for their opticians to improve the job satisfaction and organizational commitment. And to do so, it is needed to form trusting and respecting relationships with co-workers or superiors. In addition, it is necessary to have continuous communication and education for opticians' self-management. Also, it is needed to establish an effective reward system.

Association between Axial Length and Anthropometric Value in Korean Children (한국 어린이의 안축장과 신체 계측치와의 관련성)

  • Kim, Hyojin;Lyu, Jungmook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.397-402
    • /
    • 2014
  • Purpose: To investigate the relationship between axial length (AL) and anthropometric parameters in Korean children. Methods: This study included 40 urban school children aged 11-12 years (mean age, $11.95{\pm}0.22$ years; 45.0% girls) residing in Seoul, South Korea. AL (using partial coherence laser interferometry), corneal radius, refractive error, height (m), and weight (kg) were measured. Body mass index (BMI $[kg/m^2]=weight/[height]^2$) and degree of obesity (DO[%]=[actual weight standard weight]/standard weight) were calculated. Furthermore, the number of hours spent reading, watching television, and using a computer every day was determined using a detailed questionnaire. Results: The students had a mean spherical equivalent refraction of $1.06{\pm}0.84$ D. Weight (r=0.427, p=0.006), BMI (r=0.508, p=0.001), and DO (r=0.371, p=0.018) showed a significant positive correlation with AL. Furthermore, longer AL was significantly associated with heavier weight (p=0.041), and higher BMI (p=0.015), and higher DO quartiles (p=0.042). After adjust for age, sex, and near-work activities, multivariate linear regression models showed that weight, BMI, and DO were still significantly associated with AL. Among the near-work activities, daily reading time was significantly associated with AL. Conclusions: AL was positively related to weight as well as daily reading time in Korean urban school children.

Study on Physiological Summation in Peripheral Retina for Eccentric Viewing Training (중심외주시 훈련용 주변부 망막의 생리적 가중에 관한 연구)

  • Seo, Jae-Myoung;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.489-493
    • /
    • 2013
  • Purpose: This study was to investigate peripheral vision and provide people with macular degeneration with a guideline for eccentric viewing training. Methods: 30 adult subjects with normal vision took part in this study. The lateral area of $20^{\circ}$ eccentricity from the fovea of right eye was only used to measure the physiological summation. The target was sinusoidal vertical gratings within a circular aperture. The critical points in spatial and temporal summation was found to compare each other for 0.7 cpd and 3.0 cpd, respectively. Results: Critical duration and contrast sensitivity for 0.7 cpd were 540 ms and 1.1, and 315 ms and 0.98 for 3.0 cpd respectively. The critical degrees and contrast sensitivity for 0.7 cpd were $11.3^{\circ}$ and 2.8, and $5^{\circ}$ and 2.63 for 3.0 cpd respectively. Conclusions: The critical point in peripheral vision reaches relatively faster than the one in central vision. It is recommended to train the peripheral retina under the lower spatial frequency more frequently for a short time than constantly for a long time.

Comparison Among the Four Examination Methods for Dry Eye (OQAS test, TBUT, Schirmer Test, McMonnies test) (4가지 건성안 분석방법(OQAS test, TBUT, Schirmer test, McMonnies test)의 비교)

  • Park, Chang Won;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.519-526
    • /
    • 2015
  • Purpose: To evaluate the changes of OSI value according to tear-film instability measured serially by OQAS(Optical Quality Analysis System, Visiometrics, Spain) every seconds. The presented study analyzed the relationship of the OQAS parameter with the results of the tear-film break-up time, Schirmer test, and the McMonies score. Methods: 147 eyes of 82 subjects were randomly selected from university students (age: $21.51{\pm}3.97$, male 45, female 37). Subjects were measured tear-film break-up time, Schirmer test, McMonies score and once every second for 15 seconds after blinking by continuous measurements from OQAS system. Results: The normal eye groups presented OSI values of $2.13{\pm}1.16$ while the dry eye groups had OSI values of $3.76{\pm}1.42$. Therefore, a significant difference between the normal eye group and dry eye group was discovered (p<0.05). In addition, the OSI value of all subjects increased over time. The OSI value, which was measured every second after blinking occurred, significantly increased between 6 seconds and 7 seconds after the start of the measurement (p<0.05). OSI cut off of 30% (sec.) showed a greater correlation; TBUT (r = 0.855, p = 0.000), McMonies test (r = -0.351, p = 0.003), Schirmer (r = 0.316, p = 0.012). Conclusions: Continuous measurement of OQAS showed a high correlation with the value of the existing dry eye tests. Therefore, Analysis of OSI values by utilization of OQAS could be useful in objectively evaluation of tear film in patients.

Study on the Protective Effect of EGCG Against the Cytotoxicity Induced by Topical Anesthetic Proparacaine Hydrochloride (점안마취제 성분인 Proparacaine Hydrochloride의 세포독성에 대한 Epigallocatechin-Gallate의 효과)

  • Seo, Eun-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.525-531
    • /
    • 2013
  • Purpose: To identify the apoptosis caused by Proparacaine hydrochloride (PPC), a topical anesthesia, applied to conjunctival cell lines and determine whether pigallocatechin-gallate (EGCG), has protective effects on. Methods: The conjunctival cell lines were treated with 0.5% of Alcaine$^{(R)}$, 0.5% of PPC and 0.01% of Benzalkonium chloride (BAC) for 15 minutes, respectively in order to investigate the effects of topical anesthesia on cells, and followed by cultured for 12 and 24 hours. The recovery effects were investigated by measuring level of cellular proliferation inhibiting using MTT assay and LDH assay. The conjunctival cell lines were pre-treated with EGCG $10{\mu}M$ for 3 hrs and post-treated with 0.5% PPC for 15 mins in order to investigate whether EGCG has protective effects, flow cytometry were performed in order to observe apoptosis. Results: A result of the additional culture of 12 and 24 hours and again immediately after the treatment for 15 minutes 0.5% of Alcaine$^{(R)}$, 0.5% of PPC, the 0.01% of BAC, cell viability was not increased in all groups (p<0.05). The cell viabilities were higher than in cells 3 hours post-treated with $10{\mu}M$ of EGCG and pre-treated PPC 0.5% (68.2%), compared to cells ($32.2{\pm}2.0%$) treated only with 0.5% of PPC. PPC 0.5% also induced apoptosis in the treated group was reduced by the addition of EGCG. Conclusions: It is considered that the EGCG has cell protective effects when it is added to PPC, a topical anesthesia, by improving cell viability and inhibiting apoptosis.