• Title/Summary/Keyword: Dental laboratory industry

Search Result 27, Processing Time 0.024 seconds

Study on the effect of clinical practice satisfaction and major satisfaction on employment intention of students in the department of dental technology who experienced clinical practice (임상실습을 경험한 치기공(학)과 학생들의 임상실습 만족도, 전공 만족도가 취업 의향에 미치는 영향에 관한 연구)

  • Hyeeun Jeong;Hyunsic Lee
    • Journal of Technologic Dentistry
    • /
    • v.45 no.4
    • /
    • pp.95-101
    • /
    • 2023
  • Purpose: This study examines the clinical practice satisfaction and major satisfaction of dental technology students who have experienced clinical practice to identify whether there is an effect on employment intention of satisfaction level as a basis for increasing the employment rate of dental technicians. Methods: A survey was distributed among 150 dental technology students, and the data were analyzed using descriptive statistics and frequency and correlation analyses. Finally, multiple regression analysis was used to verify the research hypotheses. All statistical analyses were carried out using IBM SPSS Statistics ver. 27.0 (IBM). Results: The students exhibited high levels of satisfaction with their clinical practice (4.20) and dental technology major (4.07). Further analysis showed a positive correlation between intention to work in dental laboratories and satisfaction with a dental technology major (practice; r=0.437, p<0.05); clinical practice organization (r=0.682, p<0.05); and satisfaction with the clinical practice institution (r=0.650, p<0.05). Statistically significant positive associations (p<0.05) were also observed between clinical practice form and environment, satisfaction with dental technology major, and school region (i.e., metropolitan area). Conclusion: The findings of this study suggest that high levels of satisfaction with clinical practice and dental technology major can contribute to increased employment rates among dental technicians by promoting their intention to work in the related industry.

A Study on the educational direction of Dental Technology Department in the 21st century (21C 치과 기공과 교육의 방향에 대한 연구)

  • Park, J.H.
    • Journal of Technologic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.153-163
    • /
    • 1999
  • The 21st centurt, the era of change-space, is requesting us to readjust our education system. In other words, we should renew it by looking back into the past cultivate more advanced ideas. As a matter of fact junior colleges have been considered just as miniture of universities in every way such as curriculum, prossor emploment, school affairs, etc. Therefore we should change our existing education system not to be criticized for the next century. May students are trained for industry as dental technicians in our department of college. We should educate experiment and practice substantially as college professors as well as exert ourselves in developing our abilities to adapt to high diverse industrial technique, putting emphasis on practice more than theory. It is mecessary for us to sufficiently teach the technique to good students and make them display their abilities in order to produce high quality goods. Reinvestment ineducation is a condition precedent. Dental laboratories have just employed the students that graduated from our college. However it's time for a change. They should pay attention to our education and assist us in all respects with the thought of equally educating professional dental technicians together with us. The field practice system is subject to reinforcement so that our students have more opporunities of utilizing the tools and materials for practice. Finally we should not only carry out new reserch more deeply no less than dental technicians who are experienced in business for development of education system but endeavor to meet pratical education by adding what is pratically needed in dental laboratories to the existing education system.

  • PDF

Evaluation of Flexural Strength of 3D Printing Resin According to Post-Curing Equipment and Time (후경화기와 경화시간에 따른 3D 프린팅 레진의 굴곡강도 평가)

  • Hae-Bom Kim;Jae-Won Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.629-637
    • /
    • 2023
  • This study aimed to evaluate the effect of post-curing equipment and time on the flexural strength of 3D printing resins produced by a liquid crystal display(LCD) printer. The three 3D printing resins(DENTCA Denture Teeth, DT; C&B 5.0 hybrid, CH; C&B Permanent A2, CP) were divided into four groups according to post-curing time(10 min and 30 min) and equipment with or without vacuum treatment. For the three-point flexural strength test and biaxial strength test were prepared by method according to ISO 10477, ISO 6872, respectively. Flexural strength was measured with universal testing machine. Comparison between post-curing time of each post-curing equipment was analyzed by independent sample t-test and Mann-Whitney U test(α=.05), and comparison between groups according to each 3D printing resin was performed by Kruskal-Wallis test and post-hoc by Bonferroni-Dunn test(α=.05). The flexural strength of the resin post-curing under vacuum was higher than that of the resin post-curing in air. In the comparison according to the post-curing time, in the case of the post-curing equipment without vacuum, the 30 minute curing time showed significantly higher flexural strength than the 10 minute curing time, except for the biaxial flexural strength of CH(P<.05). In the post-curing equipment with vacuum, the three-point flexural strength of all 3D printing resins(DT, CH, and CP) showed a higher value at 30 minute curing time than at 10 minute curing time.

Effect of Washing Solvent and Washing Method on Flexural Strength of 3D-Printed Temporary Resin Material (세척 용액 및 세척 방법이 3D 프린팅 임시수복용 레진의 굴곡강도에 미치는 영향)

  • Hae-Bom Kim;Jae-Won Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.2_2
    • /
    • pp.389-395
    • /
    • 2024
  • The purpose of this study was to evaluate the effect of different washing solvents and washing methods on the flexural strength of 3D printed temporary resin. A bar(25 × 2 × 2 mm) was produced with a layer thickness of 50 ㎛ using an LCD-type 3D printer and divided into 15 groups(n = 10, each) according to washing solution(IPA; 99% isopropyl alcohol, TPM; 93% Tripropylene glycol monomethylether, ETL; Ethanol, TWC; Twin 3D Cleaner, and DNC; DIO navi Cleaner) and washing method(Dip; Dip washing, Ultra; Ultrasonic washing, and Auto; Automated washing). All groups were washed for 5 minutes, and post-cured for 5 minutes using a UV LED light curing machine. The Flexural strength was measured using a three-point bending test using a universal testing machine. For statistical analysis, one-way ANOVA, Tukey HSD post hoc test, Kruskal-Wallis test and post-hoc by Bonferroni-Dunn test(𝛼=.05) were performed depending on whether the normality test was satisfied. In all washing solvents except TPM and DNC, the Dip group showed the lowest flexural strength values, while the Auto group showed the highest flexural strength values except for DNC. Additionally, the washing solution showed completely different flexural strength values depending on the washing method.

Research for The Comparing Test of the Fracture Strength According to the Heat Curing Method in the Denture Base Resin (의치상용 열중합 레진의 Curing방법에 따른 파절 강도의 비교실험연구)

  • Han, Min-Soo
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.95-103
    • /
    • 2002
  • For this study, self curing resin and heat curing resin used for existing usual resin denture base in the denture industry were chosen by manufacturer. Curing tests for 30-minute, I-hour, 2-hour and 3-hour were conducted to know the strength of the resins and conduct analysis to get other necessary information. The results obtained are as follows: 1. Heat curing resins show a little differences among the manufacturers. However 30-minute curing resin shows great difference as shown in the fracture strength test. 2. The effect from the granularity of the resins on the fracture strength was found insignificant which means there is no difference between coherence and strength. 3. To summarize the results from each time level, the longer the time is, the more the minute cracks on the surface, which is the cause of reduced strength. From this test, it was identified that in making the denture base for patients in dental clinics, 30-minute curing is most efficient and effective in reducing discoloration and monomers, although long-time curing has been considered to be the principal.

  • PDF

Study on Acknowledge and State of Clinical Experience for 3-years Dental Technology Department (3년제 치기공과 임상실습에 대한 인식 및 실태조사 - 일부 치과기공소 소장을 중심으로 -)

  • Park, Myung-Ja
    • Journal of Technologic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.41-57
    • /
    • 1995
  • This study was conducted to collect and analyze previous information in order to manage efficience, improve experience effect and promote employment rate. The questionnaire interview with 27 chief of dental Laboratory refered clinical experience in technology department about clinical experience in 14 Jumior colleges were also investigated. The results were summarried as follows : The portion of age of 35-39 among chief of dental Laboratory was 40.7% which was the highest, that of male was 96.3%, that of junior college graduate was 97.5%, that of 10years experience was 92.6% and that of ceramic technician was 85.2%, 63.0% dental laboratory for clinical experience was a bore space of 30pyong. Aspect of dental laboratory management, manufacturing all part of prosthetic restoration was 29.6%, othodontic appliance and ceramic restoration was 7.4%, 3.8%, each. The percentage of 40.7 was having connection with 30-3a dental clinics and referring case per day was 10-19 cases(40.7%), manufacturing time of referred prosthetic restoration was 3-4 days(77.8%), places preparing seminar room for education was 29.6%, above a place of 40pyong was 11.1% 30-34 pyong and 35-39 pyong was 7.4% each. During training of 2 years education course student, 18.5% was rack of thorough occupational career. While 44.4% will want the more salary among 3years education course student, 74.1% will expect the more dental techmicians would engaged in their field, 51.9% will hope improve of their theory and practice, 29.6% be expected better skill and 14.8% be expected better theory. Attitude of clinical experience places was distributed by 59.3% of offering only experience chance, 25.9% of wasting time and 29.0% of annoying. The big emphasis of climical experience was thorough occupational career(44.4%). The clinical experience places of our college were selected after direct visiting, so their condition of management was not that bad but most of dental laboratory were poor in management state and working environment. Therefore it is difficult to choose appropriate places and dental Laboratory are also limited manpower and time as suppliers. So that it recommended to induce flexible management of experience period by interval and rotation of experience places among college and to applicate intern-system for employment ant industry-college cooperation aspect.

  • PDF

Comparison of Shear Bond Strength of Veneer Ceramics to Co-Cr Alloys Produced by Selective Laser Melting and Casting Technique (선택적 레이저 용융 그리고 전통적인 주조 기술에 의해 제조된 Co-Cr 합금에 대한 전장용 세라믹의 전단 결합 강도 비교)

  • Hong, Min-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.434-439
    • /
    • 2020
  • Selective laser melting (SLM) manufactures an alloy using laser as a heat source, and has recently been introduced in the dental industry. However, there is a lack of analytical research on metal-ceramic restorations achieved by SLM. This study evaluates and compares the metal-ceramic bond strength of Co-Cr alloys produced by selective laser melting and casting methods. Co-Cr samples required for this study were produced through the sintering process of ceramics, by applying the SLM and CAST methods. The metal-ceramic bond strength was measured by applying the shear bond strength test. In order to determine the area fraction of adherent ceramic, Si content of the specimen was measured using scanning electron microscopy SEM/ EDS. Results of the metal-ceramic bond strength and AFAC were analyzed by t-test (α = 0.05). No significant difference was observed comparing the bond strength of SLM and CAST Co-Cr alloys (P> 0.05). However, the SLM group had much better ceramic adherence than the CAST group (P < 0.001). Moreover, oxidation characteristics were similar for both SLM and CAST Co-Cr alloys, but metal structures were different. These results imply that although the bond of ceramic and Co-Cr alloy is not related to the manufacturing method, SLM alloys impart better ceramic adherence. This indicates that alloys made with SLM can be used to fabricate upper implant prostheses in the future. In particular, it is expected to overcome the shortcomings of the CAST method, and save time and cost.

Identification of Enterococcus faecalis on MSB Medium Selective for Mutans Streptococci

  • Lee, Seung-Hoon;Yoo, So-Young;Kim, Hwa-Sook;Kang, Sook-Jin;Lim, Sung-Hoon;Kim, Kwang-Won;Park, Jung-Min;Shin, Yong-Kook;Shin, Jeong-Hwan;Baek, Dong-Heon;Choe, Son-Jin;Kook, Joong-Ki
    • International Journal of Oral Biology
    • /
    • v.31 no.1
    • /
    • pp.7-10
    • /
    • 2006
  • Mitis-salivarius sucrose bacitracin(MSB) medium is widely used in the selective isolation of mutans streptococci(MS), a designation for a group of oral cariogenic species. Recently, we have isolated three bacterial strains grown on MSB agar from human dental plaques. The three strains exhibited biochemical characteristics similar to those of the biotype IV of MS, with the exception that they manifested a positive reaction for arginine deaminase. The objective of this study was to identify and characterize these three clinical isolates. The bacteria were identified with biochemical tests as well as by 16S rDNA cloning and sequencing. In order to compare the antibiotics susceptibility of the clinical isolates with that of type strain, the minimum inhibitory concentrations of 9 antibiotics were determined using broth dilution assays. The results identified all of our three clinical isolates as Enterococcus faecalis. All E. faecalis strains were found to be susceptible to penicillin G, amoxicillin, augmentin, and vancomycin, but were resistant to ciprofloxacin, cefuroxim axetil, and clindamycin. Our findings indicate that E. faecalis is capable of growing on MSB agar, and suggest that the MSB medium be improved so that only MS should be recoverable on the medium, as originally devised for their selection.

Evaluation of Marginal and Internal Gap of Temporary Prosthesis Fabricated by 3D Printing Method According to Rinsing Method and Rinsing Time (세척 방법 및 세척 시간에 따른 3D 프린팅 방식으로 제작된 임시 보철물의 변연 및 내면 적합도 평가)

  • Ji-Hyeon Bae;Jae-Won Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.561-570
    • /
    • 2023
  • This study was to evaluate the effect of different rinsing times and methods on the accuracy of temporary prostheses fabricated by 3D printing method. Sixty temporary prostheses were fabricated with LCD types of 3D printer(Halot-Sky, Creality, Shenzhen, China) and divided into six groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5 and 10 min using three methods-hand washed, ultrasonic cleaning, and automated washing. All specimens were polymerized for 3 minutes under the same conditions. The marginal and internal gaps of specimens were examined using a replica technique. The light-body silicone thickness was measured at 6 reference points(Absolute marginal discrepancy, Marginal, Chamfer, Axial, Angle, and Occlusal gap). All measurements were performed by a stereomicroscope. Reference point images were taken at 100× magnification and then measured using an image analysis program. Statistical analysis was performed using Two-way ANOVA, One-way ANOVA, and the Kruskal-Wallis test (p = .05). The marginal and internal gaps were statistically different according to the rinsing methods and rinsing times(p < .001). In the rinsing time, the temporary prosthesis rinsed for 5 minutes group showed higher accuracy than 10 minutes group. In the rinsing method, the hand washing group showed higher accuracy than the automated washing group.

Evaluation of Fracture Strength and Screw Loosening of a New Angled Abutment with Angulated Screw Channel (나사 접근 구멍 각도가 조절 가능한 새로운 경사형 지대주의 파절강도 및 나사 풀림력 연구)

  • Jae-Won Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.623-628
    • /
    • 2023
  • The purpose of this study was to evaluate the fracture strength and removal torque value (RTV) of a conventional angled abutment and a newly developed angled abutment (Beauty up abutment) with an angulated screw access hole. Each abutment was divided into a control group and an experimental group (n = 20, respectively). To measure the fracture strength, the abutment was connected to the internal hex implant with 30 Ncm torque, and a load was applied at 30 degree angle with cross-head speed of 1 mm/min using a universal testing machine according to the ISO 14801:2016 standard. To measure RTV, each abutment was fastened to the implant with 30 Ncm torque. Retightening was performed after 10 minutes, and initial RTV was measured with a digital torque gauge. After retightening, a load of 250 N was applied to the abutment at a 30 degree angle using a chewing simulator. After a total of 100,000 repeated loads, RTV was measured. Statistical analysis was performed using Wilcoxon signed rank test and Mann-Whitney U test (α = .05). The fracture strength of the experimental group was statistically significantly lower than that of the control group (P = .009). There was no significant difference between initial RTV and post-loading RTV between the experimental group and the control group (P = .753, P = .527, respectively), and cyclic loading did not significantly affect RTV in both groups (P = .078).