Effect of intracanal medicaments used in endodontic regeneration procedures on microhardness and chemical structure of dentin

  • Yassen, Ghaeth Hamdon;Eckert, George Joseph;Platt, Jeffrey Allen
    • Restorative Dentistry and Endodontics
    • /
    • 제40권2호
    • /
    • pp.104-112
    • /
    • 2015
  • Objectives: This study was performed to investigate the effects of different intracanal medicaments on chemical structure and microhardness of dentin. Materials and Methods: Fifty human dentin discs were obtained from intact third molars and randomly assigned into two control groups and three treatment groups. The first control group received no treatment. The second control group (no medicament group) was irrigated with sodium hypochlorite (NaOCl), stored in humid environment for four weeks and then irrigated with ethylenediaminetetraacetic acid (EDTA). The three treatment groups were irrigated with NaOCl, treated for four weeks with either 1 g/mL triple antibiotic paste (TAP), 1 mg/mL methylcellulose-based triple antibiotic paste (DTAP), or calcium hydroxide [$Ca(OH)_2$] and finally irrigated with EDTA. After treatment, one half of each dentin disc was subjected to Vickers microhardness (n = 10 per group) and the other half was used to evaluate the chemical structure (phosphate/amide I ratio) of treated dentin utilizing attenuated total reflection Fourier transform infrared spectroscopy (n = 5 per group). One-way ANOVA followed by Fisher's least significant difference were used for statistical analyses. Results: Dentin discs treated with different intracanal medicaments and those treated with NaOCl + EDTA showed significant reduction in microhardness (p < 0.0001) and phosphate/amide I ratio (p < 0.05) compared to no treatment control dentin. Furthermore, dentin discs treated with TAP had significantly lower microhardness (p < 0.0001) and phosphate/amide I ratio (p < 0.0001) compared to all other groups. Conclusions: The use of DTAP or $Ca(OH)_2$ medicaments during endodontic regeneration may cause significantly less microhardness reduction and superficial demineralization of dentin compared to the use of TAP.

수종 음료수의 법랑질과 상아질 침식에 관한 연구 (A STUDY OF THE INFLUENCES OF ACIDIC BEVERAGES ON EROSION OF ENAMEL AND DENTIN)

  • 장기택
    • 대한소아치과학회지
    • /
    • 제24권4호
    • /
    • pp.719-726
    • /
    • 1997
  • The aim of this study was to evaluate the in vitro effects of exposure to acidic beverages on microhardness of enamel and dentin. Thirty enamel specimens and thirty dentin specimens were obtained from extracted bovine maxillay incisiors. Enamel and dentin specimens were divided into three groups and treated with acidic beverages as follows; Group 1 : cola(pH 2.52), Group 2 : plain soda water(pH 2.93) and Group 3 : orange juice(pH 3.75). Erosive treatment was performed by storing each specimens for 5 min in 50ml solution of cola, soda water and orange juice. Average microhardness values(VHN) were determined before and after erosive treatment. All beverages produced significant loss of microhardness of enamel and dentin. Microhardness of enamel was reduced in the following order: Group 1 : $42.71{\pm}4.36(%)$, Group 2 : $37.09{\pm}6.25(%)$, Group 3 : $35.46{\pm}4.98(%)$. Microhardness of dentin was reduced in the following order: Group 1 : $17.14{\pm}3.42(%)$, Group 2 : $13.89{\pm}3.18(%)$, Group 3 : $13.82{\pm}3.50(%)$. The differences between group 1 and group 2, 3 were statistically significant(p< 0.05).

  • PDF

수복재에 함유된 불소가 치질의 미세경도와 불소 함유량에 미치는 영향 (INFLUENCE OF MICROHARDNESS AND FLUORIDE CONTENT OF TOOTH STRUCTURE BY FLUORIDE-CONTAINING RESTORATIVE MATERIALS)

  • 이수종;조영곤;김종욱;박병철
    • Restorative Dentistry and Endodontics
    • /
    • 제29권1호
    • /
    • pp.36-43
    • /
    • 2004
  • The purpose of this study was to compare the microhardness and the fluoride content of enamel and dentin around fluoride- or non fluoride-containing restorations. Forty extracted human teeth were used and prepared cervical cavities on proximal surface. Experimental teeth were divided into five groups . Group 1 : Prime & Bond NT and Z100, Group 2 Prime & Bond NT and F2000, Group 3 : Scotchbond Multi-purpose and Z100, Group 4 : Scothcbond Multi-purpose and F2000, Group 5 : Fuji II LC. The cavities were filled with dentin adhesives and restorative materials. After each tooth was bisected, one half was tested microharaness and the other half was analyzed the fluoride at the enamel and dentin by an EPMA-WDX device. The results were as follows; 1. There was no statistical difference among the microhardness of enamel surface in all group. 2. The microhardness at dentin of $100{\;}\mu\textrm{m}$ point in Group 2 and $20{\;}\mu\textrm{m}$ point in Grocup 4 was lower than that of normal dentin (p>0.05). 3. There was no statistical difference among the fluoride content of enamel surface in all group. 4. The fluoride content at the dentin of $30{\;}\mu\textrm{m}$ point in Group 2 and 5 were higher than those at $100{\;}\mu\textrm{m}{\;}and{\;}200{\;}\mu\textrm{m}$ point in Group 2 and normal dentin (p<0.05). 5. At the dentin of $30{\;}\mu\textrm{m}$ point, Group 2 showed higher fluoride content than Group 1 and 3, and Group 5 showed higher fluoride content than other groups.

Effect of acidic solutions on the microhardness of dentin and set OrthoMTA and their cytotoxicity on murine macrophage

  • Oh, Soram;Perinpanayagam, Hiran;Lee, Yoon;Kum, Jae-Won;Yoo, Yeon-Jee;Lim, Sang-Min;Chang, Seok Woo;Shon, Won-Jun;Lee, Woocheol;Baek, Seung-Ho;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • 제41권1호
    • /
    • pp.12-21
    • /
    • 2016
  • Objectives: To evaluate the effects of three acids on the microhardness of set mineral trioxide aggregate (MTA) and root dentin, and cytotoxicity on murine macrophage. Materials and Methods: OrthoMTA (BioMTA) was mixed and packed into the human root dentin blocks of 1.5 mm diameter and 5 mm height. Four groups, each of ten roots, were exposed to 10% citric acid (CA), 5% glycolic acid (GA), 17% ethylenediaminetetraacetic acid (EDTA), and saline for five minutes after setting of the OrthoMTA. Vickers surface microhardness of set MTA and dentin was measured before and after exposure to solutions, and compared between groups using one-way ANOVA with Tukey test. The microhardness value of each group was analyzed using student t test. Acid-treated OrthoMTA and dentin was examined by scanning electron microscope (SEM). Cell viability of tested solutions was assessed using WST-8 assay and murine macrophage. Results: Three test solutions reduced microhardness of dentin. 17% EDTA demonstrated severe dentinal erosion, significantly reduced the dentinal microhardness compared to 10% CA (p = 0.034) or 5% GA (p = 0.006). 10% CA or 5% GA significantly reduced the surface microhardness of set MTA compared to 17% EDTA and saline (p < 0.001). Acid-treated OrthoMTA demonstrated microporous structure with destruction of globular crystal. EDTA exhibited significantly more cellular toxicity than the other acidic solutions at diluted concentrations (0.2, 0.5, 1.0%). Conclusions: Tested acidic solutions reduced microhardness of root dentin. Five minute's application of 10% CA and 5% GA significantly reduced the microhardness of set OrthoMTA with lower cellular cytotoxicity compared to 17% EDTA.

Effect of Dentin Bonding Agent Acidity on Surface Microhardness of Mineral Trioxide Aggregate

  • Yun-Hui Im;Yoon Lee
    • Journal of Korean Dental Science
    • /
    • 제17권1호
    • /
    • pp.36-44
    • /
    • 2024
  • Purpose: This study investigated the effect of dentin bonding agent acidity on surface microhardness of MTA. Materials and Methods: Forty cylindrical molds (3 mm×5 mm) were prepared, and three dentin bonding agents with different acidities: Adper Single Bond 2 (ASB), Single Bond Universal (SBU), and Clearfil SE bond 2 (CSE) were applied to the inner surface of the molds (n=10). No bonding agent was applied in the control group. MTA was mixed and inserted into the molds and sealed with a wet cotton pellet for 4 days. After setting, the Vickers microhardness (HV) test was done at 200, 400, 600 ㎛ from the inner surface of the mold. One-way ANOVA was conducted for all samples. A P-value of less than .05 was considered significant. Tukey HSD test was performed for post-hoc analysis. Results: The mean HV values and standard deviations were 67.02±11.38 (Con), 48.76±11.33 (ASB), 43.78±11.19 (CSE), 37.84±9.36 (SBU), respectively. The difference between the control group and the experimental groups was statistically significant (P<0.001). The difference between ASB and SBU was statistically significant (P<0.001), while the difference between SBU and CSE was not. There were no statistically significant differences between the various points from the inner surface of the mold within each group (P>0.05). Conclusion: Results of the current study indicate that use of dentin bonding agents with MTA can reduce the surface microhardness of MTA. Moreover, there is a direct relationship between the acidity of dentin bonding agents and the surface microhardness of MTA.

각각의 광조사기가 복합레진의 미세경도와 미세누출에 미치는 영향 (EFFECT OF EACH LIGHT CURING UNITS ON THE MICROHARDNESS AND MICROLEAKAGE OF COMPOSITE RESIN)

  • 정유진;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제29권1호
    • /
    • pp.58-67
    • /
    • 2004
  • The objectives of this study was to evaluate current visible light curing units regarding microhardness and microleakage. Fourty samples of composite resin(Z-250, 3M) were cured by different light curing units (Flipo, LOKKI; Credi II, 3M; XL 3000, 3M: Optilux 500, Demetron) in acrylic blocks. Microhardness was measured using a calibrated Vickers indenter on both top and bottom surfaces after 24 hours of storage in air at room temperature. Class V cavities were prepared on buccal and lingual surfaces of fourty extracted human molars. Each margin was on enamel and dentin/cementum. Composite resin(Z-250, 3M) was filled in cavities and cured by four different light curing units (Flipo, LOKKl; Credi II, 3M; XL 3000, 3M: Optilux 500, Demetron). The results of this syudy were as follows: Microhardness 1. Flipo showed low microhardness compared to Optilux 500, Credi II significantly in upper surface. Flipo didn't show a significant difference compared to XL 3000. 2. The microhardness resulting from curing with Flipo was lower than that of others on lower surfaces. Microleakage 1. Dentin margin showed significantly high dye penetration rate than enamel margin in all groups(p<0.05). 2. No significant differences were found on both enamel and dentin margin regarding curing units.

수산화칼슘 근관충전제의 적용이 유치 치근상아질의 미세경도에 미치는 영향 (Effect of Calcium Hydroxide on the Microhardness of Root Dentin of Primary Tooth)

  • 전새로미;김종빈;유승훈
    • 대한소아치과학회지
    • /
    • 제40권3호
    • /
    • pp.177-184
    • /
    • 2013
  • 수산화칼슘 근관충전제는 뛰어난 항균작용과 낮은 세포독성으로 우수한 유치 근관충전제로 평가되고 있다. 하지만 수산화칼슘을 근관 내 장기간 적용할 경우 치근 상아질에 미치는 부정적인 영향이 논의되고 있으며 많은 연구에서 영구치 근관에 수산화칼슘을 적용 후 상아질 경도의 감소가 확인되었다. 본 연구에서는 수산화칼슘 제제의 적용 기간에 따라 유치 치근 상아질의 미세경도를 측정하여, 수산화칼슘의 적용이 유치 치근 상아질의 미세경도에 미치는 영향을 평가하고자 하였다. 생리적 치근 흡수가 1/3이상 진행되지 않은 시기에 발거된 60개의 상악 유전치를 각각 20개 씩 대조군, 수산화칼슘과 요오드포름의 혼합제제(Vitapex, Neodent., Japan), 수산화칼슘과 증류수의 혼합제제를 적용하는 3개의 군으로 분류하였다. 각 치아는 같은 과정의 치수 절제술을 시행한 후 교정용 레진에 매몰하여 군당 5개 치아를 배정하고 24시간, 7일, 30일, 90일 후 치근 중앙부에서 2 mm 두께의 시편을 획득하여 비커스 미세경도 측정기를 통해 미세경도를 측정하였다. 측정된 미세경도 값은 Kruskal-Wallis test로 변수 간의 상호관계를 확인하였으며 사후 검정으로 Mann-Whitney test를 시행하였다. 시간에 따른 미세경도 값의 감소량은 선형 회귀분석을 통해 추이를 분석하였다. 수산화칼슘 근관 충전제가 유치의 치근 상아질의 미세경도에 미치는 영향을 조사한 결과, 다음과 같은 결론을 얻을 수 있었다. 수산화칼슘 근관 충전제를 유치의 근관에 적용 시 기간에 따라 치근상아 질의 미세경도가 감소하였으며, 이는 통계적으로 유의하였다(p < 0.05). 수산화칼슘과 요오드화포름의 혼합제제에 비해 수산화칼슘을 증류수에 혼합하여 적용한 경우 유치 치근상아질의 미세경도가 더 급격하게 감소하였으며, 이는 통계적으로 유의하였다(p < 0.05). 수산화칼슘을 적용하지 않은 대조군에서도 7일, 30일, 90일 후 기간에 따라 치근상아질의 미세경도가 감소하였으며, 이는 통계적으로 유의하였다(p < 0.05).

한국인(韓國人)의 중(中)·측절치(側切齒) 경조직(硬組織) 미소경도(微小硬度)에 관(關)한 연구(硏究) (STUDIES ON THE MICROHARDNESS OF CENTRAL AND LATERAL INCISORS OF THE KOREAN)

  • 정재규
    • Restorative Dentistry and Endodontics
    • /
    • 제2권1호
    • /
    • pp.38-49
    • /
    • 1976
  • Central and lateral incisors of 20, 40 and 60 age groups were bisected pararelly to long axis and middle portion of mesio-distal of teeth. And author measured the hardness of various areas in enamel and dentin with vickers hardness tester. Measured levels were divided into the labio-middle portion, middle portion of incisal edge and linguo-middle portion in enamel and dentin of all age groups. The results were as follows; 1) Total average hardness of enamel for 20, 40 and 60 age groups were respectively Hv. 366.5${\pm}$5.75, Hv. 372.9${\pm}$8.16 and Hv. 389.8${\pm}$10.27. 2) Total average hardness of dentin for 20, 40 and 60 age groups were respectively Hv. 51.0${\pm}$2.14, Hv. 54.0${\pm}$1.87 and Hv. 55.3${\pm}$2.23. 3) Total microhardness values in enamel and dentin of 60 age group was highered than 20 and 40 age groups. 4) The hardness values of enamel and dentin in all age groups were detected lower value on the middle portion of incisal edge than the labio-middle portion and linguo-middle portion. 5) Microhardness values of enamel was highered gradually from the dentinoenamel junction to the outer surface and it lowered at the outermost surface in all age groups. The microhardness values of dentin were the highest values at 600${\mu}$ from dentino-enamel junction and the lowest values at near the pulp chamber in all age groups.

  • PDF

Nd : YAG, HO : YAG, Er : YAG 레이저 조사에 의한 상아질의 물리적 변형 및 절제(切除)역치에 관한 연구 (PHYSICAL MODIFICATION AND ABLATION THRESHOLDS OF DENTIN INDUCED BY ND : YAG, HO : YAG, AND ER : YAG LASERS)

  • 이상호
    • 대한소아치과학회지
    • /
    • 제23권4호
    • /
    • pp.954-967
    • /
    • 1996
  • Laser application to modify healthy permanent dentin to improve microhardness and caries resistence has been previously reported but the physical modification and ablation thresholds of carious and sclerotic dentin has yet to be identified. This study determined the energy density required by modify (physical modification threshold, PMT) and remove (ablation threshold, AT) infected carious, affected and selerotic dentin compared to healthy permanent dentin. $1{\pm}0.25mm$ thick dentin sections(n=272) from extracted human teeth were used. Smear layer was removed 0.5M EDTA for 2 minutes. Utilizing three pulsed fiberopitc delivered contact lasers with different emission wavelengths($1.06{\mu}m$=Nd : YAG, $2.10{\mu}m$=Ho : YAG and $2.94{\mu}mEr$ : YAG). The energy density($J/cm^2$) was incrementally increased and the resulting tissue interaction classified on a scale from 0-6. A minimum of 5 repetitions/energy density were completed. Light microscopy(10-25X) was used to verify the physical modification(scale=3) and ablation thresholds(scale=4) of the various forms of dentin and the data were analyzed by logistic regression at the 95 % confidence interval. PMT and AT by the laser and the dentin types were: PMT and AT was lower in infected dentin than in sound dentin for all lasers. PMT and AT induced by Nd : YAG>Ho : YAG>Er : YAG for all forms of dentin. Microhardness was increased in sound dentin at PMT. Morphology of crater examined by light microscopy showed Nd : YAG was safe and effective for removing carious dentin and Er: YAG was effective for removing sound dentin. The PMT and AT for YAG lasers are different as a function of dentin type which may be utilized for selective modification and removal of dentin.

  • PDF

상아질 표면처리후 복합레진 수복시 온도변화가 결합에 미치는 영향 (EFFECT OF THERMOCYCLING ON BONDING OF COMPOSITE RESIN AFTER DENTIN SURFACE TREATMENTS)

  • 이용우;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.126-142
    • /
    • 1991
  • The purpose of this study was to evaluate the effect of various dentin surface treatments on shear bond strength, microhardness and fracture mode before and after thermocycling. Recently extracted 75 human molars were used. The teeth were sagittal sectioned faciolingually to obtain 150 specimens. They were randomly divided into six groups. Mesial and distal dentinal surfaces of specimens were exposed by grinding and treated respectively with GC-DENTIN CONDITIONER. 10-3 solution of 4-Meta, Cleansar and Primer of GLUMA, Scotchprep of Scotchbond 2, DENTIN CONDITIONER and PRIMER A, B of ALL BOND according to the manufacturers directions. Specimens of one group were not treated. Adhesive agent of Scotchbond 2, were applied and cured on the treated dentin surfaces. After P-50 were cured on them, specimens were stored in 31c water for 24 hours before shear bond strength measurement Shear bond strength was measured in 10 specimens of each group. 10 specimens of each group were thermocycled in $20^{\circ}C$, $60^{\circ}C$,$20^{\circ}C$, $4^{\circ}C$, $20^{\circ}C$ water in order, for 30 seconds respectively, 100 times a day for 7 days. After thermocycling shear bond strength was measured. Microhardness was checked on treated dentin surface and fractured dentin surface in 10 specimens respectievly. Francture modes were observed with SEM The following results were obtained. 1. Before thermocycling. shear bond strengths in the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND were significantly higher than those in other specimens(P<0.01). 2. After thermocycling. shear bond strengths in the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2 and DENTIN CONDITIONER and PRIMER A, B of AIL BOND were significantly higher than those in specimens not: treated, treated with GC-DENTIN CONDITIONER and 10-3 solution of 4-Meta(P<0.01). Shear bond strengths in the specimens treated with GC-DENTIN CONDITIONER and PRIMER A, B of ALL BOND were significantly higher than those in other specimens except those treated with Scotchprep of Srotchbond 2(P<0.01). 3. Shear bond strengths after thermocycling were reduced in the specimens not treated, treated with GC-DENTIN CONDITIONER and 10-3 solution of 4-Meta and were increased in the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2, without significance, compared with those before thermocycling. In the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND, shear bond strengths after thermocycling were significantly increased, compared with those before thermocycling(P<0.01). 4. Microhardnesses in the fractured surfaces after shear bond strength measurement were significantly increased in the specimens treated with 10-3 solution of 4-Meta and significantly decreased in the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND, compared with those in the treated dentin surfaces(P<0.01). 5. In the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2 and DENTIN CONDITIONER and PRIMER A, B of ALL BOND, cohesive fracture modes were observed more than adhesive fracture modes.

  • PDF