A study on the reduction of indoor radon contamination (실내 라돈의 오염량 감소에 관한 연구)

  • Kim, Chang-Kyun;Choi, Jong-Hak;Kang, Jeong-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.53-56
    • /
    • 2006
  • The purpose of the present study is to find ways to reduce the quantity of indoor radon contamination. The study was done from July, 2005 until December, 2005. It was found out that the easiest and most effective way to do that is to open the windows as often as possible and let the indoor air flow outside. When it is not possible to ventilate a room, the indoor radon contamination quantity can reduced by providing activated charcoal in the room. It has been proved that activated charcoal can absorb the room in the air. We need more activated charcoal in proportion to the size of the room. A further research is needed to investigate the amount of activated charcoal that will work most effectively.

  • PDF

A Study on Enacting the Radiologic Technologist Act for the Civil Right to Health in Korea (건강권과 방사선사법 제정에 관한 고찰)

  • Lim, Chang-Seon
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.313-320
    • /
    • 2007
  • There are the Medical Radiation Health and Safety Act(the Patient Radiation Health and Safety Act, the Radiologic Technologist Act), the Medical Laboratory Technologist Act, the Physical Therapy Practice Act, and the Dental Hygienist Act, etc in America. However, Korea has only one Act for a medical radiologic technologist(including radiation therapy technologist, nuclear medicine technologist), medical laboratory technologist, physical therapist, occupational therapy examiner, dental hygienist, and so on. It is the Medical Technologist Act. Therefore, the Medical Radiation Health and Safety Act for a radiologic technologist(including radiation therapy technologist, nuclear medicine technologist) has to be enacted independently in Korea. It is the purpose of this Act to provide for the appropriate certification of persons using radioactive materials, equipment emitting ionizing radiation on humans or performing medical imaging for diagnostic and therapeutic purposes. In Korea, the radiologic technologist is a "fusion technologist" who is a person other than a licensed practitioner as a radiographer, radiation therapist, nuclear medicine technologist, computed tomography technologist, magnetic resonance technologist, mammographer, sonographer, medical dosimetrist, quality management technologist, etc. This Act will have some provisions related to the definitions, reserved title, scope of practice, specialized technologist, application for licensure, radiologic technology council, renewal, continuing education, the radiation control advisory commission, etc. This Act will ensure that quality radiation therapy treatments are delivered and that quality diagnostic information is presented for interpretation, which will lead to accurate diagnosis, treatment and cure. Accurate diagnosis can be provided only when a personnel is properly educated in technique, equipment operation and radiation safety. In the end, this Act will protect the civil right to health. By regulating the personnel responsible for performing those procedures, this Act will mean improved care for patients-higher quality images, improved accuracy, and less exposure to radiation.

  • PDF

Evaluation of Accuracy About 2D vs 3D Real-Time Position Management System Based on Couch Rotation when non-Coplanar Respiratory Gated Radiation Therapy (비동일평면 호흡동조방사선치료 시 테이블 회전에 따른 2D vs 3D Real-Time Position Management 시스템의 정확성 평가)

  • Kwon, Kyung-Tae;Kim, Jung-Soo;Sim, Hyun-Sun;Min, Jung-Whan;Son, Soon-Yong;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.601-606
    • /
    • 2016
  • Because of non-coplanar therapy with couch rotation in respiratory gated radiation therapy, the recognition of marker movement due to the change in the distance between the infrared camera and the marker due to the rotation of the couch is called RPM (Real-time The purpose of this paper is to evaluate the accuracy of motion reflections (baseline changes) of 2D gating configuration (two dot marker block) and 3D gating configuration (six dot marker block). The motion was measured by varying the couch angle in the clockwise and counterclockwise directions by $10^{\circ}$ in the 2D gating configuration. In the 3D gating configuration, the couch angle was changed by $10^{\circ}$ in the clockwise direction and compared with the baseline at the reference $0^{\circ}$. The reference amplitude was 1.173 to 1.165, the couch angle at $20^{\circ}$ was 1.132, and the couch angle at $1.0^{\circ}$ was 1.083. At $350^{\circ}$ counterclockwise, the reference amplitude was 1.168 to 1.157, the couch angle at $340^{\circ}$ was 1.124, and the couch angle at $330^{\circ}$ was 1.079. In this study, the phantom is used to quantitatively evaluate the value of the amplitude according to couch change.

Relationship of Admission Type, College-Life Satisfaction and College Student Academic Achievement of Radiologic Science(Technology) Students (방사선(학)과 학생들의 대학입학유형, 학업성취도, 대학생활만족도의 상관관계에 관한 연구)

  • Cho, Young-Kwon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.12
    • /
    • pp.124-131
    • /
    • 2016
  • This study was conducted to serve as a basis for education by identifying the correlation of college admission type, college-life satisfaction and academic achievement of radiologic science students. Data were collected from 2 universities and 2 colleges located in Gyeonggi Provice, North Chungcheong Province, North Gyeongsang Province. A total of 371 questionnaires were collected, 363 of which were included in this study. The results showed that there were no differences in academic achievement according to the type of college admission. It could be able to interpret that since department of radiologic science is popular, students with high academic records applies the department of radiologic science and there are less deviation of academic records among students. A correlation analysis of academic achievement showed learning attitude is a statistically valid factor. Learning attitudes can be changed by exposure to the environment. This will require a variety of program development for improving learning attitudes. In addition, academic achievement of radiologic science students is associated with license acquisition. It need to be made together research on determinants and development of learning method to improve the learning attitude.

Clinical and Radiological Characteristics in Patients with Postoperative Maxillary Cyst: A Retrospective Study

  • Hyoung-Cheol Kim;Suk-Ja Yoon;Yeong-Gwan Im;Jae-Seo Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.3
    • /
    • pp.81-86
    • /
    • 2023
  • Purpose: To evaluate the clinical and radiologic findings of the postoperative maxillary cysts (POMCs) and investigate the relationship between lesion size and clinical symptoms depending on the time elapsed after radical maxillary sinus surgery. Methods: A total of 29 patients who were diagnosed with POMCs at Chonnam National University Dental Hospital were selected. Clinical and radiologic findings were investigated. POMC cases were divided into two groups: those with <24 years between maxillary sinus surgery and POMC diagnosis and those with >24 years. The chi-square test was used to compare the differences between the two groups. Results: The average period from surgery to POMC detection was 24.32 years; however, the period could not be confirmed in four patients. The average patient age was 52.75 years, and 12 (41.3%) patients were in their 50s. POMC-related clinical symptoms were as follows: buccal pain and swelling, dull pain, toothache, abscess, sensory abnormality, and asymptomatic. Twenty (69.0%) cases showed unilocular radiolucency and 9 (31.0%) revealed multilocular radiolucency. Seven cases (35.0%) were misdiagnosed as odontogenic lesions, resulting in the delayed treatment of POMCs. No statistical significance was found between the two groups with respect to symptoms, expansion to the surrounding area, presence of secondary cysts, and mesiodistal length of cyst on cone-beam computed tomography (CBCT) images. However, the buccopalatal length of the cyst on CBCT images was significantly different between the two groups. Conclusions: The buccopalatal length of POMCs observed on CBCT images was related to the time elapsed since surgery. The lack of awareness of POMCs may lead to misdiagnosis as an odontogenic infection and delayed treatment. Therefore, dentists must recognize the clinical and radiologic features of POMCs to differentiate it from dental infections.

The Influences of Bowel Condition with Lumbar Spine BMD Measurement (요추부 골밀도 측정 시 장내 변화가 골밀도에 미치는 영향)

  • Yoon, Joon;Kim, Yun-Min;Lee, Hoo-Min;Lee, Jung Min;Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.273-278
    • /
    • 2014
  • Bone density measurement use of diagnosis of osteoporosis and it is an important indicator for treatment as well as prevention. But errors in degree of precision of BMD can be occurred by status of patient, bone densitometer and radiological technologist. Therefore the author evaluated that how BMD changes according to the condition of the patient. As Lumbar region, which could lead to substantial effects on bone density by diverse factors such as the water, food, intentional bowels. We recognized a change of bone mineral density in accordance with the height of the water tank and in the presence or absence of the gas using the Aluminum Spine Phantom. We also figured out the influence of bone mineral density by increasing the water and food into a target on the volunteers. Measured bone mineral density through Aluminum Spine Phantom had statistically significant difference accordance with increasing the height of water tank(p=0.026). There was no significant difference in BMD according to the existence of the bowl gas(p=0.587). There was no significant difference in a study of six people targeted volunteers in the presence or absence of the food(p=0.812). And also there was no significant difference according to the existence of water(p=0.618). If it is not difficult to recognize the surround of bone in measuring BMD of lumbar bone, it is not the factor which has the great effect on bone mineral density whether the test is after endoscopic examination of large intestine and patient's fast or not.

MATERIAL INVESTIGATION AND ANALYSIS USING CHARACTERISTIC X-RAY

  • Oh, Gyu-Bum;Lee, Won-Ho
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.426-433
    • /
    • 2010
  • The characteristic X-rays emitted from materials after gamma ray exposure was simulated and measured. A CdTe semiconductor detector and a $^{57}Co$ radiation source were used for energy spectroscopy. The types of materials could be identified by comparing the measured energy spectrum with the theoretical X-ray transition energy of the material. The sample composition was represented by the $K_{\alpha1}$-line (Siegbahn notations), which has the highest intensity among the characteristic X-rays of each atom. The difference between the theoretic prediction and the experimental result of K-line measurement was < 0.61% even if the characteristic X-rays from several materials were measured simultaneously. 2D images of the mixed materials were acquired with very high selectivity.

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.

The Effects of Low-Intensity Ultrasound and Laser on Healing of Bone Fracture (저강도 레이저와 초음파의 동시 적용이 골절 치유 촉진에 미치는 효과)

  • Lee, Hyun-Kee
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.331-372
    • /
    • 2003
  • The purpose of study was to evaluate effects of low-intensity ultrasound and laser on healing of bone fracture. Twenty fracture patient were selected for this study(fourteen males, six females. mean aged 44.8) fracture area was humerus, tibia, forearm bones. The obtain result are as follows. 1. The result of this study were following that pain score was significantly reduced pre intervention compared with post intervention in male(P<.001). 2. The result of this study were following that pain score was significantly reduced pre intervention compared with post intervention in female(P<.001). 1. The result of this study were following that pain score was not appeared reduced pre intervention compared with post intervention in male and female(P<.001). 4. The result of this study were following that pain score was not appeared pre intervention compared with post intervention in male between age(P<.001). 5. The result of this study were following that pain score was not appeared pre intervention compared with post intervention in female between age (P<.001). 6. The result of this study were following that radiologic score was significantly reduced pre intervention compared with post intervention in male(P<.001). 7. The result of this study were following that radiologic score was significantly reduced pre intervention compared with post intervention in female(P<.001). 8. The result of this study were following that radiologic score was not appeared reduced pre intervention compared with post intervention in male and female(P<.001). 9. The result of this study were following that radiologic score was not appeared pre intervention compared with post intervention in male between ages(P<.001). 10. The result of this study were following that radiologic score was not appeared pre intervention compared with post intervention in female between ages(P<.001). 11. The result of this study were following that healing on fracture area was observed that reduced pre intervention compared with post intervention

  • PDF

Evaluation and Analysis of Scattered Radiation Dose according to Factors in General X-ray Examination (일반엑스선영상검사의 인자에 따른 산란방사선량 평가 및 분석)

  • Dong-Kyung Jung;Myeong-Hwan Park;Jeong-Min Seo
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.13-19
    • /
    • 2024
  • Control of scattered radiation is one of very important factors in the use of medical radiation. In general X-ray exam, the causes, measurement methods, and the kind of detectors of scattered rays within the radiation area are diverse. In this study, the dose of scattered ray was measured by changing the thickness of the polycarbonate phantom and the tube voltage. As a result of measurement of scattered radiation, the results show that the scattered dose significantly(p<.05) increased with growing of thickness of phantom in the tube voltage 40, 50 and 60 kVp(F(p)<.05, R2>64%). As tube voltage increased at all phantom thicknesses, the scattered dose also significantly(p<.05) increased(F(p)<.05, R2>69%). In cases where a significant correlation was shown, the coefficient of determination of more than 60% was shown in regression analysis. The results of this study can be used as data on scattered radiation dose according to the tube voltage and the object thickness in general X-ray imaging exam.