• Title/Summary/Keyword: Dental magnetic attachment

Search Result 18, Processing Time 0.025 seconds

Mandibular implant-natural tooth retained overdenture using magnetic attachment with stress breaker (하악에서 완압형 자성 어태치먼트를 부착한 임플란트-자연치 피개 의치: 10년 증례보고)

  • Park, Eun-Chul;Lee, Su-Yeon;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.378-386
    • /
    • 2015
  • Overdenture has the advantage of improving the stability and retention of the denture but the abutment may be easily affected by caries or periodontal disease and the thin denture can be easily broken. The magnetic attachment overdenture has a high vertical retention but a low horizontal retention, thus, exerting a less disruptive force to the abutment or implant and shows less abrasion or damage compared to other mechanical retainers. Denture fractures in overdenture is caused by the thin denture base as the attachment is inserted, but it may also be caused by the difference in detrusion between soft tissue and hard tissue, and between an implant and a natural tooth. To compensate this shortcoming, a magnetic attachment with a silicone ball inserted in the magnet was developed as we report a successful case using this specific type of magnetic attachment overdenture.

Observation of bilaminar zone in magnetic resonance images of temporomandibular joint

  • Nah Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.31 no.4
    • /
    • pp.221-225
    • /
    • 2001
  • Purpose: To observe the relationship of bilaminar zone of temporomandibular joint retrodiscal tissues to the disc condition. Materials and Methods : The upper and lower stratum of bilaminar zone were identified on magnetic resonance open mouth images of 148 joints from 74 patients with disc displacements. Results: Both strata were identifiable in 105 joints which had disc displacement with reduction. Lower stratum was not identifiable in 35 joints which had disc displacement without reduction but 12 of 35 had hyalinized posterior attachment where the disc was. The 8 joints which had partial disc displacement without reduction showed identifiable lower stratum at the reducing site which was medial. Conclusion: Disruption or no identification of lower stratum which corresponds to the condylar portion of posterior attachment may be the sign of disc displacement without reduction.

  • PDF

A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment (자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구)

  • Seo, Min-Ji;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2008
  • The aim of this study was to compare the retention and stability of implant overdenture according to the shape and the number of magnetic attachment. The experimental groups were designed for the number of implants(1, 2, 4) and shape of magnetic attachments(flat, cushion, dome type) resulting in 9 subgroups. 45 attachments were tested attached to $Br{\aa}nemark$ system implants which were planted on a mandibular model. Each attachment was composed of the magnet assembly embedded in a overdenture sample and the abutment keeper screwed into the implants. Dislodging tensile forces were applied to the overdenture samples using an Instron(cross-head speed 50.80mm/min) in 3 directions simulating function: vertical, oblique, and anterior-posterior. The loading was repeated 10 times in each direction for 45 samples. The values of maximum dislodging force of each subgroup were processed statistically using SPSS V. 12.0 at the 0.05 level of significance. The results of this study were as follows: 1. Flat type magnetic overdenture was the most retentive when subjected to vertically directed forces and dome type was the lest retentive when subjected to obliquely directed forces(p<0.05). 2. In case of planting one implant, flat type had a higher vertically retentive force than anterior-posteriorly retentive force. In case of planting two implants, flat type and dome type had a higher vertically retentive force and in case of planting four implants, flat type and cushion type had a higher vertically retentive force than anterior-posteriorly retentive force(p<0.05). 3. The incremental number of dental implant, without regards to the three types of magnetic attachment shapes, showed higher retention of overdenture(p<0.05). From the results, if a patient need much more retention of implant overdenture, flat type magnetic overdenture would be a good treatment. In case of the bruxism where excessive lateral forces are already present, dome type could be expected to produce better results. In case of planting one implant, flat type is more stable than the other shape of magnet and in case of two implant, flat type and dome type are more stable and in case of four implants, flat type and cushion type are more stable. Planting more than two implants and using flat type magnetic attachment would provide better retention and stability of implant overdenture

THE ELECTROCHEMICAL STUDY ON CORROSION RESISTANCE OF VARIOUS DENIAL MAGNETIC ATTACHMENTS (수종 치과용 자석유지장치의 부식저항성에 대한 전기화학적 연구)

  • Sohn Byoung-Sup;Chang Ik-Tae;Heo Seong-Joo;Keak Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.336-350
    • /
    • 2001
  • The purpose of this study was to investigate corrosion tendency and to compare corrosion resistance of three dental magnetic attachments and its keeper alloy by coercive, electrochemical method. By using petentiodynamic polarization technique, magnetic elements and its keeper alloy of Magfit EX600 system(MF, MFK), Dyna ES regular system(DN, DNK) and Shiner SR magnet system(SR, SRK) were corroded electrochemically in 0.9% NaCl electrolytic solution. Open-circuit potential and anodic polarization curve was measured with Potentiostat(model 273 EG&E) and polarization curve was created by current density per square area following scanning of increased series of voltage in the rate of 1.0mV per second. Before and after electrochemical corrosion, the surface roughness test was done. Thereafter the change of mean surface roughness value(Ra) and mean peak value(Rt) of surface roughness was compared one another. In order to observe the corroded surface of each specimen, metallurgical light microscopic(${\times}37.5$) and scanning electron microscopic view(SEM ${\times}100$) was taken and compared one another. Conclusion is followings. 1. All of six covering metal of dental magnetic attachments and its keeper alloy were corroded in various degree after electrochemical corrosion. 2. The corrosion resistance of which used in this experiment is the following in high order; DNK, MFK, DN, MF, SRK and SR. 3. Especially Shiner magnet system and its keeper alloy were more severely corroded after electrochemical corrosion and the change of Ra Rt value were more increased than others. 4 Metallurgical and scanning electron microscopic view showed the pitting corrosion tendency of all experimental alloy but DNK and SR. 5. Covering metal of magnet was more corroded than its keeper alloy.

  • PDF

THE EFFECT OF PERMANENT MAGNET CONNECTING WITH DENTAL IMPLANT ON DISTRIBUTION AND ATTACHMENT OF OSTEOBLAST-LIKE CELL AROUND THE DENTAL IMPLANT (임플랜트에 연결한 영구자석이 임플랜트 주위 뼈모세포의 분포와 부착에 미치는 영향에 관한 연구)

  • Oh Na-Hee;Choi Boo-Byung;Kwon Kung-Rock;Baik Jin;Lee Sung-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.511-518
    • /
    • 2005
  • Purpose: The purpose of this study is to find the effect of rare earth magnet's magnetic field of to the osteoblast around the implant by the means of observation number, and distribution around the implant which is connected to the permanent magnet but not, counted and compared by the number of cells attached to the surface of the implant. Material and method: The permanent magnets, made in the healing cap form, were connected to the implant future, and placed on the culture plate, The osteoblast-like cell: MC3T3-E1 were used for cell culture. As the control group, the implant were connected to normal healing cap, and cultured in the same conditions. 48 hours later, using inverted microscope, the number and distribution of osteoblast around the implant were observed, and 72 hours later, the number of the cells attached to the implant were counted. Results: As a result, the implant connected to the permanent magnet had proved to have a more concentrated cell distribution rate than the control group. The implant connected to the permanent magnet, neck area : which has about 10 gauss magnetic force, had more cells than apex area. The implant connected to the permanent magnet had proven to attach to the osteoblast more productively than control group's implant. Conclusions: This research showed that the magnetic field of the permanent magnet affected the distribution and growth rate of the osteoblast around the implant. In order to support this study, it also had need to monitor the progress of the permanent magnet specifically shown on the neck area, which has10 gauss magnetic force. So after additional research on the distribution and attachment of the cells, and further more, on bone formation, it will be concluded that the clinical applications ,such as immediate loading of implant treatment are possible.

Influence of marginal bone resorption on two mini implant-retained mandibular overdenture: An in vitro study

  • Guo, Ying;Kono, Kentaro;Suzuki, Yasunori;Ohkubo, Chikahiro;Zeng, Jian-Yu;Zhang, Jing
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.55-64
    • /
    • 2021
  • PURPOSE. To investigate the biomechanical effect of marginal bone resorption (MBR) on the mandibular mini implant (MI)-retained overdenture (MI-OD) on the edentulous model. MATERIALS AND METHODS. The experimental mandibular edentulous model was modified from a commercial model with 2 mm thick artificial soft tissue under denture base. Two MIs (Φ2.6 mm × 10 mm) were bilaterally placed between the lateral incisor and the canine area and attached with magnetic attachments. Three groups were set up as follows: 1) alveolar bone around the MI without MBR (normal group), 2) with MBR to 1/2 the length of the implant (resorption group), and 3) complete denture (CD) without MI (CD group). Strain around the MI, pressure near the first molar area, and displacement of denture were simultaneously measured, loading up to 50 N under bilateral/unilateral loading. Statistical analysis was performed using independent-samples t test and one-way ANOVA (α=.05). RESULTS. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure in CD was higher than in MI-ODs (P<.05), while there was no statistical difference between the normal and resorption group (P>.05). Similarly, the CD demonstrated a greater displacement of the denture base than did the MI-ODs during bilateral and unilateral loadings (P<.05). CONCLUSION. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure on posterior alveolar ridge and denture displacement of MI-ODs significantly decreased compared to CDs, even when MBR occurs. Bilateral balanced occlusion was recommended for MI-ODs, especially when MBR occurred.

Oral rehabilitation with magnetic overdentures for an old patient with complex systemic diseases (복합적인 전신질환이 있는 안면마비 환자의 양악 자성 피개의치 수복 증례)

  • Ko, Eunjin;Ahn, Sujin;Lee, Sukwon;Park, Sujung;Lee, Richard Sungbok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.150-156
    • /
    • 2015
  • As dental implant treatment becomes popular for both partial and complete edentulous patients, old people with complex systemic diseases also tend to prefer implant-assisted-overdenture or implant-supported-fixed prostheses to conventional complete denture. In this case, 77-year-old female who was on medication for hypertension and osteoporosis and paralyzed on right side due to stroke visited for implant-assisted-overdenture on lower jaw. After oral and radiographic examination, root-assisted magnet overdenture on upper jaw and implant-assisted magnet overdenture on lower jaw are planned. Consequently, overdentures using self-adjusting magnetic attachment(SA) system on both jaws resulted in recovering satisfying function and retention, which is enable to insert and remove with only one hand.

Overdenture with magnetic attachments for a patient with Parkinson's disease: a case report (파킨슨병 환자의 자성 피개의치 수복 증례)

  • Ma, Bo-Young;Min, Byung-Kwee;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Chan;Shin, Jin-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.301-306
    • /
    • 2016
  • It is very hard for edentulous patients to satisfy retention and stability with their complete denture. Especially, for patients with systemic diseases such as Parkinson's disease causing involuntary and limited movements, fabricating complete dentures may be challenging to both dentists and patients due to functional limitations. To overcome this problem, overdentures can be used through conserving retained roots. In this case, a 45-year-old male patient had to extract numerous teeth due to dental caries, and at the time of visit he was taking drugs for diabetes and Parkinson's disease for a period of long time. A complete denture was applied to maxilla, and for mandible, an overdenture on two preserved retained roots was applied where its retention and stability were obtained by magnetic attachments. This case reports that overdenture with retained roots improved overall functional limitations.