Visualization of the Origin of the Vertebral Arteries with Color Doppler Sonography (색도플러 초음파검사에 의한 경추골동맥 기시부 관찰)

  • Yoon, Seok-Hwan;Lee, Won-Hong;Lee, Dae-Hyung
    • Journal of radiological science and technology
    • /
    • 제32권1호
    • /
    • pp.87-93
    • /
    • 2009
  • Background/aim : Atherosclerotic disease at the origin of the vertebral arteries is one of the risk factors for vertebrobasilar ischemic disease. Assessment and visualization of the origin of the vertebral arteries with color doppler sonography is a non-trivial task. The aim of this study is to increase the visualization rate of the origin of the vertebral arteries with color doppler sonography. Materials and Methods : Color doppler sonography for the vertebral arteries included carotid arteries was performed to 198 patients. We first examined the vertebral artery in the upper neck in the direction of the subclavian artery to distinguish its origin more easily. If the vertebral artery origin was not visualized in natural position, the examiner pushed the transducer toward a clavicle or pushed the shoulder of patient by the other hand. The technical methods for visualization of the vertebral artery origin were classified into three grades: natural position, pushing the transducer, and pushing the shoulder of patient according to the depth (3.0 cm and shallower, deeper than 3.0 cm) of the origin. Results : The origin of the vertebral arteries could be visualized in 97% on the right and in 92% on the left. The origin of the vertebral arteries could be visualized in 98.6%, 1.4%, and 0.0% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 81.2%, 14.6%, and 4.2% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 85.4%, 10.7%, and 3.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the left side. The origin of the vertebral arteries could be visualized in 55.7%, 30.4%, and 13.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the left side. Conclusion : If the examiner pushes the transducer toward a clavicle or pushes the shoulder of patient by the other hand, when the vertebral artery origin during the color doppler sonography is not visualized in natural position, visualization rate of the origin of the both vertebral arteries is increased.

  • PDF

Performance Measurement of Diagnostic X Ray System (진단용 X선 발생장치의 성능 측정)

  • You, Ingyu;Lim, Cheonghwan;Lee, Sangho;Lee, Mankoo
    • Journal of the Korean Society of Radiology
    • /
    • 제6권6호
    • /
    • pp.447-454
    • /
    • 2012
  • To examine the performance of a diagnostic X-ray system, we tested a linearity, reproducibility, and Half Value Layer(HVL). The linearity was examined 4 times of irradiation with a given condition, and we recorded a level of radiation. We then calculated the mR/mAs. And the measured value should not be more than 0.1. If the measured value was more than 0.1, we could know that the linearity was decreased. The reproducibility was analyzed 10 times of irradiations at 80kVp, 200mA, 20mAs and 120kVp, 300mA, 8mAs. The values from these analyses were integrated into CV equation, and we could get outputs. The reproducibility was good if the output was lower than 0.05. HVL was measured 3 times of irradiation without a filter, and we inserted additional HLV filters with 0, 1, 2, 4 mm of thickness. We tested the values until we get the measured value less than a half of the value measured without additional filter. We tested the linearity, the reproducibility, and HVL of 5 diagnostic X-ray generators in this facilities. The linearity of No. 1 and No. 5 generator didn't satisfy the standard for radiation safety around 300mA~400mA and 100mA~200mA, respectively. HVL of No.1 generator was not satisfied at 80kVp. The outputs were higher in the three-phase equipment than the single-phase equipment. The old generators need to maintain and exchange of components based on the these results. Then, we could contribute to getting more exact diagnosis increasing a quality of the image and decreasing an expose dose of radiation.

A Review of Personal Radiation Dose per Radiological Technologists Working at General Hospitals (전국 종합병원 방사선사의 개인피폭선량에 대한 고찰)

  • Jung, Hong-Ryang;Lim, Cheong-Hwan;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • 제28권2호
    • /
    • pp.137-144
    • /
    • 2005
  • To find the personal radiation dose of radiological technologists, a survey was conducted to 623 radiological technologists who had been working at 44 general hospitals in Korea's 16 cities and provinces from 1998 to 2002. A total of 2,624 cases about personal radiological dose that were collected were analyzed by region, year and hospital, the results of which look as follows : 1. The average radiation dose per capita by region and year for the 5 years was 1.61 mSv. By region, Daegu showed the highest amount 4.74 mSv, followed by Gangwon 4.65 mSv and Gyeonggi 2.15 mSv. The lowest amount was recorded in Chungbuk 0.91 mSv, Jeju 0.94 mSv and Busan 0.97 mSv in order. By year, 2000 appeared to be the year showing the highest amount of radiation dose 1.80 mSv, followed by 2002 1.77 mSv, 1999 1.55 mSv, 2001 1.50 mSv and 1998 1.36 mSv. 2. In 1998, Gangwon featured the highest amount of radiological dose per capita 3.28 mSv, followed by Gwangju 2.51 mSv and Daejeon 2.25 mSv, while Jeju 0.86mSv and Chungbuk 0.85 mSv belonged to the area where the radiation dose remained less than 1.0 mSv In 1999, Gangwon also topped the list with 5.67 mSv, followed by Daegu with 4.35 mSv and Gyeonggi with 2.48 mSv. In the same year, the radiation dose was kept below 1.0 mSv. in Ulsan 0.98 mSv, Gyeongbuk 0.95 mSv and Jeju 0.91 mSv. 3. In 2000, Gangwon was again at the top of the list with 5.73 mSv. Ulsan turned out to have less than 1.0 mSv of radiation dose in the years 1998 and 1999 consecutively, whereas the amount increased relatively high to 5.20 mSv. Chungbuk remained below the level of 1.0 mSv with 0.79 mSv. 4. In 2001, Daegu recorded the highest amount of radiation dose among those ever analyzed for 5 years with 9.05 mSv, followed by Gangwon with 4.01 mSv. The area with less than 1.0 mSv included Gyeongbuk 0.99 mSv and Jeonbuk 0.92 mSv. In 2002, Gangwon also led the list with 4.65 mSv while Incheon 0.88 mSv, Jeonbuk 0.96 mSv and Jeju 0.68 mSv belonged to the regions with less than 1.0 mSv of radiation dose. 5. By hospital, KMH in Daegu showed the record high amount of average radiation dose during the period of 5 years 6.82 mSv, followed by GAH 5.88 mSv in Gangwon and CAH 3.66 mSv in Seoul. YSH in Jeonnam 0.36 mSv comes first in the order of the hospitals with least amount of radiation dose, followed by GNH in Gyeongnam 0.39 mSv and DKH in Chungnam 0.51 mSv. There is a limit to the present study in that a focus is laid on the radiological technologists who are working at the 3rd referral hospitals which are regarded to be stable in terms of working conditions while radiological technologists who are working at small-sized hospitals are excluded from the survey. Besides, there are also cases in which hospitals with less than 5 years since establishment are included in the survey and the radiological technologists who have worked for less than 5 years at a hospital are also put to survey. We can't exclude the possibility, either, of assumption that the difference of personal average radiological dose by region, hospital and year might be ascribed to the different working conditions and facilities by medical institutions. It seems therefore desirable to develop standardized instruments to measure working environment objectively and to invent device to compare and analyze them by region and hospital more accurately in the future.

  • PDF

Analysis of Influencing Factors Related to Health Promotion Behavior in Hospital Radiological Technologists (종합병원 방사선사의 건강증진행위 관련요인 분석)

  • Ko, Jong-Kyung;Kwon, Duk-Mun;Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • 제32권4호
    • /
    • pp.381-391
    • /
    • 2009
  • Purposes : The purpose of this study was to analyze factors that could affect health of radiological technologists, which is useful for health care and development of programs for health promotion. Methods : Subjects were 234 of radiological technologists who work in general hospitals. Some questionnaires were made about perceptions of health condition and promotional behavior of health for this study. The questionnaires of health perception were 20 items that consist of the present condition of health, health concern and sensitivity. The reliability was sufficient(Cronbach's $\alpha=0.79$). The other questionnaires about health promotion behavior were 47 items that consist of self-realization, health responsibility, exercise, nutrition, personal relationships, and stress management. The results turned out to bewas sufficient (Cronbach's $\alpha=0.93$). Every data was treated statistically, comparison of average(t-test, ANOVA), correlation, and multiple regression. Results : Related factors to health promotion behavior were age, marriage, salary, class of one's position, career, employment, and religion, in general features. In health life habit, related factors were smoke and exercise. Results of health promotion behavior was 2.90 of mean score, 0.37 of standard deviation. Correlations between factors of health perception and health promotion behavior was positive(p<0.01). Health promotion behavior were affected by sensitivity, presents condition of health, exercise, smoke, career. Sensitivity was the most affectable variable, which means that promotional behavior score became higher and higher as the score of sensitivity and present condition were increased. In addition, persons who exercise regularly, had been smoked, and has higher career showed higher score of promotional behavior. Conclusion : Radiological technologists have to keep their health, trying not to infected by a disease. Most of all, no smoking and regular exercise are the most important thing to all of members.

  • PDF

Position Uncertainty due to Multi-scattering in the Scintillator Array of Dual Collimation Camera (복합 집속 카메라의 섬광체배열에서 다중산란에 의한 위치 불확실성)

  • Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • 제31권3호
    • /
    • pp.287-292
    • /
    • 2008
  • Position information of radiation interactions in detection material is essential to reconstruct a radiation source image. With most position sensing techniques, the position information of a single interaction inside the detectors can be precisely obtained. Each interaction position of multi-scattering inside scintillators, however, can not be individually measured and only the average of the scattering positions can be obtained, which causes the uncertainty in the measured interaction position. In this paper, the position uncertainties due to the multi-scattering were calculated by Monte Carlo simulation. The simulation model was a 50 by 50 by 5 mm $LaCl_3$(Ce) scintillator(pixel size is 2 by 2 by 5mm) which was utilized for the dual collimation camera. The dual collimation camera uses the information from both photoelectric effect and Compton scattering, and therefore, position uncertainties for both partial and full energy deposition of radiation interactions are calculated. In the case of partial energy deposition(PED), the standard deviations of positions are less than $1{\sim}2mm$, which means the uncertainty caused by multi-scattering is not significant. Because the effect of the multi-scattering with PED is insignificant, the multi-scattering has little effect on the performance of Compton imaging of dual collimation camera. In the case of full energy deposition(FED), however, the standard deviation of the positions is about twice that of the pixel size of the 1stdetector, except for 122keV incident radiations. Therefore, the standard deviations caused by multi-scatterings should be considered in the design of the coded mask of the dual collimation camera to avoid artifact on the reconstructed image. The position uncertainties of the FEDs are much larger than those of the PEDs for all radiation energies and the ratio of PEDs to FEDs increases when the incident radiation energy increases. The position uncertainties of both PEDs and FEDs are dependent on the incident radiation energy.

  • PDF

Comparison of Image Quality among Different Computed Tomography Algorithms for Metal Artifact Reduction (금속 인공물 감소를 위한 CT 알고리즘 적용에 따른 영상 화질 비교)

  • Gui-Chul Lee;Young-Joon Park;Joo-Wan Hong
    • Journal of the Korean Society of Radiology
    • /
    • 제17권4호
    • /
    • pp.541-549
    • /
    • 2023
  • The aim of this study wasto conduct a quantitative analysis of CT image quality according to an algorithm designed to reduce metal artifacts induced by metal components. Ten baseline images were obtained with the standard filtered back-projection algorithm using spectral detector-based CT and CT ACR 464 phantom, and ten images were also obtained on the identical phantom with the standard filtered back-projection algorithm after inducing metal artifacts. After applying the to raw data from images with metal artifacts, ten additional images for each were obtained by applying the virtual monoenergetic algorithm. Regions of interest were set for polyethylene, bone, acrylic, air, and water located in the CT ACR 464 phantom module 1 to conduct compare the Hounsfield units for each algorithm. The algorithms were individually analyzed using root mean square error, mean absolute error, signal-to-noise ratio, peak signal-to-noise ratio, and structural similarity index to assess the overall image quality. When the Hounsfield units of each algorithm were compared, a significant difference was found between the images with different algorithms (p < .05), and large changes were observed in images using the virtual monoenergetic algorithm in all regions of interest except acrylic. Image quality analysis indices revealed that images with the metal artifact reduction algorithm had the highest resolution, but the structural similarity index was highest for images with the metal artifact reduction algorithm followed by an additional virtual monoenergetic algorithm. In terms of CT images, the metal artifact reduction algorithm was shown to be more effective than the monoenergetic algorithm at reducing metal artifacts, but to obtain quality CT images, it will be important to ascertain the advantages and differences in image qualities of the algorithms, and to apply them effectively.

Ultrasonographic Findings of Papillary Carcinoma of the Thyroid According to the Size : Especially Less Than 0.5 cm (갑상선 유두암의 크기에 따른 초음파 특징 분류)

  • Park, So-Yung;Kim, Yun-Min;Lee, Hyun-Bok;Cho, Nam-Soo;Yoon, Joon
    • Journal of radiological science and technology
    • /
    • 제36권2호
    • /
    • pp.149-155
    • /
    • 2013
  • The Korean Thyroid Association recommends fine-needle aspiration biopsy (FNAB) for nodules more than 0.5 cm in diameter. But nodules, smaller than 0.5 cm have been found in papillary carcinomas of the thyroid (PTC) at the health promotion center at SMC. We wanted to evaluate the ultrasonographic findings according to size of nodule in proven PTCs by FNAB, especially less than 0.5 cm. All nodules were classified into three groups by their longest diameter : less than 0.5 cm, more than 0.5 cm but less than 1 cm, and more than 1 cm. Sonographic findings suggesting malignancy were analyzed according to their size groups. Of 288 malignant nodules, 21.5 % (62/288) were less than 0.5 cm, 54.9 % (158/288) were more than 0.5 cm but less than 1 cm, 23.6 % (68/288) exceeded 1 cm. A taller-than-wide shape was observed in 90.3 % (56/62) of nodules less than 0.5 cm, and 48.5 % (33/68) of nodules exceeding 1 cm (p<0.001). There were no well-defined smooth nodules among nodules less than 0.5 cm, and spiculated or irregular margin nodules increased as the size increased (p=0.024). Nodules of size less than 0.5 cm did not showed hyper or isoechogenicity. Hypoechogenicity was greater than the marked hypoechogenicity in each group (p=0.034). Micro- or macro-calcifications were not founded in 77.4 % (48/62) of the nodule group sized less than 0.5 cm. From the small size of the group, micro- or macrocalcifications were observed 21.0 % (13/62), 48.1 % (76/158), 64.7 % (44/68), so the number of nodules containing micro- or macro-calcification increased as size increased (p<0.001). PTCs less than 0.5 cm in size on ultrasonography had taller than-wide shape, spiculated or irregular and ill-defined margins, and exhibited hypo and markedly hypoechogenicity, but microor macro-calcifications were not common. These ultrasonographic features of nodules less than 0.5 cm can be useful in reporting and guiding FNABs or follow-up exams.

Radiation Exposure Dose on Persons Engaged in Radiation-related Industries in Korea (한국에서 방사선 관련 종사자들의 개인피폭선량 실태에 관한 연구)

  • Lim, Bong-Sik
    • Journal of radiological science and technology
    • /
    • 제29권3호
    • /
    • pp.185-195
    • /
    • 2006
  • Purpose: This study investigated the status of radiation exposure doses since the establishment of the "Regulations on Safety Management of Diagnostic Radiation Generation Device" in January 6, 1995. Method: The level of radiation exposure in people engaged or having been engaged in radiation-related industries of inspection organizations, educational organizations, military units, hospitals, public health centers, businesses, research organizations or clinics over a 5 year period from Jan. 1, 2000 to Dec. 31, 2004 was measured. The 149,205 measurement data of 57,136 workers registered in a measurement organization were analysed in this study. Frequency analysis, a Chi-square test, Chi-square trend test, and ANOVA was used for data analysis. Results: Among 57,136, men were 40,870(71.5%). 50.3% of them were radiologic technologists, otherwise medical doctors(22.7%), nurse(2.9%) and others(24.1%). The average of depth radiation and surface radiation during the 5-year period were found to decrease each year. Both the depth radiation and surface radiation exposure were significantly higher in males, in older age groups, in radiological technologists of occupation. The departments of nuclear medicine had the highest exposure of both depth and surface radiation of the divisions of labor. There were 1.98 and 2.57 per 1,000 person-year were exposed more than 20 mSv(limit recommended by International Commission on Radiological Protection) in depth and surface radiation consequently. Conclusion: The total exposure per worker was siginifcantly decreased by year. But Careful awareness is needed for the workers who exposed over 20 mSv per year. In order to minimize exposure to radiation, each person engaged in a radiation-related industry must adhere to the individual safety management guidelines more thoroughly. In addition, systematic education and continuous guidance aimed at increasing the awareness of safety must be provided.

  • PDF

Analysis of $^{99m}Tc-ECD$ Brain SPECT images in Boys and Girls ADHD using Statistical Parametric Mapping(SPM) (통계적 파라미터지도 작성법(SPM)을 이용한 남여별 ADHD환자의 뇌 SPECT 영상비교분석)

  • Park, Soung-Ock;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • 제27권3호
    • /
    • pp.31-41
    • /
    • 2004
  • Attention deficit hyperactivity disorder(ADHD)is one of the most common psychiatric disorders in childhood, especially school age children and persisting into adult. ADHD is affected 7.6% in our children, Korea. and persisting into $15{\sim}20%$ in adult. And it is characterized by hyperactivity, inattention and impulsivity. Brain imaging is one of way to diagnosis for ADHD. Brain imaging studies may be provide information two types - structural and functional imaging. Structural and functional images of the brain play an important role in management of neurologic and psyciatric disorders. Brain SPECT, with perfusion imaging radiopharmaceuticals is one of the appropriate test to diagnosis of neurologic and psychiatric diseases. Ther are a few studies about separated analysis between boys and girls ADHD SPECT brain images. Selection of Probability level(P-value) is very important to determind the abnormalities when analysis a data by SPM. SPM is a statistical method used for image analysis and determine statistical different between two groups-normal and ADHD. Commonly used P-value is P<0.05 in statistical analysis. The purpose of this study is to evaluation of blood flow clusters distribution, between boys and girls ADHD. The number of normal boys are 8(6-7y, average : $9.6{\pm}3.9y$) and 51(4-11y, average : $9.0{\pm}2.4$) ADHD patients, and normal girls are 4(6-12y, average : $9{\pm}2.4y$) and 13(2-13y, average $10{\pm}3.5y$) ADHD patiens. Blood flow tracer $^{99m}Tc-ethylcysteinate$ dimer(ECD) injected as rCBF agent and take blood flow images after 30 min. during sleeping by SPECT camera. The anatomical region of hyperperfusion of rCBF in boys ADHD group is posterior cingulate gyrus and hyperperfusion rate is 15.39-15.77% according to p-value. And girls ADHD group appears at posterior cerebellum, Lt. cerbral limbic lobe and Lt. Rt. cerebral temporal lobe. These areas hyperperfusion rate are 24.68-31.25%. Hypoperfusion areas in boys ADHD,s brain are Lt. cerebral insular gyrus, Lt. Rt. frontal lobe and mid-prefrontal lobe, these areas decresed blood flow as 15.21-15.64%. Girls ADHD decreased blood flow regions are Lt. cerebral insular gyrus, Lt. cerebral frontal and temporal lobe, Lt. Rt. lentiform nucleus and Lt. parietal lobe. And hypoperfusion rate is 30.57-30.85% in girls ADHD. The girls ADHD group's perfusion rate is more variable than boys. The studies about rCBF in ADHD, should be separate with boys and girls.

  • PDF

Development of Rabbit Brain Tumor Model Using VX2 Cells and Verification with the MRI in Neuroradiologic Research (Neuroradiology 연구를 위한 VX2 세포를 이용한 토끼 뇌종양 모델 제작과 MRI를 이용한 검증)

  • Yong-Woo Kim;Seon Hee Choi;Hak Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • 제84권2호
    • /
    • pp.441-453
    • /
    • 2023
  • Purpose To evaluate the development, location, and volume of a VX2 carcinoma using four inoculation methods in a rabbit brain. Materials and Methods Inoculation of a VX2 cell suspension was performed 1) on the appointed day, 2) seven days after storing a VX2 carcinoma in a freezer or 3) seven days after storing a VX2 carcinoma in a deep freezer after sacrificing the donor rabbits. 4) Without sacrificing the rabbits, the VX2 cell suspension was obtained using a gun biopsy, inoculation was performed on the appointed day. MR imaging was performed 10 days after inoculation. Brain tissues were obtained the day after. The development, location, and volume of the tumor were evaluated. Results Seventeen of the 18 rabbits inoculated on the appointed day developed tumors (average tumor volume, 106.32 mm3). One of five inoculated seven days after storing the VX2 tumor in the freezer, and three of five inoculated seven days after storing the VX2 tumor in the deep freezer developed tumors. Inoculation with a VX2 cell suspension obtained with a gun biopsy from five rabbits revealed development of tumors in only two rabbits. The tumors mostly developed in the superficial cortex. Conclusion TVX2 rabbit brain tumor model is easy to develop and revealed variable reproducibility. This model can be applicable in radiologic imaging, treatment planning, interventional treatment and drug delivery research. VX2 cell can be successfully innoculated into the brain using variable methods under researcher's variable conditions.