• Title/Summary/Keyword: Dental laboratory

Search Result 1,231, Processing Time 0.021 seconds

An Experimental study on The Porcelain Shade Stability after Repeated Firing (도재의 반복성이 Shade에 미치는 영향)

  • Kim, Uoong-Chul;Lee, Boung-Kee
    • Journal of Technologic Dentistry
    • /
    • v.4 no.1
    • /
    • pp.5-7
    • /
    • 1982
  • This study was performed to examine the effect of repeated firing on porcelain color stability. Sixty sepcimens of generally uniform size and shape(9.7 12mm)were prepared using the manufactorer's specifications and among them 50 specimens that showed no defect after firing procedure were selected. All samples, abraded with sandpaper disc, ultrasonically cleaned, and air fired to amedium glaze were devided into 10 groups according to the number of repeated firing and, upon completion, mounted on a 13 by 16cm board. 30 persons(five dentists, ten dental techanicians, and fiftheen students) were asked to compare the samples for variations, in hue, chroma and value under natural and artificial light. The results were as follows:(1) There were no color change detected in the first four firings.(2) Slight color change were noticed in subsequent firings(ie: greater decreases in value with slight increases In chroam)(3) However, the hue remained constant in all 10 groups after repeated firings.

  • PDF

On Composition and HB of Dental Alloys (치과용합금(齒科用合金)type에 따른 조성(組成) 및 경도(硬度)에 관(關)한 연구(硏究))

  • Hyun, Joung-Gu;Lee, Byoung-Ki
    • Journal of Technologic Dentistry
    • /
    • v.7 no.1
    • /
    • pp.13-18
    • /
    • 1985
  • Casting alloys, both precious and non-precious, were by heat in order to observe the change in HB and the results were : 1. The hard treatment showed 1.4 - 1.5 times as high as the soft treatment in HB. 2. The experiment shows that Au-Pt should be contained more than 75% to prevent color change. 3. Cu by hard teatment played the greatect part in creasing the solidity of Ag-Cu alloy. 4. Casting Co-Cr alloys showed little difference of HB in heat treatment.

  • PDF

Prosthetic restorations with cementless screw-retained implant systems: a case report (시멘트리스 나사 유지형 임플란트 시스템을 이용한 보철물 수복 증례)

  • Young-hae Jung;Im-Sun Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.4
    • /
    • pp.124-130
    • /
    • 2023
  • This study aims to describe the clinical experience of single and bridge crowns fabricated using a cementless screw-retained implant prosthesis system. In the case of single crown (#37), regular link (HDL) was used, and bridge crowns (#15~#24), (#26~#27), (#17~#14) (#24~#26) were fabricated by selecting regular link and short link considering the vertical height. One abutment was hex shaped to ensure that it could be mounted while preventing insertion and prosthesis rotation. The advantages of cementless implant prosthesis include shorter chair time and periodic care, strong retention with LINK abutment, safety from inflammation, bacterial infection, and complications due to peri-implant cement, and high patient satisfaction. Dentists should double-check the position of the implant fixture and dental technicians should continuously manage the fit of the link and prosthesis with digital equipment to reduce screw loosening and fractures.

Retirement attitude of korean dental technicians (한국 치과기공사의 은퇴태도)

  • Lee, Sun-Kyoung;Hwang, Kyung-Sook;Hwang, Seong-Sig;Park, Yong-Duk;Seong, Jeong-Min
    • Journal of Technologic Dentistry
    • /
    • v.37 no.4
    • /
    • pp.253-259
    • /
    • 2015
  • Purpose: The purpose of the study is to investigate the need for the retirement attitude of korean dental technicians. Retirement attitude is important in the study of retirement planning. Methods: A total of 778 dental technicians were selected by proportional stratified by region compared to extraction sampling from a list of korea dental technician association in 2012. The final sample size was 386. Questionnaires consisted of 10 questions general characteristics, 9 questions for the current life satisfaction and retirement preparation, and 4 questions about retirement attitudes on a Likert 5 scale. Cronbach's alpha was 0.812 in the study. All statistical analyzed were performed using SPSS 14.0(Statistical Packages for Social Science Ver. 14.0. Chicago, IL, USA). Results: An average of $3.01{\pm}0.8$ dental technicians were retirement attitude. To affect retirement attitude marital status, age, subjective health status, assets satisfaction, job type, job satisfaction and the economic outlook was living after retirement (p <0.05). Conclusion: This study suggested that retirement attitude of korean dental technicians was very important and the preparation must be connected with the social welfare policy.

Effects on Bond Strength between Zirconia and Porcelain according to Etching Treatment and Low Temperature Degradation (지르코니아 표면에칭처리와 저온열화현상이 지르코니아와 전장도재의 결합강도에 미치는 영향)

  • Park, Jin-Young;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Ji-Hwan;Kim, Hae-Young
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.140-149
    • /
    • 2014
  • The purpose of this study was to investigate the influence of etching surface treatment and aging treatment of zirconia on the shear bond strength between zirconia core and veneered ceramic. Four groups of zirconia-ceramic specimens were prepared; 1) NEZ group (no etching zirconia), 2) EZ group (etching zirconia), 3) ANEZ group (aging and no etching zirconia), 4) AEZ group (aging and etching zirconia). The shear bond strength between zirconia and porcelain was measured using Instron Universal Testing Machine. Surface texture with crystalline structure of zirconia surface was examined by the field emission scanning electron microscopy (FE-SEM) with ingredient analysis. The fractured surfaces of specimens were examined to determine the failure pattern by a digital microscope. The mean${\pm}$standard deviation of shear bond strengths were $23.47{\pm}3.47$ Mpa in NEZ, $28.30{\pm}4.34$ Mpa in EZ, $21.85{\pm}4.65$ Mpa in ANEZ, $24.65{\pm}3.65$ Mpa in AEZ group, respectively, and were significantly different (p<0.05). The average shear bond strength was largest in EZ group, followed by AEZ, NEZ, and ANEZ groups. Most specimens in NEZ group showed adhesive failure and most specimens in EZ, AEZ, and ANEZ group showed mixed failure. Surface of etching treatment group (EZ and AEZ) showed complex micro-structure and irregular surface texture which may facilitate mechanical interlocking, while untreated zirconia surface presented simpler micro-structure. In conclusion, an etching treatment improved bonding strength between zirconia and porcelain by forming mechanical interlocking.

Bacterial Contamination of Dental Unit Water Systems in a Student Clinical Simulation Laboratory of College of Dentistry (치과대학 임상 시뮬레이션 실습실 치과용 유니트 수계의 세균 오염도 조사)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.15 no.2
    • /
    • pp.232-237
    • /
    • 2015
  • The water supplied from dental unit water systems (DUWS) in dentistry may be heavily contaminated with bacteria and thus may be a potential source of infection for both practice staff and patients. The aim of this study was to evaluate the level of heterotrophic bacteria and to confirm the presence of opportunistic pathogens from DUWS in student clinical simulation laboratory of college of dentistry. Water samples were collected from 36 ultrasonic scalers in student clinical simulation laboratory. The levels of heterotrophic bacteria in water samples were quantified by counting colony forming units (CFUs) on R2A agar media. In addition, opportunistic pathogens were detected by using the polymerase chain reaction (PCR) method. The mean CFUs were 16,095 CFU/ml for water samples and all of water samples exceeded current American Dental Association recommendations of 200 CFU/ml. Pseudomonas species and non-tuberculous Mycobacterium species were detected in the one sample and two samples, respectively, among the 36 water samples by the PCR with specific primers for these bacteria. Our study indicated that DUWS in student clinical simulation laboratory can cause potential infection in students and participants. This study suggested the dental unit water line management and wearing personal protective equipment in student clinical simulation laboratory will be needed to reduce bacterial contamination.

Precision evaluation of crown prosthesis manufactured by two bur and three bur (2종류의 버와 3종류의 버를 이용해 제작된 크라운 보철물의 정밀도 평가)

  • Kim, Chong-Myeong;Jeon, Jin-Hun;Lee, Jae-jun;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.38 no.2
    • /
    • pp.57-62
    • /
    • 2016
  • Purpose: The purpose of this study was to assess precision of crown prostheses that were fabricated by using 2 kinds of bur or 3 kinds of bur. Methods: The crowns were fabricated by using the first molar of the right maxillary in this study. The abutments that were prepared were scanned by using a scanner and designed by using CAD software. Based on the crown design, NC data were created with CAM software. The created NC data were used while fabricating the crown prostheses by using 5-axis milling machine. Scanning was done for the internal and external surface of the completed crown prostheses and 3-dimensional measurement was conducted for precision assessment. Results: The $RMS{\pm}SD$ value for the external surface of the crown prostheses that was fabricated by using two burs and three burs were $28.5{\pm}4.1{\mu}m$ and $19.1{\pm}2.8{\mu}m$, respectively; and the value for two burs were bigger than that for three burs with statistical significance (p<0.001). The $RMS{\pm}SD$ value for the internal surface of the crown prostheses that was fabricated by using two burs and three burs were $14.9{\pm}1.9{\mu}m$ and $13.3{\pm}2.5{\mu}m$, respectively; and the value for two burs were bigger than that for three burs but with no statistical significance. Conclusion: Based on this study, the prostheses that were fabricated by using 3 bur presented better stability compared to those that were fabricated by using 2 bur and statistically significant difference was found only in the external surface.

Assessment of the fit of partial frame fabricated by SLS 3D printer (국부상의치의 전해연마에 따른 SLS 3D 프린터의 적합성 평가)

  • Park, Young-Dae;Kang, Wol
    • Journal of Korean society of Dental Hygiene
    • /
    • v.19 no.6
    • /
    • pp.1067-1075
    • /
    • 2019
  • Objectives: The present study aimed to compare the accuracy of removable partial denture (RPD) frameworks fabricated by selective laser sintering (SLS) before and after electropolishing. Methods: A partially edentulous mandibular model was used as the working model. Scanning of the model was performed using a dental scanner. The framework was designed using CAD software. The metal framework was formed using an SLS 3D printer. 3D scans of the two fabricated prototypes produced before and after electropolishing were overlapped with reference data. The fit was calculated based on Root Mean Square (RMS). Fabrication accuracy was verified using the paired t-test to compare the discrepancy before and after electropolishing. Results: The mean (SD) values of RMS before and after electropolishing were 126.6 (34.19) and 75.86 (21.36), respectively. There was a statistically significant difference before and after electropolishing (p<0.05). Conclusions: Metal frameworks made with SLS 3D printers showed clinically acceptable fit after electropolishing.

Comparative Study in Fracture Strength of Zirconia Veneering Ceramics (지르코니아 전장 세라믹의 파절강도에 관한 비교 연구)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of dental hygiene science
    • /
    • v.10 no.5
    • /
    • pp.335-340
    • /
    • 2010
  • This study was performed to evaluate the fracture strength of the dental zirconia veneering ceramics for zirconia ceramic core. Six commercial zirconia veneering ceramics were used in this study, namely E-Max(Ivoclar vivadent, Inc, Liechtenstein), Creation ZI(KLEMA Dental produckte GmbH, Austria), Cercon ceram kiss(Degudent, GmbH, Hanau-Wolfgang, Germany), Triceram(Dentaurum, Ispringen, Germany), Zirkonzahn(Zirkonzahn GmbH, Italy), Zirmax(Alpadent, korea). All samples were prepared according to the relevant instructions of manufacture. Disc specimens were prepared to the final dimensions of 17 mm in diameter and 1.5 mm in thickness. The biaxial flexure strength test was conducted using a ball-on-three-ball method. All specimens were tested in a moisture-free environment. Average flexural strengths were analyzed with Weibull analysis and one-way analysis of variance(ANOVA). Significant differences were founded between the mean flexural strength values of five commercials zirconia veneering ceramics and the other. The flexural strengths and Weibull modulus were similar to those of five groups E-Max(EM), Creation ZI(CR), Cercon ceram kiss(CE), Triceram(TR), Zirkonzahn(ZI) with the exception of Zirmax(ZM). The biaxial flexural strength from Cercon ceram kiss(CE) was higher than those of other groups. Fracture analysis showed similar results for these five groups.

Accuracy of implant custom abutments according to different radius of curvature value (곡률 반경 값에 따른 임플란트 맞춤형 지대주의 정확도)

  • Wol Kang;Hyuk-Joon Lee
    • Journal of Technologic Dentistry
    • /
    • v.46 no.3
    • /
    • pp.61-66
    • /
    • 2024
  • Purpose: This study aimed to assess the accuracy of implant custom abutments according to the different radii of the curvature value. Methods: Two custom abutments with different radii of the curvature value were designed based on dental computer-aided design. Then, a total of 20 customized abutments, 10 of each design, were milled according to the designs. The fabricated custom abutments were scanned using a model scanner. Using Geomagic Control X (3D Systems) scanned files were superimposed on the designed files to evaluate trueness, and scanned files for each group were superimposed on each other to evaluate precision. Results: The trueness values of radius of curvature value (CV)-0.75 and CV-1.50 were 56.26±5.66 ㎛ and 47.10±2.64 ㎛, respectively. A significant difference (p<0.001) was found between the groups. The precision values of CV-0.75 and CV-1.50 were 26.87±1.24 ㎛ and 26.08±1.03 ㎛, respectively. No significant difference was found between the groups. Conclusion: The radius of the curvature value in the custom abutment design affected the machining accuracy.