• Title/Summary/Keyword: Dept. of Optometry

Search Result 271, Processing Time 0.018 seconds

Polymerization of HEMA by Electron beam Irradiation and Fabrication of Soft contact lens (전자빔조사에 의한 HEMA의 중합과 소프트콘택트렌즈 제조)

  • Hwang, Kwang-Ha;Shin, Joong-Hyeok;Sung, Yu-Jin;Jeong, Keun-Seung;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.135-141
    • /
    • 2012
  • Purpose: Polymerization of HEMA(2-hydroxyethyl methacrylate) which can be used in the soft contact lens has been performed by using electron beam(EB) irradiation, and examined the best condition for the polymerization. Comparing the physical properties of the contact lenses to the one fabricated by thermal polymerization method, we check the use possibility of the EB irradiation to the fabrication of the soft contact lens. Methods: We investigated the degree of polymerization of the HEMA according to the composition of the monomer, the additive ratio and the dose of electron beam (0~120 kGy). The degree of polymerization was measured depending on the EB dose to research the best synthetic condition under the EB irradiation. The physical properties of the contact lens such as water content(%), oxygen transmissibility(Dk/t) and optical transmittance were analysed by using the FT-IR results with comparing the two different polymerization method (thermal and electron beam polymerization) with same additive ratio. Results: When the dose of electron beam was above 100 kGy, the degree of polymerization of HEMA was above 99% with regardless using cross-linker and initiator. The water content of the lens fabricated by EB method showed 10% higher than the one by the thermal method which was 40%. The lens fabricated by EB method also showed higher oxygen transmissibility(Dk/t) as same with the water content, and showed twice higher value in the lens fabricated by pure HEMA. According to the FT-IR results, hydrophilic property of the lens fabricated by EB method was increased due to increasing the intermolecular hydrogen bonding. It showed above 90% optical transmittance in the visible range of wavelength on the contact lenses fabricated by the both of two different polymerization method. Conclusions: The polymerization of HEMA without cross-linker and initiator was successful above 100 kGy of EB irradiation. Moreover the lens fabricated from the polymer synthesized by pure HEMA with 100 kGy of EB showed the highest water content and oxygen transmissibility. Therefore EB irradiation is another possible method to synthesize the polymer which can be used for the soft contact lens.

The Functional Change of Accommodation and Convergence in the Mid-Forties by Using Smartphone (스마트폰 사용에 의한 40대 중년층의 조절 및 폭주기능 변화)

  • Kwon, Ki-il;Kim, Hyun Jin;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.127-135
    • /
    • 2016
  • Purpose: The present study was aimed to investigate the effect of excessive near work by using a smartphone on subjective symptoms and accommodative and convergent function in their 40s. Methods: A total of 40 subjects(male, 10; female, 30; age, $43{\pm}7.2year$) in their 40s who have monocular and binocular visual acuities of 0.8 and 1.0, respectively, were divided into presbyopia group and non-presbyopia group. The subjects were asked to watch a movie on the screen of smartphone for 30 minutes. Their accommodative amplitude and facility, and relative accommodation were measured and compared before and after the use of smartphone. Changes in fusional vergence and near heterophoria by using smartphone were also evaluated. Furthermore, the change of subjective symptoms was surveyed using a questionnaire. Results: The presbyopia in mid-40s reported discomfort in an order of asthenopia, blur and dryness after the use of smartphone. Accommodative function and non-strabismic binocular function were generally decreased. Accommodative functions such as monocular accommodative amplitude, and relative accommodation were significantly decreased after smartphone use, and the change of phoria was observed as a result of decreased convergence and divergence. Negative fusional vergence was also significantly reduced. On the other hand, non-presbyopia in mid-40s reported discomfort in an order of asthenopia, dryness and blur, and only accommodative amplitude among the accommodative functions was significantly reduced. Significant reduction of negative fusional vergence was also observed. Conclusion: From the results, it was confirmed that the subjective discomfort of mid-40s after smarphone use might be related to whether presbyopia or not. It was due to not only the reduction of accommodative function but also the overall deterioration of visual function including heterophoria and fusional vergence. Therefore, it suggests that the accurate determination of the cause based on the overall visual functional tests such as heterophoria, fusional vergence as well as the decrease of accommodation due to the aging may be necessary when the mid-40s feels discomfortable symptoms by near work.

Changes in Subjective/Objective Symptoms and the Light Transmissibility of Lens Associated with Overusage of Daily Disposable Circle Contact Lenses in Normal Eyes (일회용 써클소프트렌즈의 초과 착용에 의한 정상안의 자·타각적 증상 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.

A Correlation between Axis-Rotation and Corneal Eccentricity in Toric Soft Contact Lens Fitting in With-the-rule Astigmatism (직난시안에서의 토릭소프트렌즈 피팅 시 축 회전과 각막이심률과의 상관관계)

  • Park, Hyung Min;Park, Kyounghee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.305-313
    • /
    • 2014
  • Purpose: A correlation between the rotating direction and rotation amount according to the eccentricity was analyzed in the present study when fitting the toric soft contact lens. Methods: One hundred fourteen eyes of with-the-rule astigmatism in 20s and 30s were appropriately applied toric soft contact lens by the guideline of manufacturer and fitting evaluations and analyzed the rotating direction and rotation amount when fixating at primary position and 8 different directions of gaze. The speed of reorientation and the correlation between the rotation amount and cornea eccentricity were also analyzed when rotating $45^{\circ}$ each toward the temporal and nasal direction. Results: The cornea eccentricity and rotation amount was shown positive correlation. For the gaze of direction, it was identified that the gaze of directions other than the gaze of direction towards the nasal and temporal had correlation, and among them, the gaze of directions to superior and the superior-temporal showed the tendency of decreasing rotation amount as the cornea eccentricity increased. On the contrary, the gaze of direction towards the inferior, inferior-temporal, superior-nasal, and inferior-nasal showed tendency of increasing rotation amount as the cornea eccentricity increased thus, it was identified that the cornea eccentricity showed different correlation according to the gaze of direction. For the case of re-orientational speed, the speed of lens reorientation in the group having the smallest corneal eccentricity was fastest in both direction but was not significantly different. Conclusions: Considering cornea eccentricity to current method of prescribing toric soft contact lens which is based on total astigmatism, it will be helpful to establish the optimal axis stabilization.

Cause Analysis in Decrease of Body Stability According to The Induced Astigmatic Blur (유발된 난시성 흐림에 의한 신체 안정성 감소의 원인분석)

  • Kim, Sang-Yeob;Yu, Dong-Sik;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.259-264
    • /
    • 2016
  • Purpose: To establish the cause of decrease in body stability and to analyze the effects on sensory organs maintaining static balance according to the induced astigmatic blur. Methods: Twenty subjects (10 males, 10 females; mean age, $23.40{\pm}2.70years$) were participated in this study. To induce myopic simple astigmatism, the axis directions of cylindrical lenses were placed $180^{\circ}$ on both eyes (with-the-rule), $90^{\circ}$ on both eyes (against-the-rule), and $45^{\circ}$ on both eyes (oblique). Cylindrical lenses of +0.50, +1.00, +1.50, +2.00, +3.00, +4.00, and +5.00 D were used to increase astigmatic blur in each astigmatism types. General stability (ST) and sway power (SP) in frequencies by each sensory organs were analyzed using the TETRAX biofeedback system. Results: ST in the all astigmatism types were raised with increase of astigmatic blur compared to full corrected condition, but a significant difference only showed in the induced oblique astigmatism. According to the results of correlation analysis between ST and SP in the each frequencies with increase of astigmatic blur, the causes of increased ST in the induced oblique astigmatism showed to have a high correlation in order of somatosensory system (high-medium frequency), central nervous system (high frequency), peripheral vestibular system (low-medium frequency), and visual system (low frequency). Conclusions: The visual information by uncorrected oblique astigmatism may disturb the normal functions of all sensory organs maintaining body balance, consequently, the body stability can be reduced. Therefore, optimal correction of astigmatism can play an important role for reducing the instability of body balance.

A Study and Analysis of Accommodative Convergence/Accommodation Ratio by Measuring Methods (측정방법에 따른 AC/A비의 조사 분석)

  • Park, Sang-Jae;Kwak, Hyung-Bin;Lee, Se-Hee;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.117-123
    • /
    • 2013
  • Purpose: The aim of this study was to propose effective data for the clinical examinations of binocular vision by comparative analysis of measuring the near horizontal phoria according to accommodative stimulations. Methods: It carried out near horizontal phorias, targeting 104 college students (50 males and 54 females) aged between 19 and 24 ($20.27{\pm}1.31$). It made a comparative analysis of changes in near horizontal phoria according to accommodative stimulations by using the von Graefe, Maddox rod and the Howell phoria methods respectively. We have also investigated the AC/A ratio in all phoria groups. Results: As the additional lenses were changed to the negative (-) diopter, the near horizontal phoria changed to the esodeviation. At this time, the rate of change in the section signifies the AC/A ratio, and the values were not consistent based on the evaluating methods or on each section. The AC/A ratio of the esophoria group appeared the largest value in all groups. As a result of analyzing AC/A ratio at the exophoria group using the von Graefe method, the AC/A ratio was $1.568{\pm}1.937$ ${\Delta}/D$ on the additional lenses +2.00 D and $2.527{\pm}2.253$ ${\Delta}/D$ on the additional lenses -1.00 D and at the esophoria group using the Howell phoria method, the AC/A ratio was $5.521{\pm}1.337$ ${\Delta}/D$, $5.593{\pm}1.623$ ${\Delta}/D$ on the additional lenses +2.00 D, +1.00 D and $4.687{\pm}1.643$ ${\Delta}/D$ on the additional lenses -2.00 D. These were significant differences statistically. Conclusions: In the exophoria group, when the (-) lenses were added, the averages of the AC/A ratio were shown to be high but in the esophoria group, when the (+) lenses were added, the of AC/A ratio was high.

Comparison between Response AC/A and CA/C Ratio according to Additional Spherical Powers and Prism Powers (가입렌즈 도수와 프리즘 굴절력 변화에 따른 반응 AC/A비와 CA/C비 비교)

  • Roh, Byeong-Ho;Yu, Dong-Sik;Son, Jeong-Sik;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.341-347
    • /
    • 2015
  • Purpose : This study was to examine a correlation of response AC/A ratio by additional spherical powers with PD(Pupilary distance) and relative accommodation, and was to investigate correlation of CA/C ratio by prism powers. The mean differences between a reciprocal response AC/A ratio and a CA/C ratio were compared, and were suggested to be used as data in the refractive power and prism prescriptions in the clinical. Methods: The open field autorefractometer (Nvision-K 5001, Shin nippon) and Howell target at 40 cm fixation distance to 62 persons with average $22.62{\pm}2.84$ ages were used to measure the response AC/A ratio according to additional Spherical powers. The CA/C ratios were measured using the DOG card at 40cm according to prism powers. Results: When the response accommodation according to Additional Spherical power changes and the response accommodation according to prism power changes were compared, it was larger than the response accommodation according prism power change. These were significant differences statistically. The correlation of response AC/A ratio and PD is showed as r = -0.158, the CA / C ratio is shown as r = 0.093. The correlation of response AC/A ratio and relative accommodation showed as r = -0.253, the CA/C ratio showed as r = 0.566 that is predictable correlation. The correlation of response AC/A ratio and CA/C ratio showed as r = -0.355 that is low minus correlation (p = 0.000). The difference between a reciprocal response AC/A ratio and a CA/C ratio showed $0.12{\pm}0.06D/{\Delta}$ with a significant difference statistically (p=0.000). Conclusions: The correlation of relative accommodation and CA/C ratio showed that depend on the individual, The more a relative accommodation is, the higher a response accommodation of convergence by convergence stimulus is. The reciprocal response AC/A and CA/C ratio showed significant differences statistically. This can have higher CA/C ratio in patients with low AC/A ratio in clinical as an independent variable. Thus when the abnormal binocular vision was prescribed in the clinical, it is necessary to consider the accommodative response even if the AC/A ratio is a normal range.

Comparison between Stimulus and Response AC/A Ratios for Each Phoria with Additional Spherical Power (사위별 가입렌즈에 따른 자극 AC/A비와 반응 AC/A비의 비교)

  • Lee, Se-Hee;Yu, Dong-Sik;Son, Jeong-Sik;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.345-351
    • /
    • 2014
  • Purpose: The accommodative response and the near horizontal phoria were examined with additional spherical power to analyze the stimulus and response AC/A ratios that suggest reference data for the binocular vision. Methods: The open-field autorefractometer (Nvision-K 5001, Shin nippon) and modified thorington method (MIM card; Muscle Imbalance Measure card, Bernell) at 40 cm were utilized to measure the accommodative response and the near horizontal phoria for 81 persons ($20.89{\pm}1.92$ years old) with additional spherical power. The stimulus and the response AC/A ratios were calculated by gradient AC/A method. Results: The exophoria group showed the highest accommodative response ($1.92{\pm}0.26D$) at 40 cm, followed by orthophoria group and esophoria group($1.72{\pm}0.26D$ and $1.62{\pm}0.42D$, respectively) Meanwhile, the esophoria group showed the biggest ocular deviation for the near ($23.24{\Delta}$) followed by the orthophoria group and exophoria group ($19.76{\Delta}$ and $15.14{\Delta}$, respectively). The biggest difference of the stimulus and the response AC/A ratios was $1.72{\Delta}$ for the exophoria group with -2.00 D, while the one was $3.43{\Delta}$ for the esophoria group with +1.00 D. There was a significant difference between AC/A ratios for the exophoria group with -2.00 D, -1.00 D and the esophoria group with +3.00 D, +2.00D, +1.00D and -1.00D. Conclusions: The difference between stimulus and response AC/A was greater when increased minus spherical power for the exophoria group, while it was greater when increased plus spherical power for the esophoria group. Furthermore, the difference for the esophoria group was a greater than the one for the exophoria group.

Photoluminescence of Hexagonal Boron Nitride (h-BN) Film

  • Jin, Moon-Seog;Kim, Nam-Oh
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.637-639
    • /
    • 2010
  • Hexagonal boron nitride (BN) films were prepared. The process involved, spraying BN powder-dispersed $H_3BO_4-BCl_3$-ethyl alcohol solution on quartz plates, and the drying off quartz plates before, and annealing at $1070^{\circ}C$ in a nitrogen atmosphere. The optical energy band gap of the BN films was 5.28 eV. Photoluminescence peaks with energies of 3.44, 3.16, 2.97, and 2.35 eV at 10 K were observed and analyzed. Accordingly, these have resulted from donor-acceptor pair recombinations.

The research on the characterization solution of eyeglass dispensing & fitting fee in optical shop (안경원의 안경 조제·가공료와 피팅비 정착화에 관한 연구)

  • Leem, Hyun-Sung;Lee, Eun-Hee;Jung, Mi-A
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.12
    • /
    • pp.391-395
    • /
    • 2017
  • In this research, we conducted a questionnaire survey of contents necessary for eyeglass dispensing & fitting fee and characterization solution of eyeglass dispensing & fitting fee. From August 1, 2016 to September 30, questionnaires were set up for 202 spectators of Seoul and Gyeonggi area, questionnaire survey was conducted online and offline. Statistical processing of all data was performed using Origin Pro 8.5. 92.1% (186 people) and 93.1% (188 people) were positively evaluating the necessity of introduction for the necessity of introducing eyeglass dispensing & fitting fee, respectively. The result suggested that it is necessary to establish the position of the optician as a medical service expert by providing a more stable policy through analysis of overseas cases of eyeglass dispensing & fitting fee.