• 제목/요약/키워드: Dental technique

검색결과 1,116건 처리시간 0.025초

Fabrication of a Patient-Customized Helmet with a Three-Dimensional Printer for Radiation Therapy of Scalp

  • Oh, Se An;Lee, Chang Min;Lee, Min Woo;Lee, Yeong Seok;Lee, Gyu Hwan;Kim, Seong Hoon;Kim, Sung Kyu;Park, Jae Won;Yea, Ji Woon
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.100-105
    • /
    • 2017
  • The purpose of the present study was to develop and evaluate patient-customized helmets with a three-dimensional (3D) printer for radiation therapy of malignant scalp tumors. Computed tomography was performed in a case an Alderson RANDO phantom without bolus (Non_Bolus), in a case with a dental wax bolus on the scalp (Wax_Bolus), and in a case with a patient-customized helmet fabricated using a 3D printer (3D Printing_Bolus); treatment plans for each of the 3 cases were compared. When wax bolus was used to fabricate a bolus, a drier was used to apply heat to the bolus to make the helmet. $3-matic^{(R)}$ (Materialise) was used for modeling and polyamide 12 (PA-12) was used as a material, 3D Printing bolus was fabricated using a HP JET Fusion 3D 4200. The average Hounsfield Unit (HU) for the Wax_Bolus was -100, and that of the 3D Printing_Bolus was -10. The average radiation doses to the normal brain with the Non_Bolus, Wax_Bolus, and 3D Printing_Bolus methods were 36.3%, 40.2%, and 36.9%, and the minimum radiation dose were 0.9%, 1.6%, 1.4%, respectively. The organs at risk dose were not significantly difference. However, the 95% radiation doses into the planning target volume (PTV) were 61.85%, 94.53%, and 97.82%, and the minimum doses were 0%, 77.1%, and 82.8%, respectively. The technique used to fabricate patient-customized helmets with a 3D printer for radiation therapy of malignant scalp tumors is highly useful, and is expected to accurately deliver doses by reducing the air gap between the patient and bolus.

무가압 분말충전 알루미나에 이트리아를 함유한 붕규산염 유리를 침투시킨 코아 도재의 물성 (THE PHYSCIAL PORPERTIES OFY Y2O3-CONTAINING GLASS INFILTRATED ALUMINA CORE MADE BY PRESSURELESS POWDER PACKING METHOD)

  • 황승우;이근우
    • 대한치과보철학회지
    • /
    • 제35권1호
    • /
    • pp.221-243
    • /
    • 1997
  • The objective of this study was to characterize the mechanical properties of $Y_{2}O_{3}$-containing glass infiltrated ceramic core material, which was made by pressureless powder packing method. A pure alumina powder with a grain size of about $4{\mu}m$ was packed without pressure is silicon mold to form a bar shaped sample, and applied PVA solution as a binder. Samples were sinterd at $1350^{\circ}C$ for 1 hour. After cooling, $Y_{2}O_{3}$-containing glass($SiO_{2},\;Y_{2}O_{3},\;B_{2}O_{3},\;Al_{2}O_{3}$, ect) was infiltrated to the sinterd samples at $1300^{\circ}C$ for 2 hours and cooled. Six different proportions $Y_{2}O_{3}$ of were used to know the effect of the mismatch of the thermal expansion coefficient between alumina powder and glass. The samples were ground to $3{\times}3{\times}30$ mm size and polished with $1{\mu}m$ diamond paste. Flexural strength, fracture toughness, hardness and other physical properties were obtained, and the fractured surface was examined with SEM and EPMA. Ten samples of each group were tested and compared with In-Ceram(tm) core materials of same size made in dental laboratory. The results were as follows : 1. The flexural strengths of group 1 and 3 were significantly not different with that of In-Ceram, but other experimental groups were lower than In-Ceram. 2. The shrinkage rate of samples was 0.42% after first firing, and 0.45% after glass infiltration. Total shrinkage rate was 0.87%. 3. After first firing, porosity rate of experimental groups was 50%, compared with 22.25% of In-Ceram. After glass infiltration, porosity rate of experimental groups was 2%, and 1% in In-Ceram. 4. There was no statistical difference in hardness between two materials tested, but in fracture toughness, group 2 and 3 were higher than In-Ceram. 5. The thermal expansion coefficients of experimental groups were varied to $4.51-5.35{\times}10^{-6}/^{\circ}C$ according to glass composition, also the flexural strengths of samples were varied. 6. In a view of SEM, many microparticles about $0.5{\mu}m$ diameter and $4{\mu}m$ diameter were observed in In-Ceram. But in experimental group, the size of most particles was about $4{\mu}m$, and a little microparticles was observed. The results obtained in this study showed that the mismatch of the thermal expansion coefficients between alumina powder and infiltrated glass affect the flexural strength of alumin/glass composite. The $Y_{2}O_{3}$-containing glass infiltrated ceramic core made by powder packing method will takes less time and cost with sufficient flexural strength similar to all ceramic crown made with slip casting technique.

  • PDF

가토의 상악동 골이식술시 미분화 간엽 줄기세포의 골형성 효과 (THE EFFECTS OF UNDIFFERENTIATED MESENCHYMAL STEM CELLS ON SINUS BONE GRAFTING IN RABBIT)

  • 오승환;채영원;김범수;여인범;조필귀
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권6호
    • /
    • pp.520-530
    • /
    • 2006
  • Undifferentiated mesencymal stem cells(UMSCs) have been thought to be multipotent cells that can replicate as undifferentiated cells and that have the potential to differentiate into lineages of mesenchymal tissue including the bone, cartilage, fat, tendon, muscle, and marrow stroma. It can be used to sinus lifting, Guided bone regeneration, other bone graft in dental part. The purpose of this study is to evaluate the effect of mesencymal stem cells on sinus augmentation with autogenous bone, fibrin glue mixture in a rabbit model. 8 New Zealand white rabbits were divided randomly into 4 groups based on their time of sacrifice(1, 2, 4 and 8 weeks). First, undifferentiated mesenchymal stem cells were isolated from iliac crest marrow of rabbits and expanded in vitro. cell culture was performed in accordance with the technique described by Tsutsumi et al. In the present study, The animals were sacrificed at 1, 2, 4 and 8 weeks after transplantation, and the bone formation ability of each sides was evaluated clinically, radiologically, histologically and histomorphologically. According to the histological observations, Stem cell group showed integrated graft bone with host bone from sinus wall. At 2 and 4weeks, It showed active newly formed bone and neovascularization. At 8 weeks, lamella bone was observed in sinus graft material area. Radiologically, autobone with stem cell showed more radiopaque than autobone without stemcell. there were significant differences in bone volume between 2 and 4 weeks (p<0.05). In summary, the autobone with stem cells had well-formed, newly formed bone and neovasculization, compared with the autobone without stem cells (esp. 2 weeks and 4 weeks) The findings of this experimental study indicate that the use of a mixture of mesenchymal stem cell yielded good results in osteogenesis and bone volume comparable with that achieved by autogenous bone. Therefore, this application of this promising new sinus floor elevation method for implants with tissue engineering technology deserves further study.

Barbiturates가 소의 대뇌피질 Synaptosomal Plasma Membrane Vesicles로 부터 추출 제제한 총지질 및 총인지질 인공세포막에 형성된 비대칭적 유동성에 미치는 비대칭적 영향 (Effects of Barbiturates on Transbilayer Fluidity Domains of Phospholipid Model Membrane Monolayers)

  • 윤일;강정숙
    • 대한약리학회지
    • /
    • 제28권1호
    • /
    • pp.103-114
    • /
    • 1992
  • 한국산 2년생 소의 신선한 대뇌피질로 부터 synaptosomal plasma membrane vesicles (SPMV)를 분리한 후 이 SPMV로 부터 추출한 총지질 (SPMVTL) 및 총인지질 (SPMVPL)로서 인공세포막을 제제하였다. SPMVTL 및 SPMVPL의 outer monolayer에 trinitrophenyl groups로 공유결합시킴으로써 형광 probe 1,6-diphenyl-1,3,5-hexatriene (DPH)의 outer monolayer 형광을 선택적으로 소광케한 후 SPMVTL 및 SPMVPL의 inner와 outer monolayer 사이의 비대칭적 유동성 존재 유무를 확인하였던 바 inner monolayer에 비하여 outer monolayer가 유동성이 크다는 것을 확인하였으며 SPMVTL에 비하여 SPMVPL의 유동성이 높았다. 뿐만 아니라 barbiturates는 SPMVTL의 유동성에 대하여는 유의성이 있을 만큼의 증감 효과를 나타내지 않았고 SPMVPL의 유동성은 감소시키되 주로 outer monolayer의 유동성을 감소시킨다는 것을 확인하였으며 barbiturates 종류에 따른 SPMVPL의 총유동성 감소의 크기는 pentobarbital > hexobarbital > amobarbital > phenobarbital의 순이었다.

  • PDF

n-Alkanols가 소의 대뇌피질 Synaptosomal Plasma Membrane Vesicles로부터 추출 제제한 총지질 인공세포막 이중층간에 형성된 비대칭적 유동성에 미치는 비대칭적 영향 (Transbilayer Effects of n-Alkanols on the Fluidity of Model Membranes of Total Lipids Extracted from Synaptosomal Plasma Membrane Vesicles)

  • 윤일;강정숙
    • 대한약리학회지
    • /
    • 제28권2호
    • /
    • pp.191-199
    • /
    • 1992
  • 한국산 2년생 소의 대뇌피질로부터 synaptosomal plasma membrane vesicles(SPMV)를 분리한 후 이 SPMV로부터 추출한 총지질로서 인공세포막(SPMVTL)을 제제하였다. SPMVTL의 outer monolayer에 trinitrophenyl group을 공유결합시킴으로써 SPMVTL이중층에 분포된 형광 probe 1,6-diphenyl-1,3,5-hexatriene(DPH)중 outer monolayer에 분포된 DPH형광만을 소광케 하였다. 형광분석기를 통하여 SPMVTL의 inner monolayer에 비하여 outer monolayer의 유동성이 크다는 것을 확인하였다. n-Alkanols는 SPMVTL지질 이중층(inner+outer monolayers)의 회전확산운동을 증가시키되 탄소수 두개가 증가될 때마다 그 효력이 약10배 가량 증가된다는 것을 알았다. 그러나 1-decanol의 경우에는 1-nonanol에 비하여 그 효력이 낮아지는 소위 cut-off현상이 나타났다. 뿐만 아니라 n-alkanols는 SPMVTL의 inner monolayer에 비하여 outer monolayer의 회전확산운동을 주로 증가시켰다. 하지만 n-alkanols의 탄소수가 증가됨에 따라 outer monolayer에 대한 선택적인 작용이 감소된다는 것도 확인되었다.

  • PDF

Hydrogen peroxide inhibits Ca2+ efflux through plasma membrane Ca2+-ATPase in mouse parotid acinar cells

  • Kim, Min Jae;Choi, Kyung Jin;Yoon, Mi Na;Oh, Sang Hwan;Kim, Dong Kwan;Kim, Se Hoon;Park, Hyung Seo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제22권2호
    • /
    • pp.215-223
    • /
    • 2018
  • Intracellular $Ca^{2+}$ mobilization is closely linked with the initiation of salivary secretion in parotid acinar cells. Reactive oxygen species (ROS) are known to be related to a variety of oxidative stress-induced cellular disorders and believed to be involved in salivary impairments. In this study, we investigated the underlying mechanism of hydrogen peroxide ($H_2O_2$) on cytosolic $Ca^{2+}$ accumulation in mouse parotid acinar cells. Intracellular $Ca^{2+}$ levels were slowly elevated when $1mM\;H_2O_2$ was perfused in the presence of normal extracellular $Ca^{2+}$. In a $Ca^{2+}-free$ medium, $1mM\;H_2O_2$ still enhanced the intracellular $Ca^{2+}$ level. $Ca^{2+}$ entry tested using manganese quenching technique was not affected by perfusion of $1mM\;H_2O_2$. On the other hand, $10mM\;H_2O_2$ induced more rapid $Ca^{2+}$ accumulation and facilitated $Ca^{2+}$ entry from extracellular fluid. $Ca^{2+}$ refill into intracellular $Ca^{2+}$ store and inositol 1,4,5-trisphosphate ($1{\mu}M$)-induced $Ca^{2+}$ release from $Ca^{2+}$ store was not affected by $1mM\;H_2O_2$ in permeabilized cells. $Ca^{2+}$ efflux through plasma membrane $Ca^{2+}-ATPase$ (PMCA) was markedly blocked by $1mM\;H_2O_2$ in thapsigargin-treated intact acinar cells. Antioxidants, either catalase or dithiothreitol, completely protected $H_2O_2-induced$ $Ca^{2+}$ accumulation through PMCA inactivation. From the above results, we suggest that excessive production of $H_2O_2$ under pathological conditions may lead to cytosolic $Ca^{2+}$ accumulation and that the primary mechanism of $H_2O_2-induced$ $Ca^{2+}$ accumulation is likely to inhibit $Ca^{2+}$ efflux through PMCA rather than mobilize $Ca^{2+}$ ions from extracellular medium or intracellular stores in mouse parotid acinar cells.

Effect of Lidocaine-HCl on Microviscosity of Phosphatidylcholine Model Membrane

  • Chung, In-Kyo;Kim, Inn-Se;Choi, Chang-Hwa;Cho, Goon-Jae;Kim, Jin-Bom;Son, Woo-Sung;Jang, Hye-Ock;Yun, Il
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제4권3호
    • /
    • pp.243-251
    • /
    • 2000
  • In order to provide a basis for studying the molecular mechanism of pharmacological action of local anesthetics and to develop a fluorescence spectroscopic method which can detect the microviscosity of native and model membranes using intramolecular excimerization of 1,3-di(l-pyrenyl)propane (Py-3-Py), we examined the effect of lidocaine HCl on the microviscosity of model membranes of phosphatidylcholine fraction extracted from synaptosomal plasma membrane vesicles (SPMVPC). The excimer to monomer fluorescence intensity ratio (I'/I) of Py-3-Py in liquid paraffin was a simple linear function of $T/{\eta}.$ Based on this calibration curve, the microviscosity values of the direct probe environment in SPMVPC model membranes ranged from $234.97{\pm}48.85$ cP at $4^{\circ}C$ to %19.21{\pm}1.11$ cP at $45^{\circ}C.$ At $37^{\circ}C,$ a value of $27.25{\pm}0.44$ cP was obtained. The lidocaine HCl decreased the microviscosity of SPMVPC model membranes in a concentration-dependent manner, with a significant decrease in microviscosity value by injecting the local anesthetic even at the concentration of 0.5 mM. These results indicate that the direct environment of Py-3-Py in the SPMVPC model membranes is significantly fluidized by the lidocaine HCl. Also, the present study explicitly shows that an interaction between local anesthetics and membrane lipids is of importance in the molecular mechanism of pharmacological action of lidocaine HCl.

  • PDF

심하게 위축된 하악골의 완전 무치악 환자에서의 수직 골신장술을 이용한 임플란트 치료 (IMPLANT INSTALLATION USING VERTICAL DISTRACTION OSTEOGENESIS AT A SEVERELY ATROPHIED EDENTULOUS MANDIBLE)

  • 염학렬;전승호;김윤태;팽준영;안강민;명훈;황순정;서병무;최진영;이종호;정필훈;김명진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권2호
    • /
    • pp.154-165
    • /
    • 2006
  • Objectives : It is difficult to place implants at a severely atrophied edentulous mandible because of vertical and horizontal alveolar defect. The autogenous and allogenic bone graft and guided bone regeneration are useful, but there are some limitations such as the resorption and infection of the grafted bone, and insufficiency of soft tissue. Distraction osteogenesis has recently evolved a challenging technique to overcome major draws of conventional augmentation procedures, we, therefore, report the four applications of implant placement after vertical alveolar distraction osteogenesis. Patients and Methods : Four patients(all female, mean age: $60{\pm}6$ years) with severe alveolar ridge deficiencies at their anterior mandible were treated with vertical alveolar distraction osteogenesis by intraoral device(Track 1.5, 15 mm model, KLS Martin, Tuttlingen, Germany) and placement of implants (Branemark MK III, TiUnite). After the latency periods of 5, 7, 8 days, distraction rhythm and rate were $0.5\;mm{\times}2\;times/day$ in the case of good bone quality, and $0.25\;mm{\times}3\;times/day$ in the case of poor bone quality. After consolidation periods of mean fifteen weeks, five implants for each patients were placed at the interforaminal area. Results : On average, a vertical gain of $11.38{\pm}1.38\;mm$ was obtained by distraction. And all distraction zone showed complete ossification by panoramic radiography. There were no postoperative complications other than numbness of lower lip in one case. Total twenty implants in four patients were placed and their outcomes were satisfactory. Conclusion : It is a useful method to place five implants after vertical distraction osteogenesis of the severely atrophied mandible for the implant-supported fixed prosthesis.

분층피부와 분말골로 이식 전 처리된 유리견갑골근피판과 임플란트 보철을 이용한 경구개와 상악골의 기능적 재건 (FUNCTIONAL RECONSTRUCTION OF DENTO-PALATAL AND MAXILLARY DEFECT USING STAGED OPERATION OF PREFABRICATED SCAPULAR FREE FLAP AND DENTAL IMPLANTS)

  • 이종호;김명진;박종철;김영수;안강민;팽준영;김성민;명훈;황순정;서병무;최진영;정필훈
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권4호
    • /
    • pp.301-307
    • /
    • 2004
  • The flap considered at first for the reconstruction of large maxillary defect, especially mid-face defect, is scapular free flap, because it provides ample composite tissue which can be designed 3-dimensionally for orbital, facial and oral reconstruction. In case of maxillary defect involving hard palate, however, this flap has some limitations. First, its bulk prevents oral function and physio-anatomic reconstruction of nasal and oral cavity. Second, mobility and thickness of cutaneous paddle covering the alveolar area reduce retention of tissue-supported denture and give rise to peri-implantitis when implant is installed. Third, lateral border of scapula that is to reconstruct maxillary arch and hold implants is straight, not U-shaped maxillary arch form. To overcome these problems, new concept of step prefabrication technique was provided to a 27-year-old male patient who had been suffering from a complete hard palate and maxillary alveolar ridge defect. In the first stage, scapular osteomuscular flap was elevated, tailored to fit the maxillary defect, particulated autologous bone was placed subperiosteally to simulate U-shaped alveolar process, and then wrapped up with split thickness skin graft(STSG, 0.3mm thickness). Two months later, thus prefabricated new flap was elevated and microtransferred to the palato-maxillary defect. After 6 months, 10 implant fixtures were installed along the reconstructed maxillary alveolus, with following final prosthetic rehabilitation. The procedure was very successful and patient is enjoying normal rigid diet and speech.

전부도재수복물을 위한 수종의 코어 세라믹의 반투명도 및 색 안정성 (Translucency and Color Stability of Various Core Ceramics for All-Ceramic Restoration)

  • 오상천;이해형;신미란;박광수
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.157-170
    • /
    • 2007
  • Purpose: This investigation was designed to determine the translucency and color stability of various core ceramics for all-ceramic restoration using the CIE $L^*a^*b^*$ system. Material and Methods: IPS e.max Press ceramic(Ivoclar-Vivadent, Liechtenstein), $LAVA^{TM}$ All Ceramic(3M-Espe, Germany), Cercon Smart Ceramic(Dentsply, Germany), and Z-match Ceramic(DentAim, Korea) were used for this study. For the specimens of zirconia oxide ceramics, the as-sintered cylindrical blanks($11.0{\times}25.0mm$) were machined into the shape of a disk(0.4, 0.8, 1.5 mm in thickness, 10 mm in diameters) with a diamond grind machine. The IPS e.max Press specimens ($0.8{\times}10mm$) were fabricated using the "lost wax" technique. CIE $L^*a^*b^*$ coordinates and light transmission were recorded for each specimen with a spectrophotometer(CM-2600d, Minolta, Japan). Color differences were calculated using the equation, ${\Delta}E^*ab=[({\Delta}L^*)2+({\Delta}a^*)2+({\Delta}b^*)2]1/2$. Results: The results were obtained as follows: 1. The most translucent group was IPS e.max Press ceramic that is a glass-ceramic, and $Lava^{TM}$ and Z-match ceramic were more translucent than Cercon Smart ceramic in zirconia ceramic group. 2. In the all groups, there was no significant translucent change after 6 times heat-treatments required to make a final restoration. 3. Colored zirconia was showed more yellowish and dark than uncolored zirconia. 4. After heat-pressing, IPS e.max Press ceramic was showed high ${\Delta}E^*ab$ value(4.1 of eM1, 6.8 of eM2) that means to be more whiter than before heat-pressing. However, there was no color change after additive heat treatments for final restoration. 5. In the colored zirconia groups, there was no significant color change after some heat-treatments required to make a final restoration.