• Title/Summary/Keyword: Dental inlay

Search Result 63, Processing Time 0.026 seconds

The Study on Patterns of Prosthetic Restoration, by Age and Sex - Centering the medium and small city around Chollabuk-do - (성별과 연령에 따른 치과보철물 양상에 대한 조사연구 - 전자북도의 중소도시를 중심으로-)

  • Kim, Yun-Su;Chun, Ju-Yean
    • Journal of Technologic Dentistry
    • /
    • v.12 no.1
    • /
    • pp.5-14
    • /
    • 1990
  • The purpose of this study were to investigate the patterns of prosthetic restorations according to sex and age. We had surveyed the out-patents of dental clinics it Jeon-Ju, Iri and Gun roan area. The abtained result were as follow ; 1. The patterns of prosthetic restoration in female was higher than male and 20$\sim$30 age groups was higher than others. 2. The crown was higher in prosthetic restoration. 3. The procelain appliance area was high in male and female on 20$\sim$29 age. 4. The partial denture was higher than full denture in both sex. 5. The crown appliance area was not different in both sex. 6. The 3 unit bridge was higher than other bridge in both sex. 7. The porcelain appliance area was high in male and female on upper anterior. 8. The inlay appliance area of lower posterior was higher than upper posterior. 9. The upper posterior was high in male, and the lower posterior was high in female in partial denture. 10. The full dentur was high in old age group.

  • PDF

A STUDY ON DENTAL HEALTH STATUS AND THEIR DECENNIAL COMPARISONS OF KOREAN COLLEGE GIRL STUDENTS (10년 간격으로 관찰한 여대생의 구강보건 상태 변화에 대한 연구)

  • Kang, Chung-Kyu;Lee, Chung-Suck;Lee, Chan-Young;Lee, Seung-Jong;Park, Dong-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.57-66
    • /
    • 1990
  • The author conducted a dental survey of college girl students and compared with that of college students 20 years and 10 years ago which based on the same criteria. The items of this survey included the prevalence of dental caries, DMFT and the kinds of restored materials. College girl students 2,294 were examined in May 1988, with the recommended criteria and method of W.H.O.. Among them, the data of 2,243 were analyzed and compared with the data of 1968 and 1978. The following results were obtained : 1. The average number of present teeth was $28.86{\pm}1.65$, which does not show much difference when compared to $29.00{\pm}1.94$ of 1968 and $28.97{\pm}1.64$ of 1978. 2. The prevalence of dental caries was 86.22%, which increased in comparison to 83.25% of 1968 and 84.92% of 1978. 3. DMF index was 19.98, which considerably increased in comparison to 14.56 of 1968 and 15.51 of 1978. 4. The number of DMFT was $5.75{\pm}5.04$ per student. Compared to $4.23{\pm}3.88$ of 1968 and $4.49{\pm}3.69$ of 1978, there is a considerable increase. I) The average number of decayed(D) teeth was $1.14{\pm}1.63$, which decreased from $1.16{\pm}1.57$ of 1968 and $2.09{\pm}2.16$ of 1978. II) The average number of missing(M) teeth was $0.23{\pm}0.73$, which also decreased from $0.69{\pm}1.11$ of 1968 and $0.32{\pm}0.79$ of 1978. III) The average number of filled(F) teeth was $4.39{\pm}4.91$, which increased from $2.38{\pm}3.33$ of 1968 and $2.09{\pm}3.17$ of 1978. 5. According to the analysis of filling material, filling baby including amalgam, gold inlay, resin, silicate cement and paladium inlay was 90.5%, which increased in comparison to 72.8% of 1968 and 83.6% of 1978. Among them, amalgam occupied 62.93%, which showed the most increase. On the other hand, crown and bridge was 6.5%, 3.0%, respectively, which showed continuous decrease from 12.1%, 15.1% of 1968 and 8.7%, 7.7% of 1978. Therefore, the prosthodontic treatment reduced due to the decrease of tooth extraction. In contrast, there is continuous increase of conservative treatment which maintaining natural tooth.

  • PDF

STUDIES ON THE DISTORTION OF SOME DENTAL WAXES (치과용 왁스의 변형측정에 관한 연구)

  • Kim, Cheol-We
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.17-21
    • /
    • 1978
  • The object of this study was to measure of the distortion of various dental waxes under condition simulating clinical usage. Eleven commercial product (table) including the inlay and baseplate waxes were tested, and compared in the study. Test specimens were prepared $5{\times}5{\times}65mm$. split brass mold. Placed this rod wax specimens and the brass wax distortion test mold into the water bath and tested the distortion values for waxes at $35^{\circ}C,\;40^{\cric}C,\;45^{\circ}C\;and\;50^{\circ}C$. Measured the distortion as the difference between the final (Df) and original (Do) distance between the ends of the specimen. Recorded Df, Do and Df-Do (Distortion) to the nearest 0.5mm. A minimum of five specimens were tested for each material. The following conclusions may be drawn from this study. 1) It can be seen that, a significant wax distortion was obtained with the temperature of forming the pattern, and the length of time and the temperature at which it was stored. 2) It was found that, when the storage time was increased, the wax distortion was correspondingly increased. At the sametime, the higher the storage time was employed, the distortion was obviously much greater. 3) It can be observed that the higher the temperature at which the wax was manipulated, the less was the resulting distortion upon storage.

  • PDF

Mechanical Properties and Microstructure of the Leucite-Reinforced Glass-Ceramics for Dental CAD/CAM

  • Byeon, Seon-Mi;Song, Jae-Joo
    • Journal of dental hygiene science
    • /
    • v.18 no.1
    • /
    • pp.42-49
    • /
    • 2018
  • The computer-aided design/computer-aided manufacturing (CAD/CAM) system was introduced to shorten the production time of all-ceramic restorations and the number of patient visits. Among these types of ceramic for dental CAD/CAM, they have been processed into inlay, onlay, and crown shapes using leucite-reinforced glass-ceramics to improve strength. The purpose of this study was to observe the mechanical properties and microstructure of leucite-reinforced glass-ceramics for dental CAD/CAM. Two types of leucite-reinforced glass-ceramic blocks (IPS Empress CAD, Rosetta BM) were prepared with diameter of 13 mm and thickness of 1 mm. Biaxial flexural testing was conducted using a piston-on-three-ball method at a crosshead speed of 0.5 mm/min. Weibull statistics were used for the analysis of biaxial flexural strength. Fracture toughness was obtained using an indentation fracture method. Specimens were observed by field emission scanning electron microscopy to examine the microstructure of the leucite crystalline phase after acid etching with 0.5% hydrofluoric acid aqueous solution for 1 minute. The results of strength testing showed that IPS Empress CAD had a mean value of $158.1{\pm}8.6MPa$ and Rosetta BM of $172.3{\pm}8.3MPa$. The fracture toughness results showed that IPS Empress CAD had a mean value of $1.28{\pm}0.19MPa{\cdot}m^{1/2}$ and Rosetta BM of $1.38{\pm}0.12MPa{\cdot}m^{1/2}$. The Rosetta BM sample exhibited higher strength and fracture toughness. Moreover, the crystalline phase size and ratio were increased in the Rosetta BM sample. The above results are expected to elucidate the basic mechanical properties and crystal structure characteristics of IPS Empress CAD and Rosetta BM. Additionally, they will help develop leucite-reinforced glass-ceramic materials for CAD/CAM.

The effect of hard-type crosslinked hyaluronic acid with particulate bone substitute on bone regeneration: positive or negative?

  • Yun, Junseob;Lee, Jungwon;Kim, Sungtae;Koo, Ki-Tae;Seol, Yang-Jo;Lee, Yong-Moo
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.4
    • /
    • pp.312-324
    • /
    • 2022
  • Purpose: The role of hard-type crosslinked hyaluronic acid (HA) with particulate bone substitutes in bone regeneration for combined inlay-onlay grafts has not been fully investigated. We aimed to evaluate the effect of hard-type crosslinked HA used with bone substitute in terms of new bone formation and space maintenance. Methods: A 15-mm-diameter round defect was formed in the calvaria of 30 New Zealand White rabbits. All animals were randomly assigned to 1 of 3 groups: the control group (spontaneous healing without material, n=10), the biphasic calcium phosphate (BCP) graft group (BCP, n=10), and the BCP graft with HA group (BCP/HA, n=10). The animals were evaluated 4 and 12 weeks after surgery. Half of the animals from each group were sacrificed at 4 and 12 weeks after surgery. Samples were evaluated using micro-computed tomography, histology, and histomorphometry. Results: The BCP group showed higher bone volume/tissue volume (BV/TV) values than the control and BCP/HA groups at both 4 and 12 weeks. The BCP and BCP/HA groups showed higher bone surface/tissue volume (BS/TV) values than the control group at both 4 and 12 weeks. The BCP group showed higher BS/TV values than the control and BCP/HA groups at both 4 and 12 weeks. No statistically significant difference in newly formed bone was found among the 3 groups at 4 weeks. The BCP group showed significantly higher new bone formation than the BCP/HA group at 12 weeks. Conclusions: Hard-type crosslinked HA did not show a positive effect on new bone formation and space maintenance. The negative effect of hard-type crosslinked HA may be due to the physical properties of HA that impede osteogenic potential.

Marginal and internal fit of nano-composite CAD/CAM restorations

  • Park, So-Hyun;Yoo, Yeon-Jee;Shin, Yoo-Jin;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.1
    • /
    • pp.37-43
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods: A full veneer crown and an mesio-occluso-distal (MOD) inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU) and experimental nano-composite CAD/CAM blocks (EB) under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results: Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000). In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001). Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000). Conclusions: The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

INFLUENCE OF ADHESIVE APPLICATION ON SHEAR BOND STRENGTH OF THE RESIN CEMENT TO INDIRECT RESIN COMPOSITE (치과용 접착제가 복합레진 인레이와 레진시멘트의 결합력에 미치는 영향)

  • Song, Mi-Hae;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.419-427
    • /
    • 2008
  • This study analyzed the influence of dental adhesive/primer on the bond strength between indirect resin composite and the resin cement. Seventy disc specimens of indirect resin composite (Tescera Dentin, Bisco) were fabricated. And bonding area of all specimens were sandblasted and silane treated for one minute. The resin cements were used with or without application of adhesive/primer to bonding area of indirect resin restoration, Variolink-II (Ivoclar-Vivadent) : Exite DSC, Panavia-F (Kuraray) : ED-Primer, RelyX Unicorn (3M ESPE) Single- Bond, Duolink (Risco) : One-step, Mulitlink (Ivoclar-Vivadent) : Multilinh Primer. Shear bond strength was measured by Instron universal testing machine. Adhesive application improved shear bond strength (p<0.05) But Variolink II and Panavia-F showed no statistically significant difference according to the adhesive application. With the above results, when resin inlay is luted by resin cement it seems that application of dental adhesive/primer is necessary in order to improve the bond strength.

Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay (CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구)

  • Baek, Chul-Woo;Park, Cheol-Woo;Park, Jun-Sub;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.20-26
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the bond strengths between the latest CAD/CAM ceramic inlay and various resin cements which are used primarily for esthetic restoration. Materials and methods: Cylindrical ceramic blocks(Height: 5 mm, diameter: 3 mm) were fabricated by using Cerec3 and bonded on the dentin of the ninety extracted caries-free molars using three different kinds of resin cement(Unicem$^{(R)}$, Biscem$^{(R)}$, and Variolink II$^{(R)}$) according to the manufacturer's instructions. Ninety specimens were divided into 3 groups according to three different kinds of resin cement. Half of each group were conducted thermocycling under the conditions of the $5-55^{\circ}C$, 5,000 cycle but the other half of them weren't. All specimens were kept in normal saline $37^{\circ}C$, for 24 hours before measuring the bond strength. The shear bond strength was measured by Universal testing machine with a cross head speed of 0.5 mm/min. The results were analyzed statistically by t-test and one-way ANOVA. Results: Unicem$^{(R)}$ group showed the highest shear bond strength despite a slight decline by thermocycling. The shear bond strength of Unicem$^{(R)}$ group and ValiolinkII$^{(R)}$ group were significantly influenced by thermocycling, whereas Biscem$^{(R)}$ group was not influenced (P<.05). There were no significant differences in the bond strength between the three groups without thermocycling, but there was significant differences between Unicem$^{(R)}$ group and Valiolink II$^{(R)}$ group with thermocycling(P<.05). Conclusion: It has been shown to be clinically effective when the self-adhesive resin cements Unicem$^{(R)}$ and Biscem$^{(R)}$ were used instead of the etch-and-rinse resin cement Valiolink II$^{(R)}$ during the bonding of CAD/CAM ceramic inlay restorations with teeth.

Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique (구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례)

  • Hong, Yong-Shin;Park, Eun-Jin;Kim, Sun-Jong;Kim, Myung-Rae;Heo, Seong-Joo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. For the scope of implant prosthesis, however, digital intra-oral scan hasn't been actively utilized for the fabrication of superstructures. In this case report, 6 cases of titanium-milled custom abutment based on the iTero intra-oral scan data were introduced, five of them were restored with screw-type prosthesis after cementation (SCRP) and the clinical results were satisfactory on restoring the function and esthetics.

Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form

  • Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.354-362
    • /
    • 2016
  • PURPOSE. The trueness and precision of acquired images of intraoral digital scanners could be influenced by restoration type, preparation outline form, scanning technology and the application of power. The aim of this study is to perform the comparative evaluation of the 3-dimensional reproducibility of intraoral scanners (IOSs). MATERIALS AND METHODS. The phantom containing five prepared teeth was scanned by the reference scanner (Dental Wings) and 5 test IOSs (E4D dentist, Fastscan, iTero, Trios and Zfx Intrascan). The acquired images of the scanner groups were compared with the image from the reference scanner (trueness) and within each scanner groups (precision). Statistical analysis was performed using independent two-samples t-test and analysis of variance (${\alpha}=.05$). RESULTS. The average deviations of trueness and precision of Fastscan, iTero and Trios were significantly lower than the other scanners. According to the restoration type, significantly higher trueness was observed in crown and inlay than in bridge. However, no significant difference was observed among four sites of preparation outline form. If compared by the characteristics of IOS, high trueness was observed in the group adopting the active triangulation and using powder. However, there was no significant difference between the still image acquisition and video acquisition groups. CONCLUSION. Except for two intraoral scanners, Fastscan, iTero and Trios displayed comparable levels of trueness and precision values in tested phantom model. Difference in trueness was observed depending on the restoration type, the preparation outline form and characteristics of IOS, which should be taken into consideration when the intraoral scanning data are utilized.