• Title/Summary/Keyword: Dental microscope

Search Result 561, Processing Time 0.032 seconds

Study on the Corrosin Properties of Au-Ag-Cu Dental Alloys (치과용 Au-Ag-Cu계 합금의 부식특성에 관한 연구)

  • Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.14 no.1
    • /
    • pp.23-43
    • /
    • 1992
  • Corrosion characteristics of four commerial gold-based dental alloys(C-1; Au75%, Ag13.9%, Pd3%, Cu & etc.,8.1%, C-2 ;Au 52.08, Ag 24%, Pd 5%, Cu & etc.,18.92, C-3 ; Au 53%, Ag 22%, Pd 5%, Pt 3% Cu & etc.,17%, C-4 ; Au 53%, Pd4, Pt1.5%, Ag & Cu & etc.,41.5%) and four experimental ternary Au-Ag-Cu alloys(E-1 ; Au 50%, Ag 30%, Cu 20%, E-2 ; Au 50%, Ag 20%, Cu 30%, E-3 ; Au 50%, Ag 10%, Cu 40%, E-4 ; Au 50%, Ag 40%, Cu 10%) were investigated by potentiodynamic polarization analysis and the structure was examined by optical microscope and SEM. All corrosion testing was conducted in 1% NaCl solution. The main results are as follows : 1. The corrosion resistence of commercial alloys was decreased in the order of C-1, C-3, C-4, C-2. C-2. 2. The E-1 and E-3 ternary alloys exhibits the higher corrosion resistence than E-2 and E-4 alloys. 3. The cast microstructure of alloys reveals dendrite morphology which shows the significant microsegregation caused by the difference in the diffusion rate between liquid and solid. 4. It is found that the surface corrosion products were mainly AgCl by X-ray diffraction results.

  • PDF

Corrosion Characteristics and Surface Morphologies of TiN and ZrN Film on the Abutment Screw by Arc-ion Coating(II) (어버트먼트 나사에 아-크 이온도금된 TiN과 ZrN피막의 부식특성과 표면 형상 (II))

  • Jeong, Y.H.;Kwag, D.M.;Chung, C.H.;Kim, W.G.;Choe, H.C.
    • Corrosion Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.212-217
    • /
    • 2011
  • In this study, corrosion characteristics of TiN and ZrN film on the abutment screw by arc-ion plating were investigated using a potentiodynamic anodic polarization test in deaerated 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The surface morphologies of the coating layers before and after corrosion test were investigated by a field-emission scanning electron microscope (FE-SEM) and a energy dispersive x-ray spectroscopy (EDS). The surfaces of the TiN and ZrN coated abutment screws showed the smooth surfaces without mechanical defects like scratches which can be formed during the manufacturing process, compared with those of the non-coated abutment screw. The corrosion and passive current densities of TiN and ZrN coated abutment screws were lower than those of the non-coated abutment screw.

Effects of TiN Coating on the Fatigue Fracture of Dental Implant System with Various Cyclic Loads

  • Jung, Da-Un;Chung, Chae-Heon;Son, Mee-Kyoung;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.6
    • /
    • pp.283-291
    • /
    • 2015
  • The purpose of this study was to investigate effects of TiN coating on the fatigue fracture of dental implant system with various cyclic loads. TiN coated abutment screw, the fixture, and abutment of internal hex type were prepared for fatigue test. The fatigue test was carried out according to ISO 14801:2003(E) using tensile and compression tester with repeated load from 30% to 80% of static fracture force. Morphology and fractured surface was observed by field emission scanning electron microscope(FE-SEM) and energy dispersive X-ray spectroscope(EDS). The fracture cycle drastically decreased as repeated load increased. Especially, in the case of TiN-coated abutment screw, fracture cycle increased compared to non-coated abutment screw. The fatigue crack was propagated fast as repeated load increased. The plastic deformation region decreased, whereas, cleavage fracture region increased as repeated load increased.

Histopathology and ultrastructural findings of pediatric sialolithiasis: a brief communication

  • Mustakim, Kezia Rachellea;Nguyen, Truc Thi Hoang;Eo, Mi Young;Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.2
    • /
    • pp.125-129
    • /
    • 2022
  • Sialolithiasis is a condition in which the salivary gland excretory duct is obstructed due to the formation of calcareous deposits and is uncommon in children compared to adults. The treatment modalities range from a conservative approach involving hydration to a surgical approach. Though several studies have analyzed the sialolith micromorphology structures, studies on pediatric sialoliths remain scarce. This brief communication aims to describe the sialolith micromorphology to understand the mechanism of mineralization and growth of pediatric sialoliths. A 6-year-old Korean female presented with swelling under her tongue. The intraoral examination revealed a painless yellowish hard mass beneath the tongue near the Wharton's duct which was suspected as a sialolith. After receiving the informed consent, the sialolithotomy was performed under local anesthesia. The obtained stone was analyzed through histopathology and transmission electron microscope examinations to understand the mechanism of mineralization and growth of pediatric sialolith. The micromorphology and growth processes of pediatric sialolith remain undescribed. More comprehensive microscopic studies are needed regarding their distinctive characteristics. By expanding knowledge about sialoliths micromorphology, development of new preventive, diagnostic and patient-tailored treatment methods of pediatric sialolithiasis will be enhanced.

A Study on the Enamel Erosion Caused by Energy Drinks (시판되는 에너지음료의 법랑질 침식효과에 대한 연구)

  • Jeong, Moon-Jin;Jeong, Soon-Jeong;Son, Jung-Hui;Chung, Sung-Kyun;Kim, A-Reum;Kang, Eun-Ju;Kim, Eun-Ju;Kim, Hye-In;Jang, Ko-Eun;Cho, Min-Hee;Cheon, Ye-Ji;Choi, Hyo-Jung;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.597-609
    • /
    • 2014
  • To find out the effect of commercially available energy drinks on tooth enamel erosion, analyzed pH, buffering capacity, and the content of some of the inorganic components selecting 4 energy drinks that has high affinity of the products currently being sold. In addition, by observing the degree of erosion before and after immersion in energy drink by surface microhardness and scanning electron microscope (SEM) the results were as follows: Acidity of energy drink 'Burn Intense' was the lowest as $2.78{\pm}0.01$ highest on distilled water as $6.475{\pm}0.01$. 'Burn Intense' buffering capacity was $3.48{\pm}0.155$ at pH 5.5, $1.88{\pm}0.15$ at pH 7.0 which is the highest, and 'Hot6' was $1.71{\pm}0.37$, $1.23{\pm}0.35$ on each of it showing the lowest points. Ca content on energy drink was the highest at 'Volt Energy' as ($77.21{\pm}2.70mg/kg$), the lowest at 'Hot6' as ($0.98{\pm}0.05mg/kg$). P content was the highest on 'Hot6'($1.34{\pm}0.05mg/kg$) and detected at 'Red Bull'. Enamel surface hardness variation of the energy drinks before and after immersion showed rapid decrease at 'Red Bull' ($66.65{\pm}35.60$), and 'Volt Energy' ($61.96{\pm}31.42$), 'Burn Intense' ($58.53{\pm}24.84$), 'Hot6' ($53.99{\pm}60.26$) was in order. Distilled water, the control group, showed significant difference with the experimental group (p<0.05). But there was no significant difference between energy drinks. At SEM observation and analysis, 'Burn Intense' was the most severe demineralization, 'Volt Energy', 'Hot6', 'Red Bull', distilled water was in order. In the above results, taken together there were no statistically differences between energy drinks but significant difference in comparison with distilled water. In addition, at SEM observation and analysis all energy drink caused dental erosion, especially 'Burn Intense', has the lowest acidity, was serious. Thus, it is believed to provide a variety of oral health education and information about energy drinks that can affect the erosion of the teeth so public have the right to be recognized and reasonable dental care.

THE EFFECT OF AUTOLOGOUS PLATELET-RICH PLASMA (PRP) ON BONE FORMATION AROUND DENTAL IMPLANT IN THE RABBIT: A HISTOMOR-PHOMETRIC AND REMOVAL TORQUE STUDY

  • Yi Yang-Jin;Yang Jae-Ho;Lee Sun-Hyung;Kim Yung-Soo;Kwon Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.659-681
    • /
    • 2001
  • Platelet-rich plasma(PRP) has been known to increase the rate and degree of bone formation by virtue of growth factors in concentrated platelets. Although its great healing effect on bone defect or pre-implantation site preparation in conjunction with bone substitute has been reported, the effect associated with implant is unknown. The purpose of this study was to investigate the effect of PRP on rapid osseointegration of endosseous dental implants in the rabbit tibiae. Twenty two adult female New Zealand white rabbits, weighing approximately 2.7-3.3kg, were used for this study. Twelve of the 22 animals were used for histomorphometric analysis and ten of the 22 were for removal torque test. Each animal received two implants in each tibia (two treated with PRP and two as control) and was given fluorochrome intramuscularly. For histomorphometric analysis, rabbits were divided into four groups according to the healing period. At 1 week, 2 weeks, 4 weeks and 8 weeks postoperatively, each three animals were sacrificed serially and the amount and rate of bone formation around dental implant were examined on the undecalcified sections under fluorescent microscope, polarized microscope and light microscope connected to a personal computer equipped with image analysis system. For removal torque test, rabbits were divided into two groups and removal torque tests were performed at 4 weeks, 10 weeks after implant placement. In total, 88 screw shaped, commercially pure titanium implants (Neoplant, Neobiotech, Seoul, Korea) were used in this study. Labeling pattern reflected differences of two groups in bone formation rate at each period. Histomorphometrically, PRP group showed significantly higher bone volume within threads compared to control group at 2 weeks ($70.30{\pm}4.96%$ vs. $50.68{\pm}6.33%$; P < .01) and 4 weeks ($82.59{\pm}5.94%$ vs. $72.94{\pm}4.57%$; P < .05 ). PRP group at 1, 2 and 4 weeks revealed similar degree of bone volume formation comparable to control group at 2, 4 and 8 weeks, respectively. On the other hand, while PRP group showed higher bone-implant contact ($47.37{\pm}8.09%$) than control group ($33.16{\pm}13.47%$) at 2 weeks, there were no significant differences between PRP group and control group for any experimental period. Removal torque values also showed no significant differences between PRP group and control group at any experimental period (P > .05). These findings imply that PRP could induce rapid, more bone formation around implant during early healing period and get faster secondary stability for reducing healing period, though it has not induced bone maturation enough to resist functional loading.

  • PDF

Evaluation of marginal and internal gap of wax coping fabricated by CAD/CAM system using intraoral scanner (구강 내 스캐너를 사용하여 CAD/CAM으로 제작된 왁스 코핑의 적합도 평가)

  • Kim, Dong-Yeon;Jung, Il-Do;Lee, Jae-Jun;Kim, Ji-Hwan;Kim, Myung-Bae;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of wax copings fabricated from extraoral scanning with intraoral scanning. Methods: Fifteen study models(abutment of teeth 16) were made by PMMA. STL files of thirty abutment were prepared by intraoral scanning with extraoral scanning. Wax copings of thirty fabricated using CAD/CAM system. Marginal and internal gap of wax copings of thirty were measured by silicone replica technique and digital microscope(${\times}140$). Date were analyzed by using independent samples t-test. Results: Mean (SD) of two group were measured $55.61(27.42){\mu}m$ for totally gap of ES group and $60.67(33.14){\mu}m$ for totally gap of IS group. But marginal and internal gap of two group were not differences statistically significant(p>0.05). Conclusion: Evaluation of marginal and internal gap of two group showed that no differences statistically significant and clinically acceptable results.

Assessment of dental erosion potential by the type of fermented milk (유산균 발효유 종류에 따른 치아부식 위험도 평가)

  • Kim, Kyung-Hee;Chung, Ki-Ho
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.4
    • /
    • pp.657-667
    • /
    • 2017
  • Objectives: The aim of this study was to evaluate the potential of dental erosion by three different types of commercial fermented milk on the enamel surface of bovine teeth. Methods: Forty bovine teeth (four groups of 10) were immersed in fermented milk (experimental groups: liquid type, condense-stirred type and condense-drink type) or mineral water (control group) for 1, 3, 5, 10, 15, 30, 60, 90 and 120 minutes. Enamel surface microhardness was measured before and after treatment with a microhardness tester, and Scanning Electron Microscope (SEM) was used to assess the enamel surface morphology. Results:Changes in enamel surface microhardness (before-after treatment; ${\Delta}VHN$) were significantly different among the four groups (p<0.05). ${\Delta}VHN$ was highest in the liquid type group, followed by the condense-stirred type, condense-drink type, and control groups. The ${\Delta}VHNs$ of three types of fermented milk groups were higher than that of the control group (p<0.05). The liquid type group showed higher ${\Delta}VHN$ than the other two types of condense fermented milk groups (p<0.05). However, there was no significant difference in ${\Delta}VHN$ between the two types of condense fermented milk (p>0.05). The results of SEM observation have shown the most severe surface damage in bovine teeth immersed in the liquid type of fermented milk. Conclusions: In this study, it appears that liquid type fermented milk causes greater development of dental erosion. The physical properties and pH of fermented milk types must be considered for prevention of dental erosion associated with ingestion of fermented milk.

Evaluation of different approaches for using a laser scanner in digitization of dental impressions

  • Lee, Wan-Sun;Kim, Woong-Chul;Kim, Hae-Young;Kim, Wook-Tae;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2014
  • PURPOSE. This study aimed to investigate the potential clinical application of digitized silicone rubber impressions by comparing the accuracy of zirconia 3-unit fixed partial dentures (FPDs) fabricated from 2 types of data (working model and impression) obtained from a laser scanner. MATERIALS AND METHODS. Ten working models and impressions were prepared with epoxy resin and vinyl polysiloxane, respectively. Based on the data obtained from the laser scanner (D-700; 3Shape A/S, Copenhagen, Denmark), a total of 20 zirconia frameworks were prepared using a dental CAD/CAM system (DentalDesigner; 3shape A/S, Copenhagen, Denmark / Ener-mill, Dentaim, Seoul, Korea). The silicone replicas were sectioned into four pieces to evaluate the framework fit. The replicas were imaged using a digital microscope, and the fit of the reference points (P1, P2, P3, P4, P5, P6, and P7) were measured using the program in the device. Measured discrepancies were divided into 5 categories of gaps (MG, CG, AWG, AOTG, OG). Data were analyzed with Student's t-test ($\alpha$=0.05), repeated measures ANOVA and two-way ANOVA (${\alpha}=0.05$). RESULTS. The mean gap of the zirconia framework prepared from the working models presented a narrower discrepancy than the frameworks fabricated from the impression bodies. The mean of the total gap in premolars (P=.003) and molars (P=.002) exhibited a statistical difference between two groups. CONCLUSION. The mean gap dimensions of each category showed statistically significant difference. Nonetheless, the digitized impression bodies obtained with a laser scanner were applicable to clinical settings, considering the clinically acceptable marginal fit ($120{\mu}m$).

Changes in pre-osteoblast cells associated with non-precious metal cores with dental implants: Pilot test (치과용 임플란트 적용 비귀금속 코어와 관련된 전조골세포의 변화)

  • Park, Jung-Hyun;Kang, Seen-Young;Kim, Jong-Woo;Kim, Jang-Ju;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.40 no.2
    • /
    • pp.63-69
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the non-precious metal core materials used in the dental laboratory to fabricate the implant superstructure by CAD / CAM method. And to observe and compare the morphology and distribution of the osteoblasts in relation to implant osseointegration. Methods: In this study, the mandibular right first molar tooth model was selected as an international standard to produce a single core. Using this model, the impression was made with the silicone rubber, the tooth model was scanned, and a single core was designed and 5-axis milling was performed. The materials used were Cobalt-Chromium and Nickel-Chromium, and the cores for dental implant top structures were fabricated according to the procedures of the dental labs. After the fabrication, the marginal area of the core was separated and cell culture experiment was performed. The osteoblast cells used MC3T3-E1, which is currently widely used. For morphological analysis of osteoblasts, cells were posttreated and observed using CLSM (Confocal Laser Scanning Microscope) and compared. Results: The cell adhesion behavior of the specimen surface measured by CLSM was uniformly distributed in specimen A (Cobalt-Chromium) than in specimen B (Nickel-Chromium). The distribution and changes of the cells were different in the two specimens. Conclusion : It is possible to confirm that specimen A (Cobalt-Chromium) is suitable for the living body through adhesion and proliferation of osteoblasts related to implant osseointegration in the non-precious metal superstructure used after implantation. It is considered that it is preferable to use Co-Cr when fabricating the superstructure.