• Title/Summary/Keyword: Dental prosthesis

Search Result 791, Processing Time 0.027 seconds

Effect of abutment superimposition process of dental model scanner on final virtual model (치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향)

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • Purpose: The purpose of this study was to verify the effect of the abutment superimposition process on the final virtual model in the scanning process of single and 3-units bridge model using a dental model scanner. Materials and methods: A gypsum model for single and 3-unit bridges was manufactured for evaluating. And working casts with removable dies were made using Pindex system. A dental model scanner (3Shape E1 scanner) was used to obtain CAD reference model (CRM) and CAD test model (CTM). The CRM was scanned without removing after dividing the abutments in the working cast. Then, CTM was scanned with separated from the divided abutments and superimposed on the CRM (n=20). Finally, three-dimensional analysis software (Geomagic control X) was used to analyze the root mean square (RMS) and Mann-Whitney U test was used for statistical analysis (${\alpha}=.05$). Results: The RMS mean abutment for single full crown preparation was $10.93{\mu}m$ and the RMS average abutment for 3 unit bridge preparation was $6.9{\mu}m$. The RMS mean of the two groups showed statistically significant differences (P<.001). In addition, errors of positive and negative of two groups averaged $9.83{\mu}m$, $-6.79{\mu}m$ and 3-units bridge abutment $6.22{\mu}m$, $-3.3{\mu}m$, respectively. The mean values of the errors of positive and negative of two groups were all statistically significantly lower in 3-unit bridge abutments (P<.001). Conclusion: Although the number of abutments increased during the scan process of the working cast with removable dies, the error due to the superimposition of abutments did not increase. There was also a significantly higher error in single abutments, but within the range of clinically acceptable scan accuracy.

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).

THE EFFECT OF INTERNAL IMPLANT-ABUTMENT CONNECTION AND DIAMETER ON SCREW LOOSENING

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Jang, Kyung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.379-392
    • /
    • 2005
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: (1) to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, (2) to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, (3) to compare the detorque values of regular and wide diameter implants and (4) to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32Ncm with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann-Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-II regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-II regular and wide implants showed higher detorque values than before(p<0.05).

AN EXPERIMENTAL STUDY ON THE HINGE AXIS POINT (Hinge Axis Point에 관(關)한 실험적(實驗的) 연구(硏究))

  • Jo, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.11-16
    • /
    • 1976
  • Casts are often transferred to the articulator by arbitrary means, because the method of locating the true hinge axis point thought to be a complicated and time consuming procedure, and because the importance and significance of the true hinge axis in the construction of dental prosthesis is not sufficiently understood. In this report, the author constructed the hinge axis locator and determined the variations in location of the true hinge axis points from the location of the hinge axis point determined by arbitrary means. For this report, the procedure was followed on 50 persons with normal occlusion and sound T.M.J. function, so 100 true hinge axis points were recorded and compared with the arbitrary hinge axis point. The results obtained were as follows. 1. The mean distance from the arbitrary hinge axis point to the true hinge axis point was as follows. Right; (O)5.17mm., (V)3.44mm., (H)3.55mm.. Left; (O)5.63mm., (V)3.95mm., (H)3.51mm.. 2. The percentage of true hinge axis points classified at intervals of 2mm was as follows. 0-2mm; 4%, 2-4mm; 21%, 4-6mm; 37%, 6-8mm; 26%, 8-10mm; 10%, Over 10mm; 2%. And only 50% of the 100 true hinge axis points were located within a 5mm. radius of the arbitrary hinge axis point. 3. Instead of transferring the casts to the articulator by arbitrary means, the careful location of the true hinge axis points is recommended to avoid potential sources of error in mounting casts.

  • PDF

A CLINICAL STUDY ON THE SATISFACTION OF COMPLETE DENTURE PATIENTS (총의치 환자의 만족도에 대한 연구)

  • Kim, Hyung-Woo;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.440-452
    • /
    • 1995
  • A success of complete denture prosthesis can be determined by the satisfaction degree of the dentist and the patient. There are many factors influencing on the satisfaction of the complete denture patients. The purpose of this study is to analyze the correlation between the masticatory satisfaction and clinical evaluation, and the speech satisfaction and clinical evaluation in complete denture patients. 79 patients(total 119 complete dentures) were examined in this study who were treated in Seoul National University Dental Hospital. Through clinical evaluation, 2 examiners evaluated sex, age, edentulous period, the years of having used present complete denture, the number of the previous dentures, the state of the opposite arch, retention, stability, support, occlusion, vertical dimension of the complete denture and the condition of the residual alveolar ridge. Through questionnaires concerned with mastication and speech, examiners evaluate the satisfaction degree of the patients. This study led to the conclusion that : 1. The satisfaction degree of the mastication was lower in older patients(p<0.001) and in patients whose present complete denture period was shorter(p<0.05). The satisfaction degree of the mastication in male was higher than in female patients(p<0.01). 2. The satisfaction degree of the mastication was high when the retention of the complete denture was good(p<0.05), and when the condition of the residual alveolar ridge was good(p<0.05). 3. The satisfacion degree of the speech was high when the retention of the complete denture was good(p<0.01). 4. The satisfaction degree of the mastication was higher in patients with upper and lower complete denture than in patients with single complete denture whose oppsite arch was unilateral partial denture(p<0.05).

  • PDF

OPTICAL EFFECTS OF NONMETALLIC POST AND CORE SYSTEMS ON ALL-CERAMIC CROWNS (비금속 포스트 코어가 전부도재관에 미치는 광학적인 영향)

  • Kim Sung-Won;Cho In-Ho;Lim Ju-Hwan;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.493-506
    • /
    • 2002
  • Recently as the esthetic concerns about dental prosthesis have been increased, the nonmetallic post and core systems have been introduced clinically to improve the color and the low optical transmittance of conventional casting metal post and core systems. The purpose of this study was to compare and analyze the optical transmittance and the shade changes of all-ceramic crowns with two nonmetallic post and core systems. The experimental groups were classified as follows : Total 27 specimens(9 samples in each group) were evaluated. Group I : Natural teeth as a control group Group II : CosmoPost and $Empress^{(R)}$ core (Ivoclar-Vivadent, Liechtenstein) Group III : $LIGHT-POST^{TM}$ and $LIGHT-CORE^{TM}$ (Bisco, U.S.A.) In all group, all-ceramic crowns were fabricated with the same shade of IPS $Empress^{(R)}$ II (Ivoclar-Vivadent, Liechtenstein) after abutment preparation, and then two kinds of spectrophotometers, UV 3101 PC (Shimadzu, Japan) and CM 503i (Minolta Co. Ltd. Japan), were used to measure the optical transmittance and the color value. The following results were obtained : 1. The optical transmittance of each group without all-ceramic crowns, was siginificantly decreased in order of Group III, I and II (p<0.05). 2. The optical transmittance of each group with all-ceramic crowns cemented, were siginificantly decreased in order of Group I, II and III (p<0.05). 3. In comparison with the shade of all-ceramic crowns, there were no significant differences between groups regardless of the cementation. 4. In comparison with the shade changes in each group after the cementation of all-ceramic crowns, there were no significant differences between groups. From the above results, it is thought that the selection among materials used in this study doesn't influence greatly the esthetic restoration, because the differences of optical transmittance were so small that those were clinically insignificant.

Effect of different grinding burs on the physical properties of zirconia

  • Lee, Kyung-Rok;Choe, Han-Cheol;Heo, Yu-Ri;Lee, Jang-Jae;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.137-143
    • /
    • 2016
  • PURPOSE. Grinding with less stress on 3Y-TZP through proper selection of methods and instruments can lead to a long-term success of prosthesis. The purpose of this study was to compare the phase transformation and physical properties after zirconia surface grinding with 3 different grinding burs. MATERIALS AND METHODS. Forty disc-shaped zirconia specimens were fabricated. Each Ten specimens were ground with AllCeramic SuperMax (NTI, Kahla, Germany), Dura-Green DIA (Shofu Inc., Kyoto, Japan), and Dura-Green (Shofu Inc., Kyoto, Japan). Ten specimens were not ground and used as a control group. After the specimen grinding, XRD analysis, surface roughness test, FE-SEM imaging, and biaxial flexural strength test were performed. RESULTS. After surface grinding, small amount of monoclinic phase in all experimental groups was observed. The phase change was higher in specimens, which were ground with Dura-Green DIA and AllCeramic SuperMax burs. The roughness of surfaces increased in specimens, which were ground with Dura-Green DIA and AllCeramic SuperMax burs than control groups and ground with Dura-Green. All experimental groups showed lower flexural strength than control group, but there was no statistically significant difference between control group and ground with Dura-Green DIA and AllCeramic SuperMax burs. The specimens, which were ground with Dura-Green showed the lowest strength. CONCLUSION. The use of dedicated zirconia-specific grinding burs such as Dura-Green DIA and AllCeramic SuperMax burs decreases the grinding time and did not significantly affect the flexural strength of zirconia, and therefore, they may be recommended. However, a fine polishing process should be accompanied to reduce the surface roughness after grinding.

Use of Digital Smile Design in esthetic restoration in anterior teeth: A case report (전치부의 심미 수복을 위하여 Digital Smile Design을 적용한 증례)

  • Shin, Sejun;Noh, Kwantae;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.164-170
    • /
    • 2017
  • When restoring their anterior dentition, patients become more demanding on esthetics compared to posterior region during treatment planning phase. Digital Smile Design (DSD) procedure is performed in presentation software and digital photographs. This can widen diagnostic visualization and aid in transferring information between clinician, patient, and technician. This case presented is that of patient with dissatisfaction of his anterior old restoration. Retreatment procedures were carried out in two different manners: (1) using DSD protocol for diagnosis, smile simulation, communication and fabricating interim and definitive prosthesis by totally digitized workflow. (2) Using diagnostic wax-up for smile design and fabricating restorations by conventional workflow. Comparing two methods, DSD was easier to communicate between the dental team than the diagnostic wax-up method. But the final result obtained failed to meet total esthetic factors. Therefore, to obtain predictable esthetic results, more advanced design tool would be needed, including consideration of various esthetic factors besides successful communications.

Sinus bone graft and simultaneous vertical ridge augmentation: case series study

  • Kang, Dong-Woo;Yun, Pil-Young;Choi, Yong-Hoon;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.36.1-36.8
    • /
    • 2019
  • Background: This study aims to examine the outcome of simultaneous maxillary sinus lifting, bone grafting, and vertical ridge augmentation through retrospective studies. Methods: From 2005 to 2010, patients with exhibited severe alveolar bone loss received simultaneous sinus lifting, bone grafting, and vertical ridge augmentations were selected. Fifteen patients who visited in Seoul National University Bundang Hospital were analyzed according to clinical records and radiography. Postoperative complications; success and survival rate of implants; complications of prosthesis; implant stability quotient (ISQ); vertical resorption of grafted bone after 1, 2, and 3 years after surgery; and final observation and marginal bone loss were evaluated. Results: The average age of the patients was 54.2 years. Among the 33 implants, six failed to survive and succeed, resulting in an 81.8% survival rate and an 81.8% success rate. Postoperative complications were characterized by eight cases of ecchymosis, four cases of exposure of the titanium mesh or membrane, three cases of periimplantitis, three cases of hematoma, two cases of sinusitis, two cases of fixture fracture, one case of bleeding, one case of numbness, one case of trismus, and one case of fixture loss. Prosthetic complications involved two instances of screw loosening, one case of abutment fracture, and one case of food impaction. Resorption of grafted bone material was 0.23 mm after 1 year, 0.47 mm after 2 years, 0.41 mm after 3 years, and 0.37 mm at the final observation. Loss of marginal bone was 0.12 mm after 1 year, and 0.20 mm at final observation. Conclusions: When sinus lifting, bone grafting, and vertical ridge augmentation were performed simultaneously, postoperative complications increased, and survival rates were lower. For positive long-term prognosis, it is recommended that a sufficient recovery period be needed before implant placement to ensure good bone formation, and implant placement be delayed.

TREATMENT OF A PATIENT WITH CLEIDOCRANIAL DYSPLASIA USING IMPLANT-SUPPORTED BAR OVERDENTURE: A CASE REPORT (바 피개의치를 이용한 쇄골두개이형성증 환자의 치료: 증례보고)

  • Jang, Jung-Hui;Song, Min-Seok;Kim, Hyeon-Min;Kim, Nam-Hun;Eom, Min-Yong;Koo, Hyun-Mo;Yi, Jun-Kyu;Jeong, Jong-Cheol;Kim, Se-Woong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.1
    • /
    • pp.80-86
    • /
    • 2006
  • Cleidocranial dysplasia is rare inherited skeletal dysplasia. It was first reported by Martin in 1765. Subsequently, Marie and Sainton independently documented the criteria of the disease. Cleidocranial dysplasia is a bone disorder caused by a defect in the CBFA1 gene of chromosome 6p21. This gene guides osteoblastic differentiation and appropriate bone formation. Patient with cleidocranial dysplasia has maxillary deficiency, high and narrow palate, prolonged retention of primary teeth, unerupted permanent teeth and supernumerary teeth. Therapeutic options in these patients include of autotransplantation of selected impacted teeth, forced eruption of permanent teeth, full denture, overdenture and implant-supported prosthesis. We report a patient with cleidocranial dysplasia. This patient was treated with implant supported bar overdenture. Despite of gene defect that affects osteoblastic activity, bone remodeling and osseointegration occurred in our patient. So, we report this case with review of literature.