Browse > Article
http://dx.doi.org/10.5395/JKACD.2004.29.1.058

EFFECT OF EACH LIGHT CURING UNITS ON THE MICROHARDNESS AND MICROLEAKAGE OF COMPOSITE RESIN  

Jung, Eu-Jin (Department of Conservative dentistry, College of Dentistry, Pusan National University)
Lee, Hee-Joo (Department of Conservative dentistry, College of Dentistry, Pusan National University)
Hur, Bock (Department of Conservative dentistry, College of Dentistry, Pusan National University)
Publication Information
Restorative Dentistry and Endodontics / v.29, no.1, 2004 , pp. 58-67 More about this Journal
Abstract
The objectives of this study was to evaluate current visible light curing units regarding microhardness and microleakage. Fourty samples of composite resin(Z-250, 3M) were cured by different light curing units (Flipo, LOKKI; Credi II, 3M; XL 3000, 3M: Optilux 500, Demetron) in acrylic blocks. Microhardness was measured using a calibrated Vickers indenter on both top and bottom surfaces after 24 hours of storage in air at room temperature. Class V cavities were prepared on buccal and lingual surfaces of fourty extracted human molars. Each margin was on enamel and dentin/cementum. Composite resin(Z-250, 3M) was filled in cavities and cured by four different light curing units (Flipo, LOKKl; Credi II, 3M; XL 3000, 3M: Optilux 500, Demetron). The results of this syudy were as follows: Microhardness 1. Flipo showed low microhardness compared to Optilux 500, Credi II significantly in upper surface. Flipo didn't show a significant difference compared to XL 3000. 2. The microhardness resulting from curing with Flipo was lower than that of others on lower surfaces. Microleakage 1. Dentin margin showed significantly high dye penetration rate than enamel margin in all groups(p<0.05). 2. No significant differences were found on both enamel and dentin margin regarding curing units.
Keywords
Plasma arc; Microleakage; Microhardness;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Sakaguchi RL, Peters MC, Nelson SR. Douglas WH, Poort HW. Effects of polymerization contraction in composite restorations J Dent 20:179 182, 1992
2 Gerzina TM, Hume WR. Effect of hydrostatic pressure on the diffusion of monoers through dentin in vitro. J Dent Res 74:369 373, 1995   DOI   ScienceOn
3 Tirtha R, Fan PL, Dennison JB. Powers JM. In vitro depth fo cure of photh activated composite. J Dent Res 61:1184 1187, 1982   DOI   PUBMED   ScienceOn
4 Curtis JW, Rueggeberg FA, Lee AJ Curing efficiency of the turbo tip. Gen Dent 43:428 433, 1995
5 RW Loney, RBT Price. Temperature transmission of high output light curing units through dentin. Oper Dent 26:516 520, 2001
6 Haitz RH, Craford MG, Wiessman RH. Handbook of optics. vol 2. New York, McGraw Hill. 12.1 12.9 1995
7 Nakamura S, Mukai T, Senoh M. Candela class high brightness InGaN/AlGaN Double heterostructure blue light emitting diodes. Appl Phys Lett 64:1687 1689, 1994
8 McCabe JF, Carrick TE. Output from visible light activation units and depth of cure of light activated composite. J Dent Res 68:1534 1539, 1989   DOI   PUBMED   ScienceOn
9 Price RB, Derand T. Robert W. Loney, Pantelis Andrew. Effect of light source and specimen thickness on the surface hardness of resin composite. Am J Dent 15:47 53, 2002   PUBMED
10 Park SH. Krejci I, Lutz F. Microhardness of resin composites polymerized by plasma arc or conventional visible light curing. Oper Dent 27:30 37, 2002
11 Gagloani M, Fadini L, Ritzmann JM. Depth of cure efficacy of high power curing devices vs traditional halogen lamps. J Adhes Dent4:41 47, 2002   PUBMED
12 Mitton BA, Wilson NHF. The use and maintenance of visible light activating units in general practice. Br Dent J 191:81-86, 2001
13 Sakaguchi RL, Douglas WH, Peters MC. Curing light performance and polymerization of composite restorative materials. J Dent 20:183 188, 1992   DOI   ScienceOn
14 Leonard DL, Charlton DG, Hilton TJ. Effect of curing tip diameter on the accuracy of dental radiometers. Oper Dent 24:31 37, 1999
15 Brackett W.W, Haisch LDA, Covey DA. Effect of plasma arc curing on the micrileakage of Class V resin based conposite restorations. Am J Dent 13:121 123, 2000   PUBMED
16 Hofmann N, Hugo B, Schubert K, Klaiber B. Comparison between a plasma arc light source and conventional halogen curing units regarding flexural strength, modulus and hardness of photoactivated resin composites. Clin Oral Invest 4:140 147, 2000   DOI   ScienceOn
17 Davidson Kaban SS, Davidson CL, Feilzer AJ. The effect of curing light variations on bulk curing and wall to wall quality of two types and various shades of resin composite. Dent Mater 13:344 352, 1997   DOI   ScienceOn
18 Tarle Z, Meniga A, Ristic M, Sutalo J, Pichler G, Davidson CL. The effect of the photopolmerization method on the quality of composite resin samples. J Pral Rehabil 25: 436 442, 1998   DOI   ScienceOn
19 Rueggeberg FA, Caughman WF, Curtis JW Jr. Effect of light intensity and exposure duration on cure of resin composite. Poer Dent 19:26-32, 1994
20 Miyazaki M, Hattori T, Ichiishi Y, Kondo M, Onose H, Moore B. Evaluation of curing units used in dental office. Oper Dent 23:50 54, 1998
21 Rueggeberg FA, Caughman WF, Curtis JW Jr, Davis HC. Factors affecting cure at depths withn light activated resin composites. Am J Dent6:91 05, 1993   PUBMED
22 Hamid A, Okamoto A, Iwaku M, Hume WR. component release from light activated glass ionomer and compomer cements. J Oral Rehabil 25:98, 1998
23 Sharkey S, Roy N, Burke F, Ziada H, Hannigun A. Surface Hardness of light activated resin composites cured by two different visible light sources:An invitro study. Dent Mater 32:401 405, 2002
24 Prati C, Chersoni S, Montebugnoli L, Montanari G. Effect of air, Dentin and resin based composite thick ness on light intensity reduction Am J Dent 12:231 234, 1999   PUBMED
25 Sakaguchi RL, Peters MC, Nelson SR, Douglas WH And Poort HW. Effects of polynerization contraction in composite restorations. J Dent 20:178 182, 1992   DOI   ScienceOn
26 Solomon CS, Osman YI. Evaluating the efficacy of curing lights. South Afr DEnt J 54:357 562, 1999
27 Feilzer AJ, Dooren LH, de Gee AJ, Davidson CL. Influence of light intensity on polymerization shrinkage and integrity of restoration cavity interface. Eur J Oral Sci 103: 322 326, 1995   DOI   ScienceOn
28 Bouschlocher MR, Heiner AD. Ploymerization shrinkage force with xenon short arc or QTH photoillumination. J Dent Res 80(Special issue):Abstract #1737 p253, 2001
29 Uno S, Asmussen A. Marginal adaptation of a restorative resin polymerized at reduced rate. Scand J Dent Res 99:440 444, 1991
30 Yearn JA. Factors affecting cure of visible light activated composites. Int Dent J 35: 218 225 1985   PUBMED
31 Leonard DL, Charlton DG, Hilton TJ. Effect of curing tip diameter on the accuracy of dental radiomenters. Oper Dent 24:31-37, 1999
32 Peutzfeldt A, Sahafi A, Asmussen E. Characterization of resin composites polymerized with plasma arc curing units. Dent Mater 16:3320 3326, 2000
33 Johnston W, Leung R, Fan P. Amathematical model for post irradiation hardening of photoactivated composite resins. Dent Mater 1:191 194, 1985   DOI   ScienceOn
34 Sturdecant CM. The art and science of operative dentistry. 3rd ed. St Louis, Mosby, 269. 1995
35 Rueggeberg FA. Craig RG. Correlation WF, conversion of parameters used to estimate. J Dent Res 67:932 93, 1988   DOI   PUBMED   ScienceOn
36 Martin FE. A survery of the efficicency of visible light curing units. J Dent 23:239 243, 1998
37 Vargas MA, Cobb DS, Schmit JL. Polymerization of composite resins: argon laser vs conventional light. Oper Dent 23;87 93, 1998
38 Venhovon BAM, De Gee AJ, DAvidson CL. Polymerization contraction and converson of light curing Bis CMA based methacrtylate Resins. Biomaterials 14L871 875, 1993   DOI   ScienceOn
39 Uno S, Asmussen E. Marginal adaptation of a restorative resin polymerized at reduced rate. Scand J Dent Res 99:440 444, 1991
40 Ferracane JL. Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins. Dent Master 1:11 14, 1985   DOI   ScienceOn
41 Davidson CL, de Gee AJ. Relaxation of polymerization contraction stresses by flow in dental composites. J Dent Res 63:146 148, 1984   DOI   PUBMED   ScienceOn
42 Mehl A, Hickel R, Kunzelmann KH. Physical properties and gap formation of light cured composites with and without 'softstart polymerization', J Dent25:321 330, 1999   DOI   ScienceOn
43 Cook WD. Spectral distribution of dental photopoly merizing sources. J Dent Res 61: 1436 1438, 1982   DOI   PUBMED   ScienceOn
44 Rueggeberg FA, Jordan DM. Effect of light tip distance on polymerization of resin composite. Int J Prosth 6:364 370, 1993
45 Rueggeberg FA/ Contemporary issues in photocuring Compend contin Educ Dent 20:S4 15, 1999
46 Leonard DL, Charlton DG, Roberts HR, Hilton TJ, Zionic A. DEtermination of the minimum irradiance required for adequate polymerization of a hybrid and a microfill composite. Poer Dent 26:176 180, 2001
47 Venhoven BA, de Gee AJ, Davidson CL. Polymaerization contraction and conversion of light curing bis GMA based methacrylate resins. Biomaterials 14:871 875, 1993   DOI   ScienceOn
48 Rueggeverg FA, Cughman WF, Curtis JW Jr. Factors affecting cure at depths within light activated resin composite. Am J Dent 6:91 95, 1993   PUBMED
49 Geurtsen W. Substances released from dental resin composites and glass ionomer cements. Eur J Oral Sci 106(2 Pt 2):687 695, 1998. Review   DOI