• 제목/요약/키워드: Dentin shear bonding strength

검색결과 124건 처리시간 0.032초

Ormocer-Based-Resin의 상아질에 대한 전단결합강도 및 파절 양상에 대한 연구 (Shear bond strength and fracture patterns between Ormocer-based-resin and dentin)

  • 안시현;조인호;임주환;임헌송
    • 구강회복응용과학지
    • /
    • 제18권4호
    • /
    • pp.289-299
    • /
    • 2002
  • The bond strength is one of the most important factor in establishing long-term success of esthetic restorative dentistry. So, various restorative materials have been introduced to improve the esthetic and physical properties. Ormocer (organically modified ceramic) was developed as a result of such efforts. This study was performed to compare the shear bond strength of ormocer based adhesive with that of existing dentin adhesive. In this study $Admira^{(R)}$ and $Admira^{(R)}$ bond of the ormocer system are grouped together for ADM, Single $Bond^{(R)}$ which is an one-bottle adhesive and Z-250TM which is hybrid composite resin of BIS-GMA system for SIN, and $Definite^{(R)}$ of ormocer and Etch & $Prime^{(R)}$ 3.0 which is a self etching priming/ bonding agent for ETC. The results of this study were as follows. : (1) In the comparison of shear bond strength according to different adhesive system, shear bond strength was increased in the order of ETC group, SIN group, ADM group. There was no significant difference between ADM group and SIN group. However, there was a significant level of difference between ADM and ETC groups as well as SIN and ETC groups( p<0.05). (2) Examination by a scanning electron microscope showed a well established hybrid layer and resin tag in both ADM group and SIN group, while ETC group showed a minimal formation of the hybrid layer when compared with ADM and SIN groups. From the above results, it may be reasonable to start the clinical application of ormocer system, and it is recommended that ormocer system should be used along with an ormocer based adhesive because ormocer system showed the lower shear bond strength when it used with other existing self etching priming/bonding agent. The self etching priming/bonding agent showed relatively low shear bond strength, and it is considered that the further study should be needed.

Potential of Erythrosine-Mediated Photodynamic Therapy as a Cavity Disinfectant: Antibacterial Efficacy and Bonding Ability

  • Gawon Lee;Haeni Kim;Siyoung Lee;Juhyun Lee
    • 대한소아치과학회지
    • /
    • 제51권3호
    • /
    • pp.290-298
    • /
    • 2024
  • This study aimed to evaluate the antibacterial efficacy of erythrosine-mediated photodynamic therapy (PDT) against Streptococcus mutans (S. mutans) in dentin and its effect on the shear bond strength (SBS) of composite resin to dentin. Eighty extracted human noncarious premolars were used in this study. Forty teeth were used for the antibacterial activity test, while the remaining 40 were used for the SBS test. Both experiments were conducted with 4 experimental groups (n = 10): control (distilled water), sodium hypochlorite (NaOCl, 6%), chlorhexidine (CHX, 0.12%), and erythrosine-mediated PDT. Antibacterial effects were evaluated by counting S. mutans colony-forming units (CFUs). The SBS of composite resins to dentin was measured using a universal testing machine. All treatments (NaOCl, CHX, and PDT) demonstrated statistically significant differences in antibacterial activity compared with the control group (p < 0.05). The antibacterial effects were ranked from strongest to weakest as follows: NaOCl, PDT, and CHX. In the SBS test, the NaOCl group exhibited a statistically significant difference compared with the CHX, PDT, and control groups (p < 0.05), with the lowest bond strength. No statistically significant differences were found among the CHX, PDT, and control groups (p > 0.05). Erythrosine-mediated PDT exhibited significant antibacterial effects against S. mutans, with higher antibacterial activity than CHX but lower than NaOCl. Only NaOCl negatively affected the bond strength of composite resin to dentin. In conclusion, erythrosine-mediated PDT shows potential as a cavity disinfectant due to its significant antibacterial effects against S. mutans and lack of adverse effects on bond strength.

Flowable Composite Resin의 미세변연누출 및 전단결합강도 (MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

자가부식 프라이머의 처리가 유치의 상아질과 레진 간의 결합 형태와 강도에 미치는 효과 (EFFECT OF SELF-ETCHING PRIMER APPLICATION ON THE CHARACTERISTICS & STRENGTH OF DENTIN BONDING IN PRIMARY TOOTH)

  • 이준행;김용기;김종수
    • 대한소아치과학회지
    • /
    • 제26권4호
    • /
    • pp.595-607
    • /
    • 1999
  • 본 연구의 목적은 최근 술식을 간소화 시켜 개발된 여러 가지 자가 부식 프라이머를 이용하여 유치에서의 상아질과 레진 간의 결합력을 측정하고, 그 결합의 양상을 주사 전자 현미경을 이용해 분석하기 위함이었다. 실험 재료로는 자가-부식 프라이머를 이용한 새로운 결합제인 Mac-bond $II^{(R)}$(Tokuso Co. Japan.)와 Clearfil Liner-bond $II^{(R)}$(Curaray Co. Japan.)가 각각 I군과 II군으로 사용되었고, 대조군으로 사용된 III군에 Scotchbond Multipurpose System(3M Co. U.S.A)이 사용되었다. 치관이 건전한 유구치 45개를 근원심으로 절단하여 레진에 매몰하고 상아질을 노출시켰다. 90개의 시편을 30개씩 3개의 군으로 나누고, 상아질 표면을 3가지 상아질 결합제를 이용하여 각 제조자의 지침에 따라 처리하여 실험 시편을 제작하였다. 각 군당 20개의 시편은 전단 강도를 측정한 후 그 파절면을 실체 현미경 하에서 관찰하였고, 각 군당 10개의 시편은 주사전자 현미경관찰을 위해 사용하였다. 전단강도 측정결과 III군, I군, II군의 순서로 높은 강도를 보였으며, III군과 II군, I군과 II군 사이에서 유의차를 보였으나(p<0.05), I군과 III군과의 사이에서는 유의차를 보이지 않았다(p>0.05). 실체 현미경 관찰 결과에서는 I군에서는 60%의 상아질내 파절과 40%의 계면 파절 양상을 보였고, II군에서는 20%의 상아질내 파절과 80%의 계면 파절 양상을 나타냈으며, III군의 경우 75%의 상아질내 파절과 25%의 계면 파절 양상을 나타내었다. 주사전자현미경 관찰 결과, 모든 군에서 $100-200{\mu}m$정도의 긴 resin tag양상을 보였으며, I군에서는 거의 균일한 긴 resin tag의 양상을 보인것에 반해 II군에서는 부분적으로 짧은 resin tag의 양상을 나타냈으며, III군의 경우 긴 resin tag뿐만 아니라 특징적인 측방 분지의 양상을 나타냈다.

  • PDF

Microabrasive로 처리한 상아질표면에 대한 복합레진의 결합강도에 관한 연구 (A STUDY OF THE BOND STRENGTHS OF COMPOSITE RESIN TO DENTIN SURFACES PREPARED WITH MICROABRASIVE)

  • 최경규;민병순
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.61-75
    • /
    • 1997
  • The bond strengths of composite resin to tooth dentin vary with the methods of cavity preparation and surface treatment. Recent developments in techniques of dentinal surface treatment have renewed interest in microabrasive as a means of tooth preparation, The purpose of this study was to determine the effects of a new method of cavity preparation on the bond of composite resin to dentin. Freshly extracted 144 healthy human third molars were used in this study. The dentin surfaces prepared with #600 SiC abrasive paper were divided into control and air abrasion groups according to the method of dentin surface preparation using different combinations of delivery pressure, time, and acid etching. The shear bond strengths were measured after the composite resin (Clearfil Photo Bright) was bonded to prepared dentin surfaces by light-curing using a dentin bonding system (All-bond 2), In addition, the average surface roughness was measured to investigate the effect of differently prepared dentin surfaces on the shear bond strengths. The surface changes of prepared dentin and the debonded dentin surfaces were observed with SEM (S-2300, Hitachi Co., Japan). The following results from this-study were obtained ; 1. There was no significant difference of shear bond strengths according to the changes of delivery pressure and time. 2. The shear bond strengths were lower than the control in the air abraded-only groups, but those of the additional acid-etched groups were higher than the control. 3. The shear bond strengths to all air-abraded surfaces were increased by acid etching. 4. The correlation between shear bond strengths and surface roughness was not certain, although the mean surface roughness of all air-abraded surfaces has increased evidently while it has slightly decreased for additional acid etching. 5. On SEM examination, the dentinal tubules were almost occluded in the air abraded-only groups, but those were opened in the additional acid-etched groups. 6. The debonded surfaces were showed adhesive failure mode in the air abraded- only groups, while those were showed mainly the mixed and cohesive failure mode in the additional acid-etched groups. These results suggest that the layer produced during cavity preparation or surface treatment with air abrasion must be removed for maximum bond strength of composite resin to dentin.

  • PDF

Pomegranate extract on eroded dentin: antioxidant action, bond strength and morphology of the adhesive interface after aging

  • Thiago Vinicius Cortez;Nathalia Mancioppi Cerqueira;Julia Adornes Gallas;Wanderley Pereira Oliveira;Silmara Aparecida Milori Corona;Aline Evangelista Souza-Gabriel
    • Restorative Dentistry and Endodontics
    • /
    • 제49권1호
    • /
    • pp.9.1-9.14
    • /
    • 2024
  • Objectives: This study aimed to evaluate the effect of pomegranate solution (Punica granatum) on eroded dentin through antioxidant action, shear bond strength (SBS) and interface morphology. Materials and Methods: The 10% pomegranate peel extract was prepared by the lyophilization method. Punicalagin polyphenol was confirmed by high-performance liquid chromatography. Antioxidant activity was evaluated by capturing the 2,2-diphenyl1-picrylhydrazyl (DPPH) radical. For the SBS, 48 dentin fragments were divided into sound or eroded, and subdivided according to the pretreatment (n = 12): water or P. granatum. The surfaces were restored with self-etch adhesive and a bulk-fill resin (Ecosite; DMG). The SBS was done immediately (24 hours) and after thermal cycling + water storage (12 months). For scanning electron microscopy, 48 dentin fragments (24 sound and 24 eroded) received the same treatments as for SBS (n = 6), and they were analyzed after 24 hours and 12 months. Results: The P. granatum had antioxidant action similar (p = 0.246) to the phenolic standard antioxidants. After 24 hours, eroded dentin had lower SBS than sound dentin (p < 0.001), regardless of the pretreatment. After 12 months, P. granatum maintained the SBS of sound dentin (13.46 ± 3.42 MPa) and eroded dentin (10.96 ± 1.90 MPa) statistically similar. The lowest values were found on eroded dentin treated with water (5.75 ± 1.65 MPa) (p < 0.001). P. granatum on eroded dentin caused peritubular demineralization and hybrid layer with resin tags. Conclusions: The pomegranate extract had antioxidant action and preserved the adhesive interface of the eroded dentin.

CPP-ACP 적용이 치면열구전색제의 결합강도에 미치는 영향 (THE EFFECT OF CPP-ACP PRE-TREATMENT ON BOND STRENGTH OF A SEALANT)

  • 공은경;정상혁;마연주;안병덕;정영정
    • 대한소아치과학회지
    • /
    • 제37권4호
    • /
    • pp.445-452
    • /
    • 2010
  • 최근 CPP-ACP의 초기 우식증의 재광화 및 예방 효과에 대한 연구가 많이 진행되고 있다. 그러나, CPP-ACP 적용으로 인한 법랑질 산부식 저항성 증가가 치면열구전색제 접착에 미치는 영향에 대해서는 연구가 부족한 실정이다. 본 연구에서는 CPP-ACP의 치면 도포 여부와 치면열구전색제의 접착 방법의 차이가 법랑질과 치면열구전색제의 결합력에 미치는 영향에 대하여 미세전단결합강도 측정법으로 알아보고자 하였다. 건전한 제3대구치를 사용하여 150개의 시편을 제작하였으며, 다음과 같이 6군으로 나누었다. I군: 인공타액에 2주 보관 후 35% 인산 산부식 II군: 인공타액에 2주 보관 후 35% 인산 산부식 + 접착제 III군: 인공타액에 2주 보관 후 자가 부식 접착제 IV군: CPP-ACP 2주 적용 후 35% 인산 산부식 V군: CPP-ACP 2주 적용 후 35% 인산 산부식 + 접착제 VI군: CPP-ACP 2주 적용 후 자가 부식 접착제 6군의 시편에 치면열구전색제 접착 후 미세전단결합강도를 측정하여 다음과 같은 결과를 얻었다. CPP-ACP 적용은 전통적인 산부식 방법으로 치면열구전색제를 접착하는 경우에는 결합강도와 산부식 양상에 영향을 미치지 않으나, 자가 부식 접착제를 사용한 경우에는 치면열구전색제의 결합강도를 약화시켰다.

불소처리된 치근상아질에 대한 심미수복재의 결합에 관한 연구 (A STUDY ON THE BOND OF AESTHETIC RESTORATIVE MATERIALS TO FLUORIDE TREATED ROOT DENTIN)

  • 탁홍수;박상진;민병순;최호영;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.197-212
    • /
    • 1998
  • The purpose of this study was to evaluate the effects of fluoride application on the aspect of shear bond strength of three aesthetic restorative materials to dentin. One light-cured composite resin(Palfique Esterite) and two light-cured glass ionomer cements(Fuji II LC and Compoglass)were used in this study. 120 permanent molars were used for this study. The teeth were extracted due to the origin of periodontal disease. The crowns of all teeth were removed, and the remaining roots were embedded in epoxy resin. The mesial or distal surfaces of roots were ground flat to expose dentin and polished on wet 320-, 400-, and 600 grit SIC papers for a total of 120 prepared flat root dentin surfaces. The prepared samples were divided into six groups. Group 1, 3, and 5 were control groups and group 2, 4, and 6 were experimental groups. Sixty samples for experimental groups were treated with 2% NaF solution for 5 minutes. Group 1 and 2 were bonded with Plafique Esterite, group 3 and 4 were bonded with Fuji II LC, and group 5 and 6 were bonded with Compoglass. After 24 hours water storage at $37{\pm}1^{\circ}C$, all samples were subjected to a shear to fracture with Instron universal testing machine(No.4467) at 1.0 mm/min displacement rate. Dentin surfaces treated with each conditioners before bonding and interfacial layers between dentin and aesthetic restorative materials were observed under Scanning Electron Microscope(Hitachi S-2300) at 20Kvp. The data were evaluated statistically at the 95% confidence level with ANOVA test. The result were as follows; 1. Among the control groups, group 1 showed strongest bond strength and group 3 showed weakest. 2. Among the experimental groups, group 2 showed strongest bond strength and group 6 showed weakest. 3. Statistical analysis of the data showed that pretreatment of dentin with 2% NaF solution significantly decreased the bond strength of three aesthetic restorative materials to dentin(P<0.05). 4. SEM findings of fluoride treated dentin surfaces (2, 4, 6 group) demonstrated dentin surfaces covered with fluoridated reaction products. 5. Except group 4 and 6, resin tags were formed in all groups.

  • PDF

상아질접착제에 대한 광조사가 접착에 미치는 영향 (INFLUENCE OF LIGHT IRRADIATION OVER SELF-PRIMING ADHESIVE ON DENTIN BONDING)

  • 류현욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.409-417
    • /
    • 2001
  • 상아질접착제의 광조사가 상아질접착에 미치는 영향을 알아보기 위하여 in vitro에서 접착실험을 하였다. 120개의 발거된 소의 전치 협면 상아질을 노출시키고 산 부식 한 다음 self-priming형 상아질접착제 Prime&Bond$^{\circledR}$NT (Dentsply DeTrey, GmbH, Konstanz, Germany)를 도포 하였으며 600 mW/$\textrm{cm}^2$의 일반광도 또는 1930 mW/$\textrm{cm}^2$의 초고광도 광조사를 각각 20초 및 3초간 시행한 군과 시행하지 않은 군으로 나누어 복합레진 첨가후 광조사하였다. 접착제에 대한 광조사를 시행하지 않은 경우에는 복합레진 첨가 후 초고광도로 3초, 6초 및 12초간 광조사하였다. 접착양상 평가를 위해 만능시험기로 전단접착강도를 측정하고 파단면을 입체 현미경으로 관찰한 바를 일원 및 이원 변량분석법과 카이제곱검사법으로 통계 분석하여 다음과 같은 결과를 얻었다. 1. 상아질접착제를 광조사한 군이 광조사하지 않은 군에 비해 유의하게 높은 전단접 착강도를 나타내었다 (p<0.05). 2. 일반 광도 및 초고광도 광조사에 따른 전단접착강도에는 유의한 차이가 나타나지 않았다 (p>0.05). 3. 상아질접착제를 광조사하지 않고 복합레진 첨가 후 초고광도로 광조사한 군간에 조사시간에 따른 전단접착강도에는 유의 한 차이가 나타나지 않았다 (p>0.05). 4. 파단면 관찰 결과, 모든 군에서 접착계면에서의 파절을 포함하는 혼합파단양상이 가장 많이 나타났으며 군간에는 유의한 차이가 없었다 (p>0.05).

  • PDF

Er:YAG 레이저를 조사한 유치 상아질의 전단결합강도에 관한 연구 (A STUDY OF SHEAR BOND STRENGTH OF ER:YAG LASER-IRRADIATED PRIMARY DENTIN)

  • 이진화;김종수;유승훈
    • 대한소아치과학회지
    • /
    • 제34권4호
    • /
    • pp.569-578
    • /
    • 2007
  • 본 연구는 자가 부식과 two-bottle system에 의한 레진 부착시 레이저와 일반 고속 핸드피스에 의한 치아형성 관계를 규명해보고자 하였다. 55개의 유치를 발거한 후 레진에 매몰하여 상아질을 노출시켜 시편을 준비하였고 다음과 같이 분류하였다. I군은 고속핸드피스로 치아 형성 후 $Adper^{TM}$ $Prompt^{TM}$ L-$Pop^{TM}$(3M Unitek, USA)을, II군은 Er:YAG 레이저로 치아 형성 후 $Adper^{TM}$ $Prompt^{TM}$ L-$Pop^{TM}$(3M Unitek, USA)을, III군은 레이저로 형성 후 산부식과 $Adper^{TM}$ Single Bond Plus Adhesive(3M Unitek, USA)를, IV군은 레이저로 형성 후 산부식 없이 $Adper^{TM}$ Single Bond Plus Adhesive(3M Unitek, USA)를 적용하였고 V군은 고속 핸드피스로 치아 형성 후 산부식과 $Adper^{TM}$ Single Bond Plus Adhesive(3M Unitek, USA)를 적용하였다. 레진 $Filtek^{TM}$ Z250(3M Unitek, USA)을 직경 1.5 mm, 길이 3 mm의 투명관에 충전 후 적용하였다. 각 그룹 시편의 전단강도를 측정하였고 레이저와 고속 핸드피스로 치아 형성 후와 각각 산부식을 한 후 주사전자 현미경으로 관찰한 결과 다음과 같은 결론을 얻었다. 1. 기존 방법인 고속 핸드피스를 이용한 치아 형성 후 산부식과 $Adper^{TM}$ Single Bond를 이용한 방법이 가장 높은 결합 강도를 보였다. 2. 레이저를 이용한 치아 형성 후 산부식을 하지 않고 $Adper^{TM}$ Single Bond를 이용한 방법은 가장 낮은 결합 강도를 보였다. 3. 고속 핸드피스를 이용한 치아 형성 후 $Prompt^{TM}$ L-$Pop^{TM}$을 이용한 레진 부착을 한 그룹과 레이저를 이용해 치아를 형성한 이후 산부식과 $Adper^{TM}$ Single Bond를 이용한 방법간의 결합 강도는 유의한 차이를 나타내지 않았다. 4. 레이저를 이용한 치아 형성 후 $Prompt^{TM}$ L-$Pop^{TM}$을 이용한 II군은 I, III, V군에 비해서는 결합강도가 낮았으나 IV군에 비해서는 결합강도가 유의성 있게 높았다. 5. 주사전자 현미경 관찰시 레이저로 치아 형성한 상아질 표면은 불규칙한 표면이 두드러졌으며 도말층이 제거되었음을 볼 수 있었고 산부식 후에는 불규칙한 부위가 줄어들고 상아세관이 커짐을 확인했다.

  • PDF