• 제목/요약/키워드: Dependence of Spectrum

검색결과 194건 처리시간 0.029초

Thermal Properties of Mn-doped LiNbO3 Crystals from Magneto-Optical Transitions

  • Park, Jung-Il
    • Journal of Magnetics
    • /
    • 제17권4호
    • /
    • pp.255-260
    • /
    • 2012
  • In this study, we determine that the electron paramagnetic resonance line-width (EPRLW) is axially symmetric about the c-axis and analyze the spin Hamiltonian with an isotopic g-factor of 1.9920 at a frequency of 9.5 GHz. It should be noted that the electron paramagnetic resonance signals are Lorentzian. Our findings show that the EPRLW decreases exponentially with an increase in the temperature; i.e., its temperature dependence in the range 300-400 K obeys Arrhenius behavior, this kind of temperature dependence indicates an off-center a motional narrowing of the spectrum when $Mn^{2+}$ impurity ions substitute for $Nb^{5+}$ ions. The specific heats follow a linear dependence suggesting a simple Debye $T^3$ behavior.

생체내의 초음파 감쇄계수를 측정하기 위한 초음파 신호스펙트럼 특성에 관한 연구 (A Study on Spectral Characteristics of Ultrasonic Signal for Tissue Attennation Coefficient Measurement)

  • 허웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제4권1호
    • /
    • pp.29-36
    • /
    • 1983
  • In this paper, center frequency down slift of ultrasonic echo signals which for the measurements of frequency dependent attenuation in the biological tissue are estimated. Center frequency down shift of echo-signals are estimated after signal spectrum analysis of whole echo-signals. In case of signal spectrums are simple, estimation of down shift frequency is very simple and in case of complicate spectrum, estimation of down shift frequency is depend on spectral shape. In case of unable to estimate, frequency dependence of medium is nonlinear(n) 1), in which upper shift of spectrums are presented. In case of unable to estimate, spectrum analysis are performed at local position. At consquence, we know that spectral dispersions are caused complicately by biological tissue layer.

  • PDF

다방향 불규칙 파랑중 파일 방파제에 의한 산란파 스펙트럼 (Scattering Wave Spectrum by a Pile Breakwater in Directional Irregular Waves)

  • 조일형
    • 한국해안해양공학회지
    • /
    • 제19권6호
    • /
    • pp.586-595
    • /
    • 2007
  • 고유함수전개법을 사용하여 구한 파일 방파제에 의한 규칙파의 산란 해석해를 다방향 불규칙파로 확장하였다. 규칙파중 입사파의 주파수 그리고 입사각을 변화시키면서 구한 반사율과 투과율 그리고 파랑하중을 가지고 산란파 스펙트럼과 하중 스펙트럼을 표현하였다. 주파수와 입사각의 함수인 2차원 스펙트럼을 적분하여 산란파와 파랑하중의 대푯값을 구하고 방향분포함수, 주파향, 잠긴깊이 그리고 공극율이 투과율과 파랑하중에 미치는 영향을 살펴보았다.

Polarization Ellipticity of Micro-photoluminescence in a Single GaAs/AlGaAs Quantum Ring

  • Kim, Minju;Jang, Juyeong;Lee, Seunghwan;Song, Jindong;Kyhm, Kwangseuk
    • Current Optics and Photonics
    • /
    • 제5권1호
    • /
    • pp.72-76
    • /
    • 2021
  • The polarized micro-photoluminescence spectrum was analyzed to investigate the anisotropic localized states in a single GaAs quantum ring. An energy difference of ~0.1 meV was observed from the perpendicularly polarized spectrum measured by a pair of linear analyzers. Spectral dependence of the polarized emission was also characterized in terms of rotation and ellipticity angles using four Stokes parameters. While the rotation angle indicates the symmetric axis of an anisotropic quantum ring with a small variation (± 2°), the ellipticity angle varies from 7.4° down to -2.5°. We conclude that optical anisotropy and birefringence are induced by the crescent-like lateral shape of localized states.

Optically Detected Magnetic Resonance with Nitrogen-Vacancy Spin Ensemble in Diamond

  • Lee, Hyun Joon;Shim, Jeong Hyun
    • 한국자기공명학회논문지
    • /
    • 제22권2호
    • /
    • pp.40-45
    • /
    • 2018
  • We report Optically-Detected Magnetic Resonance (ODMR) study on Nitrogen-Vacancy (NV) centers in diamond. The experiment can easily be conducted with basic optics and microwave components. A diamond crystal having a high-density NV center is suitable for the ODMR study. The magnetic field dependence of ODMR spectrum allowed us to determine the orientation of the diamond crystal. In addition, we measured the variation of the ODMR spectrum as a function of the excitation laser power. Thermal heating induced by optical absorption caused the monotonic decrease of zero field splitting. The contrast of the ODMR peak, however, increased and, then, began to decrease, indicating the optimal laser power for recording the ODMR spectrum.

상전이상태에 있어서 poly(3-alkylthiophene)의 전기전도도와 광학흡수 spectrum의 온도의존성에 관한 연구 (A study on the temperature dependence of electrical conductivity and optical absorption spectrum of poly(3-alklythiophene) in phase transition states)

  • 박복기
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제5권1호
    • /
    • pp.52-70
    • /
    • 1992
  • Poly(3-alkythiophene)은 온도에 따라 전기적 광학적인 성질의 현저한 변화가 관측되었다. poly(3-alkylthiophene)의 전기전도도는 온도가 상승함에 따라 증가하지만 최대치를 유지한 후 용융점에서 단게적으로 감소한다. 가열과 냉각과정 동안 전기전도도의 온도의존성에서 hysteresis가 관측되었다. 이 변칙은 carrier확산에 따른 분자구조 변화의 강한 영향인 것으로 생각된다. 흡수 spectrum 또한 상전이에서 급격히 변화한다. poly(3-alkylthiophene)의 흡수 peak는 액체상태에서 가열하면 energy는 높게 이동한다. 그러나 흡수 edge의 이동은 비교적 작다. 그렇지만 고체-액체 상전이에서 흡수 edge는 energy가 높은 쪽으로 이동한다. 이러한 현상은 고체-액체 상전이에서 poly(3-alkylthiophene)의 구조가 현저하게 변화하고 있는 것으로 설명되며 공역 길이가 짧게되는 것은 큰 구조 변화에 의해 공역계의 평면성 감소에 의한 결과로 생각한다.

  • PDF

A COMPARATIVE STUDY BETWEEN DEGREE OF CONVERSION AND FLEXURAL STRENGTH OF COMPOSITE RESINS

  • Lee Seong-Hee;Pae Ahran;Kim Sung-Hun
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.333-342
    • /
    • 2006
  • Statement of problem. Although many studies have been carried out to investigate the correlation between the degree of conversion and the flexural strength of composite resins, there is minimal information in the literature attempting to compare degree of conversion, flexural strength and their correlation between restorative composite resins and flowable composite resins. Purpose. The purposes of this study were to measure the degree of conversion and flexural strength of composite resins with different rheological behavior and to correlate the two properties. Materials and methods. Four restorative (Vit-1-escence, Z-250, Tetric ceram, Esthet-X) and four flowable (Aeliteflo, Admiraflow, Permaflo, Revolution) light-curing composite resins were investigated. The degree of conversion(DC) was analyzed with Fourier transfer infra-red spectroscopy(FTIR) spectrum by a potassium bromide(KBr) pellet transmission method. The spectrum of the unpolymerized specimen had been measured before the specimen was irradiated for 60s with a visible light curing unit. The Poiymerized specimen was scanned for its in spectrum. The flexural strength(FS) was measured with 3-point bending test according to ISO 4049 after storage in water at $37^{\circ}C$ for 24 hours. The data were statistically analyzed by an independent sample t-test and one-way ANOVA at the significance level of 0.05. The dependence of flexural strength on the degree of conversion was also analyzed by regression analysis. Results. Mean DC and FS values ranged from 43% to 61% and from 84.7MPa to 156.7MPa respectively. DC values of the flowable composite resins were significantly higher than those of restorative composite resins (P < 0.05). The FS values of restorative composite resins were greater than those of flowable composite resins. No statistically significant correlation was observed between the DC and the FS tested in any of the composites. The dependence of FS on DC in restorative or flowable composite resins was not significant. Conclusion. It can be concluded that radical polymerization of the organic matrix is not a major factor in determining flexural strength of the commercially available composite resins.

인형 모의피폭체내 MOSFET 선량계의 에너지 및 방향 의존도를 고려하기 위한 선량보정인자 결정 (Determination of Dose Correction Factor for Energy and Directional Dependence of the MOSFET Dosimeter in an Anthropomorphic Phantom)

  • 조성구;최상현;나성호;김찬형
    • Journal of Radiation Protection and Research
    • /
    • 제31권2호
    • /
    • pp.97-104
    • /
    • 2006
  • 최근 방사선 치료 및 진단 분야에서 선량 측정을 위하여 다양하게 사용되고 있는 MOSFET 선량계는 검출부위가 실리콘으로 이루어져 있으며 다른 검출기들과 마찬가지로 어느 정도의 에너지 의존도와 방향 의존도를 보인다. 따라서 MOSFET 선량제가 공기 중이 아닌 모의피폭체 내에서 선량 측정에 사용될 경우 낮은 에너지를 갖는 산란 광자 등 이차 광자들로 인하여 선량을 실제보다. 높게 평가하게 된다. 본 연구에서는 MOSFET 선량계의 에너지 의존도와 방향 의존도로 인하여 발생하는 오차를 보정하기 위한 선량보정인자를 몬테카를로 전산모사 기법을 이용하여 계산하였다. 먼저 사용되는 인형 모의 피폭체의 체적소 모의피폭체(Voxel Phanom)를 CT 영상을 이용하여 제작하였으며 제작된 체적소 모의 피폭체를 몬테카를로 전산코드로 구현한 후, 모의피폭체 내 각 선량계 지점에서 입사하는 광자의 에너지 및 방향별 에너지 스펙트럼을 계산하였다. 각각의 선량계 지점에서 0.662 MeV와 1.25 MeV의 광자빔을 고려하였으며 또한 MOSFET 선량계의 방향은 실리콘 베이스 방향과 에폭시 방향을 고려하였다. 주어진 선량제 지점에서의 선량보정인자는 계산된 에너지 의존도들의 중간간을 이용하여 결정하였으며 이렇게 결정된 각 선량계 지점에서 선량보정인자는 0.89-0.97 범위의 값들을 나타내었다. 본 연구결과에 따르면 MOSFET 선량계를 이용하여 인형 모의피폭체 내에 선량을 측정할 때 에너지 의존도와 방향 의존도를 고려하지 않을 경우 측정 위치에 따라 $3{\sim}11%$ 정도의 측정오차가 발생할 수 있다. 그러므로 인형 모의피폭체 내의 선량을 정확하게 측정하기 위해서는 선량보정인자를 각 선량계에 필히 적용해주어야 한다.

열형광선량계(熱螢光線量計)의 에너지의존성(依存性) 보상(補償) (The Compensation of the Energy Dependence of TLD)

  • 박명환;이준일;권덕문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.51-60
    • /
    • 1993
  • The $CaSO_4$ : Tm-PTFE TLDs have been prepared and their energy dependences of TL intensity to X-rays have been investigated. The dose dependence of the prepared $CaSO_4$ : Tm-PTFE TLDs is linear within the range of $100{\mu}Gy-10Gy$ for X-rays and gamma rays. The spectral peaks of TL emission spectrum are at about 350nm and 475nm. The fading rate of the main peak has been found to be about 2% for 30days when $CaSO_4$ : Tm-PTFE TLDs stored in the dark room at room temperature. The energy dependence of $CaSO_4$ : Tm-PTFE TLD has been compensated by combining the TL responses of one bare TLD and five TLDs filtered with 1.0mm Al, 0.2mm Cu, 0.5mm Cu, 1.5mm Cu, 2.0mm Pb respectively. The determined correction coefficients for filter combination are $a_0=0.078,\;a_1=-0.009,\;a_2=-0.235,\;a_3=0.588,\;a_4=0.568\;and\;a_5=0.180$ respectively. From the results of these studies, the prepared TLD badge of six dosimeter combination may be useful as a radiation dosimeter for personal and environmental monitoring.

  • PDF