• 제목/요약/키워드: Dental polishing

검색결과 136건 처리시간 0.024초

치과기공실(齒科技工室)의 작업공정별(作業工程別) 소음(騷音)에 관한 연구(硏究) (A Study on the Noise by working Process in Dental Laboratory)

  • 남상용
    • 대한치과기공학회지
    • /
    • 제15권1호
    • /
    • pp.27-41
    • /
    • 1993
  • Degree of noise by personal dental laboratory working process and degree of noise by complex dental laboratory working process were measured separtely. The time of exposure to noise greater than 70dB was analyzed. Then, the whole degree of noise in dental laboratory was estimated on the basis of afore-mentioned information. Questionaire were employed to investigate the mental, emotional and physiological effects of noise in dental technicians, The purpose of this study was to provide basic information on keeping dental techneicans who are exposed to noise pollution in good working condition and good health. Results obtained are as follows ; 1. Polishing process in each working part showed high degree of noise greater than 70dB in terms of degree of noise by personal working. 2. Degree of noise by complex working process in each working part was greater than that of personal working process. 3. Time of exposure to noise complex working process the part of porcelain 150min, partial denture 120 min, crown and bridge 100 min, full denture 80 min. 4. Degree of noise by time in dental laboratory was 80dB in general for polishing process and below 75dB for waxing process. 5. Effects of noise on mental and emotional state of dental technicians showed that they felt irritated every day(14%), irritated once in a while(29%) and easily ger mad(19%). 6. Effects of noise on heart and stomach were hyper-gastric acid(38%), gastric ulcer(11%), gastritis(5%), deuodenal ulcer(3%) and weak heart function(32%). 7. Effects of noise in the hearing ability were weak(39%), moderate(33%) and normal(14%) Data presented in this study demonstrated that noise in the dental laboratory exerts profound effect on dental technicians mentally, physiologically and emotionally, in light of the above results, therefore, it appears advisable to devots substantial on the management of working condition and put further(continuing) efforts in the investigation for reducing noise problem.

  • PDF

THE EFFECT OF SURFACE FINISHES ON FLEXURAL STRENGTH, FRACTURE TOUGHNESS OF FELDSPATHIC DENTAL PORCELAIN

  • Chang, Il-Sung;Lee, Sun-Hyung;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.293-305
    • /
    • 2005
  • Statement of problems. Conventional feldspathic porcelain is used extensively as a restorative material and it is subjected to grinding and polishing during fabrication and delivery procedures. There is still considerable controversy concerning the best methods to achieve the strongest porcelain restorations after such adjustments. Purpose. The objective of this study was to investigate the effects of (1) overglazing, (2) selfglazing, and (3) fine polishing on the flexural strength and fracture toughness of feldspathic dental porcelain. Material and method. Ninety porcelain disks were prepared for flexural strength test and sixty porcelain disks were fabricated for fracture toughness test. Specimens were divided into three groups for each test as follows: 1) overglazed 2) self-glazed 3) polished. The flexural strength of feldspathic porcelains was determined by ring-on-ring biaxial flexural strength test. The fracture toughness values of three experimental groups were obtained by indentation fracture toughness test. Results. The flexural strength of overglazed group was significantly higher than that of selfglazed and polished group (P<0.05), while the difference between self-glazed and polished group was not significant (P>0.05). The fracture toughness values of overglazed and polished group were significantly higher than that of self-glazed group (P<0.05), while the difference between overglazed and polished group was not significant (P>0.05). Conclusions. This results supported the use of polishing as an alternative to glazing metal ceramic restorations, as it was not detrimental in flexural strength and fracture toughness. But, under the conditions of this study, overglazing was the ideal surface finishing method of feldspathic dental porcelain.

치기공과 학생들의 실습 중 안전에 대한 안전교육 요구도 특성 (Safety education needs among the dental technology-major college students to prevent injuries in their laboratory classes)

  • 박종희
    • 대한치과기공학회지
    • /
    • 제28권1호
    • /
    • pp.177-198
    • /
    • 2006
  • This study purposed to offer basic data for safety education of the dental laboratory technology after the investigation of how much the students in the dept. of dental laboratory technology are aware of the danger of each instrument, equipment or laboratory procedure that they use during laboratory and how much they demand safety education for this. The objects for this study were 423 students who were in the dept. of dental laboratory technology. In this regard, four colleges which have the dept. of dental laboratory technology were randomly selected to do a questionnaire survey. SPSS 12.0 was used to analyze the collected data. The results were as follows: As for satisfaction with their major, the respondents answered Satisfied (59.1%), Average (35.5%) and Dissatisfied (5.4%). In terms of the production process of a partial denture, they considered casting, polishing the casting body, polishing denture and burn out were most dangerous in order. As for the production process of a full denture, what they regarded as the most dangerous in order was polishing denture, deflasking and wax wash. Regarding the laboratory procedures of porcelain material, casting, trimming casting body, polishing porcelain material and burn out were the most dangerous procedures that they perceived. With regard to materials for use, alcohol, polishing, metal and wire were the most dangerous ones they thought. As for the handling characteristics of each material, small towns showed a higher demand for safety of the handling characteristics of alcohol. In terms of school year and sex, juniors and girls had higher scores in the demand for safety of the handling characteristics of acid. Regarding the handling characteristics of each equipment and instrument, all of small towns, juniors and girls showed the highest demand for safety of the handling characteristics of alcohol lamps. With regard to scores in the demand for safety of other characteristics, all of small towns, juniors and girls had the highest demand for safety of emergency treatment. Concerning the demand for safety education by the completion of safety education, in terms of each material, highest was the demand for safety of acid from the group which completed safety education. In regard to equipments and instruments, when it came to the demand for safety of the handling characteristics of casting machine, the educated group's demand for safety of acid was higher. Regarding other characteristics, the group which was not educated gained higher scores in the demand for safety of emergency treatment. 11. In all areas(materials, machines and others), small towns, girls and juniors showed higher scores in the demand for safety. Based on the above results, it was found that when students conduct the laboratory of dental technology, they would think that many materials, instruments or equipments for use are very dangerous. However, safety education was not fully given to them. Regarding the scores in the damned for safety education, the highest was 4.16 and the lowest was 3.43, which suggests that the scores were generally very high. In this regard, it is necessary to continue delivering a systematic safety education of materials, equipments or instruments used during the laboratory of dental technology. Therefore, through the analysis of each material, instruments or facility used in every laboratory and each process, safety accident types and accident risk factors should be investigated to develop educational materials for this. Moreover, it is required to open safety education as a single course of study or insert safety contents of all materials and machines into the class of dental laboratory instrument or dental materials for the purpose of a systematic and thorough safety education to prevent a safety accident during laboratory.

  • PDF

The effects of surface grinding and polishing on the phase transformation and flexural strength of zirconia

  • Lee, Ji-Young;Jang, Geun-Won;Park, In-Im;Heo, Yu-Ri;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.1-6
    • /
    • 2019
  • PURPOSE. The purpose of this in vitro study was to evaluate the effect of surface grinding and polishing procedures using high speed zirconia diamond burs with different grit sizes on the phase transformation and flexural strength of zirconia. MATERIALS AND METHODS. Forty disc shape specimens ($15{\times}1.25mm$) with a cylindrical projection in the center of each disc ($1{\times}3mm$) were fabricated with 3Y-TZP (Prettau, Zirkonzahn, Italy). The specimens were divided into 4 groups (n=10) according to the grinding and polishing procedures: Control group - grinding (coarse-grit diamond bur), Group 1 - grinding (coarse-grit diamond bur) + polishing, Group 2 - grinding (fine-grit diamond bur) + polishing, and Group 3 - grinding (fine grit diamond bur). Each specimen was analyzed by 3D-OM, XRD analysis, and biaxial flexural strength test. RESULTS. Based on the surface morphology by 3D-OM images, polished specimens showed smoother surface and lower roughness value (Ra). In the result of XRD analysis, partial phase transformation from tetragonal to monoclinic zirconia occurred in all groups. Control group, ground with a coarse grit diamond bur, showed more $t{\rightarrow}m$ phase transformation and lower flexural strength than Groups 1 and 2 significantly. CONCLUSION. The flexural strength in all specimens after grinding and polishing showed over 500 MPa, and those were clinically acceptable. However, grinding with a coarse grit diamond bur without polishing induced the phase transformation and low strength. Therefore, surface polishing is required for the occlusal adjustment using a high speed zirconia diamond bur to reduce the phase transformation and to prevent the decrease of flexural strength of zirconia.

Clinical and microbiological effects of the supplementary use of an erythritol powder air-polishing device in non-surgical periodontal therapy: a randomized clinical trial

  • Park, Eon-Jeong;Kwon, Eun-Young;Kim, Hyun-Joo;Lee, Ju-Youn;Choi, Jeomil;Joo, Ji-Young
    • Journal of Periodontal and Implant Science
    • /
    • 제48권5호
    • /
    • pp.295-304
    • /
    • 2018
  • Purpose: This study was undertaken to evaluate the clinical and microbiological effects of an erythritol powder air-polishing device (EPAP) as a supplement to scaling and root planing (SRP) therapy in patients with moderate chronic periodontitis. Methods: Clinical and microbiological evaluations were performed at 21 sites treated with SRP (control) and 21 sites treated with SRP+EPAP (test). All examinations were performed before treatment, 1 month after treatment, and 3 months after treatment. Results: There were no significant clinical differences between the test group and the control group. Microbiological analysis revealed that the relative expression level of Porphyromonas gingivalis was significantly lower in the test group than in the control group at 1 month after treatment. Clinical and microbiological results showed improvements at 1 month compared to baseline; in contrast, the results at 3 months after treatment were worse than those at 1 month after treatment. Conclusions: In this study, both SRP and SRP+EPAP were clinically and microbiologically effective as non-surgical periodontal treatments. In particular, the SRP+EPAP group showed an antimicrobial effect on P. gingivalis, a keystone bacterium associated with the onset of chronic periodontitis, in a short-term period. Periodic periodontal therapy, at intervals of at least every 3 months, is important for sustaining the microbiological effects of this treatment.

치과 도재용 합금과 도재간의 결합력에 관한 연구 (Study of the Bond Strength Between Dental Ceramic Alloys and Porcelain)

  • 윤일중
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.29-37
    • /
    • 1981
  • The bond strengths with ceramco porcelain were compared between precious alloy S, and non-precious alloys V.U. and R. And the changes in bond strengths of non-precious alloys with ceramco porcelain, according to surface preparations by sand blasting, longitudinal grinding, transverse grinding, and high polishing, were studied. The test specimens were prepared by firing porcelain doughnuts on the surface prepared alloy rods, and investing in dental stone. The specimens were subjected to shear loading forces. The conclusions drawn from the investigation are as follows: 1. The bond strengths with ceramco porcelain were higher in the non-precious alloys U and R, than in the precious alloy S. 2. The bond strengths were in descending order for R alloy, U alloy, V alloy, and S alloy. 3. The bond strengths were highest when the R alloy and U alloy were surface prepared by sand blasting. 4. All bond strength values were lowest when the alloy surfaces were prepared by high polishing.

  • PDF

치기공과 실습 중 안전사고 실태조사 II (Accident research II for the college students happened during Dental Laboratory Technology-major classes)

  • 박종희
    • 대한치과기공학회지
    • /
    • 제27권1호
    • /
    • pp.131-153
    • /
    • 2005
  • The purpose of this study was to identify the accidents happened in the college dental laboratory technique classes and to realize the level of safety education for the dental laboratory technique major students. The research data were collected from a self-administered survey distributed to the conveniently selected college students whose majors were dental laboratory technology in Suwon, Daejeon, Daegu, Kimcheon, and Icsan. The study participants were 422 freshmen, sophomore and junior students in the selected cities. All collected survey responses were encoded and analyzed in SPSS 12.0. The findings were as follows. 1. The students who had any accidents in their laboratory classes were 36% and the other 64% answered 'no.' 2. Most injuries which the participants had were not significant. 3. The medical treatment periods of most injury cases were less than one week; however, approximately 20% of the self-reported injury cases reported that their treatment periods were longer than one week. 4. The body parts frequently injured from accidents were hands with 84.7% and arms, eyes, face, head, and legs in order. 5. Concerning the materials involved in the laboratory classes, most accidents happened when working with wax in 59.9%, with plaster in 52.3%, with wire in 39.8%, with alcohol in 34.6%, and casting iron in 22.2% in order. 6. The accident-prone laboratory methods were polishing with 53.5%, pickling or sanding with 17.4%, and casting or burning with 5.8% in order. 7. Most students wore their laboratory gowns well; however, few students wore mask before dust-involved jobs. Furthermore, only 57.1% students answered their laboratory fans worked during the polishing job. 8. Approximately 54% participant students answered that they took laboratory safety education when necessary only from the class instructors. 9. The 76.1% students responded that they needed laboratory safety education at least 1-2 times every semester. 10. The survey participants answered that the primary factors for injury prevention in their laboratory were taking safety education, wearing safety equipments, and providing safety-focused facilities. Concludingly, comprehensive evaluation and monitoring for potential risk factors from both the human side and the environment side should be continually provided to minimize the college laboratory accidents.

  • PDF

The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics

  • Sagsoz, Omer;Demirci, Tevfik;Demirci, Gamze;Sagsoz, Nurdan Polat;Yildiz, Mehmet
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.417-422
    • /
    • 2016
  • PURPOSE. The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics, comparing it with that of a glazed glass-ceramic. MATERIALS AND METHODS. Four different CAD/CAM ceramics (feldspathic ceramic: C-CEREC Blocs, (SIRONA) and three resin-ceramics: L-Lava Ultimate, (3M ESPE), E-Enamic, (VITA) and CS-CeraSmart, (GC)) and one light cure composite resin: ME-Clearfil Majesty Esthetic (Kuraray) were used. Only C samples were glazed (gl). Other restorations were divided into four groups according to the polishing technique: nonpolished control group (c), a group polished with light cure liquid polish (Biscover LV BISCO) (bb), a group polished with ceramic polishing kit (Diapol, EVE) (cd), and a group polished with composite polishing kit (Clearfil Twist Dia, Kuraray) (kc). Glazed C samples and the polished samples were further divided into four subgroups and immersed into different solutions: distilled water, tea, coffee, and fermented black carrot juice. Eight samples ($8{\times}8{\times}1mm$) were prepared for each subgroup. According to CIELab system, four color measurements were made: before immersion, immersion after 1 day, after 1 week, and after 1 month. Data were analyzed with repeated measures of ANOVA (${\alpha}=.05$). RESULTS. The highest staining resistance was found in gl samples. There was no difference among gl, kc and cd (P>.05). Staining resistance of gl was significantly higher than that of bb (P<.05). Staining resistances of E and CS were significantly higher than those of L and ME (P<.05). CONCLUSION. Ceramic and composite polishing kits can be used for resin ceramics as a counterpart of glazing procedure used for full ceramic materials. Liquid polish has limited indications for resin ceramics.

Color stability of bulk-fill and incremental-fill resin-based composites polished with aluminum-oxide impregnated disks

  • Koc-Vural, Uzay;Baltacioglu, Ismail;Altinci, Pinar
    • Restorative Dentistry and Endodontics
    • /
    • 제42권2호
    • /
    • pp.118-124
    • /
    • 2017
  • Objectives: This study aimed to evaluate the color stability of bulk-fill and nanohybrid resin-based composites polished with 3 different, multistep, aluminum-oxide impregnated finishing and polishing disks. Materials and Methods: Disk-shaped specimens (8 mm in diameter and 4 mm in thickness) were light-cured between two glass slabs using one nanohybid bulk-fill (Tetric EvoCeram, Ivoclar Vivadent), one micro-hybrid bulk-fill (Quixfil, Dentsply), and two nanohybrid incremental-fill (Filtek Ultimate, 3M ESPE; Herculite XRV Ultra, Kerr) resin-based composites, and aged by thermocycling (between $5-55^{\circ}C$, 3,000 cycles). Then, they were divided into subgroups according to the polishing procedure as SwissFlex ($Colt\grave{e}ne/Whaledent$), Optidisc (Kerr), and Praxis TDV (TDV Dental) (n = 12 per subgroup). One surface of each specimen was left unpolished. All specimens were immersed in coffee solution at $37^{\circ}C$. The color differences (${\Delta}E$) were measured after 1 and 7 days of storage using a colorimeter based on CIE Lab system. The data were analyzed by univariate ANOVA, Mann-Whitney U test, and Friedmann tests (${\alpha}=0.05$). Results: Univariate ANOVA detected significant interactions between polishing procedure and composite resin and polishing procedure and storage time (p < 0.05). Significant color changes were detected after 1 day storage in coffee solution (p < 0.05), except Quixfil/Optidisc which was color-stable after 7 days (p > 0.05). Polishing reduced the discoloration resistance of Tetric EvoCeram/SwissFlex, Tetric EvoCeram/Praxis TDV, Quixfil-SwissFlex, and all Herculite XRV Ultra groups after 7 days storage (p < 0.05). Conclusions: Discoloration resistance of bulk-fill resin-based composites can be significantly affected by the polishing procedures.

연마시스템에 따른 복합레진의 표면거칠기와 연마시간에 대한 평가 (The evaluation of surface roughness and polishing time between polishing systems)

  • 김예미;신수정;송민주;박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제36권2호
    • /
    • pp.119-124
    • /
    • 2011
  • 연구목적: 본 실험은 현재 임상에서 사용되고 있는 4가지 복합레진 연마 시스템의 연마 능력과 연마에 걸리는 시간을 평가하여 그 효율성을 알아보고자 하였다. 연구 재료 및 방법: 직경 4 mm, 높이 2 mm 의 테플론 몰드에 Z-250 (3M ESPE) 복합레진을 충전하고 양면을 슬라이드 글라스로 압접한 후 Optilux 501을 이용하여 각 면을 40초씩 중합하였다. 중합된 복합레진 디스크를 분리하고 #320 사포로 연마하여 동일한 거친면을 형성한 후 다음의 4가지 연마시스템을 이용하여 표면을 연마하였다: Sof-Lex (3M ESPE), Jiffy (Ultradent), Enhance (Dentsply/Caulk), and Pogo (Dentsply/Caulk). 연마된 면을 표면조도측정기를 이용하여 거칠기를 측정하고 연마에 소요된 시간을 측정하여 연마도와 효율성을 비교 평가하였다. 통계는 one-way ANOVA후 Duncan's multiple range test를 이용하여 군간의 비교를 하였다. 결과: 연마 후 표면조도는 Pogo에서 가장 낮게 나타났으며 Sof-Lex에서 가장 높게 나타났다. 연마에 소요된 시간은 Pogo에서 가장 짧게 걸렸으며 Sof-Lex, Enhance, Jiffy의 순으로 나타났다. 결론: One-step 연마 시스템인 Pogo는 복합레진의 연마에 있어 매우 짧은 시간에 매우 매끈한 면을 얻을 수 있는 것으로 나타나 수복물의 최종 연마에 매우 효율적으로 사용할 수 있는 것으로 평가되었다.