• Title/Summary/Keyword: Dental prostheses

Search Result 370, Processing Time 0.024 seconds

Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective study

  • Lee, Ki-Young;Shin, Kyung Su;Jung, Ji-Hye;Cho, Hye-Won;Kwon, Kyung-Hwan;Kim, Yu-Lee
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.2
    • /
    • pp.133-142
    • /
    • 2020
  • Objectives: In this study, we determined the incidence and pattern of screw loosening in patients who received dental implants. Materials and Methods: Patients who received implants between January 2008 and October 2013 and completed their prosthetic rehabilitation were evaluated for the incidence, frequency, and onset of screw loosening using dental charts and radiographs. The association between each factor and screw loosening was analyzed using the chi-square test and a multivariate analysis with binary logistic regression models (P<0.05). Results: Total 1,928 implants were placed in 837 patients (448 males, 389 females), whose follow-up period after loading varied from 0.25 to 70 months (mean period, 31.5 months). Screw loosening occurred in 7.2% of implants. Most cases occurred less than six months after loading. Among those, 22.3% experienced recurrent screw loosening. Screw loosening was most common in the molar region (8.5%) and frequently associated with an implant diameter of ≥5 mm (14.2%). External implant-abutment connections (8.9%) and screw-retained implant prostheses (10.1%) showed higher incidence of problems than internal implant-abutment connections and cement-retained implants, respectively. Screw loosening was most common in implant prostheses with single crowns (14.0%). Conclusion: Within the limits of the current study, we conclude that the incidence of screw loosening differs significantly according to the position of implant placement, the type of implant and manufacturer, implant diameter, the type of implant-abutment connection, the type of retention in the implant prosthesis, and the type of implant prosthesis.

RADIOGRAPHIC EVALUATION OF BONE CHANCE AROUND OSSEOINTEGRATED IMPLANTS IN PARTIALLY EDENTULOUS JAWS WITH FIXED TISSUE-INTEGRATED PROSTHESES (부분무치악 환자에서 기능하중노출이 골유착성 임플란트 주위의 치조골 소실에 미치는 영향에 관한 방사선학적 연구)

  • Yang, Soon-Bong;Han, Dong-Hoo;Yang, Ja-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.70-84
    • /
    • 1996
  • This paper reports marginal bone loss around osseointegrated implants after loading in partially edentulous patients in dental hospital, Yonsei University. Two types of implants($Br{\aa}nemark^{TM},\;IMZ^{TM}$) were used. Through the digital measurement on periapical radiograph around 37 implants in human subjects, marginal bone loss was observed for 24 months after delivery of prostheses. The results were as follows; 1. According to experimental periods marginal bone loss in total implants was 1.775 mm at 12 months, 1.921 mm at 24 months after delivery of prostheses(p<0.05). 2. Marginal bone loss in the $Br{\aa}nemark$ implants was 1.831 mm at 12 months, 1.833 mm at 24 months after delivery of prostheses(p<0.05). 3. Marginal bone loss in the IMZ implants was 1.578 mm at 12 months, 2.907 mm at 23 months after delivery of prostheses(p<0.05). 4. During the first year after loading, the IMZ implants showed less marginal bone loss than the $Br{\aa}nemark$ implants but, during the next the $Br{\aa}nemark$ implants showed less than the IMZ implants(p>0.05). These results indicate that marginal bone loss around osseointegrated implants occurs within the first 12 months after delivery of prostheses and stabilizes thereafter, so it is necessary to be careful of using dental implants for the first year after delivery of prostheses.

  • PDF

Comparison of the accuracy of digital impressions and traditional impressions: Systematic review (디지털 인상법과 전통적 인상법의 정확도 비교: 체계적 고찰)

  • Kim, Kyoung-Rok;Seo, Kweonsoo;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.258-268
    • /
    • 2018
  • Purpose: This study systematically examines literatures on the suitability of prostheses and accuracy of obtained impressions to see if digital impressions using intraoral scanners can replace traditional impressions. Materials and methods: A MEDLINE/PubMed search and manual search was performed for studies written in English about accuracy of digital impression published in dental journals from August 1, 1997, to July 31, 2017. Depending on criteria, the data for the selected articles were independently organized into standardized spreadsheets by 2 reviewers. Results: Among the total 35 studies met the inclusion criteria, there were 26 studies comparing the suitability of prostheses, and 9 studies comparing the accuracy of impressions through scan data without prostheses. Most studies used prostheses to compare the accuracy of impression techniques. Conclusion: This review suggests that making single crown or mesio-distally short prostheses with digital impressions is clinically reliable in natural teeth. However, there is still a limit to making mesio-distally long prostheses with digital impressions from the lack of related studies. Digital impression cannot fully replace traditional impressions in implant prostheses yet.

An evaluation of quality of dental prostheses printed by dental 3-dimensional printing system (치과용 3D 프린팅 시스템에 의해 출력된 보철물의 품질 평가)

  • Han, Man-So
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.185-191
    • /
    • 2016
  • Purpose: The purpose of this study were to evaluate the quality of dental prostheses printed by 3-dimensional printing system. Methods: Mater model was prepared and ten study models were fabricated. Ten single crowns were printed by 3D-printing system(Resin group) and another ten single crowns using casting method were manufactured(Metal group). The marginal adaptation of single crowns were measured using by silicone replica technique. Silicone replicas were sectioned four times. The marginal adaptations were evaluated using by digital microscope. Statistical analyses were performed with Mann-Whitney test(${\alpha}=0.05$). Results: $Mean{\pm}standard$ deviations of all marginal adaptations were $92.1(20.0){\mu}m$ for Metal group and $69.7(12.3){\mu}m$ for Resin group. Two groups were no statistically significant differences(p>0.05). Conclusion: Marginal adaptation of single crowns printed by 3D-printing system were ranged within the clinical recommendation.

Evaluation of clinical adaptation of dental prostheses printed by 3-dimensional printing technology (3D 프린팅 기술로 출력된 치과 보철물의 임상적 적합도 평가)

  • Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Purpose: The objectives of this study was to evaluate clinical adaptation of dental prostheses printed by 3 dimensional(3D) printing technology. Methods: Ten study models were prepared. Ten specimens of experimental group were printed by 3D printing(3DP group). As a control group, 10 specimens were fabricated by casting method on the same models. Marginal gaps of all specimens were measured to evaluate clinical adaptation. Marginal adaptations were measured using silicone replica technique and measured at 8 sites per specimen. Wilcoxon's signed-ranks test was used for statistical analysis(${\alpha}=0.05$). Results: Means of marginal adaptations were $95.1{\mu}m$ for 3DP group and $75.9{\mu}m$ for CAST group(p < 0.000). Conclusion : However, the mean of the 3DP group was within the clinical tolerance suggested by the previous researchers. Based on this, dental prosthesis fabricated by 3D printing technology is considered to be clinically acceptable.

Complication and Failure Analysis of Endodontically Treated Teeth Restored with Post and Cores (포스트로 수복한 근관 치료된 치아의 임상적 상태에 대한 평가)

  • Yun, Mi-Jung;Kim, Mu-Hyon;Jeong, Chang-Mo;Huh, Jung-Bo;Jeon, Yeong-Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.359-370
    • /
    • 2012
  • The endodontically treated tooth is generally restored with post and core, owing to the brittle and the loss of large amount of tooth structure. The purpose of this study was to evaluate the clinical status of fixed prostheses to improve the quality of dental care. In order to assess the clinical status of fixed prostheses, a total of 101 individuals (aged 30-89, 66 women and 35 men loaded with 125 fixed prostheses) who treated in the Department of Prosthodontics, Pusan National University Dental Hospital, between January 1990 to December 2005 were examined. The results of this study were as follows: 1. Length of service of fixed prostheses was $9.7{\pm}3.4$ years (mean), 11.1 years (median). 2. Age and sex of patient was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 3. Location of fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was low in anterio-posterior combination region (median:9.2 years). 4. Longevity of fixed prostheses made of base metal ceramic(median:12.0 years) and noble metal ceramic (median:11.3 years) is long (P<.05). 5. Number of units in fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 6. Condition of opposing dentition was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 7. Dental caries, periapical disease, tooth fracture were frequent complications. In 51.9% of the cases, abutment state after removing fixed prostheses was needed to be extracted.

Complete mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and dental CAD-CAM (완전 무치악 환자에서 임시 의치와 치과용 CAD-CAM을 활용한 전악 고정성 임플란트 회복 증례)

  • Jeon, Sol;Yoon, Hyung-In;Lee, Jae-Hyun;Yeo, In-Sung Luke;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.100-109
    • /
    • 2022
  • Installation of dental implants at optimal angles and positions is critical in long-term stable implant-supported restorations. Surgery and prosthodontic procedures should be performed accurately as the treatment is planned. In this clinical case, Computer aided design and manufacturing technology was used not only to establish a precise surgical plan, but also to fabricate both provisional and definitive fixed prostheses. A surgical guide was designed to install the implants at proper positions for the definitive prostheses. The patient's esthetic information, which was necessary for the new provisional and definitive fixed prostheses, was obtained from the existing temporary dentures. Finally, the complete mouth fixed implant-supported rehabilitation using monolithic zirconia provided the patient with functionally and esthetically satisfactory prostheses.

Considerations of Occlusion for Implant-Supported Fixed Prostheses (임상가를 위한 특집 1 - 임플란트 고정성 보철물의 교합적 고려사항)

  • Lee, Kyu-Bok
    • The Journal of the Korean dental association
    • /
    • v.51 no.5
    • /
    • pp.242-249
    • /
    • 2013
  • The proper occlusal design is one of the most important factors for the long-term success. The purpose of this research is to investigate and define occlusal considerations to reduce failure of implant-supported fixed prostheses. The physiological movement of implants is markedly lower than that of natural teeth and they also lack in occlusal sensitivity. Proper occulsal pattern may be assigned to compensate for the biological disadvantages and occlusal contacts must be formed where the cantilever effect is minimized. Moreover, the long-term success can be assured by reducing early occulsal loading to avoid implant overloading and selecting appropriate occlusion material.

Food impaction related with trauma from occlusion (임플란트 보철물의 식편압입: 교합적 원인분석과 대처)

  • Cho, Lee-Ra
    • The Journal of the Korean dental association
    • /
    • v.52 no.8
    • /
    • pp.491-505
    • /
    • 2014
  • Food impaction between the implant prostheses and adjacent teeth is the most frequently observed problem. It may be caused by the migration of the adjacent teeth. This symptom may be observed at the mesial aspect of implant prostheses especially, and related with the multiple contributing factors including teeth vitality and antagonist. Idal proximal contact with optimal strength and shape should be made for preventing the food impaction. Shape of customized abutment and prosthesis should have optimal emergence profile. Long duration from the extraction to the delivery of implant prostheses, the adjacent teeth and antagonist teeth may have possibility of occlusal interferences. Remained teeth mobility can induce the food impaction regardless of interproximal contact strength. Occlusal adjustment to remove occlusal interferences can be a method for enhancing the stability of interproximal contact.

Application and consideration of digital technology for removable complete denture (총의치 제작에 적용 가능한 디지털 기술과 임상적 고찰)

  • Lee, Jung-Jin;Song, Kwang-Yeob;Park, Ju-Mi
    • The Journal of the Korean dental association
    • /
    • v.57 no.9
    • /
    • pp.534-543
    • /
    • 2019
  • Digital technology has changed various aspects of the clinical dentistry. The intraoral scanner and Computer-aided design / Computer-aided manufacturing (CAD-CAM) technology are widely used in fabricating fixed prostheses and in implant surgery. These technologies greatly improved the efficiency of clinical and laboratory procedures. With all newly introduced software, devices, and clinical studies, digital technology has been actively applied in removable prostheses. It is now possible to fabricate the removable prostheses more quickly and easily through subtractive and additive manufacturing. Various clinical and laboratory protocols were introduced by many manufacturers. The purpose of this review is to summarize the literature on digital technology for fabricating complete denture with current status and future perspectives.

  • PDF