• 제목/요약/키워드: Dental technique

검색결과 1,119건 처리시간 0.021초

타이타늄의 표면개질에 따른 도재 결합 특성 (THE BOND CHARACTERISTICS OF PORCELAIN FUSED BY TITANIUM SURFACE MODIFICATION)

  • 최택휴;박상원;방몽숙;양홍서;박하옥;임현필;오계정;김현승;이광민;이경구
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.169-181
    • /
    • 2007
  • Statement of problem: Titanium is well known as a proper metal for the dental restorations, because it has an excellent biocompatibility, resistance to corrosion, and mechanical property. However, adhesion between titanium and dental porcelains is related to the diffusion of oxygen to the reaction layers formed on cast-titanium surfaces during porcelain firing and those oxidized layers make the adhesion difficult to be formed. Many studies using mechanical, chemical and physical methods to enhance the titanium-ceramic adhesion have been actively performed. Purpose: This study meant to comparatively analyse the adhesion characteristics depending on different titanium surface coatings after coating the casts and wrought titanium surfaces with Au and TiN. Material and method: In this study, the titanium specimens (CP-Ti, Grade 2, Kobe still Co. Japan) were categorized into cast and wrought titanium. The wrought titanium was cast by using the MgO-based investment(Selevest CB, Selec). The cast and wrought titanium were treated with Au coating($ParaOne^{(R)}$., Gold Ion Sputter, Model PS-1200) and TiN coating(ATEC system, Korea) and the ultra low fusing dental porcelain was fused and fired onto the samples. Biaxial flection test was done on the fired samples and the porcelain was separated. The adhesion characteristics of porcelain and titanium after firing and the specimen surfaces before and after the porcelain fracture test were observed with SEM. The atomic percent of Si on all sample surfaces was comparatively analysed by EDS. In addition, the constituents of specimen surface layers after the porcelain fracture and the formed compound were evaluated by X-ray diffraction diagnosis. Result: The results of this study were obtained as follows : 1. The surface characteristics of cast and wrought titanium after surface treatment(Au, TiN, $Al_2O_3$ sandblasting) were similar and each cast and wrought titanium showed similar bonding characteristics. 2. Before and after the biaxial flection test, the highest atomic weight change of Si component was found in $Al_2O_3$ sandblasted wrought titanium(28.6at.% $\rightarrow$ 8.3at.%). On the other hand, the least change was seen in Au-Pd-In alloy(24.5at.% $\rightarrow$ 9.1at.%). 3. Much amount of Si components was uniformly distributed in Au and TiN coated titanium, but less amount of Si's was unevenly dispersed on Al2O3 sandblasting surfaces. 4. In X-ray diffraction diagnosis after porcelain debonding, we could see $Au_2Ti$ compound and TiN coating layers on Au and TiN coated surfaces and $TiO_2$, typical oxide of titanium, on all titanium surfaces. 5. Debonding of porcelain on cast and wrought titanium surface after the biaxial flection is considered as a result of adhesion deterioration between coating layers and titanium surfaces. We found that there are both adhesive failure and cohesive failure at the same time. Conclusion: These results showed that the titanium-ceramic adhesion could be improved by coating cast and wrought titanium surfaces with Au and TiN when making porcelain fused to metal crowns. In order to use porcelain fused to titanium clinically, it is considered that coating technique to enhance the bonding strength between coating kKlayers and titanium surfaces should be developed first.

티타늄에 대한 레진과 도재의 결합 강도에 관한 연구 (The study on the shear bond strength of resin and porcelain to Titanium)

  • 박지만;김영순;전슬기;박은진
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.46-52
    • /
    • 2009
  • 연구목적: 최근 임플란트 상부보철물의 주재료로서 티타늄의 수요가 증가하고 있고, 급속도로 발전하고 있는 CAD/CAM (computer - aided design/computer-aided manufacturing) 기술이 접목되어 티타늄을 절삭하여 제작하는 방법이 주목을 받고 있으며 치과 임상에서 점점 그 영역이 넓어지고 있다. 다만, 하나의 티타늄괴를 절삭하여 만드는 방법의 특성상 기계적 유지력을 얻을 수 있는 비드 등을 형성할 수 없고, 통상적인 재료인 금 합금이나 도재용 합금 주조체에 비해 도재와의 결합력도 떨어지는 것이 보완해야 할 점으로 지적되고 있다. 이에 본 연구는 절삭형 티타늄을 이용한 보철물 제작에 많이 사용되고 있는 열중합 의치상 레진, 간접 복합 레진, 도재와 Grade II 순수 티타늄 사이의 결합 강도를 비교 평가해 보고자 하였다. 연구 재료 및 방법: 지름 9 mm, 높이 10 mm의 Grade II 순수 티타늄 원통형 시편 37개를 3군으로 나누어 각각 직경 7 mm, 높이 1 mm의 열중합 의치상 레진 (Lucitone 199, DENTSPLY Trubyte, York, USA), 간접 복합 레진 (Sinfony, 3M ESPE, Seefeld, Germany), 도재 (Triceram, Dentaurum, Ispringen, Germany)와 결합시켰다. 시편은 $5-55^{\circ}C$에서 1000회 열순환 처리 후, 범용 시험기 (Instron, Universal Testing Machine, Model 4465, USA)를 이용하여 1 mm/min의 속도로 하중을 가하여 전단결합강도를 측정하였다. 파절된 단면의 양상을 관찰하고 각 군별 파절양상을 조사하였다. 측정값은 one-way ANOVA와 Scheffe's multiple range test (${\alpha}=0.05$)로 분석하였다. 결과: 열중합 의치상 레진인 Lucitone 199 ($17.82{\pm}5.13\;MPa$)의 결합 강도가 가장 높았으며, 도재인 Triceram ($12.97{\pm}2.11\;MPa$), 복합레진인 Sinfony ($6.00{\pm}1.31\;MPa$) 순으로 감소하였다. Lucitone 199와 Sinfony 군의 파절 양상은 대부분이 부착성 파절인 데에 반해 Triceram 군에서는 복합성 파절이 많았다. 결론: CAD/CAM을 이용한 절삭형 티타늄 구조물 상방에 전장용 심미 재료로는 열중합형 의치상 레진이 가장 강한 결합 강도를 보인다. 기존의 주조체의 유지구 등에서 얻는 강도에 비해 약하고, 부착성 파절이 많은 점 등은 향후 이들 재료와 티타늄간의 결합력을 높이기 위한 보다 많은 연구가 이루어져야 할 것을 시사한다.

치과 교정용 자가중합형 Resin의 중합 온도 변화에 따른 굽힘 특성 (Flexural Properties according to Change of Polymerization Temperature of Autopolymerized Resin for Orthodontic)

  • 이규선
    • 치위생과학회지
    • /
    • 제15권3호
    • /
    • pp.259-264
    • /
    • 2015
  • 치과 교정용 자가중합형 레진의 중합 온도가 기계적 특성에 미치는 영향을 알아보기 위하여 폴리머와 모노머의 부피비는 2.5:1로 하고, 중합 온도를 $25^{\circ}C$, $40^{\circ}C$, $70^{\circ}C$의 세 group으로 나누었다. 실험을 위해 각 group 당 10개씩의 시편을 중합 시간 15분, 중합 압력 3 bar로 통일하여 제작하였다. 그 후 시편을 실험 전까지 $37^{\circ}C$의 증류수에 48시간 이상 보관한 다음, Intron (3344)을 이용하여 각 시편의 FS 및 EM을 측정하였다. 이렇게 하여 얻어진 값들은 SPSS ver. 16.0을 사용하여 일원 배치 분산 분석을 하였으며 Scheffe의 사후 검정을 실시하여 다음과 같은 결과를 얻었다. 치과 교정용 자가중합형 레진의 FS 평균값을 비교해 보았을 때 $25^{\circ}C$ group은 $71.500{\pm}5.546MPa$, $40^{\circ}C$ group은 $74.920{\pm}4.237MPa$, $70^{\circ}C$ group은 $76.880{\pm}4.304MPa$의 범위였으며, $25^{\circ}C$ group<$40^{\circ}C$ group<$70^{\circ}C$ group 순으로 차이가 있었으나 통계적으로 유의한 차이는 없었다(p=0.052). 치과 교정용 자가중합형 레진의 EM 평균값은 $25^{\circ}C$ group이 $2.164{\pm}0.073MPa$, $40^{\circ}C$ group은 $2.258{\pm}0.069MPa$, $70^{\circ}C$ group은 $2.282{\pm}0.147MPa$의 범위였으며, $25^{\circ}C$ group<$40^{\circ}C$ group<$70^{\circ}C$ group 순으로 중합 온도가 높을수록 유의한 차이를 보였다(p<0.039). 이상의 실험 결과로 미루어 볼 때 EM 값은 $25^{\circ}C$ group<$40^{\circ}C$ group<$^70{\circ}C$ group 순으로 통계적 유의성이 인정되는 수준의 상승이 있었던 반면, FS 값은 통계적 유의성은 보이고 있지 않으나 강도의 증가에 영향을 미치고 있으므로, 치과 교정 장치 제작 시 일정 수준의 중합 온도 상승은 장치의 기계적 물성을 증가시킬 것이라고 판단된다.

내부연결 임플란트 상부구조물에서 나사조임술식이 풀림토크값에 미치는 영향 (The effect of screw tightening techniques on the detorque value in internal connection implant superstructure)

  • 최정한
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.243-250
    • /
    • 2010
  • 연구 목적: 본 연구는 잘 맞는 임플란트 상부구조물에서 서로 다른 나사조임순서와 조임방법이 나사의 풀림토크값에 미치는 영향을 평가하였다. 연구 재료 및 방법: 서로 수동적 적합 관계를 갖는 완전 무치악 하악 주모형과 네 개의 평행한 임플란트 (Astra Tech)에 직접 연결되는 금속구조물을 제작하였다. 금속구조물과 잘 맞는 실험모형을 위해 주모형에서 연결인상법을 이용하여 여섯 개의 경석고 모형을 얻었다. 20 Ncm로 조인 후 나사의 풀림토크값을 두 번 측정하였다. 세 가지 나사조임순서 (1-2-3-4, 2-4-3-1, 그리고 2-3-1-4)와 두 가지 나사조임방법 (two-step과 one-step)에 대한 나사의 풀림토크값과 최소풀림토크값을 유의수준 .05에서 각각 다원분산분석법 (multi-way ANOVA)과 이원분산분석법 (two-way ANOVA)을 이용하여 통계분석 하였다. 결과: 나사조임순서에 대한 나사의 평균 풀림토크값은 12.8 Ncm (2-4-3-1)에서 13.1 Ncm (2-3-1-4)의 값을 보였고, 나사조임방법에 대한 값은 13.1 Ncm (two-step)와 11.8 Ncm (one-step)였다. 나사조임순서에 대한 나사의 평균 최소풀림토크값은 11.1 Ncm (1-2-3-4)와 11.2 Ncm (2-4-3-1과 2-3-1-4)였고, 나사조임방법에 대한 값은 11.2 Ncm (two-step)와 9.9 Ncm (one-step)였다. 나사의 풀림토크값과 최소풀림토크값은 세 가지 나사조임순서 간에 통계학적으로 유의성 있는 차이가 없었다. 그러나 두 가지 나사조임방법 간에는 두 값 모두 통계학적으로 유의성 있는 차이가 있었다. 나사를 두 단계로 나누어 조이는 방법이 한 번에 조이는 방법보다 더 큰 풀림토크값 (P = .0003)과 더 큰 최소풀림토크 값 (P = .0035)을 보였다. 결론: 본 연구와 같은 조건하에서, 연결인상법으로 얻은 잘 맞는 임플란트 상부구조물에 있어서 나사조임순서는 나사의 풀림토크값에 영향을 미치는 중요한 요소는 아니었다. 그러나 나사를 두 단계로 나누어 조이는 방법은 한 번에 조이는 방법보다 더 큰 풀림토크값을 보였다.

연마 방법과 칫솔질이 아크릴릭 레진의 표면 거칠기에 미치는 영향 (The effects of polishing technique and brushing on the surface roughness of acrylic resin)

  • 이주리;정철호;최정한;황재웅;이동환
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.287-293
    • /
    • 2010
  • 연구 목적: 본 연구는 연마 술식에 따른 polymethyl methacrylate (PMMA)의 표면 거칠기의 차이를 비교하고, 광중합 광택제가 PMMA의 표면 거칠기에 주는 영향과 이후 칫솔질에 의한 거칠기의 변화를 알아보는데 그 목적이 있다. 연구 재료 및 방법: 총 60개의 $10{\times}10{\times}5\;mm$ 크기의PMMA 시편을 만들었다. 중합 방법 (압력 하 중합과 대기압 하 중합)과 표면 연마 방법 (기계적 연마와 화학적 연마)에 따라 대조군을 포함하여 각 10개씩 총 6군으로 나누었다. 기계적 연마는 카바이드 덴처버로 표면 마무리 한 후, 러버 포인트와 퍼미스를 이용하여 하였으며, 화학적 연마는 표면 마무리 후 광중합 광택제 ($Plaquit^{(R)}$; Dreve-Dentamid GMBH)를 도포하여 실시 하였다. 연마가 완료된 후 비 접촉식 3차원적 표면 형상 분석장치인 Accura $2000^{(R)}$으로 표면거칠기를 측정하였으며, 그 3차원적 영상을 얻었다. 그 후 칫솔질에 의한 마모의 영향을 평가하기 위해 초음파 전동 칫솔을 이용하여 각 시편당 칫솔질을 행하고 다시 Accura $2000^{(R)}$에 의한 표면 분석을 시행하였으며, 거칠기의 정도는 Ra 값으로 표시하였다. 연마 후와 칫솔질 후의 표면 거칠기를 비교하기 위한 통계적 분석은 Mann-Whitney test와 t-test를 이용하여 95% 유의수준에서 실시하였다. 결과: 화학적 연마군은 기계적 연마군에 비해 통계적으로 유의한 작은 평균 표면 거칠기 값을 보였으며 (P = .0045), 일반 대기압 하에서 중합시킨 군에서 그 차이가 더 크게 나타났다 (P = .0138). 초음파 전동 칫솔에 의한 모의 칫솔질 후 표면 거칠기는 기계적 연마군을 제외한 모든 군에서 크게 증가하였으며, 칫솔질 후의 표면 거칠기는 각 군에서 통계적으로 유의한 차이를 보이지 않았다. 결론: 비록 칫솔질에 의한 마모의 영향으로 표면 거칠기가 증가하기는 하지만, 화학적 연마가 기계적 연마에 비해 우수한 표면 거칠기를 보인다고 할 수 있다.

터널형 2급와동 충전재의 탄성계수와 전단결합강도 및 수복치의 변연융선 파절강도에 관한 연구 (ELASTIC CONSTANTS, SHEAR BOND STRENGTH OF TUNNEL RESTORATIVE MATERIALS AND MARGINAL RIDGE STRENGTH OF RESTORED TEETH)

  • 이가연;박영준;양규호
    • 대한소아치과학회지
    • /
    • 제23권3호
    • /
    • pp.746-763
    • /
    • 1996
  • An alternative design to conventional class II cavity preparation for proximal carious lesions is the tunnel preparation. It preserves the marginal ridge intact, thus making it possible to maintain the natural contact relationship with the adjacent tooth and minimize tooth reduction. This in vitro study was purposed to evaluate the effect of the materials' elastic constants and shear-bond strength on the marginal ridge fracture resistance of teeth restored by the tunnel technique, and to find the materials of choice for tunnel restorations. $Resinomer^{(R)}$, $Ketac-silver^{(R)}$, $Miracle-Mix^{(R)}$, and Tytin were used as restorative material. The elastic constants of each restorative material were evaluated by ultrasonic pulse measurement. Young's modulus and bulk modulus of the restorative materials were evaluated in three specimens for each material type. The shear-bond strength of the restorative materials to the dentin surface was measured after thermocycling 400 times between 6 and $60^{\circ}C$, using ten specimens for each material type. For measuring marginal ridge strength, 60 sound extracted molar teeth were distributed into six groups by size. Sound molar teeth were used as a Control group and unfilled prepared teeth were grouped as Unrestored. Another four groups were named Resinomer group, Ketac-Silver group, Miracle Mix group, and Tytin group by type of restorative material. Tunnel cavity preparation was done with ' 1/2, 2, and 4 round burs in sequence. Initial access to proximal surface was made through an occlusal access preparation started at least 2mm from the marginal ridge, and the proximal opening was formed about 2.5mm below the marginal ridge. After restoration and thermocycling, marginal ridge strength was measured using a universal testing machine. The results were as follows: 1. The Young's modulus of $Tytin^{(R)}$ was 63.95 GPa, followed by $Ketac-Silver^{(R)}$ 27.60 GPa, $Miracle-mix^{(R)}$ 18.48 GPa, and $Resinomer^{(R)}$ 10.74 GPa showing significant differences between the groups(P<0.05). The bulk modulus of the materials showed the same order as Young's modulus. The value of $Tytin^{(R)}$ showed 59.57 GPa indicating that it will deform less than other materials under the same stress. It was followed by $Ketac-Silver^{(R)}$ 23.57 GPa, Miracle $Mix^{(R)}$ 12.50 GPa, and $Resinomer^{(R)}$ 11.60 GPa. 2. The Resinomer group had a shear-bond strength of 7.41 MPa which was significantly higher than those of the Ketac-Silver group (1.80 MPa) and the Miracle Mix group (2.84 MPa) (P<0.01). All the specimens of Tytin group detatched from the dentin surface during thermocycling. 3. The mean marginal ridge strength of the Unrestored group(46.14 kgf) was significantly lower than that of the Control group (84.24 kgf) (P<0.01). The marginal ridge strength of teeth restored by the tunnel technique was, in order, Ketac-Silver group 74.06 kgf, Miracle Mix group 73.36 kgf, Resinomer group 63.47 kgf, and Tytin group 58.76 kgf. The Ketac-Silver, Miracle Mix, and Resinomer groups showed no significant difference with the Control group (P>0.05), but the Tytin group showed significantly lower strength compared to the Control group(P<0.05). The results showed that the marginal ridge strength of the teeth restored by the tunnel technique was not significantly lower than that of sound teeth. They also demonstrated that the bonding strength of the restorative material to the tooth surface should be high and the modulus of elasticity should not be lower than that of the tooth in order to restore the marginal ridge strength to its natural condition.

  • PDF

하악골 매식 부위 계측을 위한 나선형 단층촬영술의 신뢰도 (RELIABILITY OF SPIRAL TOMOGRAPHY FOR IMPLANT SITE MEASUREMENT OF THE MANDIBLE)

  • 김기덕;박창서
    • 치과방사선
    • /
    • 제27권2호
    • /
    • pp.27-47
    • /
    • 1997
  • The purpose of this study was to evaluate the accuracy and usefulness of spiral tomography through the comparison and analysis of SCANORA cross-sectional tomographs and DentaScan computed tomographic images of dry mandibles taken by a SCANORA spiral tomographic machine and a computed tomographic machine. Thirty-one dry mandibles with full or partial edentulous areas were used. To evaluate the possible effect of location in the edentulous area, it was divided into 4 regions of Me (region of mental foramen), MI (the midportion between Me and M2), M2 (the midportion between mental foramen and mandibular foramen) and S (the midportion of the mandibular symphysis). A ZPC column (sized 4 mm x 5 mm) was seated on the edentulous regions of Me, MI, M2 and S using the acrylic stent. Then SCANORA spiral tomography and computed tomography were taken on the edentulous regions which contained the ZPC column. The ZPC columns and cross-sectional images of the mandible were measured in the radiographs by three observers and the differences between the two imaging modalities were analysed. The results were as follows: 1. In comparing the actual measurements of the ZPC column and measurements in the radiographs, the mean error of the DentaScan computed tomography was 0.07 mm in vertical direction and -0.06 mm in horiwntal direction, while the mean error of the SCANORA spiral tomography was 0.06 mm in vertical direction and -0.12 mm in horizontal direction. There was a significant difference between the two radiographic techniques in the horizontal measurement of the ZPC column of the symphysis region (p<0.05). But there was no significant difference in the measurements of other regions (p>0.05). 2. In measurements of the distance from the alveolar crest to the inferior border of the mandible (H), and of the distance from the alveolar crest to the superior border of the mandibular canal (Y), there was no significant difference between the two radiographic techniques (p>0.05). 3. In measurements of the distance from the lingual border of the mandible to the buccal border of the mandible (W), and of the distance from the lingual border of the mandible to the lingual border of the mandibular canal (X), there was a significant difference between the two radiographic techniques in measurements of the midportion between the mental foramen and the mandibular foramen (M2) (p<0.05). But there were no significant differences in measurements of the other regions of symphysis (S), mental foramen (Me), the first one-fourth portion between the mental foramen and the mandibular foramen (M1) (p>0.05). 4. Considering the mean range of measurements between observers, the measurements of SCANORA spiral tomography showed higher value than those of DentaScan computed tomography, except in measurements of symphysis (S). 5. On the detectability of the mandibular canal, there was no significant difference between the two radiographic techniques (p>0.05). In conclusion, SCANORA spiral tomography demonstrated a higher interobserver variance than that of DentaScan computed tomography for implant site measurements in the posterior edentulous area of the mandible. These differences were mainly the result of difficulty in the detection of the border of the mandible in SCANORA spiral tomography. But considering the cost and the radiation exposure, SCANORA spiral tomography can be said to be a relatively good radiographic technique for implant site measurement.

  • PDF

심미적 포스트 코어의 종류에 따른 미세누출에 관한 연구 (Microleakage of endodontically treated teeth restored with three different esthetic post and cores)

  • 박지근;박지만;박은진
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.53-60
    • /
    • 2009
  • 연구목적: 오늘날 심미적 요구의 증가로 치아색 포스트 코어에 대한 많은 관심이 모아지고 있으며 다양한 연구가 진행 중이다. 현재 화이버 포스트 (ParaPost fiber White, Coltene Whaledent, Cuyahoga Falls, USA), 지르코니아 포스트 (CosmoPost, Ivoclar Vivadent, Schann, Germany) 등에 관한 논문은 다소 나와 있으나 요즘 여러 분야에서 관심을 받고 있는 CAD/CAM (computer-aided design/computer-aided manufacturing) 방식으로 지르코니아를 가공한 절삭형 지르코니아 포스트 코어에 대한 연구는 많지 않은 실정이다. 이 연구의 목적은 CAD/CAM을 이용한 지르코니아를 비롯하여 근관치료된 치아에서 사용된 세 가지 다른 치아색 포스트 코어에 대해 미세누출 (microleakage)을 비교해 보는 것이다. 연구 재료 및 방법: 발치된 건전한 상악 절치 27개를 채택하여 백악법랑질경계 (CEJ)에서 절단하여 근관치료를 시행하고, 세군 (각 9개)으로 나누었다. 각군들은 화이버 포스트와 콤포짓트 레진 코어 (1군), 지르코니아 포스트와 열가압형 세라믹 코어 (2군), CAD/CAM 절삭형 지르코니아 포스트 코어 (3군)로 수복하였다. $5-55^{\circ}C$ 1000회 열순환 처리 (thermocycling)를 시행하고, 2% 메틸렌 블루로 $37^{\circ}C$에서 24시간 염색하였다. 치아장축과 평행하게 순설방향으로 절단하여 미세누출을 현미경과 컴퓨터 프로그램을 사용하여 분석을 하였다. 데이터는 one-way ANOVA와 Scheffe's multiple range test (${\alpha}=0.05$)로 분석하였다. 결과: 모든 군에서 미세누출을 보였으며, 지르코니아 포스트와 열가압형 세라믹 코어군 (2군)에서 치근계면 입구에서는 다소 많은 미세누출을 보였으나 포스트 끝에 이르러서는 거의 미세누출이 없는 결과를 보였다. 화이버 포스트와 콤포짓트 레진 코어군 (1군)과CAD/CAM 절삭형 지르코니아 포스트 코어군 (3군)에서는 부위별로 균등한 미세누출을 보였다. 결론: 화이버 포스트와 콤포짓트 레진 코어군, 지르코니아 포스트와 열가압형 세라믹 코어군, CAD/CAM 절삭형 지르코니아 포스트 코어군 모두에서 미세누출을 보였고, 이 중에서 지르코니아 포스트와 열가압형 세라믹 코어군이 좀 더 큰 미세누출에 대한 저항성을 보였으며 화이버 포스트와 콤포짓트 레진 코어군, CAD/CAM 절삭형 지르코니아 포스트 코어군은 유사한 양상을 보였으나, 각 실험군 간에 통계적으로 유의한 차이는 인정되지 않았다. (P>.05)

어린이의 치과치료시 약물에 의한 진정요법 사용에 대한 실태조사 (A SURVEY OF SEDATION PRACTICES IN THE KOREAN PEDIATRIC DENTAL OFFICE)

  • 안소연;최병재;곽지윤;강정완;이제호
    • 대한소아치과학회지
    • /
    • 제32권3호
    • /
    • pp.444-453
    • /
    • 2005
  • 진정요법은 소아치과에서 사용하는 보상, 속박, 체계적 탈감작법(말-시범-시행), 친밀감 같은 통상의 방법으로는 환자의 반응이 개선되지 않아 일반적인 치과치료가 불가능할 때 사용하는 행동조절법이다. 최근 국내에서도 진정요법을 이용하는 사례가 증가하는 추세이나 그 기준이나 방법들에 대한 연구는 매우 부족한 상태이다. 미국소아치과학회의 진정요법에 관한 기준이 있기는 하지만 국내의 상황이 미국과 다르므로 한국에서의 연구가 필요하다. 이에 저자는 국내에 거주하고 있는 소아치과의사들을 대상으로 국내 소아치과에서의 진정요법 현황에 대한 실태를 조사, 그 결과를 정리하여 향후 소아치과 임상에서의 진정요법에 대한 임상 기준을 정하는데 기여하고자 국내에 거주하고 있는 대한소아치과학회 회원 573명을 대상으로 진정요법 사용 실태에 관한 설문지를 발송하여 이 중 회신을 한 220명의 설문을 분석하여 다음의 결과를 얻었다. 1. 응답자의 약 66%가 진정요법을 사용하고 있다고 답했다. 진정요법에 관한 이전 연구 결과와 비교해 볼 때, 국내 소아치과에서 진정요법의 사용빈도가 증가하였다. 2. 진정요법으로 치료를 결정하게 된 요인은 행동조절, 치료내용과 양, 보호자의 요구, 내원횟수, 전신질환의 순서이었다. 3. 진정요법으로 치료받는 환자의 연령은 만 3세가 가장 많았고, 만 4-5세, 만 2세 미만, 만 6-10세, 만 10세 이상의 순서로 조사되었다. 4. 진정요법 시 chloral hydrate는 60-70mg/kg, hydroxyzine은 10-40mg/kg(25mg/kg)을 사용하고 있었고, 경구 투여가 가장 선호하는 약물투여 경로였다. 5. 진정요법 시 사용하는 환자감시 방법은 피부나 손톱색 등의 관찰을 포함한 환자 평가와 맥박 산소측정기(pulse oximeter)를 통한 환자감시를 선호하는 것으로 조사되었다. 6. 진정요법을 사용하고 있다고 응답한 사람의 약 56%에서 심폐소생술 교육을 받은 것으로 조사되었다.

  • PDF

소아환자의 Midazolam의 정맥투여 용량에 따른 진정 효과에 관한 비교연구 (THE COMPARATIVE STUDY ON THE SEDATIVE EFFECT OF DIFFERENT INTRAVENOUS MIDAZOLAM DOSAGES FOR PEDIATRIC DENTAL PATIENTS)

  • 김은영;김종수;유승훈
    • 대한소아치과학회지
    • /
    • 제32권3호
    • /
    • pp.416-426
    • /
    • 2005
  • 소아환자는 치과치료시 다양한 방법의 진정요법이 요구된다. 정맥내 투여방법은 약효의 발현이 빠르고, 진정의 심도 및 시간을 술자의 의도대로 조절할 수 있다는 장점이 있다. Midazolam은 현재 의과 및 치과영역에서 성인의 진정요법에 가장 널리 쓰이며, 심혈관계와 호흡계에 대한 영향이 적은 진정 약제이다. 그러나 midazolam을 이용한 정맥내 진정요법의 소아치과에서의 사용에 대한 연구와 보고는 적은 편으로, 이에 본 연구에서는 소아환자에서의 midazolam을 이용한 정맥내 투여시 효과적이고 안전한 초기 투여용량에 관한 연구를 하고자 한다. 진정요법으로 2회 이상의 구치부 치료가 필요한 건강하고 비협조적인 행동을 보이는 16명의 환자를 대상으로 하였으며 평균연령은 $54.7{\pm}10.7$개월, 평균 몸무게는 $18.1{\pm}3.0kg$이었다. 술전 투약으로 0.3mg/kg, 최대 5mg의 midazolam을 근육내 투여 후 30~50%의 $N_2O-O_2$를 병용투여한다. 이중 맹검법에 의해 모든 환자는 두 번의 내원 중 임의로 한번은 0.1mg/kg(I군)을, 다른 한번은 0.2mg/kg(II군)의 초기 용량의 midazolam을 정맥내 투여하여 치료하였고, 추가투여시에는 초기용량의 1/2을 투여하였다. 치료시 환자의 생징후를 측정하였고, 행동양상은 Ohio State University Behavioral Rating Scale과 Automated Counting System을 사용하여 평가하였다. 술자는 Houpt가 제시한 기준을 응용하여 임상적 치료의 성공과 실패를 평가하였다. 몸무게에 대한 총 투여용량은 I군에서 0.16mg/kg, 2군에서 0.24 mg/kg 이었다. 생징후의 경우 두 군 모두 정상범위 내에서 안정된 상태를 보였고, 통계적으로 유의한 차이를 보이지 않았다(p>0.05). 행동양상평가에서 II군에서 바람직한 행동양상(Quiet)의 비율이 높았고, 임상적 성공률은 II군에서 높았으나, 두 군간 통계학적 유의차는 보이지 않았다(p>0.05). 작용 발현시간은 II군에서, 회복시간은 I군에서 빨랐고, 약물 투여 횟수는 I군에서 많았으나, 두 군간 통계학적으로 유의한 차이를 보이지 않았다(p>0.05).

  • PDF