• Title/Summary/Keyword: Department of Radiography

Search Result 1,485, Processing Time 0.032 seconds

Clinical application of panoramic radiography With multi-layer imaging software : Case reports (Multi-layer image 소프트웨어를 사용한 파노라마방사선영상의 임상적 활용 : 증례보고)

  • Jeon, Kug Jin;Kim, Jae Hun;Lee, Jeong-Hee;Kim, Young Hyun;Han, Sang-Sun
    • The Journal of the Korean dental association
    • /
    • v.57 no.1
    • /
    • pp.26-33
    • /
    • 2018
  • Panoramic radiography is widely used as a primary radiological diagnosis in dentistry. However, due to the overlapping of anatomical structures, diagnostic capability of panoramic radiography is limited. Recently, panoramic machine equipped with various image processing software has been introduced to improve the diagnostic capability. This study aims to introduce panoramic equipment with multi-layer imaging software that can provide 41 images from anterior to posterior in region of interest, and to report in various clinical applications.

  • PDF

Derivation of External Exposure Characteristics of Industrial Radiography Based on Empirical Evidence

  • Cho, Junik;Kim, Euidam;Kwon, Tae-Eun;Chung, Yoonsun
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.2
    • /
    • pp.93-98
    • /
    • 2022
  • Background: This study aims to derive the characteristics of each work type for industrial radiography based on empirical evidence through expert advice and a survey of radiation workers of various types of industrial radiography. Materials and Methods: According to a Korean report, work types of industrial radiography are classified into indoor tests, underground pipe tests, tests in a shielded room (radiographic testing [RT] room test), outdoor field tests, and outdoor large structure tests. For each work type, exposure geometry and radiation sources were mainly identified through the expert advice and workers' survey as reliable empirical evidence. Results and Discussion: The expert advice and survey results were consistent as the proportion of the work types were high in the order of RT room test, outdoor large structure test, underground pipe test, outdoor field test, and indoor test. The outdoor large structure test is the highest exposure risk work type in the industrial radiography. In most types of industrial radiography, radiation workers generally used 192Ir as the main source. In the results of the survey, the portion of sources was high in the order of 192Ir, X-ray generator, 60Co, and 75Se. As the exposure geometry, the antero-posterior geometry is dominant, and the rotational and isotropic geometry should be also considered with the work type. Conclusion: In this study, through expert advice and a survey, the external exposure characteristics for each work type of industrial radiography workers were derived. This information will be used in the reconstruction of organ dose for health effects assessment of Korean radiation workers.

Comparison of Waters′ radiography, panoramic radiography, and computed tomography in the diagnosis of antral mucosal thickening (상악동의 점막비후에 대한 WATERS방사선사진과 파노라마방사선사진 및 전산화단층사진의 진단능 비교)

  • Hyun Young-Min;Lee Sam-Sun;Choi Soon-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.261-269
    • /
    • 1998
  • With the CT findings as gold standard, the sensitivity, the specificity, and the diagnostic accuracy of Waters' radiography and Waters' radiography with panoramic radiography were compared in the diagnosis of antral mucosal thickening of 16 patients. Three oral radiologists and three non-oral radiologists interpreted the Waters' radiographs and after 4 weeks, interpreted the Waters' radiographs and panoramic radiographs simultaneously. The interpretation point was the existence or the non-existence of the mucosal thickening on the medial, the posterolateral, the floor, and the roof of maxillary sinus. The obtained results were as followed : 1. In oral radiologist group, the sensitivity, specificity and diagnostic accuracy of Waters' film were 0.7250, 0.8489 and 0.7578 respectively. 2. The sensitivity and the diagnostic accuracy in oral radiologist group were higher than those of non-oral radiologist group (P<0.05), but there was no significant difference between two groups in the specificity (P>0.05), 3. There was no significant difference of the diagnostic abilities except the specificity in oral radiologist group between Waters' radiography and Waters' radiography with panoramic radiography (P>0.05). 4. The sensitivity and the diagnostic accuracy were the highest in the case of medial wall interpretation, the specificity was the highest in the posterolateral wall. 5. In the posterolateral wall and the floor, the sensitivity and the diagnostic accuracy of oral radiologist group were higher than those of non-oral radiologist group (P<0.05).

  • PDF

The Clinical Value about Pulmonary Tuberculosis of Indirect Chest Radiography in Physical Examination for Conscription (징병 신체 검사시 집단 흉부 간접 방사선 촬영의 폐결핵 관련한 진단적 유용성)

  • Park, Sung Bin;Choi, Byeong-Kyoo;Ha, Keun Woo;Seo, Joon Beom
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.356-360
    • /
    • 2005
  • Background : This study examined the clinical utility of using indirect chest radiography during a physical examination of new conscripts for determine the presence of pulmonary tuberculosis. Methods : Over an eight-month period, this study examined 25386 people who underwent a physical examination after conscription. The abnormal findings on mass miniature radiography were followed-up using direct chest radiography. The positive predictive value of mass miniature radiography and direct chest radiography was compared. The incidence, degree of infiltration and clinical outcome of active pulmonary tuberculosis were also evaluated during a follow-up examination. Results : The positive rate of mass miniature radiography was 1.19% (n=302). Various lesions were identified: Parenchymal lesions (n=109), mediastinal lesions (n=6), cardiovascular lesions (n=45), pleural lesions (n=49), bony lesions (n=90) and miscellaneous lesions (n=7). The incidence of active pulmonary tuberculosis by mass miniature radiography was 0.26% (n=67). The first diagnosis was made in 50 people; active pulmonary tuberculosis (n=42), pneumonia (n=1), a mediastinal mass (n=1), a rib fracture (n=2) and a pneumothorax (n=4). Most cases of active pulmonary tuberculosis were mildly infiltrated and either improved or were cured by the follow-up examination. Conclusion : Although mass miniature radiography in a physical examination after conscription has limitations, but it is a useful means for detecting the presence of early disease, particularly in active pulmonary tuberculosis.

ESTIMATION OF ABSORBED DOSE IN OCCLUSAL RADIOGRAPHY (교합방사선사진 촬영시의 흡수선량 계측)

  • Yoo Young Ah;Choi Karp Shik;Lee Sang Han
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.103-112
    • /
    • 1990
  • The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-2l0 Head & Neck Section/sup R/, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70Kvp and 15mA, 1/4 second (8 inch cone) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  • PDF

Consideration of Imaging Studies for Degenerative Spine Disease (퇴행성 요추질환 영상의 고찰)

  • Sin, Jung-Sub;Kim, Jae-Hun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.1
    • /
    • pp.93-99
    • /
    • 2007
  • Purpose : The aim of this study is to consider degenerative spine disease theoretically and compare plain radiography which is a basic study for low back pain with MRI in cases of degenerative lumbar spine disease to find out whether the abnormalities agree with each other. Methods : In 4 cases of lumbar degenerative disease, we studied the relation of the abnormalities such as disc space narrowing, spinal space narrowing, loss of lordosis and osteophytes on plain radiography with those on MRI of HIVD, spinal stenosis and spondylolisthesis. Results : Many abnormalities such as disc space narrowing, spinal space narrowing, loss of lordosis, osteophytes and change of cortex & bone marrow on plain radiography suggest HIVD, spinal stenosis, spondylolysis or spondylolisthesis on MRI. Conclusion : For low back pain patients, plain radiography is a basic study in diagnosis of HIVD, spinal stenosis, spondylolysis or spondylolisthesis but MRI or CT scan is necessary to develop(build) a treatment plan like an operation.

  • PDF

An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography

  • Kim, Hyun Jin;Kim, Hyun Nam;Raza, Hamid Saeed;Park, Han Beom;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.799-804
    • /
    • 2016
  • A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

A Literature Review and Analysis of Dosimetry in Panoramic Radiography (파노라마 촬영의 피폭선량에 관한 문헌분석 연구)

  • Kweon, Dae-Cheol;Dong, Kyung-Rae;Jung, Jae-Eun;Lee, Kyeong-Hee;Kim, Soo-Kyung;Kim, Wook-Tae;Lee, Cheong-Jae;Song, Woon-Heung;Ma, Sang-Chull
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Dental panoramic radiography is an imaging technique which shows the information of teeth, jaws and superficial structures on a single image. In this study, we propose the clinical dose reference for dental panoramic radiography. Dental panoramic radiography is an application which can increase the radiation does of oral cavity. It is very important to study the real condition of management for these panoramic X-ray equipments. Since there was no researches on dental panoramic equipments in domestic and foreign study groups, we measured and analyzed the dose such as effective dose, DAP and DWP of panoramic radiography.

Radiologic study of intraosseous path of the inferior alveolar cantal, mental canal, and mental foramen for endosseous implants (인공치아 매식술을 위한 하악관, 이관, 이공의 골내 주행에 관한 방사선학적 연구)

  • Hong, So-Mi;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.4
    • /
    • pp.933-948
    • /
    • 1996
  • The purpose of this study was to examine the anatomic structures of the mandible-inferior alveolar canal, mental foramen, mental canal-with panoramic radiography and conventional tomography and to compare both radiographic techniques in conjunction with endosseous implants. In this study 14 adult dentulous mandibles -27 cases of right and left side of mandibles- were examined and the results were as follows. 1. The distance between superior border of the inferior alveolar canal and the alveolar ridge crest showed a decreasing tendency from the mental foramen to 4cm posterior to the mental foramen. 2. The mean diameter of the inferior alveolar canal was $4.11{\pm}0.50mm$ with panoramic radiography and $3.29{\pm}0.59mm$ with conventional tomography. 3. The inferior border of the inferior alveolar canal and inferior border of the mandible was closest at 2cm posterior to the mental foramen but it was not statistically significant. the mean distance was $1l.64{\pm}2.95mm$ in panoramic radiography and $1l.68{\pm} 2.91mm$ in conventional tomography. 4. The inferior alveolar canal located lingually in bucco-lingual direction 16%(mental foramen), 54%(lcm posterior to the mental foramen), 68%(2cm posterior to the mental foramen), 50%(3cm posterior to mental foramen), 55%(4cm posterior to the mental foramen). 5. Mean length of the anterior loop of the mental canal was 2.73mm, and the loop below 2mm was 35% and 15% of mental canal was invisible in panoramic radiography. 6. The minimum interforaminal distance was 56.7mm, the maximum distance was 73.2mm and the mean distance was 66.42mm in panoramic radiography. 7. The mean distance between midpoint of the mental canal and alveolar ridge crest was 16.24mm and the mean buccolingual angulation of the mental canal was $52.98^{\circ}$ in conventional tomography. 8. In comparison of panoramic radiography and conventional tomography, inferior alveolar canal is better visualized with conventional tomography than panoramic radiography from the mental foramen to the 2cm posterior to the mental foramen, while visiblity of conventional tomography prominently decreased in 4cm posterior to the mental foramen and alveolar ridge crest is better visualized with panoramic radiography than conventional radiography at the mental foramen and at 4cm posterior to the mental foramen. In radiologic examination of anatomic structures of the mandible for endosseous implants, panoramic radiography and conventional tomography can be effectively used when it is used to overcome the anatomic limitations.

  • PDF

Comparison of cone-beam computed tomography and panoramic radiography in the evaluation of maxillary sinus pathology related to maxillary posterior teeth: Do apical lesions increase the risk of maxillary sinus pathology?

  • Terlemez, Arslan;Tassoker, Melek;Kizilcakaya, Makbule;Gulec, Melike
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.115-122
    • /
    • 2019
  • Purpose: The aims of this study were first, to compare panoramic radiography with cone-beam computed tomography (CBCT) for evaluating topographic relationships, such as the classification of maxillary posterior teeth and their distance to the maxillary sinus floor; and second, to determine the relationship between maxillary sinus pathology and the presence of apical lesions. Materials and Methods: In total, 285 paired CBCT and panoramic radiography records of patients (570 maxillary sinuses) were retrospectively analyzed. Both imaging modalities were used to determine the topographic relationship of the maxillary posterior teeth to the sinus floor. Mucosal thickening >2 mm was considered a pathological state. Data were analyzed using the chi-square, Wilcoxon, and Mann-Whitney U tests. Odds ratios (ORs) and confidence intervals(CIs) were calculated. Results: The closest vertical distance measurements made between posterior maxillary teeth roots and the maxillary sinus on panoramic radiography and CBCT scans showed statistically significant differences from each other(P<0.05). Compared to panoramic radiography, CBCT showed higher mean values for the distance between the maxillary sinus floor and maxillary posterior teeth roots. The CBCT images showed that at least 1 apical lesion adjacent to the right maxillary sinus increased the risk of maxillary sinus pathology by 2.37 times(OR, 2.37; 95% CI, 1.58-3.55, P<0.05). Conclusion: Panoramic radiography might lead to unreliable diagnoses when evaluating the distance between the sinus floor and posterior roots of the maxillary teeth. Periapical lesions anatomically associated with maxillary sinuses were a risk factor for sinus mucosal thickening.