• Title/Summary/Keyword: Dental laboratory

Search Result 1,216, Processing Time 0.024 seconds

Oral health and self-management recognition of patients with dentures and subjective work ability effect of denture satisfaction (의치 환자의 구강상태와 자가관리 인식 및 주관적 저작능력이 의치 만족도에 미치는 영향)

  • Lee, Sook-Jeong;Jeong, In-Ho;Kim, Byung-Sik;Park, Young-Dae;Lee, Dong-Geon;Park, Ji-Young;Hwang, Hye-Kyung;Lee, Jong-Hwa
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.367-376
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate self management and subjective chewing ability and provide the basic information to research of healthy life of old people from development of education and method for dental health of denture patient. Methods: From 15th or August to 15th of September in Daegu and Gyeong-buk, denture patients were targeted for a survey. Data from 295 people were analyzed. Results: Adjusted $R^2$ of oral health and denture satisfaction of an object of study increased to 24.9%(F=20.460, p<.001). Adjusted $R^2$ of denture custody and method of sterilization was 37.8% and Adjusted $R^2$ of recognition denture satisfaction of chewing effect was 14.4% which affect to most(F=9.274, p<.001). Conclusion: In conclusion denture condition, denture custody, method of sterilization, chewing effect influence oral health, healthy life of patients who have denture.

The cognition of denture fabrication activities and the costs in National Health Insurance for elderly denture (노인틀니 국민건강보험의 틀니제작행위 및 비용에 관한 인식)

  • Yu, Chin-Ho;Nam, Sang-Yong;Kim, Ji-Hwan;Nam, Kwan-Woo;Lee, Sun-Kyoung
    • Journal of Technologic Dentistry
    • /
    • v.38 no.4
    • /
    • pp.327-342
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the cognition of denture fabrication activities and its cost in National Health Insurance for elderly denture. Methods: A self-administered questionnaire was completed by 41 dental laboratories' owner who was research subjects of HIRA(Health Insurance Review & Assessment Service)'s policy research for elderly denture in 2011. The questionnaire consisted of general characteristics of the subjects, dental technicians' knowledge of national health insurance coverage of elderly denture, job-related changes after national health insurance coverage of elderly denture including validity of denture fabrication activity classification and the cost for each service. Each question was measured by Likert 5 point scale or frequency. The collected data were analyzed by SPSS 16.0. Results: Most of the research subjects had been fabricating national health insurance coverage denture(92.7%), also had ample knowledge of national health insurance coverage denture for elderly. Job-related changes after national health insurance coverage of elderly denture revealed marginal differences in the quality. The validity of fabrication activity classification of resin based complete denture was $3.71{\pm}1.023$ by Likert 5 point scale. Conclusion: The goal of national health insurance for elderly denture is to promote elderly's health and well-being. To fabricate denture is a very important part of the denture treatment. For this reason, denture fabrication activity classification and the cost analysis plan should be duly reflected in the policy of national health insurance for elderly denture.

Comparison of Mechanical Properties of Zirconia Copping by multi-layered zirconia blocks and Design locations (다층 지르코니아 블록 종류와 설계위치에 따른 지르코니아 코핑의 기계적 특성 비교)

  • Kang, Jae-Min;Kim, Won-Young;Chung, In-Sung;Jeon, Byung-Wook
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.167-175
    • /
    • 2019
  • Purpose: This study was investigated the effect of multi-layer zirconia block type and design location on the mechanical properties of zirconia copings. Methods: Three kinds of multi-layered zirconia blocks (Snow princess multi layered block, Multi cherry, Dental zirconia pre-shaded blank) were used to identify the effects of the kinds of multi-layered zirconia blocks, design locations on mechanical characteristics of zirconia copings. 150 Zirconia copings were fabricated and fracture strength, hardness and microstructure were compared and evaluated. Results: Dental zirconia pre-shaded blank(2,256.9N) had the highest fracture strength of zirconia copings on all the design locations, and it was followed by Snow princess multi layered block(2,107.5N) and Multi cherry(917.0N). Snow princess multi layered block(1,949.7Hv) had the highest hardness of zirconia copings on all the design locations, and it was followed by Dental zirconia pre-shaded blank(1,671.7Hv) and Multi cherry(1,383.7Hv). The cervical layer had the highest fracture strength and hardness of zirconia copings in all the blocks, and it was followed by the cervical+gradation layer, the enamel layer, the enamel+gradation layer, and the gradation layer. Conclusion: It was found that the fracture strength and hardness were different according to the kinds of multilayer zirconia block and design location, and it was confirmed that it is lower than the fracture strength of white zirconia.

Accuracy evaluation of dental model scanner according to occlusal attrition type (교합면의 교모형태에 따른 치과용 모형 스캐너의 정확도 평가)

  • Kim, Dong-Yeon;Kim, Ji-Hwan;Lee, Beom-Il;Lee, Ju-Hee;Kim, Won-Soo;Park, Jin-Young
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.313-320
    • /
    • 2020
  • Purpose: The purpose of this study is to compare and analyze the accuracy of single crowns based on the type of occlusal surface. Methods: A single crown wax pattern was fabricated in three types of occlusal surface. The prepared wax pattern was replicated with silicone, and stone was injected to create a stone model. The prepared specimens were scanned using a model scanner. Scans were classified into three groups, and each scan was performed six times to analyze the trueness and precision of a single crown. In addition, only the occlusal surface area was analyzed for trueness and precision. Data were analyzed using the Kruskal-Wallis H test, a nonparametric test (α=0.05). Results: With regard to the trueness value of the occlusal scan area, the no occlusal tooth attrition (NA) group showed the largest error of 3.5 ㎛, and the complete occlusal tooth attrition (CA) group showed the lowest value of 3.1 ㎛. The NA group had the greatest precision, and the medium occlusal tooth attrition (MA) group and CA group showed a low precision value of 3.2 ㎛; the difference between the groups was statistically significant (α=0.05). In the color difference map, the CA group showed a lower error than the NA group. Conclusion: The occlusal surface with severe attrition had excellent accuracy, but the accuracy of the group without attrition was low. There were significant differences between groups, but clinically acceptable values were shown.

Influence of mechanical properties of ultra-dental stone on setting methods (경화방법이 치과용 경석고의 기계적 특성에 미치는 영향)

  • Im, Yong-Woon;Hwang, Seong-Sig;Kim, Sa-Hak;Choi, Je-Woo;Jeong, Su-ha;Kim, Si-Chul
    • Journal of Technologic Dentistry
    • /
    • v.40 no.1
    • /
    • pp.33-40
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the influence of mechanical properties of various ultra-dental stone by setting methods. Methods: 240 cylinder specimens($10mm{\times}20mm$) were prepared from three ultra-dental stones(Gemma, Die keen and Fuji rock; n = 80) in accordance with the manufacturers' recommendations. Half of the specimens of each stone(n = 40) were dried in open air within a room temperature; the other half(n = 40) underwent in a silicone rubber mold in open air for 30 minutes and then were dried in a microwave oven for 10 minutes to 600W. Compressive strength(CS), compressive modulus(CM) and diametral tensile strength(DTS) conducted until fracture using Instron 5966 at each of the following periods: 1 and 24 hours from mixing. One-way analysis of variance and Scheffe's post hoc test were performed for statistical comparisons at a significance level of P<.05. Results: The CS and CM values in all dental stone indicated highest after 24h(54.25 MPa < ) than the values for specimens dried in microwave method. The DTS values revealed the highest microwave method. However, in 24h, FJ(Fu-ji rock) and GM(Gemma) had lower mechanical properties than air. Conclusion : Within the limitations of this study, CS did not influence by microwave method but DTS affected according to the setting.

Relationship between among personality type, resilience, and the college life of dental technology students (치기공과 학생의 성격과 회복탄력성 및 대학생활 적응 관계)

  • Ju-Young Choi;Wol Kang
    • Journal of Technologic Dentistry
    • /
    • v.45 no.4
    • /
    • pp.102-110
    • /
    • 2023
  • Purpose: This study aims to examine the influence of personality types on recovery resilience and college life adjustment among dental technology students. Methods: The study recruited 165 students in colleges in some areas using convenience sampling. Data were processed through reliability analysis, frequency analysis, descriptive statistics, and correlation analysis. Moreover, linear regression analysis was performed to confirm the influence. Results: The results confirmed that the motivation for selecting a department exerted an effect on adaptation to college life and satisfaction with majors (p<0.05). Additionally, the finding indicated that personality type partially influenced resilience and adaptation to college life among dental technology students (p<0.05). Finally, the results of regression analysis on adaptation to college life found that resilience and satisfaction with majors were significant predictors of adaptation to college life (p<0.05). Conclusion: To improve adaptation to college life, increasing resilience and satisfaction with majors is necessary.

Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.179-186
    • /
    • 2013
  • PURPOSE. One of the most important factors in evaluating the quality of fixed dental prostheses (FDPs) is their gap. The purpose of this study was to compare the marginal and internal gap of two different metal-ceramic crowns, casting and selective laser sintering (SLS), before and after porcelain firing. Furthermore, this study evaluated whether metal-ceramic crowns made using the SLS have the same clinical acceptability as crowns made by the traditional casting. MATERIALS AND METHODS. The 10 study models were produced using stone. The 20 specimens were produced using the casting and the SLS methods; 10 samples were made in each group. After the core gap measurements, 10 metal-ceramic crowns in each group were finished using the conventional technique of firing porcelain. The gap of the metal-ceramic crowns was measured. The marginal and internal gaps were measured by two-dimensional and three-dimensional replica techniques, respectively. The Wilcoxon signed-rank test, the Wilcoxon rank-sum test and nonparametric ANCOVA were used for statistical analysis (${\alpha}$=.05). RESULTS. In both groups, the gap increased after completion of the metal-ceramic crown compared to the core. In all measured areas, the gap of the metal cores and metal-ceramic crowns produced by the SLS was greater than that of the metal cores and metal-ceramic crowns produced using the casting. Statistically significant differences were found between cast and SLS (metal cores and metal-ceramic crown). CONCLUSION. Although the gap of the FDPs produced by the SLS was greater than that of the FDPs produced by the conventional casting in all measured areas, none exceeded the clinically acceptable range.

A Study on The Dental field of Present Health Insurance for custom-made Prosthetic implant by Dental technicians (건강보험 급여화 관련 치과임플란트보철물 제작실태 연구)

  • Lee, Heekyung;Cho, Mihyang
    • Journal of Technologic Dentistry
    • /
    • v.38 no.1
    • /
    • pp.9-22
    • /
    • 2016
  • Purpose: The Purpose of this study are to describe the Dental field of present health insurance for custom-made prosthetic implant by dental technicians' work. Results: A total of 300 dental technicians working at dental laboratories in Korea were randomly selected and surveyed, 206(68.7%) of them were used for the statistical analysis. Conclusion: Average daily working time was 10 hours 66%. The average cumulative credit of the clinic for dental prosthesis fabrication rates was Less than 10 million won(21.8%), 10~80 million won(11.7%), more than one hundred million won(1.5%). Remake dental prosthesis was one more than the monthly average of 98.5%. Causes of remake dental prosthesis was dentist impression 83% but did not pay 62.5%. Dental technicians Implant production period was 7 days(48.5%), 10 days(35%) was commissioned by dentists production time is 5 days(46.1%), 7 days(36.5%). President of dental laboratories 3.86 points and dental technicians 3.06 points knew differently about starting of implant health insurance coverage(p<.001). They alike were in favor of insurance coverage for the implant. Dental technicians were lower by 2.36 points for work do you know whether your health insurance application of dental prostheses. Dental technicians are 2.16 points on whether confidence in the pores payment of insurance coverage dental prosthesis, dental laboratory president was lower by 1.85 points. They are very low with 1.97 points on whether confidence in the rate payment of health insurance coverage dental prosthesis(p<.01). The implant prosthesis abutment selected, the abutments designed, design of the implant upper prosthetic, the upper prosthetic fitting dental technicians participate of dental laboratory president showed higher score (p <.05). Conclusion: Hours of dental technicians were making this short period of remake dental prosthesis-related dental prosthesis. Dental clinic and a detailed representation of the dental prosthodontic fabrication request is required for communication between the laboratory in order to reduce the remake of a dental prosthesis, dental insurance coverage written dental prosthodontic fabrication request should be legislated. Implant classification standard medical practice 1-3 Step conduct a thorough costing a total of no. 73 of the correct classification standard medical practice in addition to eight times defined by the act of dental technicians should be defined.

A Study on Analysis of Reliability to Korean version Questionaries on Respiratory Symptoms in Korea - For the responese to dental technician Laboratory - (우리나라 호흡기계질환의 역학조사에 사용되는 설문지의 신뢰도 분석 연구 - 일부 치과기공사를 대상으로 -)

  • Ko, Jai-Chun
    • Journal of Technologic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.72-81
    • /
    • 1995
  • The study was performed to compare the raliablity of two Korean version questionaires for respiratory symptoms and ilness being used in Korea. The subjects were 103 dental laboratory technician who divided into two groups as SUN-81-AL and SUN-93. The duration of test-retest was one two month. The differences between two groups interms of average age, height, and weight were negligible. The SUN-93 showed higher agreement compared to SUN-81-AL except items cough and smoking. The Sun-93 deserved to prefer to be used in resporatory epidemiologic study.

  • PDF

Mechanical properties of porcelain fused gold alloy containing indium, tin and copper (인듐, 주석, 동 첨가에 따른 도재소부용 금합금의 기계적 특성 변화)

  • Nam, Sang-Yong;Kwak, Dong-Ju;Lee, Deok-Su
    • Journal of Technologic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.65-71
    • /
    • 2002
  • This study was performed to observe the microhardness change of the surface and the bonding strength between the porcelain and alloy specimens in order to investigate the effects of appended indium, tin and copper on interfacial properties of Au-Pd-Ag alloys. The hardness of castings was measured with a micro-Vicker's hardness tester. The interfacial shear bonding strength between alloy specimen and fused porcelain was measured with a mechanical testing system(MTS 858.20). The microhardness of Au-Pd-Ag alloy was increased by adding indium and tin, but not increased by adding copper. The shear bonding strength of Au-Pd-Ag-Sn alloy and Au-Pd-Ag-Cu alloy showed 87MPa, 57MPa. The higher concentration of adding elements showed the higher shear bonding strength.

  • PDF